• Title/Summary/Keyword: 플라스틱팬

Search Result 21, Processing Time 0.029 seconds

Design of Fan Balancing System for Detecting Unbalance of Automobile Cooling Fan (자동차용 냉각팬의 불량검출을 위한 팬 밸런서 시스템 개발)

  • Youk, Yui-Su;Kim, Sung-Ho
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2008.04a
    • /
    • pp.273-275
    • /
    • 2008
  • Generally, automobile cooling fan is used to lower the temperature of radiator. The cooling fans are manufactured by plastic injection molding process. The center of gravity of cooling fan is often deviated from the center because of the use of deteriorated materials. As the unbalance of the cooing fan can generate noise, it is required to test the performance of the cooling fans. In this work, automatic fan balancer which can distinguish between the good and the bad, futhermore idenfify the position and magnitude of unbalance is develpoed.

  • PDF

Development of Fan Balancer System for Detecting Unbalance of Automobile Cooling Fan (자동차용 냉각팬의 불량검출을 위한 팬 밸런서 시스템 개발)

  • Kim, Sung-Ho;Youk, Yui-Su
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.1
    • /
    • pp.83-89
    • /
    • 2009
  • Generally, automobile cooling fan is used to lower the temperature of radiator. The cooling fans are manufactured by plastic injection molding process. The center of gravity of cooling fan is often deviated from the center due to the use of deteriorated materials. As the unbalanced of the cooing fan can generate noise, it is required to measure the degree of deviation of center of gravity in the cooling fan. In this work, automatic fan balancer which can effectively detect the magnitude and position of the unbalanced cooling fan is proposed and several experiments are carried out to verify the feasibility of the proposed algorithm.

Development of Asymmetric Plastic Fan Product (비대칭형 플라스틱 팬 제품 개발)

  • Yon, Kyu-Hyun;Kim, Hyung-Kook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.2
    • /
    • pp.53-59
    • /
    • 2009
  • The analysis of injection molding process by CAE is widely used in development of plastic products. That comes from the fact that CAE analysis can reduce trial and error based on optimized design. On this study, by use of MOLDFLOW, the causes of product defects were found and solved by trade-off study. CAE analysis includes Flow-Cool-Warpage Analyses and finally a new mold-die design with better product quality was suggested. On injection molding of round-shaped plastic fan, new mold-die system with 4-tunnel gates located on the edge of a fan disc shows better quality rather than pin-point gate located on the center of a disc. That was effective in terms of flow mark removal and flatness improvement of the product.

  • PDF

An Examination on Cooling Effects According to Water Spray, Top and Side Windows, and Operation of Fan of Single Span Plastic Greenhouses (Part 1) (단동 플라스틱 하우스의 관수, 천.측창 개폐 및 환기팬 조작에 따른 냉각효과 검토 (제1편))

  • 최동호;허종철;임종환;서효덕
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.51-54
    • /
    • 1999
  • 1. 하우스 개폐장치 조작 불능시를 가정하여 천ㆍ측창을 인위적으로 폐쇄한 경우, 하우스내 온도는 외기온 보다 16$^{\circ}C$ 높은, 즉 사실상 작물을 생육할 수 없는 고온상태를 나타내었다. 이러한 결과는 하우스 상태 및 외기조건 등에 따라 다소 상이할 것으로 예상된다. 2. 천ㆍ측창을 개방한 상태에서 환기팬을 가동한 경우, 환기팬 가동에 따른 추가적인 실온 저하 효과는 계측되지 않았다. 3. 본 연구에서는 비교적 노즐 입경이 큰 스프링클러를 이용하여 관수시의 냉각효과를 검토하였다. 이 경우, 하우스내 온도는 스프링클러 작동과 동시에 비교적 짧은 시간내에 급격한 온도강하가 이루어졌다. 이 후 지속적인 온도강하는 둔화되어 비교적 안정된 온도를 유지함으로서, 하우스의 실온저하에 크게 기여하고 있음을 확인할 수 있었다.

  • PDF

A study on CIM construction for the plastic fan design manufacturing (플라스택 팬 설계, 제조의 CIM 구축을 위한 연구)

  • Choi, Yang-Ho;Lee, Yong-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.9
    • /
    • pp.1470-1479
    • /
    • 1997
  • In this study, the plastic fan with high efficiency and low noise was designed and the capacity of the wind and the wind pressure were analysed and verified by CAE. After designing the metallic mold using the metallic mold design data, and the the metallic mold design was reformed by analysing the process of the material stream and injection filling by CAE. Also the metallic mold cutting data were formed using the metallic mold design data. These cutting data was used to produce the fan electrode by a machining center and then this electrode were used to manufacture the metallic mold by cutting the fan cavity by an electrical spark machine. The purpose of this study is to find out the sub-optimal condition on the productivity and improvement in quality of the plastic fan by integrating a series of this process with a computer.

Sawdust Cultivation of Lentinula edodes Using a Detachable Plastic Bottle (분리형 용기를 이용한 표고버섯 톱밥재배 연구)

  • Jeong, Yeun Sug;Jang, Yeongseon;Ryoo, Rhim;Ka, Kang-Hyeon
    • The Korean Journal of Mycology
    • /
    • v.47 no.4
    • /
    • pp.385-392
    • /
    • 2019
  • Currently, plastic bags are being used for sawdust cultivation of shiitake mushroom. However, due to serious environmental problems caused by the use of plastic bags, we studied the efficacy of bottle cultivation method to replace the sawdust bag method. Small detachable plastic bottles (400 g capacity) filled with Quercus spp. sawdust and wheat bran (4:1 w/w) media were incubated for 80 and 120 days. The weight loss (%) of the media was higher for the NIFoS 2464 strain at an approximate light intensity of 300 Lux than light intensity of 500 Lux; the light intensity was associated with the loss of sawdust medium-weight during the cultivation period. The highest yield was observed when the strain was cultivated for 80 days under dark conditions, 40 days under 500 Lux light, and air circulation fan speed of 30 rpm. When incubated for 120 days, mushroom yield in the bottle media was higher at 40 days of light exposure than 20 days of light exposure. In the bottle media incubated for 80 days under dark conditions, the mushrooms fruited due to repetitive water spraying on the top of the media and light stimulation during the fruiting period. The media could be separated from the bottles because the media shrank after the first harvest. These separated plastic bottles could be re-used for mushroom cultivation, thereby reducing the amount of plastic waste.

Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses (토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.215-224
    • /
    • 2009
  • A survey on the actual state of heating, cooling, ventilation, and air-flow and experimental measurement of temperature and humidity distribution in tomato greenhouse were performed to provide fundamental data required in the development of air-flow control technology. In single-span plastic houses, which account for most of 136 tomato greenhouses surveyed, roof windows, ventilation and air-flow fans were installed in a low rate, and installation specs of those facilities showed a very large deviation. There were no farms installed greenhouse cooling facilities. In the hot air heating system, which account for most of heating type, installation specs of hot air duct showed also a large deviation. The exhaust air temperature and wind speed in hot air duct also were measured to have a big difference depending on the distance from the heater. We are using the maximum difference as indicator to determine whether temperature distribution is uniform. However if the temperature slope is not identical in greenhouse, it can't represent the uniformity. We analyzed relation between the maximum difference and the uniformity of temperature and humidity distribution. The uniformity was calculated using the mean and standard deviation of data from 12 measuring points. They showed high correlation but were represented differently by linear in the daytime and quadratic in the nighttime. It could see that the uniformity of temperature and humidity distribution was much different according to greenhouse type and heating method. The installation guidelines for ventilation and air-flow fan, the spread of greenhouse cooling technology for year-round stable production, and improvement of air duct and heating system, etc. are needed.

Characteristics of Cooling Effect Depending on Operation of Forced Ventilation Systems in a Single-span Plastic Greenhouse (강제환기장치 사용에 따른 단동 플라스틱 온실 기온 강하 특성)

  • Kim, Seong-Heon;Kim, Hyung-Kweon;Kwon, Jin-Kyung;Lee, Si-Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.143-151
    • /
    • 2022
  • This study was carried out to investigate quantitative characteristics of the cooling effect in a single-span arch greenhouse with roll-up side vents depending on operation of circulation and exhaust fans during ventilation, in order to suggest a practical strategy regarding installation or operation of forced ventilation systems. The examination was conducted under 3 different ventilation conditions (side vents only, side vents + circulation fans, and side vents + circulation fans + exhaust fans). In each condition, variations of internal and external air temperatures and exogenous environmental factors were recorded during ventilation, and the cooling effects were investigated by comparing the normalized temperature difference (NTD) of each ventilation condition. In the morning time (11:00-12:00), a temporary peak in the temperature difference was observed at the beginning of ventilation regardless of ventilation methods. The time taken to the maximum NTD was decreased from 340 s to 110s, and the NTD was dropped from 1.158 to 1.037 as the more forced ventilation systems were operated. The more operations caused the passing time over specific NTD values reduced by 60% as the time was reduced from 1,030 s to 550 s at NTD = 0.8, 1,610 s to 915 s at NTD = 0.6, and 2,315 s to 1,360 s at NTD = 0.4. The temporary peak in NTD was not observed in the afternoon time (14:00-15:00) but it was dropped as quickly as the ventilation started. Also the more operations resulted in the passing time over specific NTD values reduced by 70% as the time was reduced from 560 s to 345 s at NTD = 0.8, from 825 s to 540 s at NTD = 0.6, and from 1,145 s to 810 s at NTD = 0.4. Conclusively, the intervention of the forced ventilation system is recommended in the morning time or in high thermal conditions to achieve more effective and economical ventilation.

Effects of Modified Installation Methods of Roof Ventilation Devices in the Single-span Plastic Greenhouses on Yield and Fruit Quality of Oriental Melon (단동 비닐하우스의 지붕 환기장치 설치방법 개선이 참외생육 및 과실수량에 미치는 영향)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Choi, Gyeong Lee;Lee, Seong-Chan;Lee, Jae-Han;Park, Kyoungs Sub;Lee, Jung-Sup;Bekhzod, Khoshimkhujaev
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.334-342
    • /
    • 2016
  • In order to evaluate the modified installation methods of roof ventilation devices, derived from the previous experiment ('investigation into the optimum capacity of roof ventilation devices and their deployment'), the conventional and modified (improved) roof ventilation systems were installed in the single-span plastic greenhouse for growing oriental melons. The roof vents ($60{\varphi}$) and roof fans (maximum air capacity of $38m^3/min$) were installed in the spacing of 15m (FT, modified 'side vent+roof fan' ventilation) and 6m (TT, modified 'side vent+roof vent' ventilation) respectively on the roof of greenhouses for the modified roof ventilation treatments, and 20m (FC, conventional 'side vent+roof fan' ventilation) and 8m (TC, conventional 'side vent+roof vent' ventilation) for the conventional ones. The stem diameter, leaf blade lengh, petiole length, and leaf width were lower in the FT and TT treatments than those in the conventional treatments, FC and TC. Although the fruit weight and total yields were slightly lower in the FT and TT treatments, the marketable fruit ratio (%) were higher, as a result of increased fruiting ratio (%) in these treatments, than those of FC and TC. The marketable yields (kg/10a) in the FT and TT treatments were 8,391 kg/10a and 7,283 kg/10a, which were respectively 661 kg/10a and 487 kg/10a higher than those in the treatments of FC and TC. The modified installation methods of roof fan resulted in production of more female flowers and lower fruit drop ratio (%) compared to conventional meathods. In the treatment of the conventional ventilation with roof vent, the fruit weight, fruit length & width, and flesh thickness were higher than in other treatments, but there were no significant differences in the fruit width and flesh thickness among the treatments.