• Title/Summary/Keyword: 품질관리장치

Search Result 202, Processing Time 0.03 seconds

A Resource Management Scheme Based on Live Migrations for Mobility Support in Edge-Based Fog Computing Environments (에지 기반 포그 컴퓨팅 환경에서 이동성 지원을 위한 라이브 마이그레이션 기반 자원 관리 기법)

  • Lim, JongBeom
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.4
    • /
    • pp.163-168
    • /
    • 2022
  • As cloud computing and the Internet of things are getting popular, the number of devices in the Internet of things computing environments is increasing. In addition, there exist various Internet-based applications, such as home automation and healthcare. In turn, existing studies explored the quality of service, such as downtime and reliability of tasks for Internet of things applications. To enhance the quality of service of Internet of things applications, cloud-fog computing (combining cloud computing and edge computing) can be used for offloading burdens from the central cloud server to edge servers. However, when devices inherit the mobility property, continuity and the quality of service of Internet of things applications can be reduced. In this paper, we propose a resource management scheme based on live migrations for mobility support in edge-based fog computing environments. The proposed resource management algorithm is based on the mobility direction and pace to predict the expected position, and migrates tasks to the target edge server. The performance results show that our proposed resource management algorithm improves the reliability of tasks and reduces downtime of services.

An experimental study on the quality characteristics of recycled aggregates produced by gutter type roll crusher.(I) (거터타입 파쇄장치를 적용한 순환골재 생산시스템의 성능분석 및 품질특성에 대한 실험적 연구 (I))

  • Kwon, Hyuk-Joon;An, Seon-Hee
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.493-496
    • /
    • 2008
  • Recently, shortage of natural aggregates resources and the amount of waste concrete hsve been rapidly increased, the technique of aggregates manufacturing of waste concrete is damanded. In this study, we evaluated the performance of gutter type roll crusher. Gutter type roll crusher is showed enhanced producing manufacturing ability. The gutter type roll crusher achieved more friction energy than general roll crusher, also a mount of producing showed same results.

  • PDF

FMEA for rotorcraft landing system using Dempster-Shafer evidence theory (Dempster-Shafer 증거 이론을 이용한 회전익 항공기 착륙장치의 FMEA)

  • Na, Seong-Hyeon;So, Hee-Soup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.76-84
    • /
    • 2021
  • The quality assurance activities can detect the factors that affect the quality based on risk identification in the course of mass production. Risk identification is conducted with risk analysis, and the risk analysis method for the rotorcraft landing system is selected by failure mode effects analysis (FMEA). FMEA is a method that detects the factors that can affect the product quality by combining severity, occurrence, and detectability. The results of FMEA were prioritized using the risk priority number. On the other hand, these methods have certain shortcomings because the severity, occurrence, detectability are weighted equally. Dempster-Shafer evidence theory can conduct uncertainty analysis for the opinions with personal reflections and subjectivity. Based on the theory, the belief function and the plausibility function can be formed. Moreover, the functions can be utilized to evaluate the belief rate and credibility. The system is exposed to impact during take-off and landing. Therefore, experts should manage failure modes in the course of mass production. In this paper, FMEA based on the Dempster-Shafer evidence theory is discussed to perform risk analysis regarding the failure mode of the rotorcraft landing system. The failure priority was evaluated depending on the factor values. The results were derived using belief and plausibility function graphs.

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.

Seismic Isolation Effects Due to the Difference Between the Center of Mass of the Building and the Center of Stiffness of Isolation Layer (건물의 질량중심과 면진층의 강성중심 차이에 따른 면진효과)

  • Hur, Moo-Won;Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.107-115
    • /
    • 2014
  • In this study, we examined the seismic isolation effects due to the difference between the center of mass of the building and the center of stiffness of isolation layer. Because the base isolation technique is a technique that is highly dependent on the performance of seismic isolation devices installed on the seismic isolation layer, we have to examine the horizontal stiffness of seismic isolation devices after making them. If difference between the design stiffness and the actual stiffness of the seismic isolation device occurred, a big problem may be generated in the upper members on the seismic isolation layer. The analytical results show that the more eccentricity increases, the more maximum response acceleration, story shear and the member forces of the upper part of the structure increases, and the damage is expected to be in excess. Therefore, it is recommended that if possible, isolation devices have to be designed to coincide the center of mass of the building with the center of stiffness of isolation layer. If not after making isolation devices, they need to be relocated to prevent the eccentricity.

Quality Tests for the Knee-Orthosis Velcro and Locking System (무릎보조기 벨크로 및 잠금장치에 대한 품질시험 연구)

  • Jung, Se-Wook;Seo, Won-San;Cho, KiHun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.275-283
    • /
    • 2016
  • In this study, three knee-orthoses (dial lock type, medium size, right side) were used for a quality level test (static bending test and solidity test of the locking system) of the knee-orthosis locking system. In the static bending test, a smaller maximum load was observed in samples A and C compared to the reference standard value (KS P 8408 standard value: 1000 N, sample A: 865 N, sample C: 833 N). In addition, in the solidity test of the locking system, a smaller maximum load was observed in the all samples compared to the referenced standard value (KS P 8411 standard value: 200 N, sample A: 41 N, sample B: 97 N, sample C: 54 N). Korean industrial standards for knee-orthoses and systematic test methods are lacking. Therefore, a systematic management plan for knee-orthoses is required. The result of the current study showed that a systematic management plan for the knee-orthosis locking system is required. In particular, the development of a quantitative and objective test method is needed. The findings of the current study may be useful for monitoring the quality of the knee-orthosis locking system and may provide foundational information for the development of a quantitative and objective test method.

The Attractant Effects of LED Lights on Aphidius colemani (콜레마니진디벌에 대한 LED 광원의 유인효과)

  • Eun Hye, Ham;Yun Bok, Nam;Hye Jeong, Jun;Young Gyun, Park;Un Taek, Lim;Young Su, Lee
    • Korean journal of applied entomology
    • /
    • v.61 no.4
    • /
    • pp.615-622
    • /
    • 2022
  • In this study, we sought to determine an appropriate LED light source that can be applied for the quality control of Aphidius colemani. Four LED light sources (385, 405, 450, and 660 nm) were evaluated in a Y-tube experiment (choice test) using a 5,000-k white LED as a control. The 385 nm LED light source was found to have attractant effect on A. colemani. In a no-choice test (Y-tube experiment) evaluating the remaining three LED light sources (385, 405, and 450 nm), the attractiveness of these light sources for A. colemani was high in the order 450 nm > 385 nm > 405 nm light, with no statistically significant differences between 450 nm and 385 nm. Given that 385 nm LED illumination may cause skin damage, we selected 450 nm LEDs for application in a device used for the quality control of A. colemani, which we subsequently demonstrated to have an attraction rate of 87.4%. We believe the findings of this study will make a valuable contribution to the quality control of natural enemies.

The Design and Implementation of an Emergency Video Call Integrated Management System based on VoIP (VoIP기반 승강기 비상 화상통화 통합 관리 시스템 설계 및 구현)

  • Kim, Woon-Yong;Kim, SoonGohn
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.12
    • /
    • pp.93-99
    • /
    • 2017
  • The elevator system combines various convergence technologies with the development of ICT technology. Emergency call devices which are safety related devices is applied as an obligation of the elevator and those scope also varies. In this paper, we propose an integrated model that overcomes the limitations of existing voice emergency call devices and efficiently manages and manages video call based service structures in VoIP based on wired and wireless environments. This method effectively manages and operates various lift data and video records in the elevator between the manager, the server and the user. And also It is possible to secure the quality of video call in VoIP and cloud service environment and increase the reliability of safety management and enhance various service environment by creating an integrated structure utilizing various data and additional services in the elevator.

Simplistic QA for an Enhanced Dynamic Wedge using the Reversed Wedge Pair Method (역방향 조사방식을 통한 동적쐐기의 품질관리)

  • Lee Jeong Woo;Hong Semie;Suh Tae Suk
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.161-166
    • /
    • 2004
  • A simplistic quality assurance (QA) method was designed for a Linac built-in enhanced dynamic wedge (EDW), which can be utilized to make wedged beam distributions. For the purpose of implementing the EDW symmetry QA, a film dosimetry system, low speedy dosimetry film, film densitometer and 3D RTP system were used, and the films irradiated by means of a 60$^{\circ}$ Reversed wedge pair (REWP) method. The profiles were then analyzed in terms of their symmetries, including partial treatment, which is the case of stopping it abruptly during EDW irradiation, and the measured and calculated values compared using the Cad Plan Golden Segmented Treatment Table (Golden STT). The result of this experiment was in good agreement, within 1 %, of the 'reversed wedge pair counterbalance effect'. For the QA of the effective wedge factor (EWF), the authors measured EWFs in relation to the 10$^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$ EDW, which were compared with the calculated values using the correction factor derived from the Golden STT and the log files produced automatically during the process of EDW irradiation. By means of this method it was capable of check up the safety of effective wedge factor without any other dosimetry system. The EDW QA was able to be completed within 1 hour from irradiation to analysis as a consequence of the simplified QA procedure, with maximized effectiveness. Unlike the metal wedge system, the EDW system was heavily dependent on the dose rates and jaw movements; therefore, its features could potentially cause inaccuracy. The frequent simplistic QA for the EDW is essential, and could secure against the flaw of dynamic treatment that uses the EDW.

  • PDF

Development of the Control Software for Modular Power Distribution Unit (가변모듈형 전원분배장치 운용 S/W 개발)

  • Choi, Hyo-Yul;Moon, Chang-Hee;Kwon, Seong-Won;Shin, Jun-Seob;Kim, Woong-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1232-1233
    • /
    • 2011
  • 본 개발은 에너지 수요관리, 전력품질감시, 전기안전감시 및 설비감시가 가능한 정보통신실 기반설비용 전원분배장치 운용 S/W 개발에 관한 것으로써, 분전반 단위의 전력 및 에너지 관련정보, 전기기기 및 에너지 상태 정보, 장치 상태 정보를 실시간으로 취득 원격에서 감시 및 분석/통계 할 수 있다.

  • PDF