• Title/Summary/Keyword: 핀 유용성

Search Result 30, Processing Time 0.046 seconds

Chemical changes in resazurin by probiotics and its application for evaluating living bacterial cell counts and their reduction potentials (프로바이오틱스에 의한 레자주린의 화학적 변화와 생균수 및 환원활성 측정에의 적용)

  • Lee, Hyowon;Oh, Yeong Ji;Hong, Jungil
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.204-212
    • /
    • 2021
  • Resazurin, an oxidized blue dye, is reduced to resorufin, showing a peak absorbance change and emitting fluorescence due to the metabolic activity of living cells. In this study, the growth of Lactobacillus rhamnosus GG (LGG) and the redox potential of living probiotic bacteria were evaluated based on changes in the absorbance or fluorescence of resazurin. Fluorescence analysis is a more accurate and sensitive method for quantifying viable LGG than the colorimetric absorbance measurement of resazurin change. Fluorescence measurement could detect LGG of 6.5-9.5 log CFU/mL within 30 min with R2=0.99. No significant effect of further reduction of resorufin to dihydroresorufin by LGG was observed. Various probiotics showed different resazurin-reducing activities, and L. kimchicus had the highest reducing activity among the six probiotics tested. These findings suggests that fluorescence measurement in a resazurin-based assay is useful for analyzing bacterial growth and the redox potential of living probiotics.

Quantitative Analysis of 3D-CRT Radiotherapy Planning Factors with or without IR in Patients with High Density Artifacts (고밀도 인공물 환자에서 반복적 재구성 사용 유무에 따른 3차원 입체조형 방사선 치료 계획 인자의 정량분석)

  • Lee, Gyu-Wook;Choi, U-Hyeong;Jung, Yae-Hyun;Lee, Joo-Hee;Yun, In-Ha;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.7-14
    • /
    • 2020
  • The purpose of this study is to assess the usefulness of IR to compensate for uncertainties in inserting high density artificial objects in radiation treatment planning in the 3D-CRT treatment technique. CT images of the subjects with phantom and titanium inserted were obtained from images without IR and images with IR, and the dose evaluation factors HI, MU and volume evaluation factors Volume and PCI were compared. The results of the stainless steel and titanium phantom experiments showed that the volume of high density artificial material was reduced by 4.850% and 11.456% respectively when applying IR. MU decreased 0.924% and 1.181%. HI was down 0.106% and 0.272%. PCI decreased 0.358% and 0.867%. When IR was applied to CT images of subjects with vertebroplasty, Femur alignment pin and wrist alignment pin, the volume of artifacts decreased by 47.76%, 23.841%, and 49.339%. MU also decreased 0.924%, 0.294% and 1.675%, while HI decreased 1.232%, 0.412% and 1.695%. PCI decreases 4.022%, 0.512%, and 13.472%. In conclusion, When IR was applied to 3D-CRT treatment plan, both dose and volume in phantom and subject case with high density artificial insert were reduced.

Comparative Analysis of Fracture Angulation between Parallel Pinning and Plate Fixation Techniques in the Management of 5th Metacarpal Fractures (제 5 수지 중수골 골절에서 평행 핀 또는 플레이트 고정술 이후 골절각 변화에 대한 비교 연구)

  • Lee, Myungchul;Shin, Hyojung;Choi, Hyungon;Kim, Jeenam;Shin, Donghyeok
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.230-238
    • /
    • 2018
  • Purpose: Metacarpal fractures are common injuries of the hand. They are treated using closed reduction (CR) or open reduction (OR) techniques. The management strategy depends on fracture site characteristic and fixation methods. In this study, we evaluated pre- and postoperative fracture angulation, when metacarpal fractures bad been treated using two different techniques: CR with parallel transverse pinning and OR with plate fixation. Methods: Forty-six patients undergoing anatomic reduction to treat extra-articular metacarpal fractures were recruited. They were included in one of two therapeutic groups: Group 1, CR with parallel transverse pinning (n=21); Group 2, OR with plate fixation (n=25). Fracture angulation values have been measured on pre- and postoperative radiologic images. Values were compared between pre- and postoperative states, and between corresponding measurements of each group. Results: All extra-articular metacarpal fractures were successfully treated without wound related complications or the limit of joint motion. Both groups demonstrated adequate reduction at immediate postoperative period (postoperative angulation of group 1, $20^{\circ}{\pm}7^{\circ}$; group 2, $19^{\circ}{\pm}5^{\circ}$). During the observation at follow-up period, Group 1 exhibited slight recurrence (follow-up angulation of group 1, $24^{\circ}{\pm}10^{\circ}$). Nonetheless, Group 2 showed adequate reduction state in both immediate postoperative and long-term follow-up periods (follow-up angulation of group 2, $18^{\circ}{\pm}6^{\circ}$). Conclusion: Extra-articular metacarpal fractures were successfully restored without functional complications. CR with parallel transverse pinning method exhibited recurrence after pin removal, which necessitates cautious postoperative exercise and monitoring.

Application of Hinged Transarticular External Skeletal Fixator (HTAESF) for Proximal Tibial Physeal Fracture in a Dog (개의 근위 경골 성장판 골절에서 경첩 관절경유 외고정의 적용)

  • Kim, Kwan;Heo, Su-Young;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.502-505
    • /
    • 2012
  • An 8-month-old, 3.5 kg intact female Toy Poodle was presented for non-weight-bearing lameness on left hindlimb. In radiological testing, left proximal tibal type II Salter-Harris physeal fracture and fibular fracture were seen. Following open reduction, the fracture was stabilized with cross-pins, tension band wires, and a hinged transarticular external skeletal fixator (HTAESF). The range of the HTAESF was increased to $25^{\circ}$ at 7 days postsurgery and to $70^{\circ}$ at 14 days post-surgery. The HTAESF was removed 3 weeks after surgery. At 6 weeks post-surgery, the fracture was successfully healed with no complications and the patient recovered a normal gait. Seven months post-surgery, the patient had a normal gait and a normal stifle joint range of motion compared to the contralateral normal limb. This is a case in which the combined use of cross-pins, tension band wires, and HTAESF was successful for treatment of a proximal tibial physeal fracture in a dog. It is thought that these methods are beneficial for stability of fracture site and recover of joint's normal range of motion through early joint movement.

A Study on Loading Method of Large Scaffolding Module for LNG Carriers Using TRIZ (TRIZ를 이용한 LNG 운반선 대형 비계 모듈의 탑재 방안 연구)

  • Park, Myeong-Chul;Shin, Sang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.94-100
    • /
    • 2021
  • To improve the productivity of cargo containment construction for a membrane LNG carrier, it is important to shorten the installation period and process of the scaffolding system, which is a construction workbench of a cargo containment for a membrane LNG carrier. As an effective method, opinions are being gathered to enlarge the lifting unit from the existing two stages to eight stages. On the other hand, the stresses around the pin and hole will increase significantly because of the increase in lifting load according to the large size of the module. The purpose of this study was to establish a new large module-lifting plan by introducing TRIZ to solve these problems. This study adopted a method to utilize 40 inventive principles, which is one of the various problem-solving tools of TRIZ. First, technical contradictions were derived, the engineering parameters were selected. Second, efficient inventive principles were selected to overcome the technical contradictions using a contradiction matrix. Finally, the general and specific solutions were derived through the selected inventive principle, and structural analysis confirmed that the stress generated in the structure was low. The utility of TRIZ was confirmed by the successful lifting of large modules using the established lifting method.

Temporary Use of External Fixators for Soft Tissue Lengthening in the Treatment of Complications after Limb Salvage Surgery (사지 구제술 합병증 치료에서 연부조직 연장을 위한 한시적 외고정 기기의 유용성)

  • Yoon, Pil-Whan;Kang, Hyun-Guy;Kim, Kap-Jung;Oh, Joo-Han;Lee, Sang-Hoon;Lee, Sang-Ki;Kim, Han-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.134-140
    • /
    • 2005
  • Purpose: We evaluated the effectiveness of temporary using the extendible external fixator (EF) for lengthening of soft tissue that contracture caused by tumor prosthesis removal in the treatment of complications after limb salvage surgery like deep infection and loosening. Materials and Methods: Five patients six cases were included who underwent extendible EF (Dyna-extor(r)). EF was applied after insertion of half pin to the proximal and distal bone of defect area. EF lengthening started at third day of post-operation, above 2-3 mm per day in the range of no neurological sign. Results: The treatment area was three in femur and two in tibia. Mean age when the time of EF apply was 22.2 years old (range 15-29), but its primary limb salvage operation had done in 13.4 years old (range 9-19), therefore mean times of interval between initial tumor prosthesis reconstruction and temporary EF apply was 8.8 years (range 3-14). One patient had EF for 150 days with 7.2 cm lengthening. Others 5 cases of 4 patients had EF for mean 37 days (range 25-50) and mean soft tissue lengthening was 5.8 cm. Three patients underwent re-insertion of tumor prosthesis and two patients underwent knee fusion as final operation and showed no evidence of infection through mean 22 months follow up period. Conclusion: Temporary using of extendible EF is an effective method for correction of leg shortening which occurred by soft tissue contracture in the complications of limb salvage operation or their treatment process, and it could be provide easily application of tumor prosthesis and knee fusion as final operation.

  • PDF

Calibration Kit for 4-Port Horizontal/Vertical Probing (4-포트 수평/수직 겸용 프로브용 교정키트)

  • Kim, Taeho;Kim, Jonghyeon;Kim, Sungjun;Kim, Kwangho;Pu, Bo;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.559-575
    • /
    • 2014
  • In this paper, we propose a horizontal/vertical calibration kit for calibrating a vector network analyzer(VNA) to measure the vertical connector pin. If the conventional calibration kit is used, we should change the arm for a probe or need an assistant device and it takes a long time. In addition there is a risk of precision degradation caused by the position change of the probe tip sensitive to the surroundings. We suggest a 4-port vertical calibration kit to make up for the aforementioned shortcomings. The calibration kit was manufactured for the SOLT calibration method. 'Short', 'Open', and 'Load' are available in the horizontal plane, 'Thru' is available not only in the horizontal plane on the two planes of a PCB, but in the vertical plane between the two planes according to the positions of the probes. We complemented the conventional calibration kit to make a vertical calibration kit to be used for the vertical measurement method. We compared and analysed their reflection/transfer characteristics of the SOLT calibration standards of the proposed calibration kit and conventional one, we get a ${\pm}0.1$ dB differences of transfer characteristics in the range from 300 kHz to 8.5 GHz. In order to demonstrate usefulness, and we performed a case study for horizontal and vertical cases, and compared the results of the proposed calibration kit and conventional one.

Usefulness of Treatment with 6.5 mm Cancellous Screw and Steinmann Pin Fixation for Calcaneal Joint Depression Fracture (종골의 관절 함몰 골절에서 6.5 mm 해면골 나사와 Steinmann 핀을 이용한 치료의 유용성)

  • Lee, Gi-Soo;Kang, Chan;Hwang, Deuk-Soo;Noh, Chang-Kyun;Lee, Gi-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • Purpose: To report the radiographic and clinical results of 6.5 mm cancellous full threaded buttress screw or Steinmann pin fixation to maintain a reduction of calcaneal posterior facet depression fracture. Materials and Methods: From June 2009 to June 2012, 50 consecutive cases with calcaneal joint depression fracture that underwent open reduction and screw or pin fixation were enrolled in this study. A 6.5 mm cancellous full threaded screw was inserted from the posteroinferior aspect of the calcaneal tuberosity to the posterior facet (group A) or Steinman pin was inserted from the posterosuperior aspect of the calcaneal tuberosity to the calcaneocuboidal joint (group B). Both preoperative and postoperative Bohler and Gissane angles were measured radiographically, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale on the final follow-up were assessed. Results: The mean age of patients was 44.1 years, and the mean follow-up period was 27.2 months. According to the Sanders classification, 28 cases were type II and 22 cases were type III. In Sanders type II, Bohler and Gissane angles improved significantly from $10.1^{\circ}$ and $126.2^{\circ}$ preoperatively to $27.2^{\circ}$ and $117.1^{\circ}$, respectively, in the immediate postoperative radiograph, and at the final follow-up, $26.6^{\circ}$ and $118.6^{\circ}$, respectively. In Sanders type III, Bohler and Gissane angles improved significantly from $5.0^{\circ}$ and $129.8^{\circ}$ to $29.9^{\circ}$ and $119.3^{\circ}$, respectively, in the immediate postoperative radiograph, and $26.9^{\circ}$ and $120.2^{\circ}$ at the final follow-up. All cases achieved bony union, and the average period until complete union was 13.3 weeks. AOFAS ankle-hindfoot scale was 82.6 in Sanders type II and 77.3 in Sanders type III at the final follow-up. Conclusion: A 6.5 mm cancellous full threaded buttress screw or Steinman pin fixation is a noninvasive treatment method with a merit of being able to maintain the bearing capacity of the posterior facet comparable to plate fixation.

Percutaneous Mini-open Reduction for Mason II or III Radial Head and Neck Fracture (요골 두 및 경부 골절의 경피적 도수 정복술)

  • Lee, Jeong-Gil;Koh, Il-Hyun;Kim, Hyung-Sik;Choi, Yun-Rak;Kim, Sung-Jae;Kang, Ho-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.230-236
    • /
    • 2010
  • Purpose: We wanted to evaluate the result of percutaneous, mini-open reduction for the treatment of Mason II or III radial head and neck fractures. Materials and Methods: 13 patients (8 male, 5 female) with Mason II or III radial head and neck fractures were treated by 1 cm percutaneous mini-open reduction under fluoroscopy. The average age of our subjects was 29 years. Follow up duration was 18 months. Results: Union was noted in all cases. Mean radial neck angulation was decreased from 33.2 degrees to 7.8 degrees. The mean change in angulation between the immediate post-operative and last follow-up was 0.7 degrees. The mean range of motion at the elbow joint was at last follow up, 133.1 degrees in flexion, 7.3 degrees in extension, 80 degrees in pronation and 84.3 degrees in supination. Postoperatively, mean Mayo Elbow Performance Index, American Shoulder and Elbow Surgeons elbow score, and Disabilities of the Arm, Shoulder and Hand score were 96.2, 97 and 1.2. Temporary posterior interosseous nerve palsy (1 case) and minimal cubitus valgus deformity (1 case) were noted. Conclusion: Selected Mason II or III radial head and neck fractures can be treated satisfactorily with percutaneous mini-open reduction.

CHEMOPREVENTION OF COLON CANCER BY THE KOREAN FOOD STUFFS COMPONENTS

  • Kim, Dae-Joong;Shin, Dong-Hwan;Ahn, Byeong-Woo;Jang, Dong-Deuk;Hiroyuki Tsuda;Shoji Fukushima
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.05b
    • /
    • pp.106.2-132
    • /
    • 2002
  • 형질전환 (유전자 결핍; Knockout) Min 마우스를 이용하여 대장암 발생에서 배추, 양배추 주성분인 indole-3-carbinol (I3C)의 대장암 예방효과를 규명하고자 하였다. 실험동물로는 C57BL/6J-Apc$^{min/+}$(Min 마우스)계의 5내지 6주령의 수컷 이형접합체 형질전환 마우스 70마리와 C57BL/6J계의 동일 산자, 동일 주령의 수컷 wildtype 비형질전환 마우스 10kfl를 The Jackson Laboratory 사 (Bar harber, ME, USA)로부터 직접 구입하였다. C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 (Min)마우스 70마리를 각 군 20내지 25마리씩 세군으로 나누었다. Group 1에는 20마리, Group 2에는 25마리, Group 3에는 25마리를 배치하고, I3C 투여 실험군 (Group 1과 2)에는 실험시작시에 AIN-76A 분말사료에 I3C가 각각 100 및 300ppm이 함유되도록 조제하여 공급하였다. 그리고 실험군(Group 3)에는 실험시작부터 종료시까지 AIN-76A 정제고형사료(Teklad사, WI, USA)를 자유로이 급이하였다. 각군간의 체중, 사료 및 음수소비량을 매 2주마다 측정하였고, 10주간 (16주령)의 실험종료시에는 최종체중과 간장, 신장, 비장 등의 장기무게를 측정하여 상대장기 무게비를 산출하였다. 대조군으로서 C57BL/6J계의 동일 산자, 동일 주령의 수컷 wildtype 비형질전환 마우스 10마리는 같은 조건의 사육실에서 AIN-76A 정제고형사료를 33주간 자유로이 급이하였다. 실험동물은 부검전에 하룻밤 동안 절식하고 이산화탄소 흡입 마취하에서 흉대동맥을 절단하여 방혈하고 각 장기(심장, 폐, 위)를 적출하여 생리심염수에 넣어 장기무게를 측정하고 포르말린에 고정하였다. 소장과 대장의 검사를 위하여 위의 식도부위와 직장을 실로 결찰하여 적출하고 생리심염수를 주입하여 팽창시켜, 십이지장, 공장, 및 회장, 그리고 대장으로 나누어 여과지에 펼친 후 포르말린에 고정하였다. 소장과 대장은 육안 및 자동 영상분석길ㄹ 이용한 분석이 끝난 후에 각 부위별로 4-6개의 절편을 작제하여 포르말린에 재고정하고, 통상적인 조직처리과정, 파리핀 포매 및 3-4$\mu$m 두께의 조직절편을 제작하여 H&E 염색을 실시하여 현미경으로 검경하였다. 약 1주일간의 포르말린 고정이 끝난 소장 및 대장을 부위별, 별 종양개수 및 분포를 자동영상분석기(Kontron Co. Ltd., Germany)로 분석하였다. 체의 변화, 장기무게, 사료소비량 및 마리당 종양의 개수에 대한 통계학적 유의성 검증을 위하여 Duncan's t-test로 통계처리 하였고, 종양 발생빈도에 대하여는 Likelihood ration Chi-square test로 유의성을 검증하였다. C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스에 AIN-76A 정제사료만을 투여한 대조군의 대장선종의 발생률은 84%(Group 3; 21/25례)로써 I3C 100ppm 및 300ppm을 투여한 경우에 있어서는 각군 모두 60%(Group 1; 12/20 례, Group 2; 15/25 례)로 감소하는 경향을 나타내었다. 대장선종의 마리당 발생개수에 있어서는 C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스에 AIN-76A 정제사료만을 투여한 대조군은 1.40$\pm$0.24(100%)에 비하여 I3C 저농도 투여 실험군(Group 1; 0.85$\pm$0.23; 61%, P<0.01), 그리고 I3C 고농도 투여 실험군(Group 2 ; 1.32$\pm$0.29 ; 94%)의 순으로 감소하였다. 선종의 크기별 종양의 발생개수의 분포에 있어서 I3C 저농도 투여 실험군에 있어서는 선종의 크기가 3mm이하의 수가 현저하게 감소하였다. C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스에 AIN-76A 정제사료만을 투여한 대조군의 부위별 소장선종의 발생수는 십이지장부위를 제외하고 각 군에서 유의한 변화는 관찰되지 않았다. 십이지장 종양의 발생개수에서만 I3C 저농도 투여 실험군(Group 1 ; 3.11$\pm$0.85)이 대조군 (Group 3: 1.48$\pm$0.35) 및 I3C 고농도 투여 실험군(Group 2: 1.56$\pm$0.47)에 비하여 유의성 있게 증가하였다. (P<0.05). 따라서 I3C은 소장에서는 암예방 효과가 뚜렷하지 않으나, 대장에 대한 암에방 효과가 있을 것으로 생각된다. 소장 및 대장을 제외한 간장, 신장, 비장, 심장, 폐 그리고 위 등의 기타 장기에서의 조직병리학적 변화는 관찰되지 않았다. 소장 및 대장의 종양은 선종(polyps)으로 관찰되었다. 지난 10여년간 형질전환 및 유전자 결핍 실험동물의 종류가 기하 급수적으로 증가하여 이용되고 있다. 가족성 대장 선종성 용종증(FAP)의 대표적인 모델로 이용되고 있는 C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스를 사용하여 배추나 양배추의 주요성분인 Indole-3-carbinol(I3C)의 대장암 예방효과가 있는지를 검색하여 본 결과 AIN-76A정제사료만을 투여한 대조군의 대장선종의 발생률 84%에 비하여 I3C 100 및 300ppm을 투여한 실험군에 있어서 각군 모두 60%로서 감소하는 경향을 나타내었으며, 대장선종의 마리당 발생개수에 있어서는 대조군의 1.40$\pm$1.041를 100%로 환산하였을 경우 I3C 저농도 및 고농도 투여 실험군에서는 각각 약 61%와 94%를 나타내여 감소하였다. 특히 대장선종의 크기별 분포에 있어서 선종의 크기가 3mm이하의 수가 현저하게 감소하였다. 따라서 저농도 I3C의 투여는 실험적 유전성 가족성 대장 선종성 용종증 모델에 있어서 어느정도 암 예방효과가 있는 것으로 생각된다. 그러나 소장 선종의 발생에는 별 영향이 없는 것으로 생각된다. 그러나 본 실험에 사용된 C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스는 실험개시 시점이 7내지 8주령이 경과하여 이미 태생기부터 소장 및 대장의 선종 발생이 진행되어 온 것을 감안하고 특히 비스테로이드계 항염증 소염제(NSAIDS)와 같은 강력한 COX-2억제제가 아님을 고려하면, 상당한 선종의 발생을 억제할 수 있는 가능성이 매우 높다고 생각한다. 또한 이제까지 배추나 양배추 성분의 복합성분들에 대한 실험적 대장암 모델에서의 촉진효과 등에 대한 보고들이 있어 온 점을 고려할 때 위암(Kim 등, 1994) 간암(Kim 등, 1994), 유방암(Grubbs, 등, 1995; Bradlow 등, 1995)에 대한 예방효과가 있을 것으로 생각된다. 앞으로 이러한 종양조직내에서의 COX-2 및 iNOS mRNA와 단백질의 발현정도를 분자병리학적으로 연구중에 있으며, 향후 십자화과식물 성분인 indole-3-carbinol이 마우스뿐 만 아니라 랫드의 화학발암물질에 의한 대장종양에 대한 억제효과 있는지 연구 필요가 있다. Min 마우스와 같은 형질 전환(유전자결핍;knockout) 실험동물을 이용한 새로운 중기 발암성 시험범의 확립을 통한 각종 환경 유해물질의 발암성 유무 및 COX-2 억제작용이 있는 식품인자의 암예방 후보물질을 체계적으로 검색하는데 유용하게 활용될 수 있을 것으로 생각한다.

  • PDF