• Title/Summary/Keyword: 피크검출

Search Result 316, Processing Time 0.03 seconds

Automatic Determination of the Energy Pulse-height Relationship in NaI(TI) Spectra (NaI(T1) 검출기 스펙트럼의 에너지-채널 관계 자동결정)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.143-151
    • /
    • 1997
  • As the pulse heights from a NaI(Tl) detector vary with the temperature of the measuring environment a significant change in temperature may affect the energy calibration of the spectrometer. The auto-adjustment of the channel corresponding to a pulse heights can be achieved by introducing an external reference source to compensate the temperature dependency of pulse heights, but unfavorable increases of the Compton continuum are caused due to the external source. In this study, the total absorption peaks dominant in the typical environmental gamma spectrum-239 keV from $^{212}Pb$, 351 keV from $^{214}Pb$, 1460 keV from $^{40}K$ and 2614 keV from $^{208}Tl$ for examples - were used as reference in the correction of energy calibration. With these peaks, the program to calibrate the energy of the s spectrum was developed using Microsoft Visual Basic language. The program developed here was applied to the environmental spectra measured at intervals of 30 minutes in the temperature range of from $-20^{\circ}C$ to $10^{\circ}C$ to demonstrate the validity and applicability. As a result of the test, the correction scheme appeared to be effective in the temperature changes encountered in the usual environment.

  • PDF

Premature Ventricular Contraction Classification through R Peak Pattern and RR Interval based on Optimal R Wave Detection (최적 R파 검출 기반의 R피크 패턴과 RR간격을 통한 조기심실수축 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.233-242
    • /
    • 2018
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require higher computational cost and larger processing time. Therefore it is necessary to design efficient algorithm that classifies PVC(premature ventricular contraction) and decreases computational cost by accurately detecting feature point based on only R peak through optimal R wave. For this purpose, we detected R wave through optimal threshold value and extracted RR interval and R peak pattern from noise-free ECG signal through the preprocessing method. Also, we classified PVC in realtime through RR interval and R peak pattern. The performance of R wave detection and PVC classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30. The achieved scores indicate the average of 99.02% in R wave detection and the rate of 94.85% in PVC classification.

Comparative Study of the Symbol Rate Detection of Unknown Digital Communication Signals (미상 디지털 통신 신호의 심볼율 검출 방식 비교)

  • Joo, Se-Joon;Hong, Een-Kee
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.2
    • /
    • pp.141-148
    • /
    • 2003
  • This paper presents and compares several techniques that detect the symbol rate of unknown received signal. Symbol rate is detected from the power spectral density of the circuits such as the delay and multiplier circuit, the square law circuit, and analytic signal, etc. As a result of discrete Fourier transform of the output signals of these circuits, a lot of spectral lines and some peaks appear in frequency domain and the position of first peak is corresponding to the symbol rate. If a spectral line on the frequency that is not located in symbol rate is larger than the first peak, the symbol rate is erroneously detected. Thus, the ratio between the value of first peak and the highest side spectral line is used for the measure of the performance of symbol rate detector. For the MPSK modulation, the analytic signal method shows better performance than the delay and multiplier and square law circuits when the received signal power is lager than -20dB. It is also noted that the delay and multiplier circuit is not able to detect the symbol rate for the QAM modulation.

  • PDF

Integrated Circuit of a Peak Detector for Flyback Converter using a 0.35 um CMOS Process (0.35 um CMOS 공정을 이용한 플라이백 컨버터용 피크검출기의 집적회로 설계)

  • Han, Ye-Ji;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.42-48
    • /
    • 2016
  • In this paper, a high-precision peak detector circuit that detects the output voltage information of a fly-back converter is proposed. The proposed design consists of basic analog elements with only one operational amplifier and three transistors. Because of its simple structure, the proposed circuit can minimize the delay time of the detection process, which has a strong impact on the precision of the regulation aspect of the fly-back converter. Furthermore, by using an amplifier and several transistors, the proposed detector can be fully integrated on-chip, instead of using discrete circuit elements, such as capacitors and diodes, as in conventional designs, which reduces the production cost of the fly-back converter module. In order to verify the performance of the proposed scheme, the peak detector was simulated and implemented by using a 0.35 m MagnaChip process. The gained results from the simulation with a sinusoidal stimulus signal show a very small detection error in the range of 0.3~3.1%, which is much lower than other reported detecting circuits. The measured results from the fabricated chip confirm the simulation results. As a result, the proposed peak detector is recommended for designs of high-performance fly-back converters in order to improve the poor regulation aspect seen in conventional designs.

Synchronization Method in PJM Mode of 13.56 MHz RFID (13.56MHz RFID PJM 모드의 동기화 방법)

  • Youn, Jae-Hyuk;Yang, Hoon-Gee;Yang, Sung-Hyun;Kang, Bong-Soon;Bae, Ji-Hoon;Choi, Gil-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12B
    • /
    • pp.1506-1513
    • /
    • 2009
  • This paper presents a synchronization method to determine the exact demodulation time using the MFM Flag of the 18000-3 PJM mode, along with the hardware structure to implement the proposed method. The proposed system detects an incipient peak using ITS(Initial Time Selector) and a correlator and achieves the final synchronization via identifying the peak position from the comparison of the outputs of two followed additional correlators. The peak detection algorithm and the choice of the templates of the correlators are described. Simulation results show that the proposed system performs successfully in noisy environment.

Development of a Spectrum Analysis Software for Multipurpose Gamma-ray Detectors (감마선 검출기를 위한 스펙트럼 분석 소프트웨어 개발)

  • Lee, Jong-Myung;Kim, Young-Kwon;Park, Kil-Soon;Kim, Jung-Min;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2010
  • We developed an analysis software that automatically detects incoming isotopes for multi-purpose gamma-ray detectors. The software is divided into three major parts; Network Interface Module (NIM), Spectrum Analysis Module (SAM), and Graphic User Interface Module (GUIM). The main part is SAM that extracts peak information of energy spectrum from the collected data through network and identifies the isotopes by comparing the peaks with pre-calibrated libraries. The proposed peak detection algorithm was utilized to construct libraries of standard isotopes with two peaks and to identify the unknown isotope with the constructed libraries. We tested the software by using GammaPro1410 detector developed by NuCare Medical Systems. The results showed that NIM performed 200K counts per seconds and the most isotopes tested were correctly recognized within 1% error range when only a single unknown isotope was used for detection test. The software is expected to be used for radiation monitoring in various applications such as hospitals, power plants, and research facilities etc.

An Enhanced Step Detection Algorithm with Threshold Function under Low Sampling Rate (낮은 샘플링 주파수에서 임계 함수를 사용한 개선된 걸음 검출 알고리즘)

  • Kim, Boyeon;Chang, Yunseok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.2
    • /
    • pp.57-64
    • /
    • 2015
  • At the case of peak threshold algorithm, 3-axes data should sample step data over 20 Hz to get sufficient accuracy. But most of the digital sensors like 3-axes accelerometer have very low sampling rate caused by low data communication speed on limited SPI or $I^2C$ bandwidth of the low-cost MPU for ubiquitous devices. If the data transfer rate of the 3-axes accelerometer is getting slow, the sampling rate also slows down and it finally degrades the data accuracy. In this study, we proved there is a distinct functional relation between the sampling rate and threshold on the peak threshold step detection algorithm under the 20Hz frequency, and made a threshold function through the experiments. As a result of experiments, when we apply threshold value from the threshold function instead of fixed threshold value, the step detection error rate can be lessen about 1.2% or under. Therefore, we can suggest a peak threshold based new step detection algorithm with threshold function and it can enhance the accuracy of step detection and step count. This algorithm not only can be applied on a digital step counter design, but also can be adopted any other low-cost ubiquitous sensor devices subjected on low sampling rate.

Feature detection of peaks of sound signal using MEM (최대 엔트리법을 이용한 음향 신호의 특징 피크의 검출)

  • 성종훈;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.11a
    • /
    • pp.562-564
    • /
    • 1998
  • 보통 음향 신호를 분석을 할 때에 시간영역의 신호를 주파수영역의 신호로 FFT 변환을 해서 분석을 한다. 이렇게 단순히 FFT를 해서 주파수영역의 신호에서 어떤 특징적인 점을 찾기가 매우 어렵다. 그래서 원 신호를 FFT를 하지 않고 선형 예측 분석이라는 방법을 적용하여 신호에 특징적인 피크 점들을 구하면 쉬운 방법이 된다. 본 논문에서는 이러한 음향의 신호를 분석을 할 때에 선형 예측 분석법을 이용하면 신호에서 특징적인 피크들을 구하기가 용이함을 보이고 신호의 특징 피크 점들을 통계적으로 처리하여 분석을 해보았다.

  • PDF

Noise-robust electrocardiogram R-peak detection with adaptive filter and variable threshold (적응형 필터와 가변 임계값을 적용하여 잡음에 강인한 심전도 R-피크 검출)

  • Rahman, MD Saifur;Choi, Chul-Hyung;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.126-134
    • /
    • 2017
  • There have been numerous studies on extracting the R-peak from electrocardiogram (ECG) signals. However, most of the detection methods are complicated to implement in a real-time portable electrocardiograph device and have the disadvantage of requiring a large amount of calculations. R-peak detection requires pre-processing and post-processing related to baseline drift and the removal of noise from the commercial power supply for ECG data. An adaptive filter technique is widely used for R-peak detection, but the R-peak value cannot be detected when the input is lower than a threshold value. Moreover, there is a problem in detecting the P-peak and T-peak values due to the derivation of an erroneous threshold value as a result of noise. We propose a robust R-peak detection algorithm with low complexity and simple computation to solve these problems. The proposed scheme removes the baseline drift in ECG signals using an adaptive filter to solve the problems involved in threshold extraction. We also propose a technique to extract the appropriate threshold value automatically using the minimum and maximum values of the filtered ECG signal. To detect the R-peak from the ECG signal, we propose a threshold neighborhood search technique. Through experiments, we confirmed the improvement of the R-peak detection accuracy of the proposed method and achieved a detection speed that is suitable for a mobile system by reducing the amount of calculation. The experimental results show that the heart rate detection accuracy and sensitivity were very high (about 100%).

Development of a simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector (HPGe 검출기를 사용한 감마분광분석계의 점검선원 개발)

  • Lee, Mo Sung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.119-123
    • /
    • 2013
  • A simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector was developed. The check source consists of radium-riched soil which was ground in size of less than 0.154mm and contained in air tight cylinderical vial, and provides photons with 12 distinct energies. The spectra of the check source were measured once a month during one year, analyzed the charactreictics of their peaks. When the gamma spectrometry system was in normal state, the areas and FWHMs of the gamma rays with more than 3% gamma emission rate in radium and its decay products was constant within standard deviation 2% and 3%, respectively, except 77 keV peak. And it was found that this check source can play a sufficient role to check the integrity of a gamma spectrometry system using 10 peaks in the range of 77 to 2202 keV.