Dry Connections for Precast Shear Wall Systems (프리캐스트 전단벽 시스템의 건식접합부에 관한 연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.530-533
    • /
    • 2006
  • This thesis investigates the behavior of precast wall systems with a new vertical connection which are proportioned by the displacement based design. The proposed precast wall systems are supposed to provide additional spaces and seismic strengthening in remodeling existing residential buildings. For a fast remodeling constructions using PC walls require an efficient, economic fabrication method. A C-type vertical connections for PC wall systems is proposed for transfer of bending moment between walls in the vertical direction while a shear key in the center of wall is prepared to transfer shear forces by bearing. The proposed vertical connection allows us easy fabrication because of different direction of slots at the edges of wall. The dimension of C-type connection components are determined by engineering models and a series of test.

  • PDF

Precast Shear Wall Systems with C Type Connections (C형 접합부를 이용한 프리캐스트 전단벽 시스템에 관한 연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.217-224
    • /
    • 2006
  • This thesis investigates the behavior of precast wall systems with a new vertical connection which are proportioned by the displacement based design. The proposed precast wall systems are supposed to provide additional spaces and seismic strengthening in remodeling existing residential buildings. For a fast remodeling constructions using PC wails require an efficient, economic fabrication method. A C-type vertical connections for PC wall systems is proposed for transfer of bending moment between walls in the vertical direction while a shear key in the center of wall is prepared to transfer shear forces by bearing. The proposed vertical connection allows us easy fabrication because of different direction of slots at the edges of wall. The dimension of C-type connection components are determined by engineering models and a series of test.

  • PDF

Cyclic Behavior of Slender Reinforced Concrete Coupling Beams with Bundled Diagonal Reinforcement (묶음 대각철근을 갖는 세장한 철근콘크리트 연결보의 이력거동)

  • Han, Sang-Whan;Yoo, Kyoung-Hwan;Lee, Ki-Hak;Shin, Myoung-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.6
    • /
    • pp.661-668
    • /
    • 2015
  • Coupled shear walls are effective lateral force resisting system in which coupling beams link individual walls. For improving the energy dissipation capacity of coupling beams, diagonal reinforcement details were developed. However, it is difficult to construct diagonal reinforced coupling beams due to the congestion of reinforcement in the beam. For resolving the problem, this study developed precast coupling beams with bundled diagonal reinforcement. To reduce the reinforcement congestion, bundled diagonal reinforcement were placed in the coupling beam. To evaluate the cyclic performance of coupling beams with bundled diagonal reinforcement, experimental test were conducted. For this purpose, two slender specimens with an aspect ratio of 3.5 were made and tested. It was observed that the cyclic performance of the coupling beam with bundled diagonal reinforcement was similar with that of the coupling beam with normal diagonal reinforcement placed according to design code to ACI 318-11.

Seismic Performance of Precast Infill Walls with Strain-Hardening Cementitious Composites (변형경화형 시멘트 복합체를 사용한 프리캐스트 끼움벽의 내진성능)

  • Kim, Sun-Woo;Yun, Hyun-Do;Jang, Gwang-Soo;Yun, Yeo-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.327-335
    • /
    • 2009
  • In the seismic region, non-ductile structures often form soft story and exhibit brittle collapse. However, structure demolition and new structure construction strategies have serious problems, as construction waste, environmental pollution and popular complain. And these methods can be uneconomical. Therefore, to satisfy seismic performance, so many seismic retrofit methods have been investigated. There are some retrofit methods as infill walls, steel brace, continuous walls, buttress, wing walls, jacketing of column or beam. Among them, the infilled frames exhibit complex behavior as follows: flexible frames experiment large deflection and rotations at the joints, and infilled shear walls fail mainly in shear at relatively small displacements. Therefore, the combined action of the composite system differs significantly from that of the frame or wall alone. Purpose of research is evaluation on the seismic performance of infill walls, and improvement concept of this paper is use of SHCCs (strain-hardening cementitious composites) to absorb damage energy effectively. The experimental investigation consisted of cyclic loading tests on 1/3-scale models of infill walls. The experimental results, as expected, show that the multiple crack pattern, strength, and energy dissipation capacity are superior for SHCC infill wall due to bridging of fibers and stress redistribution in cement matrix.

Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel (L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석)

  • Yu, Sung-Yong;Ju, Ho-Seong;Ha, Soo-Kyoung
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

Effect of Reinforcement details on the Seismic Performance of Precast Strain-Hardening Cementitious Composite(SHCC) Infill Walls (보강상세에 따른 프리캐스트 변형경화형 시멘트 복합체 끼움벽의 내진성능)

  • Kim, Sun-Woo;Yun, Hyun-Do;Song, Seon-Hwa;Yun, Yeo-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.209-216
    • /
    • 2009
  • Flexible frames on their own offer little resistance to lateral forces, resulting often in large deflections and rotations at the joints. On the other hand, walls subjected to lateral loads fail mainly in shear at relatively small displacements. Therefore, when the nonductile frames and wall act together, the combined action of the composite system differs significantly from that of the frame or wall alone. The objective of the study is to evaluate seismic response of infill walls with notched midsection. Reinforcement detail of wall was main variable in the experiment. Also SHCC was used in order to prevent damage concentration into notched midsection of walls. Test results, SHCC infill walls show the multiple crack patterns as expected. However, PIW-ND specimen exhibits less story drift, stiffness and energy dissipation capacity than those of PIW-NC specimen.

A Study of New Approach on Elasto-Plastic Analysis of shell Structures (쉘구조물의 탄소성해석에 관한 새로운 해석법의 연구)

  • Kwun Taek Jin;Park Kang Geun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.20 no.3
    • /
    • pp.5-14
    • /
    • 1987
  • 연속체의 해석에 있어서, 특별한 경우를 제외하고는, 구조물의 개략적인 거동을 파악해야 될 경우가 종종 있다. 이러한 요구에 부응하기 위해서 강체요소법(Rigid Element Method)이라 불리우는 새로운 해석법이 개발되었다. 강체요소법은 원래 평정연구실에서 벽식프리캐스트 철근콘크리트 구조물의 탄소성해석을 하기 위해서 개발된 해석법에 착안하여, 내수벽과 같은 연속체에 적용함으로서 시작된 수치해석법이다. 그 후 저자들은 도통쉘, 구형쉘 혹은 이들이 조합된 쉘구조물에 적용할 수 있도록 개발 확장하였다. 강체요소법의 기본개념은 연속체의 분해된 각 요소를 강체(rigid body)라고 가정하고, 각 요소들은 요소의 강성으로 치환된 가상스프링으로 서로 연결되어 있다고 가정하여, 이 가상스프링의 거동을 평가함으로서 전체구조물의 거동을 파악하는 해석법이다. 이때 요소의 주변에 취해진 스프링은 해석을 단순화하기 위해서 축력, 면내전단력 및 면외전단력만을 전달한다고 가정하고, 요소의 강체변위(자유도)는 요소내의 임의의 한 점에서 취하며, 이 점에서의 강체변위(rigid displacements)는 요소의 주변에 취해진 스프링을 통하여 다른 요소로 전달된다. 상기와 같은 강체요소법의 개념을 연속체의 탄성 및 탄소성해석에 적용하면, 해석적 개념이 단순할 뿐만 아니라 구조물 전체의 자유도수를 대폭 줄여 컴퓨터 계산시간을 절약할 수 있는 잇점이 있고, 거시적인 모델(macroscopic modeling)과 미시적인 모델 (microscopic modeling)의 중간적인 성격을 가지기 때문에 구조물의 파괴상황에 대해서도 그 개략을 파악할 수 있다. 본 논문에서는 강체요소법을 보다 일반화된 해석법으로 개발, 확장하기 위해서 종전에 단층스프링시스템(single-layer spring system)으로 해석이 어려웠던 문제점들을 보완한 복층프링시스템(double-layer spring system)을 사용함으로서 휨, 비틀림의 효과를 파악할 수 있는 이론적 개념을 적용한 새로운 구요소, 원통요소 및 평면요소를 개발하고, 이러한 강체요소들의 적합매트릭스의 유도 및 해석저긴 방법을 정식화하였다. 또 휨, 비틀림 및 전단력의 효과를 고려한 사각형원통요소 및 능형원 통요소를 이용하여 원통쉘의 탄성 및 탄소성해석할 수 있는 프로그램을 개발하고, 이 프로그램으로 캔틸레버로된 연속형철근콘크리트 원통쉘의 탄성 및 탄소성해석에 적용하여 구조물의 거동에 관한 수치해석의 결과, 즉 내력의 분포, 균열의 진전, 파괴의 상황 및 변형의 상태 등을 파악해 보았다.

  • PDF