• Title/Summary/Keyword: 필드시험

Search Result 68, Processing Time 0.026 seconds

A Gap Coupled NRD-Guide Filter Designed with an Equivalent Circuir Model of Evanescent Waveguide (차단주파수 영역 도파관 등가회로 모델을 이용한 Gap-Coupled NRD Guide 대역통과 여파기의 설계)

  • 김소영;이정해
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.990-995
    • /
    • 2000
  • As the interest in the millimeter wave frequency (30 ~300 GHz) increases, Nonradiative Dielectric (NRD) guide is being more attractive due to its low loss characteristics. Most of millimeter wave components, which can be realized with waveguide, can also be realized with NRD guide since NRD guide has similar dispersion characteristics and field patterns to waveguide. Previously, Variational Method was applied to the gap discontinuity problem to design a gap-coupled NRD bandpass filter. In this paper, the design procedure was simplified by replacing the air gap region with an equivalent circuit model of an evanescent waveguide using the fact that the NRD guide has a similar structure with a dielectric-filled metal waveguide. Prior to applying this design method to the bandpass filter of millimeter wave frequency range, a bandpass filter of which center frequency is 10 GHz(3-Pole, 0.1 dB ripple, 2% fractional bandwidth) was designed and fabricated. The measured result agrees with one simulated with HFSS within an error range of a fabrication.

  • PDF

Measurement of Electromagnetic Wave for the Selection of Certification Test Space at GSM Band (GSM 대역용 휴대전화 인증 시험 공간 확보를 위한 전파 환경 측정)

  • Park, Chul-Keun;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.9
    • /
    • pp.1030-1038
    • /
    • 2007
  • This paper presents the measurement results of strength of electromagnetic wave for GSM-900/GSM-1800 band which is used in Europe. The Giryong village and Sosan field are selected as candidate regions according to the measurement results in Gijang-gun, Busan. The vertical polarizations is about 12 dBm higher than horizontal polarization at two candidate places, and it is measured 25 dBm lower than urban. The maximum value of measured strength of vertical polarizations in the cellular/GSM-900 bands are -65 dBm at Giryong village and -69 dBm at Sosan field, respectively. The maximum value of measured results of PCS/GSM-1800 bands are -90.5 dBm at Giryong village and -85 dBm at Sosan field, respectively, We confirm that the receiving strength of electromagnetic wave are very weak below -65 dBm at two candidate places and the signals of GSM frequency bands not affect to conversional system, then it is considered as a suitable place for GSM mobile field test.

Development of FPGA Based HIL Simulator for PMS Performance Verification of Natural Liquefied Gas Carriers (액화천연가스운반선의 PMS 성능 검증을 위한 FPGA 기반 HIL 시뮬레이터 개발)

  • Lee, Kwangkook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.949-955
    • /
    • 2018
  • Hardware-in-the-loop (HIL) simulation is a technique that can be employed for developing and testing complex real-time embedded systems. HIL simulation provides an effective platform for verifying power management system (PMS) performance of liquefied natural gas carriers, which are high value-added vessels such as offshore plants. However, HIL tests conducted by research institutes, including domestic shipyards, can be protracted. To address the said issue, this study proposes a field programmable gate array (FPGA) based PMS-HIL simulator that comprises a power supply, consumer, control console, and main switchboard. The proposed HIL simulation platform incorporated actual equipment data while conducting load sharing PMS tests. The proposed system was verified through symmetric, asymmetric, and fixed load sharing tests. The proposed system can thus potentially replace the standard factory acceptance tests. Furthermore, the proposed simulator can be helpful in developing additional systems for vessel automation and autonomous operation, including the development of energy management systems.

Distance Estimation Using Convolutional Neural Network in UWB Systems (UWB 시스템에서 합성곱 신경망을 이용한 거리 추정)

  • Nam, Gyeong-Mo;Jung, Tae-Yun;Jung, Sunghun;Jeong, Eui-Rim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1290-1297
    • /
    • 2019
  • The paper proposes a distance estimation technique for ultra-wideband (UWB) systems using convolutional neural network (CNN). To estimate the distance from the transmitter and the receiver in the proposed method, 1 dimensional vector consisted of the magnitudes of the received samples is reshaped into a 2 dimensional matrix, and by using this matrix, the distance is estimated through the CNN regressor. The received signal for CNN training is generated by the UWB channel model in the IEEE 802.15.4a, and the CNN model is trained. Next, the received signal for CNN test is generated by filed experiments in indoor environments, and the distance estimation performance is verified. The proposed technique is also compared with the existing threshold based method. According to the results, the proposed CNN based technique is superior to the conventional method and specifically, the proposed method shows 0.6 m root mean square error (RMSE) at distance 10 m while the conventional technique shows much worse 1.6 m RMSE.

Development of the 80-kW Test Tractor for Load Measurement of Agricultural Operations (농작업 부하 계측을 위한 80kW급 계측 트랙터 개발 및 검증)

  • Cho, Seung-Je;Kim, Jeong-Gil;Park, Jin-Sun;Kim, Yeon-Soo;Lee, Dongkeun
    • Journal of Drive and Control
    • /
    • v.19 no.4
    • /
    • pp.46-53
    • /
    • 2022
  • RIn this study, a test tractor that could measure various types of agricultural operational loads was developed, and its performance was verified. This tractor could be used to measure the load generated during agricultural work and convert the related data into a database. A test tractor was developed using an 80-kW-rated load tractor, and it could measure various types of field test data, such as engine torque and rpm, wheel torque, PTO(power take-off) torque, hexometer, IMU/INS sensor, steering angle sensor, hydraulic pressure, and flow sensor data. To verify the developed test tractor, a verification test using an agriculture rotavator was performed. The test conditions were L1, L2, and L3 based on the tractor's main and sub-transmission stages, and stages 1 and 2 were selected as the PTO. In a comparison of the analyzed test data, similar tendencies in the test results of this research and other research (Kim's research) were seen. Through this, the developed test tractor was verified. In the future, we plan to conduct research on the tractor developed in this study using various attached working machines.

Assessing climate change response on runoff and T-N loads of rice growing season shift using coupled SWAT-APEX model (SWAT-APEX 연계 모형을 이용한 벼 생육기간 조절을 통한 기후변화 대응 영향 평가)

  • Kim, Dong Hyeon;Jan, Taeil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.200-200
    • /
    • 2020
  • 본 연구에서는 SWAT 모형과 APEX-Paddy 모형의 연계 모델링을 통한 대표 BMP(Best management practice) 적용, 정식시기 및 벼 생육기간을 고려한 시나리오 적용을 통해 농업용수의 관리 및 수질환경 개선 등에 활용할 수 있는 저영향 영농활동을 분석하고자 하였다. 만경강 유역을 대상으로 SWAT 모형을 구축하고 유역 내에 위치한 논 시험포장을 대상으로 강우-유출 및 비점오염원 모니터링 자료를 활용하여 APEX-Paddy 모형을 구축하였다. SWAT 모형과 APEX 모형을 연계하여 유역의 수문, 수질에 대한 정밀한 모델링을 수행하였으며, 이는 저영향 영농활동을 분석하기 위한 필드단위의 정확한 결과를 유역차원에 반영하기 위함이다. 특히, 본 연구에 사용된 APEX-Paddy 모형은 농촌진흥청과 Texas A&M의 공동연구를 통해 개발된 새로운 모형으로서 한국의 논 영농활동 및 담수환경을 반영하여 논에서의 유출 및 비점오염원을 모의할 수 있다. 연계 모형의 적합성 평가를 위해 R2 (Determine of Coefficient), RMSE (Root mean square error), NSE (Nash-sutcliffe efficiency)를 사용하였다. 적합성 평가 지표를 분석한 결과, 유출량은 R2 평균 0.91, RMSE 평균 2.87 mm/day, NSE 평균 0.78로 나타났다. T-N 부하량은 R2 평균 0.74, RMSE 평균 59.3 kg/ha/day, NSE 평균 0.50으로 나타났다. 저영향 영농활동 관리방안을 위한 시나리오로 1) 논의 물꼬높이(BMP) 관리 적용, 2) 벼 생육기간 조절을 고려하여 기온변화에 따른 정식시기, 벼 생육기간 등을 조정하여 적용하였다. 기후변화 시나리오는 10개 GCM 모델의 RCP 8.5 시나리오를 통해 분석하였으며, 유역차원의 미래 영향을 분석한 결과, 물꼬관리 BMP에 따라 담수심이 증가되며, 관개량이 감소하고 유출량 10.7%, T-N 11.2% 저감되는 것을 나타냈으며, 벼 생육기간 조절은 BMP보다 상대적으로 효과가 높진 않았지만, 유출량 1.4%, T-N 3.1%의 저감효과를 나타냈다. 따라서 두 가지의 저영향 영농활동 관리방안은 미래기간의 기후변화에 대응하여 농업용수 및 물관리에 도움이 될 것으로 사료된다. 하지만 본 연구결과는 모델링 결과에 의존한 것이며, 추후 지속적인 연구와 보완이 필요하다.

  • PDF

Characteristics of Beam-tilting Slot Array Waveguide Antennas for DBS Reception (DBS 수신용 빔 틸트형 슬롯 어레이 도파관 안테나의 특성)

  • Min, Gyeong-Sik;Kim, Dong-Cheol;Arai, Hiroyuki
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.3
    • /
    • pp.140-149
    • /
    • 2002
  • This paper describes the characteristics of beam-tilting slot away waveguide antennas for mobile DBS reception. As a basic study of slotted waveguide array, design for 16 slot elements located on a broad-wall waveguide is considered. Design parameters such as slot length, space between each slot and cross slot angle of antennas with the beam-tilting characteristics are calculated by method of moments. Based on these results, the radiation waveguide antennas with 16-element $\times$16-array are designed and fabricated. The measured main beam direction angles of the fabricated antennas are 48$^{\circ}$to 50$^{\circ}$depending on the measured frequencies and it shows good agreement with prediction. The measured 3 dB beam width of elevation pattern is about 13$^{\circ}$, and the axial ratio and the gain measured at DBS band are observed 2.8 dB below and 24 dBi above, respectively. In order to evaluate a performance of the fabricated waveguide planar antenna, it is combined with the satellite tracking control system and the field performance test of antenna mounted on a mobile vehicle is carried out at highway. During the measurement, it was possible to watch television without a break signal in a driving vehicle and an excellent performance of the proposed antennas was demonstrated.

Metabolic Responses of Activated Sludge to Pentachlorophenol in a SBR System (SBR 처리 장치에서 활성 슬럿지의 대사에 미치는 Pentachlorophenol의 독성 효과)

  • KIM Sung-Jae;Benefield Larry D.
    • Journal of Aquaculture
    • /
    • v.6 no.4
    • /
    • pp.323-338
    • /
    • 1993
  • The primary objective of this study was to examine the toxic effects of PCP on activated sludge and to analyze its metabolic responses while treating wastewater containing pentachlorophenol (PCP) in a sequencing batch reactor (SBR) system operating under different control strategies. This study was conducted in two phases 1 and 2 (8-hr and 12-hr cycles). Each phase was operated with two control strategies I and II. Strategy I (reactor 1) involved rapid addition (5 minutes to complete) of substrate to the reactor with continuous mixing but no aeration for 2 hours. Strategy II (reactor 2) involved adding the feed continuously during the first 2 hours of the cycle when the system was mixed but not aerated. During both phases each reactor was operated at a sludge age of 15 days. The synthetic wastewater was used as a feed. The COD of the feed solution was about 380 mg/L. After the reference response for both reactors was established, the steady state response of each system was established for PCP feed concentrations of 0.1 mg/L, 1.0 mg/L, and 5.0 mg/L in SBR systems operating on both 8-hr and 12-hr cycles. Soluble COD removal was not inhibited at any feed PCP concentrations used. At 5.0 mg/L feed PCP concentration and in SBR systems operating on phase 2, the concentrations or ML VSS were decreased; selective pressure on the mixed biomass might be increased, narrowing the range of possible ecological responses; the settleability of activated sludge was poor; the SOURs were increased, showing that the systems were shocked. Nitrification was made to some extent at all concentrations of feed PCP in SBR systems operating on phase 2 whereas in SBR systems operating on phase 1 little nitrification was observed. Then, nitrification will be delayed as much as soluble COD removal is retarded due to PCP inhibition effects. Enhanced biological phosphorus removal occurring in the system operating with control strategy I during phase 1 of this work and in the presence of low concentrations of PCP was unreliable and might cease at anytime, whereas enhanced biological phosphorus removal occurring in the system operating with either control strategy I or II during phase 2 of this work and in the presence of feed PCP concentrations up to 1.0 mg/L was reliable. When, however, such processes were exposed to 5.0 mg/L PCP dose, enhanced phosphorus removal ceased and never returned.

  • PDF