• Title/Summary/Keyword: 풍동 시험

Search Result 280, Processing Time 0.033 seconds

Analysis on Heat Loss of Single-span Greenhouse Using Small-scaled Wind Tunnel (소형풍동을 이용한 단동 비닐온실의 열손실 분석)

  • Kim, Young Hwa;Kim, Hyung kow;Lee, Tae suk;Oh, Sung sik;Ryou, Young sun
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2020
  • The objective of this study is to analyze the heat transfer loss of covering materials in a single-span plastic greenhouse under the steady-state wind environment. To achieve this objective, the following were conducted: (1) design of a small-scaled wind tunnel (SCWT) to analyze heat losses of the greenhouse and its performance; (2) determination of the overall heat transfer coefficient (OHTC) for the covering materials using a small-scaled greenhouse model. The SCWT consists of the blowing, dispersion, steady flow, reduction and testing areas. Each part of the SCWT was customized and designed to maintain air flow at steady state and to minimize the variances in the SCWT test. In this study, the OHTCs of the covering materials were calculated by separating each with the roof, side wall, front and back of the small-scaled greenhouse model. The results of this study show that the OHTC of the roof increases as wind speed increases but the zones in which the increase rate of the OHTC decreased, were distinguished by wind tunnel wing speed of 2 ms-1. For the side wall, the increase rate of the OHTC was particularly higher in the 0-1 ms-1 zone.

Multi-copter Wind-tunnel Test (멀티콥터 풍동시험)

  • Hwang, SeungJae;Cho, TaeHwan;Kim, YangWon;Chung, JinDeog
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.6
    • /
    • pp.10-16
    • /
    • 2017
  • In order to improve the safety of the multi-copter, Korea Aerospace Research Institute (KARI) performed a wind-tunnel test using an octocopter with the maximum takeoff weight (MTOW) of 28 kg. The wind-tunnel test was performed with three different RPM ranges, 3,500, 4,500 and 5,500 rpm, and three different wind speeds, 3.5, 5 and 7 m/sec. The tested range of the angle of attacks was $-40^{\circ}$ to $20^{\circ}degree$ and ${\pm}90^{\circ}degree$. Vortex ring state (VRS) of the tested multi-copter was located around the vertical descending speed of 6 m/sec and the decrement of thrust was about 13 % at the time of testing. Compared with the single propeller wind-tunnel test result, the propeller efficiency of the octocopter dropped to 10 to 15% depending on the propeller RPM. It is hypothesized that the obtained aerodynamic characteristics by the wind-tunnel test will be used to improve the performance and wind resistance of the multi-copter.

The Design of Low-Noise, Low-Turbulence Acoustic Wind Tunnel (저 소음, 저 난류 강도를 갖는 음향풍동의 설계)

  • 전완호;차희범;이덕주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.298-304
    • /
    • 1995
  • 유동이 있는 경우 발생하는 소음에 대한 실험적 연구는 풍동과 무향실이 결합된 음향풍동에서 수행될 수 있다. 이러한 음향풍동은 팬, 수축부, 수집부, 확산부 그리고 무향실에 주의해서 설계되어야 하고 특히 각 부분에서 발생할 수 있는 이차소음을 최소화하도록 설계되어야 한다. 최종적으로 소음기와 흡음재를 이용해서 팬소음과 이차소음의 전파를 줄인다. 본 음향풍동은 개방형 흡입식(open suction type)으로 시험부에서 유속 62.8m/s, 난류강도 0.1%이하, 배경소음 50-55dB 이하로 설계되었다. 이러한 조건을 만족시키기 위하여 하니콤과 6장의 스크린이 있는 정체실과, 21:1의 수축비를 갖는 수축부를 이용하여 난류강도를 낮추고, 흡음재와 90도 각도의 모서리 그리고 공명형과 소산형 소음기로 소음의 전파를 줄였다.

  • PDF

Construction and Performance Test of Ground Test Facility for the Hypersonic Propulsion System (극초음속 추진기관 지상시험 설비 구축 및 성능 시험)

  • Lee, Hyoung-Jin;Lee, Bok-Jik;Kim, Sei-Hwan;Jeung, In-Seuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.41-44
    • /
    • 2007
  • Ground test facility for the hypersonic propulsion system was designed, constructed and performance test was conducted. The design point was selected using quasi,1-Dimensional CFD analysis before the conceptual design for construction of hypersonic facility After that, specific designs for performance and components were completed using unit analysis CFD code and performance tests were conducted for the various operation conditions.

  • PDF

Aerodynamic Analysis of 18% Thick Airfoil(Case 1) with Computational Fluid Dynamics (전산해석을 활용한 두께비 18%익형(Case1)의 공력특성 분석)

  • Kim, Cheolwan;Lee, Yung-gyo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.3
    • /
    • pp.212-216
    • /
    • 2017
  • Aerodynamic analysis for the airfoil, KARI-11-180 having 18% thickness ratio, was performed with CFD techniques. The boundary layer grid was generated by projecting the wall grid normally and fine grid was placed behind the trailing edge to capture the wake accurately. The distance to the far boundary is 100 chords and the flow condition is same as the wind tunnel test condition. Transition SST and DES turbulence models were utilized for accurate prediction of the transiton point. The predicted lift is higher but the drag is predicted lower than the wind tunnel test. 3-dimensional results with airfoil models of which aspect ratio were 2 and 5 were compared with 2-dimensional results.

The Calculation of Propeller Thrust using Semi-infinite Helical Vortices and a Wind tunnel Test (나선와류를 이용한 프로펠러 추력계산과 풍동 시험 연구)

  • Park, Young-Min;Kim, Beom-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.9
    • /
    • pp.816-822
    • /
    • 2011
  • In this study, a program has been coded to evaluate propeller thrust rapidly following the effects of propeller shapes and the environmental facts. At this time, Semi-infinite Helical Vortices model is used to predict the induction factor which is introduced by Kawada. This program is based on Wrench's Propeller lifting line theory, and it can predict aerodynamic coefficients such as thrust, power, and efficiency. First of all, this program is compared with test results of NACA reports to verify of the reliability. Secondly, subsonic wind tunnel test has been performed following variations of propeller's rpm and inflow velocities.

Analysis and Flight Test of XKO-1 Store Separation (저속통제기 외부장착물 분리해석 및 비행시험)

  • Lee, Seung-Soo;Kim, Sang-Jin;Kim, Myung-Seong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.5
    • /
    • pp.24-29
    • /
    • 2004
  • In this paper, we summarize the results of free drop wind tunnel test, separation analysis and flight test in order to verify the safety during the separations of an external fuel tank and the LAU-131 rocket launcher from XKO-l. The wind tunnel test was conducted to show the safety in free drop of the stores and to gather the trajectory data for fine tune of MSAP(Multi-body Separation Analysis Program). The enhanced MSAP was then used to predict the trajectories of the stores with and without the ejector forces. A correlation of MSAP results for free drop case was also made to show the safety of jettison with the free drop type bomb rack. Moreover, the flight test was conducted. and its results were compared to analysis results. Finally, the safe jettison boundary was determined from the flight test.

Performance Evaluation of Measuring Instrument for Infra-Red Signature Suppression System Model Test (적외선 신호저감 장치 모형시험을 위한 계측기의 성능평가)

  • SeokTae Yoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.21-27
    • /
    • 2023
  • Modern naval ships install an Infra-Red Signature Suppression system (IRSS) in their exhaust pipe to reduce infrared signature emitted to the outside. In addition, naval ships are strategic assets with a very long life cycle, so high reliability of the performance of the equipment on board must be guaranteed. Therefore, equipment such as IRSS is evaluated for performance through model testing at the design stage. A variety of measuring instruments are used in IRSS model testing, and the reliability of these instruments must also be guaranteed. In this paper, a study was conducted to evaluate the reliability of measurement equipment used in IRSS model testing. The test equipment and instruments used were a hot gas wind tunnel, pitot tube, digital differential pressure gauge, thermocouple sensor, and digital recorder. As the fan speed of the hot gas wind tunnel increased, the measurement deviation of the flow decreased, and the temperature output of the thermocouple sensor showed differences in response time and stability depending on the method used.

Study on Model Support Interference of the Scaled NASA Common Research Model in Small Low Speed Wind Tunnel (소형 저속 풍동에서 NASA 표준 연구 모형의 모형지지부 효과 연구)

  • Kim, Namgyun;Cho, Cheolyoung;Ko, Sungho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.5
    • /
    • pp.56-64
    • /
    • 2020
  • A wind tunnel test of 29.7% scaled model of NASA Common Research Model was performed in small low speed wind tunnel. The wind tunnel model was fabricated in Aluminium in consultation with NASA Langley Research Center and AIAA Drag Prediction Workshop committee members. The static aerodynamic forces and moments were measured at a relatively low Reynolds number of 0.3 × 106 due to tunnel capability limitations. Pitching moment of three types of model support(Fin sting, Blade sting and Belly sting) were compared. The pitching moment for corrected Belly sting and Fin sting were similar. The result of pitching moment for Blade sting was very small.

Numerical Analyses and Wind Tunnel Tests of a Propeller for the MAV Propulsion (초소형 무인기 추진용 프로펠러의 전산해석 및 풍동시험)

  • Cho, Lee-Sang;Lee, Sea-Wook;Cho, Jin-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.10
    • /
    • pp.955-965
    • /
    • 2010
  • The MH-75 propeller for the MAV propulsion is designed using a free vortex design method which considers design parameters such as the hub-tip ratio, the twist angle distribution, the maximum camber location and the chord length of the propeller blade. Aerodynamic characteristics of the MH-75 propeller are predicted by changing the flight speed using the frequency domain panel method. And, the thrust characteristics of the MH-75 propeller are measured using the balance system of the subsonic wind tunnel for the validation of numerical results. The performance characteristics of the MH-75 propeller satisfied with design requirements. Numerical results of the MH-75, which are predicted by the frequency domain panel method, are more agree with experimental results compare with XFOIL.