• Title/Summary/Keyword: 피부 전도도

Search Result 97, Processing Time 0.024 seconds

Development of bio-inspired hierarchically-structured skin-adhesive electronic patch for bio-signal monitoring (생체정보 진단을 위한 생체모사 계층구조 기반 피부 고점착 전자 패치 개발)

  • Kim, Da Wan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.749-754
    • /
    • 2022
  • High adhesion and water resistance of the skin surface are required for wearable and skin-attachable electronic patches in various medical applications. In this study, we report a stretchable electronic patch that mimics the drainable structure pattern of the hexagonal channels of frog's pads and the sucker of an octopus based on carbon-based conductive polymer composite materials. The hexagonal channel structure that mimics the pads of frogs drains water and improves adhesion through crack arresting effect, and the suction structure that mimics an octopus sucker shows high adhesion on wet surfaces. In addition, the high-adhesive electronic patch has excellent adhesion to various surfaces such as silicone wafer (max. 4.06 N/cm2) and skin replica surface (max. 1.84 N/cm2) in dry and wet conditions. The high skin-adhesive electronic patch made of a polymer composite material based on a polymer matrix and carbon particles can reliably detect electrocardiogram (ECG) in dry and humid environments. The proposed electronic patch presents potential applications for wearable and skin-attachable electronic devices for detecting various biosignals.

Detection of Gastric Contraction in Electrogastrography: Spectrum Analysis and Vector Analysis (위전도에서의 위수축 측정방법 : 주파수영역분석 및 벡터분석)

  • Kim, In-Young;Han, Wan-Taek
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.273-283
    • /
    • 1997
  • Electrogastrography(EGG), the cutaneous recording of the myoelectrical activity of the stomach using surface electrodes, is attactive due to its non-invasiveness. Despite many attempts made over the decades, analysis of surface EGG has not led to identification of contraction-related electrical response activity of the stomach that would help the clinician to diagnose motility disorders of the stomach. We propose feasible methods to detect the gastric contraction by spectrum analysis and vector analysis of the surface EGG signal. A running spectral analysis(RSA) based on the fast Fourier transform (FFT) was applied to the filtered EGG signal. The powers of dominant frequency and its harmonics were compared with gastric contraction signals such as the strain gauge signal from the gastric serosa in dog or the antropyloric pressure in human. And we also carried out vector analysis of the filtered EGG signals obtained from three paired electrodes. The amplitude and direction of the calculated EGG vector were analyzed and compared with the gastric contraction signals. From the spectrum analysis, we found that the increase of the power of the first harmonic of the dominant frequency was highly correlated with the gastric contraction. And from the vector analysis of the EGG signal, we found a typical change of the amplitude and direction of the EGG vector, which can indicate occurrences of the gastric contraction.

  • PDF

Effects of Topical Anesthetic Cream on Pain at Venipuncture in Children (정맥 천자 시 국소마취크림 도포가 아동의 통증에 미치는 효과)

  • Kim, Yunsoo;Park, Ho Ran
    • Child Health Nursing Research
    • /
    • v.20 no.3
    • /
    • pp.142-148
    • /
    • 2014
  • Purpose: This study was done to evaluate the effectiveness of EMLA cream on pain related to venipuncture among children. Methods: In this study, 48 children were evaluated using a sequential measurement for level of pain by Skin Conductance Level (SCL) based on Galvanic Skin Response (GSR), heart rate, and the Visual Analogue Scale (VAS) at four times. Results: The maximum and mean of the SCL were each significantly different between the experimental and control groups and furthermore, the two were also significantly different among observed times. In addition there was a significant interaction between group and time. The children's perceived pain using VAS was not significantly different between the experimental and control groups. There was no significant difference in the heart rate between the experimental and control groups; however, the interaction between group and time was significant. Conclusion: In conclusion, applying topical anesthetic cream to the venipuncture site to reduce pain was effective among the children and therefore it is highly recommended that topical anesthetic cream be applied at the venipuncture site as a nursing intervention to reduce pain when a child has to undergo a venipuncture.

Design and Implementation of Mobiel Terminal with Multi Bio-signal Measurement for u-Healthcare System (u-헬스케어 시스템에서 멀티 생체신호 측정 무선 단말기 설계 및 구현)

  • Jang, M.S.;Eom, S.H.;Kim, P.S.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.27-34
    • /
    • 2013
  • Most of existing biomedical signal measurement devices measure and evaluate biomedical signal only in a single device. Also, even if the device is multi-functional, those biomedical signals can be measured by selection of the user. In this paper, we implemented wristband-style biomedical signal measurement device for u-healthcare system to solve the problem above. Implemented device uses 4 infrared sensors to measure the pulse, 2 electrodes to measure the skin conductivity, and 3-axis accelerometer to measure momentum. Also, we propose a communication packet frame for transmitting biomedical signal data to PC or mobile device, using Zigbee. Studies show that our device has the error rate of less than twice for pulse measurement, 85.6%, 84.7% reliability for momentum measurement, and the skin conductivity has changed according to the user's physical status.

  • PDF

A Study on Ubiquitous Psychological State Recognition Model Using Bio-Signals (생체정보를 이용한 유비쿼터스 심리상태 인식 모델 연구)

  • Chon, Ki-Hwan;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.232-243
    • /
    • 2010
  • In this paper, various physiological signals of humans were measured and analyzed to inference their psychological state and biological information, and Bio-Signal Context aware system (BSC), which recognizes the current context of its users as well as the information of exterior environment and offers the service appropriate for them, was designed and implemented. The BSC extracts and analyzes the features from bio-signals, such as the measured electroencephalogram (EEG), electrocardiogram (ECG), and galvanic skin response (GSR), with its different sensors, has the input of the analyzed results, and discriminates four psychological states of rest, concentration, tension and melancholy. In addition to the results of the discriminated psychological states, the information of biological condition analyzed from the user's bio-signals, for example, heart rate variability (HRV), Galvanic skin response (GSR) and body temperature, and the information of external environment related to the user's are collected to offer the service fit for the user's present biological condition by inferring and recognizing the user's present situation.

Psychophysiological Responses to the Sound of fabric Friction (직물 마찰음에 대한 심리생리적 반응)

  • 조자영;이은주;손진훈;조길수
    • Science of Emotion and Sensibility
    • /
    • v.4 no.2
    • /
    • pp.79-88
    • /
    • 2001
  • The objectives of this study were to investigate the relationship of sound parameters with subjective sensation and physiological responses, and to figure out the interrelationship between the subjective sensation and physiological responses. Sound parameters calculated were LPT, ΔL, Δf, loudness[Z], and sharpness[Z]. Subjective sensation was evaluated in 7 aspects(soft-hard, loud-quiet, pleasant-unpleasant, sharp-dull, clear-obscure, rough-smooth, high-low) by thirty participants. We acquired physiological responses when each fabric sound was presented to 10 participants. Physiological signals obtained in this study were electroencephalogram(EEG), pulse volume(PV), skin conductance level(SCL), and LF/HF of heart rate variability. The larger the values of loudness[Z] and LPT, the louder and the rougher the subjective sensation of the perceived fabric sound. Also, the larger the values of loudness[Z] and LPT, the harder, the duller, and the less pleasant. As LPT increased, PV decreased. Loudness[Z] increased in proportion to SCL and so did sharpness[Z] to LF/HF. As the sound perceived to be quieter and clearer, the relative power of slow alpha rose. As the sound perceived to be more pleasant and smoother, PV rose.

  • PDF

Psychophysiologic Response in Patients with Panic Disorder (공황장애환자의 정신생리적 반응)

  • Chung, Sang-Keun;Cho, Kwang-Hyun;Jung, Ae-Ja;Park, Tae-Won;Hwang, Ik-Keun
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.1
    • /
    • pp.52-58
    • /
    • 2001
  • Objectives: An Increased level of psychophysiologic arousal and diminished physiologic flexibility would be observed in patients with panic disorder compared with a normal control group. We investigated the differences of psychophysiologic response between patients with panic disorder and normal control to examine this hypothesis. Methods: Ten Korean patients with panic disorder who met the diagnostic criteria of DSM-IV were compared with 10 normal healthy subjects. In psychological assessment, levels of anxiety and depression were evaluated by State-Trait Anxiety Inventory, Beck's Depression Inventory and Hamilton Rating Scale For Anxiety and Depression. Heart rate, respiration rate, electrodermal response, and electromyographic activity were measured by biofeedback system (J & J I-330 model) to determine psychophysiologic responses on autonomic nervous system. Stressful tasks included mental arithmetic, video game, hyperventilation, and talking about a stressful event. Psychophysiologic responses were measured according to the following procedures : baseline(3 min)-mental arithmetic (3 min)-rest (3 min)-video game (3 min)-rest (3 min)-hyperventilation (3 min)-rest (3 min)-talking about a stressful event (3 min). Results: The baseline level of anxiety and depression, electrodermal response (p=.017), electromyographic activity (p=.047) and heart rate (p=.049) of patients with panic disorder were significantly higher than those of the normal subject group. In electrodermal response, patient group had significantly higher startle response than the control group during hyperventilation (p=.001). Startle and recovery responses of heart rate in the patient group were significantly lower than responses in the control group during mental arithmetic (p=.007, p=.002). In electrodermal response of the patient group, startle response was significantly higher than recovery response during mental arithmetic (p=.000) and video game task (p=.021). Recovery response was significantly higher than startle response in respiratory response during hyperventilation. Conclusion: The results showed that patients with panic disorder had higher autonomic arousal than the control group, but the physiologic flexibility was variable. We suggest that it is helpful for treatment of panic disorder to decrease the level of autonomic arousal and to recover the physiologic flexibility in certain stressful event.

  • PDF

Psychophysiological Characteristics of Chronic Pain Patients Measured by Biofeedback System (바이오피드백을 이용하여 측정한 만성통증 환자의 정신생리적 특징)

  • Lee, Jin-Seong;Kang, Do-Hyung;An, Hyun-Ju;Yoon, Dae-Hyun;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.16 no.2
    • /
    • pp.79-84
    • /
    • 2009
  • Objectives: Chronic pain is one of the most common experiences of humans and a typical psychophysiological disorder. The aim of this study was to measure the psychophysiological responses in chronic pain patients using a biofeedback system, and to compare them with the results from normal healthy subjects. Methods: Forty two patients with chronic pain (17 males and 25 females, average age $44.67{\pm}11.10$ years) and 42 normal healthy controls (17 males and 25 females, average age $45.17{\pm}10.46$ years) participated in this study. Electromyography (EMG), skin conductance (SC), and skin temperature (ST) were recorded using biofeedback system during the 3 phases (baseline, stress, and recovery) of stress reactivity test, and average values of them were calculated. Difference of values between two groups in each corresponding phase was analyzed with independent t-test, and change of values across phases of stress reactivity test was analyzed with paired t-test (all two-tailed, p<0.05). Results: Compared to normal controls, chronic pain patients had higher value of EMG (baseline: $8.10{\pm}5.97{\mu}V$ vs $4.72{\pm}1.52{\mu}V$, t=-3.56, p<0.01; stress: $11.25{\pm}6.89{\mu}V$ vs $8.49{\pm}4.78{\mu}V$, t=-2.13, p<0.05; recovery: $7.12{\pm}3.77{\mu}V$ vs $4.78{\pm}1.59{\mu}V$, t=-3.70, p<0.01) and SC (baseline: $1.06{\pm}1.0{\mu}S$ vs $0.42{\pm}0.29{\mu}S$, t=-4.0. p<0.01; stress: $1.87{\pm}2.05{\mu}S$ vs $1.03{\pm}0.86{\mu}S$, t=-2.47, p<0.05; recovery: $1.74{\pm}1.77{\mu}S$ vs $0.64{\pm}0.59{\mu}S$, t=-3.8, p<0.01) in all the 3 phases. But, skin temperature comparison did not reveal significant differences in all the 3 phases between two groups. Conclusion: Psychophysiological responses of chronic pain patients in stress reactivity test were different from those of normal healthy controls. These results suggest that sympathetic nervous system is more activated in chronic pain patients.

  • PDF

First-Person Shooter Player Analysis System Based on Biometrics (생체 정보 기반 1인칭 슈팅 게임 플레이어 분석 시스템)

  • Kim, Dong-Gyun;Bae, Byung-Chull;Kang, Shin-Jin
    • Journal of Korea Game Society
    • /
    • v.17 no.6
    • /
    • pp.29-38
    • /
    • 2017
  • Predicting the user's reaction to the game at the stage of developing the game is important because it is related to the popularity of the game. In this paper, we propose a system that can collect and analyze game user's biometric information in a non-invasive way. To this end, we developed a mouse with skin conductance, pressure, gyroscope, and accelerometer sensor using Arduino. In order to verify the usefulness of this system, the subject was experimented with playing the first person shooter game with this mouse. We analyzed the gameplay videos recorded during Blizzard's 'OverWatch' and the bio-information collected from various sensors in the mouse.

A Study on Visual and Auditory Emotion under Color and Music Stimuli (색과 음악 자극에 의한 시청각 감성지표에 관한 연구)

  • 김남균;김지훈;유충기
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.539-546
    • /
    • 1998
  • The purpose of this study is to estimate human emotion quantitatively under colors and music stimuli and to examine the for correlation between color and music sensibility. Physiological signals(electroencephalogram, electrocardiogram, Galvanic skin conductivity and respiration rate) were measured to compare color with music sensibilities. The personality of the subject were investigated using factor analysis and semantic differential method of 20 items(7 interval scaled). The results showed that red, yellow and violets color provoked active and exciting senses mainly as dance, rock and blues music. While blue, cyan and pink colors ware involved in tranquil and resting emotions deeply as classic and ballade music.

  • PDF