• Title/Summary/Keyword: 필름 선량측정

Search Result 202, Processing Time 0.038 seconds

Neutron Dosimetry with Solid State Track Detector (고체비적검출기(固體飛跡檢出器)를 이용(利用)한 중성자선량(中性子線量) 측정(測定))

  • Yook, Chong-Chul;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1977
  • A base of photographic posi-film which is commecially available has been found to be a possible alpha-particle track detector. Its neutron dosimetric characteristics, i. e., alpha-particle track registrating efficiency and optimum condition of track formation by chemical etching, have been determined experimentally. The range of neutron fluence and dose capable of being measured by a neutron dosimeter consisting of alpha-particle radiator foils $(^{10}B\;and\;^{27}Al)$ and posi-flim solid state track detector, has been estimated on the basis of experimental results and theoryetical background. This detector seems to be useful for neutron dosimetry because of many favorable properties, i. e., simplicity, cheapness and a wide range of sensitivitiy.

  • PDF

Influence of Total Laryngectomy on Spinal Cord Dose in Advanced Laryngeal Cancers (진행된 후두암 환자에서 후두전절제술에 의한 척수선량 변화)

  • Kim, Jae-Cheol;Kim, Sung-Hwan;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.167-173
    • /
    • 1996
  • Purpose : This analysis was to evaluate the radiation dose around a tracheostoma and spinal cord in the case of advanced laryngeal cancers in which a total laryngectomy was done before radiotherapy. Materials and Methods : The radiation dose around a tracheostoma and spinal cord was measured by thermoluminescence and film dosimetry in the phantom, Radiotherapy treatment planning was done in 12 cases of advanced laryngeal cancer and compared with the measured dose in the phantom. Results : Mean spinal cord doses in the phantom by thermoluminescence dosimetry were $86.4\%$ (with a tracheostoma), $80.1\%$ (without a tracheostoma), and the difference was $6.3\%$. Mean spinal cord doses in the phantom by film dosimetry were $84.7\%$ (with a tracheostoma), $79.0\%$ (without a tracheostoma). and the difference were $5.7\%$. Calculated spinal cord doses in the phantom were $84.0\%$ (with a tracheostoma), $78.0\%$ (without a tracheostoma), and the difference was $6.0\%$. Mean calculated spinal cord doses in 12 patients were $83.1\%$ (with a tracheostoma), $76.9\%$ (without a tracheostoma). and the difference was $6.2\%$. Measured dose of lateral and posterior wall of the tracheostoma by film was low (depth of maximum dose = 12 mm). Conclusion : In the treatment planning of the advanced laryngeal cancers, the radiation dose of the tracheostoma and spinal cord should be evaluated and be followed by an appropriate management such as a bouls or a brachytherapy boost if the dose around the tracheostoma is low.

  • PDF

Anisotropy in a Few mm Regions from an Ir192 High Dose Rate Source Measured with a GafChromic Film in Acrylic Phantom (아크릴 팬톰에서 GafChromic 필름을 이용한 고선량률 근접 치료용 Ir-192 선원의 근접 거리에서 비등방성 측정)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Park, Jin-Ho;Cho, Byung-Chul;Shin, Dong-Oh;Soo il Kwon;Chun, Ha-Chung;John J K Loh;Kim, Woo-Chul
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Radiochromic film has several advantages; high spatial resolution, relatively low spectral sensitivity, near tissue equivalence and requires no special development procedure. The object of this study was to measure the anisotropy of an Ir-192 source (microSelectron manufactured by Nucletron) in a few mm regions from the source, using the GafChromic film. The GafChromic film was calibrated in the range of 0∼105 Gy, using a 4 MV photon beam, and the anisotropy function measured in an acrylic phantom using the GafChroimic film. The data obtained gave agreement to within 4.4% of the Monte Calro calculation, by J. F. Williamson, at a radial distance of 2.5 mm with polar angles of 50 to 130$^{\circ}$, while a maximum deviation of 17.6% was observed at angles near 140$^{\circ}$and agreement within 3.7% at a radial distance of 5 mm at polar angles between 35 to 150$^{\circ}$ and a maximum deviation of 7.6% was observed at angles near 30$^{\circ}$. A GafChromic film can be used as a more efficient detector for measuring the anisotropy of an HDR $^{192}$ Ir source at close distances than any other detector.

  • PDF

Evaluation of the Radiochromic Film Dosimetry for a Small Curved Interface (휘어진 경계에서의 좁은 영역에 대한 Radiochromic 필름 도시메트리 평가)

  • Kang, Sei-Kwon;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.234-238
    • /
    • 2012
  • A tumor on the eyelid is often treated using a high-energy electron beam, with a metallic eye shield inserted between the eyelid and the eyeball to preserve the patient's sight. Pretreatment quality assurance of the inner eyelid dose on the metallic shield requires a very small dosimetry tool. For enhanced accuracy, a flexible device fitting the curved interface between the eyelid and the shield is also required. The radiochromic film is the best candidate for this device. To measure the doses along the curved interface and small area, a 3-mm-wide strip of EBT2 film was inserted between the phantom eyelid and the shield. After irradiation with 6 MeV electron beams, the film was evaluated for the dose profile. An acrylic eye shield of the same size as the real eye shield was machined, and CT images free from metal artifacts were obtained. Monte Carlo simulation was performed on the CT images, taking into account eye shield material, such as tungsten, aluminum, and steel. The film-based interface dose distribution agreed with the MC calculation within 2.1%. In the small (millimeter scale) and curved region, radiochromic film dosimetry promises a satisfactory result with easy handling.

Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel (중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정)

  • Oh Young-Taek;Kang Haejin;Kim Miwha;Chun Mison;Kang Seung-Hee;Suh Chang Ok;Chu Seong Sil;Seong Jinsil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.264-273
    • /
    • 2002
  • Purpose : Three-dimensional radiation dosimetry using magnetic resonance imaging of polymer gel was recently introduced. This dosimetry system is based on radiation induced chain polymerization of acrylic monomers in a muscle equivalent gel and provide accurate 3 dimensional dose distribution. We planned this study to evaluate the clinical value of this 3-dimensional dosimetry. Materials and Methods: The polymer gel poured into a cylindrical glass flask and a spherical glass flask. The cylindrical test tubes were for dose response evaluation and the spherical flasks, which is comparable to the human head, were for isodose curves. T2 maps from MR images were calculated using software, IDL. Dose distributions have been displayed for dosimetry. The same spherical flask of gel and the same irradiation technique was used for film and TLD dosimetry and compared with each other. Results : The R2 of the gel respond linearly with radiation doses in the range of 2 to 15 Gy. The repeated dosimetry of spherical gel showed the same isodose curves. These isodose curves were identical to dose distributions from treatment planning system especially high dose range. In addition, the gel dosimetry system showed comparable or superior results with the film and TLD dosimetry. Conclusion : The 3-dimensional dosimetry for conformal radiation therapy using MRI of polymer gal showed stable and accurate results. Although more studies are needed for convenient clinical application, it appears to be a useful tool for conformal radiation therapy.

구동 팬톰 시스템을 통한 내부 장기 움직임의 선량 평가

  • Kim, Jae-Gyun;Kim, Yun-Jong;Lee, Dong-Han;Lee, Dong-Hun;Kim, Mi-Suk;Jo, Cheol-Gu;Ryu, Seong-Ryeol;Yang, Gwang-Mo;Yu, Hyeong-Jun;Ji, Yeong-Hun
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.64-67
    • /
    • 2005
  • 본 연구의 목적은 호흡 운동에 영향을 받는 내부 장기의 움직임을 정량적으로 분석하고, 그 결과를 토대로 움직이는 내부 장기의 선량 분포를 측정하고 평가하는 것이다. 그리고 이전에 보고된 논문에서 개발된 움직임 감소 장치의 사용 유무에 따른 내부 장기의 선량 분포 또한 분석하는 것이다. 이를 위하여 1차원적으로 움직이는 구동 팬톰 시스템을 개발하였고, 6MV X-ray에서 Kodak X-omat V 필름을 사용하여 움직이는 내부 장기의 선량분포를 실험적으로 측정하였다. 이 결과로부터 호흡 운동으로 인한 움직이는 내부 장기 및 종양에 조사되는 선량의 부정확도를 평가할 수 있었고, 움직임 감소 장치를 사용했을 때 선량의 부정확도가 감소함을 확인할 수 있었다.

  • PDF

Evaluation of superficial dose for Postmastectomy using several treatment techniques (유방전절제술을 시행한 환자에서 치료기법에 따른 피부선량 평가)

  • Song, Yong Min;Choi, Ji Min;Kim, Jin Man;Kwon, Dong Yeol;Kim, Jong Sik;Cho, Hyun Sang;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.225-232
    • /
    • 2014
  • Purpose : The purpose of this study was to evaluate the surface and superficial dose for patients requiring postmastectomy radiation therapy(PMRT) with different treatment techniques. Materials and Methods : Computed tomography images were acquired for the phantom(I'mRT, IBA) consisting of tissue equivalent material. Hypothetical chestwall and lung were outlined and modified. Five treatment techniques(Wedged Tangential; WT, 4-field IMRT, 7-field IMRT, TOMO DIRECT, TOMO HELICAL) were evaluated using only 6MV photon beam. GafChromic EBT3 film was used for dose measurements at the surface and superficial dose. Surface dose profiles around the phantom were obtained for each treatment technique. For superficial dose measurements, film were used inside the phantom and analyzed superficial region for depth from 1-6mm. Results : TOMO DIRECT showed the highest surface dose by 47~70% of prescribed dose, while 7-field IMRT showed the lowest by 35~46% of prescribed dose. For the WT, 4-field IMRT and 7-field IMRT, superficial dose were measured over 60%, 70%, and 80% for 1mm, 2mm, and 5mm depth, respectively. In case of TOMO DIRECT and TOMO HELICAL, over 75%, 80%, and 90% of prescribed dose was measured, respectively. Surface and superficial dose range were uniform in overall chestwall for the 7-field IMRT and TOMO HELICAL. In contrast, Because of the dose enhancement effect with oblique incidence, The dose was gradually increased toward the obliquely tangential angle for the WT and TOMO DIRECT. Conclusion : For PMRT, TOMO DIRECT and TOMO HELICAL deliver the higher surface and superficial doses than treatment techniques based linear accelerator. It showed adequate dose(over 75% of prescribed dose) at 1mm depth in skin region.

Simplistic QA for an Enhanced Dynamic Wedge using the Reversed Wedge Pair Method (역방향 조사방식을 통한 동적쐐기의 품질관리)

  • Lee Jeong Woo;Hong Semie;Suh Tae Suk
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.161-166
    • /
    • 2004
  • A simplistic quality assurance (QA) method was designed for a Linac built-in enhanced dynamic wedge (EDW), which can be utilized to make wedged beam distributions. For the purpose of implementing the EDW symmetry QA, a film dosimetry system, low speedy dosimetry film, film densitometer and 3D RTP system were used, and the films irradiated by means of a 60$^{\circ}$ Reversed wedge pair (REWP) method. The profiles were then analyzed in terms of their symmetries, including partial treatment, which is the case of stopping it abruptly during EDW irradiation, and the measured and calculated values compared using the Cad Plan Golden Segmented Treatment Table (Golden STT). The result of this experiment was in good agreement, within 1 %, of the 'reversed wedge pair counterbalance effect'. For the QA of the effective wedge factor (EWF), the authors measured EWFs in relation to the 10$^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$ EDW, which were compared with the calculated values using the correction factor derived from the Golden STT and the log files produced automatically during the process of EDW irradiation. By means of this method it was capable of check up the safety of effective wedge factor without any other dosimetry system. The EDW QA was able to be completed within 1 hour from irradiation to analysis as a consequence of the simplified QA procedure, with maximized effectiveness. Unlike the metal wedge system, the EDW system was heavily dependent on the dose rates and jaw movements; therefore, its features could potentially cause inaccuracy. The frequent simplistic QA for the EDW is essential, and could secure against the flaw of dynamic treatment that uses the EDW.

  • PDF