• Title/Summary/Keyword: 피난특성

Search Result 221, Processing Time 0.023 seconds

A Study on the Main Characteristics and Factors of the Process of Beginning Egress during the Fire at the Buildings - Focus on Overseas Fire Cases including the Japanese - (건축물 화재 시 피난개시과정의 주요 특성 및 요소에 관한 연구 - 일본 등 해외 화재사례를 중심으로 -)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.59-68
    • /
    • 2012
  • Predicting occupants' behaviors from the start of the fire to egress and reducing the time required for such process are critical matters that can decide success and failure of safe egress. In this research, research literatures and theories and fire cases were compared and analyzed so as to prepare logical grounds that could predict the process of beginning egress. As a result of this research, there was a significant difference in the time elapsed until people start evacuating due to spatial positions and quarantine from the place from which the fire originated and their auditive and olfactory signs did not recognize the fire instantly and they showed a strong tendency to recognize the fire by visual sign, warning announcement for egress and notice by others. And the results also showed that only a very small minority of occupants evacuated as soon as they perceived the fire and that variation in the time elapsed until evacuation begun for occupants were wider as the size of building was bigger and that accommodations such as hotel had wider variation in the time elapsed regardless of the size of buildings.

A Occupant Load Density and Computer Modelling of Evacuation time in Office Buildings (사무소 건물의 거주밀도 분포와 피난시간 예측)

  • Kim, Un-Hyeong;Rui, Hu;Kim, Hong
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.35-42
    • /
    • 1999
  • A occupant load density of contemporary office buildings were surveyed by a building w walk through procedure in Korea. The survey results of ten office buildings are range from 1 2 2 2 213.14 m !person 041.4 ft !person) to 22.69 m /person (244.34 ft !person) with 95% confidence l level and the mean occupant load density is 17.92 m2/person 092.87 ft2/야rson). The impacts of occupant load on evacuation flow time was analyzed by applying time-based egress m model, SIMULEX with various occupant load densities from previous studies. I In order to demonstrate the validation of egress modeling method, fire evacuation exercise a and computer simulation were used to simulate the actual evacuation plan for a high-rise office building. An analysis and comparison of the results of these approaches was made to i illustrate the influence of model limitations on the result of prediction The result of the study shows that the introduction of occupant load concept in building c code of Korea is essential to achieving resonable building life safety design in future.

  • PDF

Smoke Mass Concentration의 측정에 의한 난연제의 난연 특성 평가

  • 송영호;정국삼
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.180-183
    • /
    • 2003
  • 최근 화재 발생시 화재의 열적 영향에 의한 인명 피해보다 연기 발생에 따른 피난로의 미확보, 독성 가스의 발생에 따른 질식사고에 의한 인명 피해가 급증하고 있다. 건물 내 화재시 발생되는 다량의 연기 및 독성 가스는 건물 내의 거주자의 피난을 방해하여 인명 피해의 중요 원인이 된다.(중략)

  • PDF

A study on an interval of tunnel cross passage considering inclination and internal airflow (터널 내부 기류 변화에 따른 피난연락갱 간격 설정에 관한 연구)

  • Rie, Dong-Ho;Kim, Ha-Young;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.1
    • /
    • pp.43-49
    • /
    • 2010
  • The escape connecting gallery in a tunnel on a road is one of emergency equipment to ensure safety for passer in the tunnel against the tunnel fire. Government stipulate over 500m tunnel has the cross passage at intervals of less then 250 m. However, this lump estimated interval is generated the concerns of exaggeration and under construction because peculiarity of the tunnel ex. The velocity of the tunnel airflow, an incline, degree of a fire, and innering area are not considered. The study indicate the way to estimate of the cross passage considered an incline and the velocity of the tunnel airflow for efficient application of cross passage on the tunnel design. As a result, in 0.0 m/s and 1.0 m/s of the velocity of the tunnel airflow case, the movement of smoke is influenced by the incline however, in 20 m/s case, it isn't influenced by incline much. According to the velocity of tunnel airflow and the incline, optimum interval of cross passage is not corresponded. Therefore established lump estimate that has 250 m intervals would be changed to estimate of optimum interval of cross passage that considered about the properties of tunnel, the velocity of the tunnel airflow, incline, degree of a fire and innering area of the tunnel.

Simulation analysis for evacuation safety countermeasure in underground facilities (지하공간시설에서의 피난안전대책을 위한 시뮬레이션 해석)

  • Kim, Bong-Chan;Kim, Se-Jong;Kim, Gyeong-Gu;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.100-105
    • /
    • 2011
  • 본 연구에서는 재실자의 밀도가 높은 지하상가는 공간의 특성상 화재가 발생할 경우 다량의 유독가스의 발생 및 연기의 이동경로와 인간의 피난경로 일치로 인하여 피난안전에 큰 위험성이 있다고 사료된다. 이에 지하철 역사와 연결되어 있는 지하상가를 선정 후, 일본 피난안전성평가수법과 FDS(Fire Dynamic Simulator) 및 SIMULEX를 이용하여 비교 분석을 하였으며, 그 결과, 화재발생 후 6분이 경과 시 위험한 것으로 판단되었다. 그에 대한 대책으로 자연 배연구를 설치하여 시뮬레이션 수행을 한 결과 가시도확보 및 각 출구에서의 온도가 하강하는 것을 확인할 수 있었다.

  • PDF

초고층건축물 피난안전성 평가를 위한 시뮬레이션 툴 개발

  • Kim, Jae-Hong;Jeong, Gi-Taek;Choe, Jin-Won;Choe, Jun-Ho;Hong, Won-Hwa
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.223-224
    • /
    • 2013
  • 최근 세계적으로 다양한 요소로 인하여 초고층건축물이 급속도로 건설되고 있다. 건축물이 초고층화 될수록 비상 시 탈출구까지의 길이 및 피난완료시간이 점점 더 길어지게 된다. 이에 국내 외에서 많은 연구가 진행되고 있으며, 특히 피난시뮬레이션 개발에 관련된 연구가 활발하게 진행되고 있다. 따라서 본 논문에서는 초고층건축물의 특성과 재실자들의 속성을 고려한 피난 시뮬레이션 툴이 개발될 수 있도록 프로그램의 연구방향 및 기초적인 자료를 제시하고자 한다.

  • PDF

A Study on the Walking Speed of crowd for safety evacuation of the elderly (고령자의 피난안전을 위한 군집보행에 관한 연구)

  • Hong, Hae-Ri;Seo, Dong-Goo;Kim, Dong-Eun;Hwang, Hyun-Bae;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.90-93
    • /
    • 2010
  • 본 연구는 국내의 고령화 추세와 고령자시설 현황을 고찰하고 일반인과 고령자의 군집형성시 보행속도를 측정하여 고령자를 고려한 피난안전설계의 기초자료로 제시하기 위한 연구이다. 군집보행속도 측정결과 고령자가 전방에 배치되었을 때 평균 0.81m/s로 가장 감소하였으며, 고령자 비율이 증가할수록 전체 보행속도는 감소하였다. 향후 피난안전설계를 위하여 고령자의 피난행동특성을 고려한 다양한 연구를 통한 DATA 확보가 필요할 것으로 판단된다.

  • PDF

An Analysis of algorithm fire & evacuation simulation developed by TFD and all countries of the world of simulation. (동경소방청의 화재피난시뮬레이션과 각국의 시뮬레이션 특성 및 알고리즘 분석)

  • Kim, Dong-Eun;Lee, Hyun-Jin;Seo, Dong-Goo;Yi, Jae-Won;Kazunori, Harada;Hwang, Eun-Kyoung;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.3-8
    • /
    • 2009
  • 2009년 국내에서 실행되는 성능위주설계인(PBD)을 비롯하여 화재안정성평가를 시뮬레이션을 중심으로 사용하고 있는 추세이다. 그러나 현재 국내에서는 자체 시뮬레이션 프로그램의 이용빈도 보다 타국의 프로그램의 이용 빈도가 높은 추세이다. 현재 많이 이용되고 있는 영국의 SIMULEX와 EXODUS가 대표적인 프로그램이 되겠다. 일본의 동경소방청에서 개발된 화재피난 시뮬레이션(FEA)에서는 연기와 화재성상을 고려하여 피난과 연동하여 피난을 실시하고 있다. 따라서 본 논문에서는 FEA가 국내에 적용방안에 합당한지 파악하고자 SIMULEX와 EXODUS 비교를 실시하여 FEA의 개선점을 도출하였다.

  • PDF

A Study on Type Classification and Evacuation Safety in Aged Shopping Building of Traditional Market for Specific Management Type (특정관리대상 재래시장 노후 상가 건축물 유형분류 및 피난안전실태에 관한 연구)

  • Lee, Young-Do;Na, Wook-Jung;Choi, Jun-Ho;Hong, Won-Hwa
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.52-56
    • /
    • 2011
  • 국내 재래시장 상가건축물은 타 상업지역 보다 노후화된 상업건축물이 상대적으로 많으며 밀집도 또한 높다고 할 수 있어 화재발생 시 화재확산 속도가 빠르고 화재진압이 어려워 인명 및 재산 피해의 가능성이 크다고 할 수 있다. 이에 따라 정부에서는 재래시장을 특정관리대상으로 지정하여 정기적으로 점검을 하고 있으나 소방시설에 비해 상대적으로 피난계획 및 피난설비에 대해서는 적절한 성능평가 및 점검이 이루어지고 있지 않고 있다. 이에 따라 본 연구에서는 대구시 소재의 특정관리대상으로 지정된 재래시장 상가건축물을 조사하여 재래시장의 평면유형분류를 하였고, 각 유형이 가지는 특성을 분석하였으며 대상건축물 피난설비의 실태조사를 통해 경년변화에 따른 설비의 노후화 특성을 분석하였다.

  • PDF

실내가연물의 유독가스 방출특성에 관한 연구

  • Kim, Hong;Oh, Kyu-Hyung;Lee, Young-Sub;Kim, Dong-Hyun;Ham, Sang-Geun
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.06a
    • /
    • pp.186-189
    • /
    • 2000
  • 국내의 건축물의 화재안전성 평가는 화재안전성을 고려한 공간구성, 연기의 유동, 거주자의 피난계획 및 피난성능평가, 건축물 내부에 설치된 방화설비계통의 화재안전성능평가 등을 연구하여 왔다. 그런데 이들 연구의 대부분은 건축물의 공간적 특성분석과 주거여건 등을 고려한 기초자료의 파악 및 분석 등을 국내의 여건과는 상이한 국외의 자료를 근거로 하거나 2차원적인 해석 및 평가에 그치고 있는 경향이 있다. (중략)

  • PDF