• Title/Summary/Keyword: 풍속감소율

Search Result 53, Processing Time 0.028 seconds

A Case Study: Improvement of Wind Risk Prediction by Reclassifying the Detection Results (풍해 예측 결과 재분류를 통한 위험 감지확률의 개선 연구)

  • Kim, Soo-ock;Hwang, Kyu-Hong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.3
    • /
    • pp.149-155
    • /
    • 2021
  • Early warning systems for weather risk management in the agricultural sector have been developed to predict potential wind damage to crops. These systems take into account the daily maximum wind speed to determine the critical wind speed that causes fruit drops and provide the weather risk information to farmers. In an effort to increase the accuracy of wind risk predictions, an artificial neural network for binary classification was implemented. In the present study, the daily wind speed and other weather data, which were measured at weather stations at sites of interest in Jeollabuk-do and Jeollanam-do as well as Gyeongsangbuk- do and part of Gyeongsangnam- do provinces in 2019, were used for training the neural network. These weather stations include 210 synoptic and automated weather stations operated by the Korean Meteorological Administration (KMA). The wind speed data collected at the same locations between January 1 and December 12, 2020 were used to validate the neural network model. The data collected from December 13, 2020 to February 18, 2021 were used to evaluate the wind risk prediction performance before and after the use of the artificial neural network. The critical wind speed of damage risk was determined to be 11 m/s, which is the wind speed reported to cause fruit drops and damages. Furthermore, the maximum wind speeds were expressed using Weibull distribution probability density function for warning of wind damage. It was found that the accuracy of wind damage risk prediction was improved from 65.36% to 93.62% after re-classification using the artificial neural network. Nevertheless, the error rate also increased from 13.46% to 37.64%, as well. It is likely that the machine learning approach used in the present study would benefit case studies where no prediction by risk warning systems becomes a relatively serious issue.

Effects of Ventilation Condition and Ventilating Hole Sizes to Improve Quality Onion(Allium cepu. L) under Room Temperature (양파 간이저장시 통풍조건 및 통풍구 재료의 크기가 저장에 미치는 영향)

  • 이찬중;김희대;정은호;김우일;서전규
    • Food Science and Preservation
    • /
    • v.8 no.4
    • /
    • pp.356-361
    • /
    • 2001
  • This study was conducted to improve the storability of onion bulbs by assembly simple house storage and the reduce the rotteness caused by field open storage. Allium cepa cv. Changnyungdeago, late strain was used for the test at the storage condition of natural ventilation of levels 2, forced ventilation of levels 2, field open storage and 75mm, 100mm, and 125mm ventilating holes. Mean tamperature and relative humidity were not significantly different by ventilation conditions. Mean temperature was lower in forced ventilation than that of in natural ventilation and non-ventilation, and relative humidity was a little higher in ventilation treatment than those of the others. Weight loss of onion bulbs were 2.5%, 2.9%, 3%, 4.3% in field open storage, non ventilation, natural ventilation of levels 2 and forced ventilation of levels 2 respectively. Rotting rate in natural ventilation of levels 2 and farced ventilation of levels 2 were 27.7% and 25.4% respectively but 34.6% and 37.8% in non ventilation and field open storage. Therefore, the treatment of ventilation reduced the rotteness of storage onion bulbs. The smaller the size of a ventilating hole, the lower mean temperature was maintained. The relative humidity was some high in July, but didn’t showed significantly difference in August and September. With small size of a ventilating hole, the strong wind velocity was obtained, and wind velocity by position was weaker in the middle part than both ends. Rutting rates in 75㎜, 100㎜, and 125㎜ ventilating holes were 17.9%, 15.3% and 14.1% respectively.

  • PDF

A study on changes in water cycle characteristics of university campus catchment: focusing on potential evapotranspiration improvement in Mt. Gwanak catchment (대학 캠퍼스 유역의 물순환 특성 변화에 관한 연구: 관악산 유역 잠재증발산량 개선을 중심으로)

  • Kim, Hyeonju;Kim, Young-Oh
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.12
    • /
    • pp.1077-1089
    • /
    • 2022
  • With the construction of Seoul National University (SNU), the Mt. Gwanak watershed has undergone some urbanization. As with other campus catchments, data related to the water cycle is extremely limited. Therefore, this study began by collecting hydrological and meteorological data using Atmos-41, a complex meteorological observation instrument. The observation results of Atmos-41 were validated by analyzing the statistical characteristics and confidence intervals based on the monthly variability of data from the Korea Meteorological Administration. Results of the previous research were used to validate the simulated surface runoff and infiltration using the Storm Water Management Model (SWMM). The potential evapotranspiration (PET) simulated by the SWMM was rectified by comparing it to the Atmos-41 observation data. Multiple regression analysis was employed to adjust for the fluctuations in precipitation, relative humidity, and wind speed because the calculated SWMM PET tends to be underestimated during periods of low temperatures. R2 increased from 0.54 to 0.80 when compared to the Atmos-41 PET. The rate of change in the water cycle as a consequence of the SNU's construction resulted in a 15.7% increase in surface runoff, a 14.2% decrease in infiltration rate, and a 1.6% decrease in evaporation.

Properties on the Airborne Chlorides of Offshore Bridges on the Western/Southern Coast in South Korea (국내 서/남해안 해상교량의 월별, 높이별 비래염분량 특성)

  • Jung, Jahe;Min, Jiyoung;Lee, Binna;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.59-67
    • /
    • 2022
  • In this study, the monthly airborne chlorides flying into the offshore bridges were investigated depending on the sea level. The target structures were 9 bridges located on the western and southern coast of South Korea. The airborne chlorides were measured at different sea levels on each bridge every month during 1 year. The results showed that the strongest seasonal wind from the northwest in winter expecially have led increase of the airborne chlorides, and its effect was more significant in the western coast than the southern coast. It was also found that the airborne chlorides declined with the increase of sea level. Three types of curves were suggested for analyzing the decrease trend with the sea level, based on the airborne chlorides at the lowest measurement height of main tower. The trend was varied depending on the sea area, and even in the same sea area, the local topographic condition affected the airborne chlorides. It means that the location and local topography should be considered simultaneously for durability management in the framework of the chloride source, and then the influence of the chloride source should be classified, e.g. safe and dangerous. From these results, it is expected that it could be used as baseline data for the evaluation of the deterioration environment in the Detailed guidelines for safety and maintenance of facilities [Performance evaluation]_Bridge.

Analysis on Heat Loss of Single-span Greenhouse Using Small-scaled Wind Tunnel (소형풍동을 이용한 단동 비닐온실의 열손실 분석)

  • Kim, Young Hwa;Kim, Hyung kow;Lee, Tae suk;Oh, Sung sik;Ryou, Young sun
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2020
  • The objective of this study is to analyze the heat transfer loss of covering materials in a single-span plastic greenhouse under the steady-state wind environment. To achieve this objective, the following were conducted: (1) design of a small-scaled wind tunnel (SCWT) to analyze heat losses of the greenhouse and its performance; (2) determination of the overall heat transfer coefficient (OHTC) for the covering materials using a small-scaled greenhouse model. The SCWT consists of the blowing, dispersion, steady flow, reduction and testing areas. Each part of the SCWT was customized and designed to maintain air flow at steady state and to minimize the variances in the SCWT test. In this study, the OHTCs of the covering materials were calculated by separating each with the roof, side wall, front and back of the small-scaled greenhouse model. The results of this study show that the OHTC of the roof increases as wind speed increases but the zones in which the increase rate of the OHTC decreased, were distinguished by wind tunnel wing speed of 2 ms-1. For the side wall, the increase rate of the OHTC was particularly higher in the 0-1 ms-1 zone.

Application of Heat Balance Model Design of Ventilating and Cooling Greenhouse (온실의 환기 및 냉방 설계를 위한 열평형 모델의 작용)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.201-206
    • /
    • 2000
  • A certain system to overcome high temperature should be introduced for the stable year-round cultivation in greenhouses. There are efficient methods to overcome high temperature such as ventilation system with shading screen, fan and pad system with screen, and fog system with screen. This study was carried out to find a means to determine the capacity of such system. Heat balance equations for each system were established and verified by experimental results. The calculated ventilation rates from heat balance equations showed a good agreement with the measured ones. The evapotranspiration coefficient was the most important parameter affecting the ventilation requirement among input parameter affecting the ventilation requirement among input parameters except weather data. When the evaportanspiration coefficient increased 1%, the ventilation requirement decreased 1.3%. Therefore the data of evapotranspiration coefficient should be accumulated by various experiments, and then design standards and selection guidelines should be provided. The simulation results for same design conditions shown that air exchanges requirement and evaporating water of fan and pad system were 5.1∼7.7% and 6.8∼9.3% larger than those of fog system, respectively.

  • PDF

The Effect of indoor illuminance depends on direction of the side windows lighting (측창채광의 방향에 따른 실내조도의 영향)

  • Cho, Shee-Man;Kim, Won-Joong;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.253-260
    • /
    • 2004
  • 실내의 조명은 자연채광방식과 인공조명으로 나누어지는데 자연형 채광방식에서도 측창채광과 천창채광, 정 측창채광 그리고 반사 채광방식이 있다. 측창채광은 벽면에 대하여 일반적으로 연직인 창에 의한 채광을 말한다. 측창채광의 방향에 따라 실내조도는 영향을 많이 받는다. 따라서 본 연구는 측창채광의 동서남북의 방향에 따라 봄, 여름, 가을, 겨울의 계절에 따라 아침, 점심, 저녁시간대에 따라 변화되는 실내조도를 알아보았다. 실험방법은, 조명시뮬레이션 프로그램인 Lightscape V3.2를 사용하여 교실공간의 치수와 작업면의 높이를 가로 5.8[m], 세로 10.8[m], 높이 3[m], 작업면의 높이 0.75[m]로 정하였고, 각 시설물의 반사율[p]은 벽 80%, 창문 12%, 출입문 13%, 바닥 20%, 천장 85%로 지정하였으며 창문의 투과율은 88%로 설정하였다. 본 연구에서 측정하고자 하는 변수 값은 계절은 여름을 6월20일, 겨울은 1월20일 기준으로 하고 시간대는 09시, 13시, 18시로 하였으며 창측방위는 동, 서, 남, 북으로 정하였으며 계절과 시간은 가장 차이가 많이 나는 값을 선택하였다. 결론으로 창이 남쪽일 때 평균조도가 9,100[lx]로 가장 높았고, 시간별로는 점심에 19,590[lx]로 조도가 가장 높은 것을 알 수 있었고 조도 균제도는 창이 동쪽일 때 겨울에 가장 높았다. 창이 북쪽일 때는 여름이 겨울보다 평균조도가 약간 높았고, 시간별로는 아침에 조도가 약간 높은 것을 알 수 있었고 전체적으로 북쪽 창에서 실내조도가 현저하게 떨어지는 것을 알 수 있었다. 이와 같은 결과로 측창의 브라인드를 현재 사용하고 있는 수직 브라인드 대신에 수평 브라인드를 사용하여 주광의 범위를 넓게 조절하여 사용하게 하고, 점등제어를 현재 측창면과 수직으로 되어있는 배열을 수평으로 한다면 자연채광의 효과를 배가 할 수 있으리라고 사료된다. 미백 전, 미백후, 재광화 후 미세경도 변화 양상이 미백을 하지 않은 대조군과 차이를 보이지 않았으며 (p > 0.05) 미백 전과 미백 후의 미세경도의 차이 미백후와 재광화 후의 미세경도의 차이도 유의할 만한 차이가 없었다 (p > 0.05). 따라서 시중에 판매되고 있는 whitening strip과 미백 젤은 14일 동안의 통상적인 미백과정 동안 법랑질의 미세경도에 영향을 미치지 않는 것으로 사료된다.able pitch와 helical angle보다는 근본적으로 radial land가 screw-in effect의 예방에 더 큰 역할을 하는 것으로 추정될 수 있다 따라서 NiTi file의 사용 경험이 없는 초심자의 경우 근단부 폭경의 유지능력이 좋은 ProFile$^{(R)}$의 사용이 추천된다.)되었다.였으나 강남콩군 외에는 단백질의 소화 흡수율 및 효율은 크게 향상되지 않아 단백질의 소화 흡수율을 떨어뜨리는 요인에 관한 연구가 집중적 으로 이루어져야 하리라고 생각된다.면 바로 위 지점의 풍속을 측정하였다. 각 Seeding 물질에 대해 팬을 켜지 않았을 때, 즉 바람의 영향이 없을 때 측정한 표면유속을 바람의 세기가 변한 경우의 기준 표면유속으로 이용하였다. 본 연구의 결과 비중이 0.01 내외인 Ecofoam과 white polystyrene에 비해 비중이 0.92인 black polypropylene은 대부분이 물속에 잠겨 있어 흐름과 거의 일치하여 움직임을 알 수 있었다. 또한 흐름의 평균유속이 0.165 m/s의 저유속에서 바람이 tracers에 미치는 영향이 평균유속 0.558m/s인 경우보다 커서, 바람의 세기의 증가에 따라 표면유속 측정값이 급속히 감소되었다. 흐름의 평균유속이 큰 경우에는 바람이 tracer에 마치는 영향이 현격히 줄어듬을 보이고 있다. 결론적으로 유속이 증가함에 따라 바람의 영향은 감소하나, 바

  • PDF

Impact Assessment on the Change of Thermal Environment, According to the Hydraulic Characteristic Urban Regeneration Stream: Cheonggyecheon Case Study (도심재생하천 내 수리적 특성이 열환경 변화에 미치는 영향 평가: 청계천을 대상으로)

  • Kim, Jeong-Ho;Lee, Ju-Seung;Yoon, Yong-Han
    • Journal of Environmental Policy
    • /
    • v.14 no.2
    • /
    • pp.3-25
    • /
    • 2015
  • Our goal is to verify how changes in water's hydraulic characteristics after urban regeneration stream can affect any possible transformation of its thermal environment. To that end, we analyzed changes in numerous physical characteristics the subject stream along with the meteorological factors and thermal environment affected by it. Cheonggyecheon was selected as our subject as it is a great example of successful urban regeneration stream. As for physical characteristics, we allocated Type I (0.0%) and Type II (20.2%), depending on the green coverage ratio. As for numerical characteristics, at the point of Ba in which the riffle ends, the water temperature fell by $0.2^{\circ}C$ and the flow increased from 0.7m/s to 0.9 m/s with the dissolved oxygen increasing from 0.5mg/L to 0.6mg/L. As for meteorological factors surrounding the subject stream, the temperature dropped from $1.1^{\circ}C$ to $1.4^{\circ}C$ on average and relative humidity increased from 6.6% to 8.7%. Furthermore, there was an irregular change in wind velocity. According to the result of the Wet Bulb Globe Temperature (WBGT), the change in the values of Type I and II inside and on the surface of the subject stream was negligible. The downstream temperature in Type I fell from $0.3^{\circ}C$ to $0.6^{\circ}C$ and by $0.8^{\circ}C$ in Type II. As for vertical cooling effect, the change of water level was 120cm in Type I and 140cm in Type II. As for horizontal cooling effects, the value of Type I was increased from the point of Ba where the riffle ends and the value of Type II was on a steady decline.

  • PDF

A Way for Creating Human Bioclimatic Maps using Human Thermal Sensation (Comfort) and Applying the Maps to Urban and Landscape Planning and Design (인간 열환경 지수를 이용한 생기후지도 작성 및 도시·조경계획 및 디자인에의 적용방안)

  • Park, Soo-Kuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.1
    • /
    • pp.21-33
    • /
    • 2013
  • The purpose of this study is to find applicabilities of human bioclimatic maps, using human thermal sensation(comfort) in summer, with microclimatic in situ data and computer simulation results at the study site of downtown Daegu. This includes the central business district(CBD) area and two urban parks, the Debt Redemption Movement Memorial Park and the 2.28 Park, for urban and landscape planning and design. Climatic data and urban setting information for the analysis of human thermal sensation were obtained from in situ measurement and the geographic information system data. As a result, the CBD had higher air temperature than the parks when the wind speed was low. Relative humidities were opposite to the air temperature. Especially, same directional streets with local wind direction had lower air temperature than streets perpendicular to the wind direction. The most important climatic variable of human thermal sensation in summer was direct beam solar radiation. Also, creating shadow areas would be the most relevant method for modifying hot thermal environments in urban areas. The most effective method of creating shadow patterns was making a tree shadow over a pergola, and the second best one was making a tree shadow on the front of north directional building walls. Moreover, how to plant trees for creating shadow patterns was important as well as what kind of trees should be planted. The results of human thermal sensation were warm to very hot at sunny areas and neutral to warm at shaded ones. At the sunny areas, wide, squared shape areas had a little bit higher thermal sensation than those of narrow streets. The albedo change of building walls 0.15 and ground surface 0.1 could change 1/6 of a sensation level at the shaded areas and 1/3 at the sunny ones. These microclimatic approaches will be useful to find appropriate methods for modifying thermal environments in urban areas.

The Effects of Pergola Wisteria floribunda's LAI on Thermal Environment (그늘시렁 Wisteria floribunda의 엽면적지수가 온열환경에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.115-125
    • /
    • 2017
  • This study was to investigate the user's thermal environments under the pergola($L\;7,200{\times}W\;4,200{\times}H\;2,700mn$) covered with Wisteria floribunda(Willd.) DC. according to the variation of leaf area index(LAI). We carried out detailed measurements with two human-biometeorological stations on a popular square Jinju, Korea($N35^{\circ}10^{\prime}59.8^{{\prime}{\prime}}$, $E\;128^{\circ}05^{\prime}32.0^{{\prime}{\prime}}$, elevation: 38m). One of the stations stood under a pergola, while the other in the sun. The measurement spots were instrumented with microclimate monitoring stations to continuously measure air temperature and relative humidity, wind speed, shortwave and longwave radiation from the six cardinal directions at the height of 0.6m so as to calculate the Universal Thermal Climate Index(UTCI) from $9^{th}$ April to $27^{th}$ September 2017. The LAI was measured using the LAI-2200C Plant Canopy Analyzer. The analysis results of 18 day's 1 minute term human-biometeorological data absorbed by a man in sitting position from 10am to 4pm showed the following. During the whole observation period, daily average air temperatures under the pergola were respectively $0.7{\sim}2.3^{\circ}C$ lower compared with those in the sun, daily average wind speed and relative humidity under the pergola were respectively 0.17~0.38m/s and 0.4~3.1% higher compared with those in the sun. There was significant relationship in LAI, Julian day number and were expressed in the equation $y=-0.0004x^2+0.1719x-11.765(R^2=0.9897)$. The average $T_{mrt}$ under the pergola were $11.9{\sim}25.4^{\circ}C$ lower and maximum ${\Delta}T_{mrt}$ under the pergola were $24.1{\sim}30.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average $T_{mrt}$ compared with those in the sun and was expressed in the equation $y=0.0678{\ln}(x)+0.3036(R^2=0.9454)$. The average UTCI under the pergola were $4.1{\sim}8.3^{\circ}C$ lower and maximum ${\Delta}UTCI$ under the pergola were $7.8{\sim}10.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average UTCI compared with those in the sun and were expressed in the equation $y=0.0322{\ln}(x)+0.1538(R^2=0.8946)$. The shading by the pergola covered with vines was very effective for reducing daytime UTCI absorbed by a man in sitting position at summer largely through a reduction in mean radiant temperature from sun protection, lowering thermal stress from very strong(UTCI >$38^{\circ}C$) and strong(UTCI >$32^{\circ}C$) down to strong(UTCI >$32^{\circ}C$) and moderate(UTCI >$26^{\circ}C$). Therefore the pergola covered with vines used for shading outdoor spaces is essential to mitigate heat stress and can create better human thermal comfort especially in cities during summer. But the thermal environments under the pergola covered with vines during the heat wave supposed to user "very strong heat stress(UTCI>$38^{\circ}C$)". Therefore users must restrain themselves from outdoor activities during the heat waves.