• 제목/요약/키워드: 프레팅 접촉

검색결과 39건 처리시간 0.024초

회전굽힘 피로 하에서의 철도 차축재료 프레팅 피로거동 평가 (The Evaluation of Fretting Fatigue Behavior on Rotary Bending Fatigue for Railway Axle Material)

  • 최성종;권종완
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.74-82
    • /
    • 2010
  • Fretting damage can be observed in automobile and railway vehicle, fossil and nuclear power plant, aircraft etc. In the present study, railway axle material RSA1 used for evaluation of fretting fatigue life. Plain and fretting fatigue tests were carried out using rotary bending fatigue tester with proving ring and bridge type contact pad. Through these test, the following results are obtained: 1) it is found that the fretting fatigue limit of standard specimen decreased about 37% compared to the plain fatigue limit. 2) The early crack of Shinkansen type specimens initiated in contact area and final fractured below samp=214 MPa. 3) The early crack of all TGV type specimens initiated in rounded area and fractured. 4) Tire tracks and rubbed scars were observed in the oblique crack region and fatigue crack growth region of fracture surface. 5) The wear debris is observed on the contact surface, and oblique cracks at an earlier stage are initiated in contact area. These results can be used as useful data in a structural integrity evaluation of railway axle.

자동차용 전장 커넥트 프레팅 마모 손상 평가 (Evaluation of Fretting Wear Damage of Electronic Connectors for the Automotive)

  • 장승규;김덕현;김진상;최성종;조현덕
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.33-41
    • /
    • 2014
  • Fretting is a kind of surface degradation mechanism observed in mechanical components and structures. When two pieces of materials, pressed together by an external static load, are subjected to a transverse cyclic loading or various vibrations, so that one contacting face is relatively displaced cyclically parallel to the other face, wear of the mating surfaces occurs. These fretting damages may be observed in electrical connectors for automotive components, where there are special environments and various vibration conditions. This study aims to evaluate the usefulness of fretting test equipment that was developed for reliability test of electrical connector. Fretting tests were carried out using tin coated connectors and friction force, contact resistance, contact area and roughness of contact region were investigated. The following results that will be helpful to understand the fretting wear mechanism, increase process the contact resistance and contact area were obtained. (1) In the same frequency and slip amplitude, the friction force, roughness and contact area increased rapidly until about $10^3$ cycles, after which it was slightly changed. (2) In the various frequency and slip amplitude, the contact area increased with slip amplitude and cyclic numbers, but it did not depend on cyclic frequency. (3) The surface roughness of contact region did not depend on the cyclic frequency. From these results, the applicability of the fretting wear test equipment and reliability of connector were discussed.

A12024-T4의 프레팅 피로균열거동에 관한 실험적 연구 (An experimental study on the fretting fatigue crack behaviour of A12024-T4)

  • 이봉훈;이순복
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.511-518
    • /
    • 1997
  • The technique of fretting fatigue test was developed and fretting fatigue tests of A12024-T4 were conducted under several conditions. The newly developed calibration methods for measuring surface contact tractions showed good linearity and repeatability. The plate type specimen to which tow bridge type pads were attached and vision system was used to observe the crack behaviour. The oblieque cracks appeared in the early stage of crack growth and they became mode I cracks as they grow about 1 mm. The mode I transition points were found to be longer when surface tractions are higher or bulk stress is lower. Before the crack becomes mode I crack, 'well point' where crack grow about rate is minimum, was detected under every experimental condition. The crack behaviour was found to be affected by surface tractions, contact area, bulk stress. It was also found that partial slip and stick condition is most detrimental and the crack starts from the boundary of stick and slip. For gross slip crack started at the outside edge of pad. After crack mode transition, fretting fatigue cracks showed almost same behaviour of plain mode I fatigue cracks. Equivalent stress intensity factor was used to analyze the behaviour of fretting fatigue cracks and it was found that stress intensity factors can be applied to fretting fatigue cracks.

공기중에서 인코넬-지르칼로이 접촉의 프레팅 마멸특성 (Fretting Wear Characteristics of Inconel-Zircaloy Contact in Air)

  • 노규철;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.310-316
    • /
    • 1999
  • The fretting wear characteristics of the contact between Zircaloy-4 tube and Inconel 600 tube have investigated. Zircaloy-4 is used for fuel rod in nuclear reactor and Inconel 600 is used for tube In steam generator of nuclear power plant. A fretting wear tester was designed to be suitable for this fretting test. In this study, the number of cycles, slip amplitude and normal load were selected as main factors of fretting wear. This study shows that the wear scar length of Zircaloy-4 and Inconel 600 increases as number of cycles, normal load and slip amplitude increase and the wear scar length of Zircaloy-4 is more longer than that of Inconel 600 due to the surface hardness.

  • PDF

지르칼로이-인코넬 접촉에서의 프레팅 손상 평가 (Fretting Oamage Evaluation of Zircaloy-Inconel Contact)

  • 김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.263-268
    • /
    • 2000
  • The fretting damage of the contact between Zircaloy-4 and Inconel 600 have Investigated. A fretting wear tester was designed to be suitable for this fretting test. In this study, the number of cycles, slip amplitude and normal load were selected as main factors of fretting wear. As the result of this research the wear volume increased with the increase of loads, slip amplitudes and the number of cycles and was more affected by slip amplitudes rather than by load. According to SEM, stick, partial slip, gross slip were observed on the surface of both specimens and wavy worn surfaces as the typical fretting damage were also Investigated due to accumulation of plastic flow.

  • PDF

측정된 마모 깊이와 시간에 의해 역으로 계산된 마모상수를 이용한 마모 깊이 예측 (A Method to Predict Wear Depth Using Inversely Calculated Wear Constants from Known Wear Depth and Time)

  • 이용선;김태순;박치용;부명환;이창섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.178-188
    • /
    • 2003
  • The wear of steam generator tubes is due to the vibration occurred between tubes and tube supporters. To predict the future wear depth, the wear constants of the impact and the sliding model is used. The wear constants, 3C/2 and K/3H, are found inversely from known wear depth and time. Using these constants, the future wear depths are found from two bodies that deform the elliptical shape. The results are compared with the measured wear depth of steam generator tubes in a nuclear power plant. The results show that the predicted wear depth envelopes the measured wear depth.

  • PDF

프레팅 손상을 받는 물체의 접촉부 정렬에 대한 고찰 (A Study on the Alignment of Contacting Bodies subjected to Fretting Failure)

  • 김형규;윤경호;강홍석;송기남
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제32회 추계학술대회 정기총회
    • /
    • pp.37-43
    • /
    • 2000
  • The effect of the alignment of the contacting bodies is concerned. Tilting of a body (indenter) is regarded as a mis-alignment. Recently developed method fur evaluating the contact normal traction is introduced and discussed, in which piecewise parabolic profile is considered as a generalized contact profile. Indentation by a wedge with rounded apex is solved as an example problem. In the case of partial slip regime, the variation of shear traction is examined during the closed path of shear force by using the efficient numerical technique. Concentration of the slip region is also investigated. By evaluating the energy dissipation from the contact surface, the effect of the mis-alignment-alignment on wear is discussed.

  • PDF

지지부 형상에 따른 튜브 프레팅 마멸기구의 연구 (A study on wear mechanism of tube fretting affected by support shapes)

  • 이영호;김형규;하재욱
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.73-79
    • /
    • 2002
  • 상온 공기분위기에서 두 가지 형태의 스프링에 대한 연료봉 피복관의 마멸실험을 수행하였으며 다음과 같은 결론을 얻었다. (1) 가장 큰 마멸부피는 스프링 형상이 오목할 경우 틈이 존재할 때 발생하였으며, 형상이 볼록한 경우에는 접촉하중이 존재할 때 마멸부피가 크게 나타났다. (2) 접촉형상이 오목한 형태로 연료봉을 감싸고 있는 경우, 마멸입자의 방출은 다소 어렵게 되며 이에 따라 마열거동은 표면에서 생성되는 마멸입자가 외부로 방출되는 용이성에 따라 최종적으로 마멸부피는 결정된다. (3) 볼록한 형상의 스프링의 경우, 충격마모에 대하여 저항성을 보였으나, 접촉하중이 존재할 경우 높은 마멸량을 보이고 있다. (4) 오목한 형태의 스프링 조건에서 축 방향의 마멸보다는 횡 방향의 마멸량이 더 낮게 나타났다. 이것의 주된 원인은 오목한 형태의 스프링이 충격하중에 있어 가이드역할을 할 가능성이 있는 것으로 나타났다. 또한, 양 방향 모두 마멸입자의 고착 흔적이 나타났으나 횡 방향의 경우 연삭에 의한 경향이 보다 뚜렷이 나타났다.

  • PDF

핵연료봉 프레팅마멸에서 마멸깊이와 접촉하중 감소사이의 관계 (The Relationship between a Wear Depth :and a Decrease of the Contacting Force in the Nuclear Fuel Fretting)

  • 이영호;김형규
    • Tribology and Lubricants
    • /
    • 제22권1호
    • /
    • pp.8-13
    • /
    • 2006
  • Sliding wear tests have been performed to evaluate the effect of normal load decrease on the wear depth of nuclear fuel rods in room temperature air. The objectives of this study are to quantitatively evaluate the supporting ability of spacer grid springs, to estimate the wear depth by using the contacting force decrease and to compare the wear behavior with increasing test cycles (up to $10^7$) at each spring condition. The result showed that the contacting load decrease depends on the spring shape and the applied slip amplitude. The estimated wear depth is smaller when compared with measured wear depth. Based on the test results, the wear mechanism, the role of wear debris layer and the spring shape effect were discussed.