• Title/Summary/Keyword: 표현밀도

Search Result 157, Processing Time 0.036 seconds

The effect of external influence and operational management level on urban water system from water-energy nexus perspective (물-에너지 넥서스 관점에서 외부영향과 운영관리 수준이 도시물순환시스템에 미치는 영향)

  • Choi, Seo Hyung;Shin, Bongwoo;Song, Youngseok;Kim, Dongkyun;Shin, Eunher
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.9
    • /
    • pp.587-602
    • /
    • 2023
  • Due to climate change, population growth, and economic development, the demand for water in the urban water system (UWS) and the energy required for water use constantly increase. Therefore, beyond the traditional method of considering only the water sector, the Nexus approach, which considers synergies and trade-offs between the water and energy sectors, has begun to draw attention. In previous researches, the Nexus methodology was used to demonstrate that the UWS is an energy-intensive system, analyze the water-energy efficiency relationship surrogated by energy intensity, and identify climate (long-term climate change, drought, type), geographic characteristics (topography, flat ratio, location), system characteristics (total supply water amount, population density, pipeline length), and operational management level (water network pressure, leakage rate, water saving) effects on the UWS. Through this, it was possible to suggest the direction of policies and institutions to UWS managers. However, there was a limit to establishing and implementing specific action plans. This study built the energy intensity matrix of the UWS, quantified the impact of city conditions, external influences, and operational management levels on the UWS using the water-energy Nexus model, and introduced water-energy efficiency criteria. With this, UWS managers will be able to derive strategies and action plans for efficient operation management of the UWS and evaluate suitability and validity after implementation.

The effect of urban conditions, external influences, and O&M efficiency on urban water system from the perspective of water-energy nexus (도시 여건, 외부 영향 및 운영관리 효율이 넥서스 관점에서 도시 물순환 시스템에 미치는 영향)

  • Choi, Seo Hyung;Shin, Bongwoo;Shin, Eunher
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.31-31
    • /
    • 2022
  • 기후변화, 물 부족, 인구 증가와 도시화로 인한 물 수요 증가, 수질 악화, 노후화된 인프라와 같은 세계적인 물문제의 증가로 인해, 도시 물순환 시스템 관리는 더 큰 어려움을 겪고 있다. 취수, 도·송수, 정수처리, 배·급수, 용수 사용, 하수 집수, 하수 처리, 재이용 및 배출 과정을 포함하는 도시 물순환 시스템의 과정은 매우 에너지 집약적인 활동이며, 이와 같은 에너지 소비는 탄소 배출과 양의 직접적인 상관관계가 있다. 따라서 자원 관리 및 데이터 관리를 최적화하기 위해 넥서스 관점의 접근법이 도시 물순환 시스템에 점차적으로 도입되고 있는 추세이다. 도시 물순환 시스템 넥서스에서는 일반적으로 에너지 인텐시티로 표현되는 물을 위한 에너지를 이해하는 것이 중요하다. 에너지 인텐시티의 차이는 기후(연평균 강수량, 단기 기후 변동성, 기후패턴 등), 지리적 특징(표고차, 평지비, 위치 등), 시스템 특성(총급수량, 인구, 인구밀도, 관로 연장 등) 및 운영관리 효율(수압, 누수율, 에너지 효율 등)과 밀접한 관계가 있다. 그리고 도시 물순환 시스템에서 에너지 관리를 증진시킨 방안은 유지관리 효율 개선(물·에너지 관리전략, 물손실 관리, 수요 관리 및 수요 대응 등), 신기술 도입, 그리고 에너지 회수로 나누어진다. 본 연구에서는 기존 문헌의 자료를 분석하여 도시 물순환 시스템의 각 공정별 에너지 인텐시티를 분석하였으며, 시스템 다이나믹스를 적용하여 다양한 도시 여건(인구, lpcd, 누수율, 취수원, 에너지 인텐시티)에서 외부영향(기후변화, 도시화)과 운영효율 변동(운영효율 향상, 신시술 도입)에 따른 도시 물순환 시스템 내 자원 사용 및 이동을 분석하였다. 에너지 인텐시티는 전체 도시 물순환 시스템, 상수 시스템, 하수시스템에서 각각 2.334 kWh/m3, 1.029 kWh/m3, 1.024 kWh/m3를 나타내었으며, 용수사용, 담수화, 재이용 과정에서는 매우 높은 값이 나타났다. 에너지 인틴시티의 값은 외부 영향에 크게 좌우되는 것으로 분석되었으며, 운영효율의 변동에 따라서 물 및 에너지 사용량은 변화하였지만 에너지 인텐시티의 변동은 크지 않았다. 이에 따라 도시 물순환 시스템을 넥서스 관점에서 관리하기 위해서는 에너지 인텐시티 이외에 물 및 에너지 사용량, 유수수량 관점 에너지 인텐시티, 사용수량 관점 에너지 인텐시티를 종합적으로 고려하는 것이 필요하다.

  • PDF

Effect of Stress Level on Strength Parameters of Cemented Sand (응력조건에 따른 고결모래의 강도정수 평가)

  • Lee, Moon-Joo;Choi, Sung-Kun;Choo, Hyun-Wook;Cho, Yong-Soon;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.5
    • /
    • pp.143-151
    • /
    • 2007
  • The factors affecting the geotechnical properties of cemented sands are known to be relative density, cementation level, stress level, and particle characteristics such as particle size, shape and surface conditions. It has been widely accepted that the friction angle of cemented sands is not affected by cementation while the cohesion of cemented sands was significantly influenced by cementation. The cementation that is a critical component of the strength of cemented sands will be broken with increasing confining pressure and great caution is required in evaluating the cohesion of cemented specimens due to their fragilities. In this study, a series of drained shear tests were performed with specimens at various cementation levels and confining stresses to evaluate the strength parameters of cemented sands. From the experiments, it was concluded that the cohesion intercept of cemented sand experiences three distinctive zone(cementation control zone, transition zone, and stress control zone), as the cementation level and the confining stress varies. In addition, for accurate evaluation of the strength parameters, the level of confining stress triggering the breakage of cementation bond should be determined. In this study, the relationship between the maximum confining stresses capable of maintaining the cementation bond intact and unconfined compression strength of the cemented sand was established.

Estimation of Ultimate Lateral Resistances of Piles Using CPT Cone Resistance in Sand (사질토지반에서 콘관입저항치 $q_c$에 의한 단말뚝의 극한수평단위지지력 평가)

  • Kim, Min-Kee;Kyung, Doo-Hyun;Hong, Jung-Moo;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.71-77
    • /
    • 2008
  • In this study, CPT-based methodology for estimating the ultimate lateral resistance, $p_u$, is proposed and verified for lateral loaded piles in sandy soil. Preexistent methods estimating the ultimate lateral resistance, $p_u$, and the ultimate lateral capacity, $H_u$, of pile have been based on the vertical effective stress, relative density, and the coefficient of lateral earth pressure. Similarly, cone resistance $q_c$ in pure sandy soil is expressed by those essential factors. As correlation between $p_u$ and $q_c$ are normalized with average effective stress ${\sigma}_m$, estimation methodology for the lateral loaded pile of $p_u$ in sandy soil is proposed. The method is verified by calibration chamber test results in pure sand. The standard derivation of estimated $p_u$ is 0.279, and COV (Coefficient Of Variation) of estimated $p_u$ is 0.272. These results showed that the estimated pus by the method are analogous with the measured $p_us$ in calibration chamber test.

PHYSIOANATOMY OF NASOPHARYNGEAL SPACE AND HYPERNASALITY IN CLEFT PALATE (구개열에서 비인두강의 생리해부학적 구조와 과비음과의 연관성 연구)

  • Cho, Joon-Hui;Pyo, Wha-Young;Choi, Hong-Shik;Choi, Byung-Jai;Son, Heung-Kyu;Sim, Hyun-Sub
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.721-728
    • /
    • 2004
  • Velopharyngeal closure is a sphincter mechanism between the activities of the soft palate, lateral pharyngeal wall and the posterior pharyngeal wall, which divides the oral and nasal cavity. It participates in physiological activities such as swallowing, breathing and speech. It is called a velopharyngeal dysfunction when this mechanism malfunctions. The causes of this dysfunction are defects in (1) length, function, posture of the soft palate, (2) depth and width of the nasopharynx and (3) activity of the posterior and lateral pharyngeal wall. The purposes of this study are to analyze the nasopharynx of cleft palate patients using cephalometry and to evaluate the degree of hypernasality using nasometry to find its relationship with velopharyngeal dysfunction. The following results were obtained : 1. In cephalometry, there were significant differences in soft palate length, soft palate thickness, nasopharyngeal depth, nasopharyngeal area, and adequate ratio between two groups. 2. In nasometry, there were significant differences between two groups in vowel /o/ and sentences including oral consonants. 3. In cleft palate patients, though no general correlation was found between Anatomic VPI and nasalance scores, vowel /i/ and sentences including oral consonants were slightly correlated. In conclusion, cephalometry and nasometer results were significantly different between the two groups. Though in the cleft palate group, Anatomic VPI and nasalance scores, which are indices for velopharyngeal closure, excluding the vowel /i/ and sentences including oral consonants show generally no significance.

  • PDF

Soil Carbon and Microbial Activity Influenced by Pasture and Rice Paddy Management (목초재배지 및 벼논 관리 변화에 따른 토양 탄소 및 미생물 활성도)

  • Yoo, Ga-Young;Kim, Hyun-Jin;Kim, Ye-Sol;Jung, Min-Hung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.3
    • /
    • pp.435-443
    • /
    • 2012
  • This study investigated soil carbon storage and microbial activities influenced by different management practices in rice paddies and pastures. Soils under a single-crop farming of rice (CON) and rice-Italian ryegrass rotation farming (IRG) were compared in Jangheung, Jeollanam-do, Seocheon and Cheonan, Chungcheongnam-do. Soils from pastures were analyzed to investigate the effect of duration period (P1, P2, P3) in Namwon, Jeollabuk-do and Seosan, Chungcheongnam-do. In rice paddy, total and particulate carbon (PC) concentrations in the IRG soils were significantly higher than those in the CON soils both in Jangheung and Seocheon where the IRG has been established for three years, whereas carbon concentrations were not significantly different in Cheonan where IRG planting history is only one year. In rice paddy soils, PC was suggested as an early indicator to monitor changes in soil carbon storage followed by adopting different management practices. In pasture, total and PC concentrations increased with duration period especially in the 0-5 cm soils. Contrary to the rice paddy soils, the magnitude of change in PC concentration is not as great as that in total carbon concentration, implying that there is a need to develop a new early indicator other than PC using different fractionation scheme. The soil carbon storage in pasture also increased with years since establishment and the increasing rate was significantly greater in the early stage (0-5 yrs) than the later one (> 5 yrs). Microbial activities measured from fluorescein diacetate (FDA) hydrolysis analysis were significantly lower in the IRG soils than CON soils, whereas no difference was observed in the pastures of different ages. This shows that FDA activity is not a sensitive indicator to differentiate soil qualities influenced by management practices if it is used by itself.

Crystalline lens'curvature change model by Accommdation (조절력에 따른 Crystalline Lens의 곡률 변화 모델)

  • Park, Kwang-Ho;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.181-187
    • /
    • 2002
  • Curvature of Crystalline lens changes by Accommdation's change. When Accommdation gives force vertically to Crystalline lens that is elastic body, length increases for vertex direction. Density distribution and form of Crystalline lens that receive force lean to posterior surface, horizontal force of anterior surface direction is bigger more than horizontal force of posterior surface direction. But, if Accommdation begins to grow more than threshold value, expansity reaches in limit on anterior surface. This time, horizontal force of posterior surface direction is great mored more than horizontal force of anterior surface direction, thickness of posterior surface direction increases because is more than anterior surface direction. Anterior and posterior relationship thickness change difference accomplish the 2-nd funtional line(${\Delta}=B_1D+B_2D^2$) about Accommdation. Thickness (${\Delta}t_a$, ${\Delta}t_p$) difference change curved line of anterior pole-border and border-posterior pole by Accommdation is expressed as following. $${\Delta}t_a=t_a-t_{ao}=t_{max}+t_0{\exp}(-A/B)-t_{ao}$$ $${\Delta}t_p=t_p-t_{po}=t_{min}+t_0{\exp}(A/B)-t_{po}$$ The Parameter value that save in human's Crystalline lens obtain $t_{min}=1.1.06$, $t_0=-0.33$, B=9.32 in anterior, and $t_{max}=1.97$, $t_0=0.10$, B=7.96 etc. in posterior. Vertex curvature radius' change is as following Crystalline lens' anterior and posterior by Accommation $$R=R_0+R_1{\exp}(D/k)$$ The Parameter value that save in human's Crystalline lens obtain $R_{min}=5.55$, $R_1=6.87$, k=4.65 in anterior, and $R_{max}=-68.6$, $R_1=76.7$, k=308.5 in posterior, respectively.

  • PDF

Development and Application of a Methodologyfor Climate Change Vulnerability Assessment-Sea Level Rise Impact ona Coastal City (기후변화 취약성 평가 방법론의 개발 및 적용 해수면 상승을 중심으로)

  • Yoo, Ga-Young;Park, Sung-Woo;Chung, Dong-Ki;Kang, Ho-Jeong;Hwang, Jin-Hwan
    • Journal of Environmental Policy
    • /
    • v.9 no.2
    • /
    • pp.185-205
    • /
    • 2010
  • Climate change vulnerability assessment based on local conditions is a prerequisite for establishment of climate change adaptation policies. While some studies have developed a methodology for vulnerability assessment at the national level using statistical data, few attempts, whether domestic or overseas, have been made to develop methods for local vulnerability assessments that are easily applicable to a single city. Accordingly, the objective of this study was to develop a conceptual framework for climate change vulnerability, and then develop a general methodology for assessment at the regional level applied to a single coastal city, Mokpo, in Jeolla province, Korea. We followed the conceptual framework of climate change vulnerability proposed by the IPCC (1996) which consists of "climate exposure," "systemic sensitivity," and "systemic adaptive capacity." "Climate exposure" was designated as sea level rises of 1, 2, 3, 4, and 5 meter(s), allowing for a simple scenario for sea level rises. Should more complex forecasts of sea level rises be required later, the methodology developed herein can be easily scaled and transferred to other projects. Mokpo was chosen as a seaside city on the southwest coast of Korea, where all cities have experienced rising sea levels. Mokpo has experienced the largest sea level increases of all, and is a region where abnormal high tide events have become a significant threat; especially subsequent to the construction of an estuary dam and breakwaters. Sensitivity to sea level rises was measured by the percentage of flooded area for each administrative region within Mokpo evaluated via simulations using GIS techniques. Population density, particularly that of senior citizens, was also factored in. Adaptive capacity was considered from both the "hardware" and "software" aspects. "Hardware" adaptive capacity was incorporated by considering the presence (or lack thereof) of breakwaters and seawalls, as well as their height. "Software" adaptive capacity was measured using a survey method. The survey questionnaire included economic status, awareness of climate change impact and adaptation, governance, and policy, and was distributed to 75 governmental officials working for Mokpo. Vulnerability to sea level rises was assessed by subtracting adaptive capacity from the sensitivity index. Application of the methodology to Mokpo indicated vulnerability was high for seven out of 20 administrative districts. The results of our methodology provides significant policy implications for the development of climate change adaptation policy as follows: 1) regions with high priority for climate change adaptation measures can be selected through a correlation diagram between vulnerabilities and records of previous flood damage, and 2) after review of existing short, mid, and long-term plans or projects in high priority areas, appropriate adaptation measures can be taken as per this study. Future studies should focus on expanding analysis of climate change exposure from sea level rises to other adverse climate related events, including heat waves, torrential rain, and drought etc.

  • PDF

Analysis of Potential Infection Site by Highly Pathogenic Avian Influenza Using Model Patterns of Avian Influenza Outbreak Area in Republic of Korea (국내 조류인플루엔자 발생 지역의 모델 패턴을 활용한 고병원성조류인플루엔자(HPAI)의 감염가능 지역 분석)

  • EOM, Chi-Ho;PAK, Sun-Il;BAE, Sun-Hak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.60-74
    • /
    • 2017
  • To facilitate prevention of highly pathogenic avian influenza (HPAI), a GIS is widely used for monitoring, investigating epidemics, managing HPAI-infected farms, and eradicating the disease. After the outbreak of foot-and-mouth disease in 2010 and 2011, the government of the Republic of Korea (ROK) established the GIS-based Korean Animal Health Integrated System (KAHIS) to avert livestock epidemics, including HPAI. However, the KAHIS is not sufficient for controlling HPAI outbreaks due to lack of responsibility in fieldwork, such as sterilization of HPAI-infected poultry farms and regions, control of infected animal movement, and implementation of an eradication strategy. An outbreak prediction model to support efficient HPAI control in the ROK is proposed here, constructed via analysis of HPAI outbreak patterns in the ROK. The results show that 82% of HPAI outbreaks occurred in Jeolla and Chungcheong Provinces. The density of poultry farms in these regions were $2.2{\pm}1.1/km^2$ and $4.2{\pm}5.6/km^2$, respectively. In addition, reared animal numbers ranged between 6,537 and 24,250 individuals in poultry farms located in HPAI outbreak regions. Following identification of poultry farms in HPAI outbreak regions, an HPAI outbreak prediction model was designed using factors such as the habitat range for migratory birds(HMB), freshwater system characteristics, and local road networks. Using these factors, poultry farms which reared 6,500-25,000 individuals were filtered and compared with number of farms actually affected by HPAI outbreaks in the ROK. The HPAI prediction model shows that 90.0% of the number of poultry farms and 54.8% of the locations of poultry farms overlapped between an actual HPAI outbreak poultry farms reported in 2014 and poultry farms estimated by HPAI outbreak prediction model in the present study. These results clearly show that the HPAI outbreak prediction model is applicable for estimating HPAI outbreak regions in ROK.

Gastric mucosal immune response of Helicobacter pylori-infected children (Helicobacter pylori 감염 소아에서 위점막 면역반응)

  • Yom, Hye Won;Seo, Jeong Wan
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.5
    • /
    • pp.492-499
    • /
    • 2008
  • Purpose : Helicobacter pylori infection is one of the most common gastrointestinal infections worldwide; it almost invariably causes chronic gastritis. Pediatric studies may provide important insights into the mucosal immune response of H. pylori-infection, as children are not submitted to environmental factors such as alcohol, tobacco and anti-inflammatory medication. The aim of the present study was to investigate the mucosal immune response against H. pylori in clinically well-defined groups: H. pylori-positive (divided into peptic ulcer disease and gastritis) and H. pylori-negative control. Methods : Antral biopsies were obtained from 45 children undergoing an upper GI endoscopy for dyspeptic symptoms. T cells (CD3+, CD4+, CD8+) and B cells (CD20+) were analyzed by quantitative immunohistochemistry. The correlation of lymphocyte subsets of gastric mucosa with histology was evaluated. Results : T cells (CD3+, CD4+, CD8+) and B cells (CD20+) were significantly increased in the lamina propria of H. pylori-positive group (P<0.01). CD8+ T cells were significantly increased in the lamina propria of the H. pylori-positive peptic ulcer disease (P<0.01). Within the epithelium, only CD4+ T cells were significantly increased in the H. pylori-positive group (P<0.01). Gastric histological parameters had a closer correlation with lymphocytes in the lamina propria than intraepithelial lymphocytes. Conclusion : This study suggests that both T cells and B cells in the lamina propria play important roles in the local immune response of H. pylori-infected children. Furthermore, it remains to be elucidated whether CD8+ T cells in the lamina propria may contribute to peptic ulcer formation in H. pylori-infected children.