• Title/Summary/Keyword: 필요환기량

Search Result 106, Processing Time 0.029 seconds

Effect of Side Openings and Greenhouse Width on the Natural Ventilation Performance (측창 및 온실 폭이 자연환기 성능에 미치는 영향)

  • Hyun Woo Lee;Young Hoe Woo;Jong Won Lee
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.25 no.1
    • /
    • pp.14-19
    • /
    • 2023
  • In summer, the natural ventilation performance for varying greenhouse width is very important in the glasshouses for year round cultivation. The effect of the side openings and greenhouse width on natural ventilation performance was analyzed by simulation. The necessary ventilation rate with different solar radiation transmittance increased significantly when the outside temperature grows higher. The necessary ventilation rate of 40% transmittance was about half of that of 90% transmittance. In consequence, shading effect on temperature control in greenhouse is significant in summer. When the total area of the openings for ventilation is constant, the maximum ventilation rate happens when the area of roof openings is equal to the area of side openings. This maximum ventilation rate is about 3 times of that of the greenhouse with roof openings and without side openings. Therefore, the side openings are advantageous to improve the natural ventilation in greenhouses. As the greenhouse width increases, the influence of side openings on the ventilation rate is becoming smaller. If the natural ventilation rate of the greenhouse with roof and side openings is to become double of that of the roof openings only, the width should be narrower than 38.4m for the Venlo type and 64m for Wide span type.

환기시스템에 의한 Sick House 대책

  • Kimura, Hiroshi
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.9
    • /
    • pp.46-51
    • /
    • 2003
  • "환기"는 생활용품 등으로부터의 오염물질 및 불특정 물질의 농도 저감이 가능하기 때문에 Sick House 대책으로서의 중요한 대책기술이다. 본 고에서는 집합주택을 대상으로 한 중앙공조 환기방식 및 배기 중앙 환기방식의 사례를 보여주고, 시스템의 구성기술과 오염물질의 농도 저감효과에 대해서 기술한다. 또한, 대표적인 오염물질인 포름알데히드의 건자재로 부터의 발산량은 온습도, 환기량 및 건자재의 표면적 비율 등의 영향인자에 따라 변화하므로, 필요 환기량은 이들의 영향요인을 고려하여야 한다는 것을 기술한다.

  • PDF

Application of Heat Balance Model Design of Ventilating and Cooling Greenhouse (온실의 환기 및 냉방 설계를 위한 열평형 모델의 작용)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.201-206
    • /
    • 2000
  • A certain system to overcome high temperature should be introduced for the stable year-round cultivation in greenhouses. There are efficient methods to overcome high temperature such as ventilation system with shading screen, fan and pad system with screen, and fog system with screen. This study was carried out to find a means to determine the capacity of such system. Heat balance equations for each system were established and verified by experimental results. The calculated ventilation rates from heat balance equations showed a good agreement with the measured ones. The evapotranspiration coefficient was the most important parameter affecting the ventilation requirement among input parameter affecting the ventilation requirement among input parameters except weather data. When the evaportanspiration coefficient increased 1%, the ventilation requirement decreased 1.3%. Therefore the data of evapotranspiration coefficient should be accumulated by various experiments, and then design standards and selection guidelines should be provided. The simulation results for same design conditions shown that air exchanges requirement and evaporating water of fan and pad system were 5.1∼7.7% and 6.8∼9.3% larger than those of fog system, respectively.

  • PDF

외기전담시스템(Dedicated Outdoor Air System)에 관하여

  • 한화택
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.7
    • /
    • pp.41-44
    • /
    • 2003
  • 실내의 냉난방부하와 필요환기량을 동시에 처리하던 기존의 전공기 공조시스템과 달리 냉난방과 환기를 분리하여 개별적으로 담당하는 외기전담시스템에 관하여 소개한다.

  • PDF

The Study on Optimum Ventilation System during Long Tunnel Construction (굴착중인 장대터널내 최적의 환기시스템에 대한 연구)

  • Oh, Byung-Hwa;Lim, Han-Uk
    • Explosives and Blasting
    • /
    • v.24 no.2
    • /
    • pp.9-22
    • /
    • 2006
  • In general, tunnel construction except for special cases such as very short tunnels must require an artificial ventilation system. Especially, it is efficient for long tunnels to use the combination of a proper ventilation system according to the progress of the excavation. Neung-Dong Tunnel of which length is 4,580m has been originally designed as using ventilation system of blower and exhaust mixture types. Since it has been expected to result in some problems, its design Is analyzed to find the way to improve ventilation system by estimating the amount of required fresh air, considering various ventilation mixture types, ventilation's fluidity analysis and contaminant's distribution by numerical analysis. Economical efficiency for each type is also reviewed to determine the best ventilation system.

Threshold Limit Value of Welding Fume (용접 Fume의 허용농도와 필요 환기량)

  • 한회춘;이수안;정인수
    • Journal of Welding and Joining
    • /
    • v.2 no.2
    • /
    • pp.7-12
    • /
    • 1984
  • 중화학공업과 조선공업이 비약적으로 발달됨에 따라 우리나라의 용접기술은 진일보를 거듭하였다. 그러나 각종 용접에 따른 산업재해(감전, 용접 fume 및 가스에 의한 진폐, 중독, 화상 등)도 날로 증가하는 추세로 이러한 용접재해 중 용접흄(fume)으로 인한 안전위생 및 환경오염적인 측면에서 큰 문제점을 야기하고 있으나 아직 국내에서는 여기에 대한 관심 및 연구가 미비한 실정이다. 그러므로 본 고에서는 용접 fume에 대한 개괄적인 면을 소개하고, 그 중 현실로 직면하는 "현장 용접장의 흄(fume) 및 흄의 특정성분에 대한 관리허용농도의 현황과 흄 발생량에 따른 필요 환기량"을 기술하고자 한다. 기술하고자 한다.

  • PDF

Natural Ventilation Performance in Greenhouses (온실의 자연환기 성능)

  • 이석건
    • Journal of Bio-Environment Control
    • /
    • v.11 no.1
    • /
    • pp.45-49
    • /
    • 2002
  • 온실에서 환기는 온실내외의 공기를 교환하여 온실내부의 환경을 조절하는 수단으로 활용되고 있으나 조절 목표는 한계가 있기 때문에 보조수단의 역할을 한다. 주년재배용 대규모 온실 설계시 해결해야 할 문제중의 하나가 여름철의 고온장해이며 이는 온실의 자연환기 성능과 밀접한 관계를 가지고 있다. 본 강좌에서는 온실의 자연환기에 관한 기본적인 내용을 요약하여 정리하고, 온실구조가 자연환기 성능에 미치는 영향을 파악하기 위하여 수치해석으로 온실의 필요환기량, 측창과 천창의 면적비와 온실 폭이 자연환기 성능에 미치는 영향을 분석하였다. 온실의 자연환기 성능을 향상시키기 위해서는 주어진 조건하에서 가능한 한 측창과 천창의 면적을 동일하게 설계해야 하고 주년재배용 대규모 온실에서는 폭이 대략 50m이상이 되면 자연환기성능을 기대하기 어렵기 때문에 유의해야 할 것으로 판단된다.

A study on the effects of exhaust emission standards on the required ventilation rate in vehicle tunnels (차량 배출가스 규제기준이 소요환기량에 미치는 연구)

  • Kim, Hyo-Gyu;Ryu, Ji-Oh;Song, Seog-Hun;Jung, Chang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.409-420
    • /
    • 2017
  • The amount of ventilation required in making the tunnel ventilation plan is an important factor for determining the capacity of the ventilation system. The amount of pollutant emission for each type of vehicle (basic emission amount for the design of ventilation volume) for estimating the required ventilation amount is based on the 'Standard for Allowing the Emission for the car manufacturing', proposed by Ministry of Environment. However, in 2013, the Ministry of Environment announced the 'Regulations on the calculation method of total emissions from vehicles' as a regulation for calculating the pollutants emitted from vehicles. In this regulation, there are the 'Emission factors for each type of vehicle'. Therefore, it is necessary to review the application of the Regulation to the estimation of the required ventilation volume for the road tunnel. In this study, the influence of the strengthened emission regulation in 2015 caused by the case of manipulation of emission volume for the diesel vehicle on the calculation of the required ventilation volume in the road tunnel has been checked. In addition, in this study, the required ventilation volume calculated according to the Standard for Allowing the Emission for the car manufacturing revised by Ministry of Environment and "Emission factors for each type of vehicle" and that calculated according to the EURO emission standard were compared for analysis. This study has implications that it provides the basic design data for calculating the reasonable ventilation capacity of the ventilation system based on the ground for calculating the required ventilation volume.

Evaluation of Changes in Radon Levels in Educational Research Facilities by Number of Ventilation and Time (환기횟수 및 환기시간에 따른 교육연구시설 라돈 수치변화 평가)

  • Shin, Yoon-Seok;An, Jae-Seung;Kim, Seong-Bin;Park, Min-Young
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.335-336
    • /
    • 2023
  • 최근 환경에 대한 관심이 지속적으로 증가함에 따라 실내 공기질에 대한 관심 역시 증폭되었다. 이에 따라 실내 공기질을 결정 짓고 흡연에 이어 폐암 사망률이 높은 라돈에 대한 관심 역시 증가하였다. 따라서 본 연구에서는 실내 라돈가스의 농도를 낮추기 위한 방법을 찾기 위해 RADON EYE RD200을 이용하여 교육연구시설에서의 세 강의동을 대상으로 라돈 방출량을 측정하고, 환기를 통해 라돈의 감소량을 측정한다. 세 강의동 모두 현재 기준치인 148 Bq/m3을 초과하는 수치를 기록하였고, 강의실을 10분간 환기한 결과 1회 환기 시 평균 77 Bq/m3만큼 감소하였고, 2회 환기 시 평균 56 Bq/m3만큼 감소하였다. 본 연구를 통해 라돈의 실태 및 위험성을 인지하고 라돈에 관련된 시설물 지침 및 환기를 강조하는 방안에 대한 마련이 필요하다고 판단된다.

  • PDF