• Title/Summary/Keyword: 필라멘트

Search Result 435, Processing Time 0.026 seconds

Design of Soft X-ray Tube and Simulation of Electron Beam by Using an Electromagnetic Finite Element Method for Elimination of Static Electric Field (전자기 유한요소법 전자빔 시뮬레이션을 이용한 정전기장 제거용 연한 X-선관 설계 특성 연구)

  • Park, Tae-Young;Lee, Sang-Suk;Park, Rae-Jun
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.2
    • /
    • pp.66-69
    • /
    • 2014
  • The spreading tube of X-ray cathode tube displayed with an electromagnetic finite element method was designed. To analyze a feature design and the concrete coordinate performance of soft X-ray tube modeling, the orbit of electron beam was simulated by OPERA-3D SW program. The fixed conditions were the applied voltage, the temperature, the work function of thermal electron between cathode and anode of tungsten. Through the analysis of distribution of electron beam and the variation of dividing region, the design of soft X-ray spreading tube equipped with two cross filaments was optimized.

Manufacturing Processes of Cylindrical Composite Lattice Structures using Filament Winding Method (필라멘트 와인딩 공법을 이용한 원통형 복합재 격자구조체 제작 공정)

  • Im, Jaemoon;Shin, Kwangbok;Lee, Sangwoo;Son, Johwa
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.835-837
    • /
    • 2017
  • In this paper, manufacturing processes of cylindrical composite lattice structures using filament winding method was described. Cylindrical composite lattice structures were manufactured in accordance with four major steps. Silicon mold of lattice shape was installed on mandrel and then continuous fiber was wound on silicon mold. After winding process, in order to ensure the same thickness for all regions, compression process was done for its intersection parts. Finally, the composite lattice structure was demoulded after curing in oven. It was found that the manufactured cylindrical composites lattice structure had 2.4% of dimensional error compared to the design requirements.

  • PDF

Analysis of filament Wounded Composite Rocket Motor (필라멘트 와인딩 복합재료 연소관의 구조적 안정성 연구)

  • Lee Yoon-kyu;Kwon Tae-hoon;Lee Won-bok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.278-281
    • /
    • 2004
  • The purpose of this paper is to show a reliable analytical method to predict the deflections of F/W Composite Motor Case. Structural analysis and testing of a Carbon/Epoxy Composites Motor Case for Pressure Loadings were performed. This paper presents the development of 3-D layered axi-symmetric solid element for finite element analysis. Finite element analyses were preformed considering fiber angle variation in longitudinal and thickness direction by ANSYS. The analytical results agree well with experimental results.

  • PDF

Effects of Heat Temperature in Sizing and Pretreatment Processes on the Appearance Colour of the Polyester Fabrics (사이징 및 전처리 공정에서의 열처리 온도 변화에 따른 폴리에스테르 직물의 염색성 변화)

  • Cho, D.H.;Kim, S.J.;Chang, D.H.
    • Textile Coloration and Finishing
    • /
    • v.11 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • 이 연구에서는 사이징 공정을 포함해서 수세, 전처리 그리고 최종 열처리 둥의 염색.가공 공정에서의 습열 및 건열 처리 온도가 폴리에스테르 직물의 열응력과 염색성에 미치는 영향을 조사하였다. 사용된 폴리에스테르 필라멘트사는 경사가 50d/24f 스파크사이며 위사는 75d/72f semi-dull사이다. 평직물은 션틀직기, 주자직물은 water jet 직기로 제직하였으며, sizing dryer 온도는 $90^\circ{C}$, $125^\circ{C}$, $150^\circ{C}$, 수세공정의 습열처리 온도는 $90^\circ{C}$, $110^\circ{C}$, $120^\circ{C}$, 전처리 공정의 건열처리 온도는 $180^\circ{C}$, $200^\circ{C}$, $220^\circ{C}$, 마지막 세팅 공정의 건열처리 온도는 $170^\circ{C}$, $180^\circ{C}$, $200^\circ{C}$로 변화시켰다. 이들 습열과 건열처리 온도 변화에 따른 직물내의 필라멘트사의 열 수축률과 직물의 겉보기 염색성의 변화를 조사 분석하였다.

  • PDF

A Study on Design of Type IV Hydrogen Pressure Vessels with Filament Winding Method (필라멘트 와인딩 공법을 적용한 타입 IV 수소 압력용기 설계 연구)

  • Sungjin Ahn;Hyunbum Park
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.127-132
    • /
    • 2023
  • In this study, designing of a Type 4 pressure vessel using the filament winding method was conducted. In order to prevent leakage in consideration of the design of the hydrogen storage tank, a liner was designed by applying high-density polyethylene (HDPE), and the composite structure was designed by stacking carbon/epoxy in the hoop and helical directions. As a theoretical approach, the angle of the helical fiber and fiber thickness of each hoop and helix were designed. The safety of the design was verified using the commercial software ANSYS.

The Effect of Contamination of Ion Source on Ionic Current of Quadrupole Mass Spectrometer (사중극 질량 분석기의 이온소스 오염이 이온전류에 미치는 영향)

  • Lee, K.C.;Park, C.J.;Kim, J.T.;Oh, E.S.;Hong, K.S.;Hong, S.S.;Lim, I.T.;Yun, J.Y.;Kang, S.W.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.197-202
    • /
    • 2009
  • The long term stability of ion current of QMS has been one of key parameters for monitoring gas process in vacuum. The time dependence of ionic current was monitored while the pressure of nitrogen gas was kept at a fixed pressure by introducing the gas into vacuum chamber. The chamber was evacuated to ${\sim}3{\times}10^{-9}\;Torr$ to reduce background signals before the measurement. Two ion sources were tested; one had brownish or black color due to gas contamination and the other one was new, i.e. cleaner. At a nitrogen pressure of $1{\times}10^{-5}\;Torr$, the ionic currents measured by the contaminated ion source decreased faster with time. The decrease rate was respectively ${\sim}46%$ for cleaner one and ${\sim}84%$ for contaminated one after ${\sim}5.5%$ hours. In order to test the effect of filament material on the ion current decrease, we fabricated a tungsten(W) filament which consisted of two parts; one half was made of W and the other was coated with yttria. The similar decrease of ionic currents were shown for the two types of filaments, indicating that slight change of temperature of filament due to material difference i.e. baking effect could not improve the origin of ionic current decrease. Overall the decreasing rate of ionic current is more closely associated with contaminated ion source of QMS rather than its filament materials.

The Effects of Cooking Temperature and Time on Gel Propertof Surimi-like Material from Porcine semimembranosus Musclye (돼지 반막양근을 이용한 수리미 유사물질의 겔 특성에 미치는 가열시간과 온도의 영향)

  • Han, Chul-Yong
    • Culinary science and hospitality research
    • /
    • v.15 no.4
    • /
    • pp.99-114
    • /
    • 2009
  • This study examined the optimal cooking condition for surimi-like material (SLM) derived from porcine semimembranosus (SM) muscle and the effects of the various cooking temperatures and the cooking time on the gel properties. The most noticeable change that occurred during the preparation of the SLM from the SM was the reduction in the fat content (about 1%) during the washing procedures. The hardness and gel strength value were increased significantly as the cooking temperature was increased by $75^{\circ}C$ for 20 min (p<0.05). The SLMG cooked above $75^{\circ}C$ had a significantly higher WHC than the SLMG cooked below $75^{\circ}C$ (p<0.05). The gelling property of SLMG was effected for different conditions of cooking time and temperatures by the result of SDS-PAGE. After 20 min cooking, some enzyme bands including phosphorylase disappeared. The loss of these bands (about 46 kDa and 60 kDa) was observed after 20 min of cooking time. The photographs of microscopy showed that the filaments of myofibrils did not disappear after a cooking time of 15 min, and that the gaps between the fibers or filament were close. A significant change in the fibers and filaments occurred from 30 min to 35 min of cooking time, and the gradual coagulation of the structure of the SLM was observed with cooking time increased. These results suggest that a desirable surimi gel could be obtained from pork by cooking at $75^{\circ}C$ for 25 min.

  • PDF

Effect of Temperature on Interlaminar Fracture Toughness of Filament-Wound Carbon/Epoxy Composites (필라멘트 와인딩된 카본/에폭시 복합재의 층간파괴인성에 미치는 온도 영향)

  • Im, JaeMoon;Shin, KwangBok;Hwang, Taekyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.491-497
    • /
    • 2015
  • This paper reports an experimental study for evaluating the effect of temperature on the mode I, mode II and mixed-mode interlaminar fracture toughness of adhesive joints with a curved cross-section of filament-wound dome-separated composite pressure vessel. Mode I and mixed-mode interlaminar fracture toughness were evaluated using DCB specimens, while mode II interlaminar fracture toughness was determined using ENF specimens. $[{\pm}10^{\circ}]_6$, $[{\pm}27^{\circ}]_6$ and ($[{\pm}10^{\circ}]_3/FM73/[{\pm}27^{\circ}]_3$) winding specimens with the curved cross-section were considered. In-situ temperature environments were simulated with a range of $-30^{\circ}C-60^{\circ}C$ using an environmental chamber and furnace. Experimental results on the effect of temperature indicate that interlaminar fracture toughness tends to be high at low temperature and is degraded with increase in temperature. For specimen types, it was found that interlaminar fracture toughness of $[{\pm}10^{\circ}]_3/FM73/[{\pm}27^{\circ}]_3$ winding specimens considered as adhesive joints of dome and helical part was higher than other specimens.

Mechanical Properties and Electrical Conductivities of In-Situ Cu-9Fe-1.2X(X=Ag, Cr, Co) Microcomposite Wires (Cu-9Fe-1.2X (X=Ag, Cr, Co)계 미세복합재료전선의 기계적 특성 및 전기전도도)

  • Song, Jae-Suk;Im, Mun-Su;An, Jang-Ho;Hong, Sun-Ik
    • Korean Journal of Materials Research
    • /
    • v.10 no.1
    • /
    • pp.41-48
    • /
    • 2000
  • In this study, microstructure and mechanical properties and electrical conductivities of in situ Cu-Fe-Xi(Xi=Ag, Cr or Co) alloy wires obtained by cold drawing combined with intermediate heat treatments have investigated. During cold working the primary and secondary dendrite arms are aligned along the drawing direction and elongated into filaments after deformation processing. The addition of Ag was found to be more effective in reducing the microstructural scale at the given draw ratio than that of Co or Cr throughout the drawing processing. The ultimate tensile strength and the conductivity of the Cu-Fe based composites containing Ag were higher than those of Cu-Fe composites containing Co or Cr. The good mechanical and electrical properties of Cu-Fe-Ag wires may be associated with the more uniform distribution of the finer filaments in the wires containing silver. The strength of Cu-Fe-Xi composites is dependent on the spacing of the Fe filaments in accord with a Hall-Petch relationship. The fracture surfaces of all the specimens showed ductile-type fracture and iron filaments occasionally observed on the fracture surfaces.

  • PDF

The isobaric effect correction and measurement of the Ru isotopes by thermal ionization mass spectrometry (열 이온화 질량분석기를 이용한 Ru 동위원소 측정 및 동중원소 영향 보정)

  • Jeon, Young-Shin;Kim, Jung-Suk;Han, Sun-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.498-504
    • /
    • 2010
  • It is very difficult to get stable ion peak intensity of ruthenium by thermal ionization mass spectrometry because of its high ionization potential and high volatility of its oxides which causes to lose much of ruthenium ions, so the intensity of the signal decrease quickly. Accordingly, a study was performed in oder to increase the ionization efficiency and to prevent sample losses due to volatilization and to check with isobaric effect by impurities in filament for the measurement of ruthenium isotopes. Both single filament and double filament were tested. The former was proved to be more efficient for the stable and strong intensity of signal and revealed less isobaric effect from the molybdenum (Mo) as a filament impurity. Also, when the temperature of filament increased too high, the isobaric effect from Mo greatly appeared. That is, Mo impurity from filament gave a serious effect for measuring the ruthenium isotopes. It was proved to be of importance that filament current should be slowly increased with time interval. Finally, ruthenium isotopes were accurately measured by correction with measuring $^{94}Mo/^{99}Ru$.