• Title/Summary/Keyword: 표준세척

Search Result 39, Processing Time 0.022 seconds

Differentiation of mixed bacterial populations by modified gram stain (수정된 Gram 염색법에 의한 혼합세균 개체군의 분별 측정)

  • 장진경;임종락;정계효;한홍의
    • Korean Journal of Microbiology
    • /
    • v.25 no.3
    • /
    • pp.244-248
    • /
    • 1987
  • Attempts were made to enumerate the number of Gram positive and negative bacteria in the development of natural fermentation rapidly and simultaneously. A general Gram stain was applied to this study. The number of cells by Gram stain was proportional to the cell turbidity by spectrophotometer within a range of 0.7 absorbance at 610nm. The cells washed out during procedures were not exceeded about 8 percentage. The standard error of separate counts in the mixture of Cscherichia coli and Micrococcus luteus was $5.1\pm2.3$%. The possible range of counting was $5.5\times 10^{7}-1.0\times 10^{9}$ cells/ml. Therefore, it is believed that a general Gram stain could be applied to the separate counting of mixture of Fram positive and negative bacterial populations too. In practice, growth kinetics of hemp retting and Kimchi fermentation were presented.

  • PDF

분광타원분석법을 이용한 InAs 유전율 함수의 온도의존성 연구

  • Kim, Tae-Jung;Yun, Jae-Jin;Gong, Tae-Ho;Jeong, Yong-U;Byeon, Jun-Seok;Kim, Yeong-Dong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.162-162
    • /
    • 2010
  • InAs 는 광전자 및 광통신 소자에 널리 이용되는 $In_xGa_{1-x}As_yP_{1-y}$ 화합물의 endpoint 로서, Heterojunction Field-Effect Transistors (HEMTs), Heterojunction Bipolar Transistor (HBT) 등에 중요하게 이용되고, 다양한 소자의 기판으로도 폭넓게 사용되는 물질이다. InAs 의 반도체 소자로의 응용을 위해서는 정확한 광 특성과 밴드갭 값들이 필수적이며, 분광타원편광분석법(ellipsometry) 을 이용한 상온 InAs 유전율 함수는 이미 정확히 알려져 있다. 그러나 상온에서는 $E_2$ 전이점 영역에서 여러 개의 밴드갭들이 중첩되어 있어, 밴드구조계산 등에 필수적인 InAs의 전이점을 정확히 정의하기 어렵다. 또한, 현재의 산업계에서 중요하게 여겨지는 실시간 모니터링을 위해서는 증착온도에서의 유전율 함수 데이터베이스가 필수적이다. 이와 같은 필요성에 의해, 22 K - 700 K 의 온도범위에서 InAs 의 유전율 함수와 밴드갭 에너지에 대한 연구를 수행하였다. InAs bulk 기판을 methanol, acetone, DI water 등으로 세척 한 뒤, 저온 cryostat 에 부착하였다. 분광타원분석법은 표면의 오염에 매우 민감하기 때문에, 저온에서의 응결 방지를 위해 고 진공도를 유지하며, 액체 헬륨으로 냉각하였다. 0.7 - 6.5 eV 에너지 영역에서 측정이 가능한 분광타원편광분석기로 측정한 결과, 온도가 증가함에 따라 열팽창과 phonon-electron 상호작용효과의 증가에 의해, 밴드갭 에너지 값의 적색 천이와 밴드갭들의 중첩을 관찰 할 수 있었다. 정확한 밴드갭 에너지 값의 분석을 위하여 2계 미분을 통한 표준 밴드갭 해석법을 적용하였으며, 22 K 의 저온에서는 $E_2$ 전이점 영역에서 중첩된 여러 개의 밴드갭들을 분리 할 수 있었다. 또한 고온에서의 연구를 통해, 실시간 분석을 위한 InAs 유전함수의 데이터베이스를 확립하였다. 본 연구의 결과는 InAs 를 기반으로 한 광전자 소자의 개발 및 적용분야와 밴드갭 엔지니어링 분야에 많은 도움이 될 것으로 예상한다.

  • PDF

Analyzing the Importance and Performance of Sanitation Management within Childcare Center Foodservice Facilities in Gyeongbuk Province (경북 지역 보육 시설 급식소의 위생 관리에 대한 중요도-수행도 조사)

  • Jung, Hyeon-A;Kim, An-Na;Joo, Na-Mi;Paik, Jae-Eun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.3
    • /
    • pp.385-391
    • /
    • 2011
  • The purpose of this study was to analyze the importance and performance of sanitation management within childcare center foodservice facilities in Gyeongbuk province. The survey involved 248 people who participated in the food hygiene and safety education for childcare center managers in Gyeongbuk province from June to July 2010. A total of 236 survey papers were analyzed statistically by SPSS program. By the method, t-test and importance-performance analysis (IPA) was performed. Among the respondents, facility managers are 40s (41.9%) which accounted the most percentage, and for the type of facility, the largest amount was home (39.9%). The number of preschool children who are under 20 people accounted for 45.3% and food service staffs were accounted for 36.7%. No significant differences were observed for the four items on the IPA, except for the topics "the immediate deal with trash and leftover food" and "minimizing time (within 2 hours) for distribution after cooking" (p<0.001). The average score on the IPA was 4.14 points, and the average score for the importance of the evaluation was 4.49 points out of 5. Finally, childcare facility managers are aware of the importance that is lower than can be done. The results suggest that continuing education is necessary to administrators to manage the health care facility effectively.

Neutron Activation Analysis of Human Hair for Human Health Assessment (인체보건 환경평가를 위한 모발의 중성자방사화분석)

  • Chung, Young-Sam;Kang, Sang-Hoon;Moon, Jong-Hwa;Kang, Young Hwan;Cho, Seung-Yon
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.131-139
    • /
    • 2001
  • There is personal difference in the concentrations of trace elements in human hair according to human life or history suck as occupation, race, sex, age, food habit, social condition and so on. It is also found that the individual's deviation of elemental concentrations is reflecting the degree of environmental pollutants exposure to human body, intakes of food and metabolism. To compare the degree of accumulation in the hair tissue, human hair samples were collected from five positions of head and analyzed by non-destructive neutron activation analysis with and without washing according to IAEA's recommended method. Analytical quality control is performed using the certified reference material. The relative error of Cu, Cr, Na, Co, Mg, As, Se, Zn and those of Mn, Ca, Fe, Sr are within ${\pm}5%$ and ${\pm}10%$, respectively and the relative standard deviation of elements are within ${\pm}10%$. The deviations between the individuals and hair sampling positions were estimated. The deviation of individual was seven times more than that of positions. Under the defined condition, the difference and the correlation of elemental concentrations were compared with two different groups, office and factory workers. The result can be used as a fundamental data for human health and environment assessment.

  • PDF

Synthesis and Isolation of Monoacetyl-DCB and Diacetyl-DCB from 3,3대-dichlorobenzidine(DCB) (디클로로벤지딘으로부터 대사물질의 합성과 분리방법에 대한 연구)

  • Lee, Jin-Heon;Lee, Beom-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.50-55
    • /
    • 2003
  • 3,3-dichlorobenzidine is suspected to be cancinogenic in experimental animal and human. Several studies have investigated excretion of metabolites in urine, hemoglobin adduction and cancer incidence among workers occupationally exposed to 3,3'-dichlorobenzidine. In these researches, metabolites of 3,3'-dichlorobenzidine had a very important role, and were required as highly purity. The purpose of this study was synthesis and isolation of its metabolites from 3,3'-dichlorobenzidine. 3,3'-dichlorobenzidine was partially dissolved in benzene, ether, ethanol and methanol, and completely dissolved in 70% acetic acid on mixtures of citric acid containing less than 1% DCB, pyridine, a mixture of 0.5N NaOH and toluene(1:2), and phenol saturated with 20 mM TRIZA base. DCB, monoacetyl-DCB and diacetyl-DCB were measured by using gas chromatography/mass spectrometry(GC/MS). Detection for checking them was nitrogen phosphorous detection mode(NPD), and for identifying them was selected ion monitoring mode(SIM). The base peaks were 252 m/z in DCB, 252, and 294 m/z in monoacetyl-DCB, and 252, 294 and 336 m/z in diacetyl-DCB, respectively. Diacetyl-DCB was synthesized by titrating DCB solution of pyridine with sufficient acetyl chloride. Precipitation was diacetyl-DCB, which was purity of 98.7%. And its supernatant was composed of DCB, monoacetyl-DCB and diacetyl-DCB. By using acetic acid as controller of acetylation, monoacetyl-DCB was isolated from diacetyl-DCB . And residual pyridine was removed by using acetone. The purity of monoacetyl-DCB was 98.8%.

The History and Development of the Marine Environment QA/QC (Quality Assurance/Quality Control) Management System (해양환경 정도관리제도 운영에 대한 고찰)

  • PARK, MI-OK;PARK, JUN-KUN;KIM, SEONG-GIL;KIM, SEONG-SOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.3
    • /
    • pp.185-200
    • /
    • 2021
  • The Marine Environment QA/QC management system has been operated since 2010 to secure the reliability of data and improve the analysis capabilities of measurement and analysis institutions. From 2010 to 2020, the cumulative number of measurement and analysis institutions participated in the QA/QC management system was 266. And the number of certificates issued by the ministry of oceans and fisheries is 182. A total of 32 reference materials for proficiency testing and interlaboratory comparisons have been developed. They were first developed focusing on items (Nutrients, COD) commonly analyzed in marine environmental measuring network, marine pollution impact surveys, sea area utilization impact assessment, deepsea water surveys, and information network on fishing ground environments. In addition, it is time to expand the filed of the QA/QC management system, such as seawater temperature, salinity, PCBs and PAHs in sediments, which are mainly analyzed in most monitoring programs. On-site assessment has been conducted for 162 laboratories according to ISO/IEC 17025 to evaluate their conformity of the quality management system and deficiency. In terms of management and technology requirements, about 4.2% of organizations showed insufficient division of duties among employees 8.7% of them revealed the lack of employee training. By test item, about 6.3% of organizations showed the lack of standard substance management and the state of the cleaning glassware was pointed out in about 5.4% of them. The QA/QC management system should be continuously supplemented by identifying the causes of nonconformities and area for improvement.

Study for Diagnostic Efficacy of Minibronchoalveolar Lavage in the Detection of Etiologic Agents of Ventilator-associated Pneumonia in Patients Receiving Antibiotics (항생제를 사용하고 있었던 인공호흡기 연관 폐렴환자에서의 원인균 발견을 위한 소량 기관지폐포세척술의 진단적 효용성에 관한 연구)

  • Moon, Doo-Seop;Lim, Chae-Man;Pai, Chik-Hyun;Kim, Mi-Na;Chin, Jae-Yong;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.321-330
    • /
    • 1999
  • Background : Early diagnosis and proper antibiotic treatment are very important in the management of ventilator-associated pneumonia (VAP) because of its high mortality. Bronchoscopy with a protected specimen brush (PSB) has been considered the standard method to isolate the causative organisms of VAP. However, this method burdens consumer economically to purchase a PSB. Another useful method for the diagnosis of VAP is quantitative cultures of aspirated specimens through bronchoscopic bronchoalveolar lavage (BAL), for which the infusion of more than 120 m1 of saline has been recommended for adequate sampling of a pulmonary segment. However, occasionally it leads to deterioration of the patient's condition. We studied the diagnostic efficacy of minibronchoalveolar lavage (miniBAL), which retrieves only 25 ml of BAL fluid, in the isolation of causative organisms of VAP. Methods: We included 38 consecutive patients (41 cases) suspected of having VAP on the basis of clinical evidence, who had received antibiotics before the bronchoscopy. The two diagnostic techniques of PSB and miniBAL, which were performed one after another at the same pulmonary segment, 'were compared prospectively. The cut-off values for quantitative cultures to define causative bacteria of VAP were more than $10^3$ colony-forming units (cfu)/ml for PSB and more than $10^4$ cfu/ml for BAL. Results: The amount of instilled normal saline required to retrieve 25 ml of BAL fluid was $93{\pm}32 ml$ (mean${\pm}$SD). The detection rate of causative agents was 46.3% (19/41) with PSB and 43.9% (18/41) with miniBAL. The concordance rate of PSB and miniBAL in the bacterial culture was 85.4% (35/41). Although arterial blood oxygen saturation dropped significantly (p<0.05) during ($92{\pm}10%$) and 10 min after ($95{\pm}3%$) miniBAL compared with the baseline ($97{\pm}3%$), all except 3 cases were within normal ranges. The significantly elevated heart rate during ($l25{\pm}24$/min, p<0.05) miniBAL compared with the baseline ($1l1{\pm}22$/min) recovered again in 10 min after ($111{\pm}26$/min) miniBAL. Transient hypotension was developed during the procedure in two cases. The procedure was stopped in one case due to atrial flutter. Conclusion: MiniBAL is a safe and effective technique to detect the causative organisms of VAP.

  • PDF

Exposure and Risk Assessment for Operator Exposure to Insecticide Acetamiprid during Water Melon Cultivation in Greenhouse using Whole Body Dosimetry (수박 시설재배에서 살충제 Acetamiprid 사용 시 전신노출법에 의한 농작업자의 노출 및 위해성평가)

  • Kim, Eunhye;Lee, Jiho;Sung, Jeonghee;Lee, Jonghwa;Shin, Yongho;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • Assessment for operator's dermal and inhalation exposure to acetamiprid during cultivation of water melon in greenhouse was carried out. For dermal exposure measurement, whole body dosimetry (WBD) was performed as the first trial in Korea. WBD consists of cotton/polyester outer clothes and cotton inner clothes. Hand exposure was measured by washing of nitrile gloves and hands while head exposure was monitored by face/neck wipe technique. Inhalation exposure was monitored with personal air sampling pumps and IOM sampler (glass fiber filter). Analytical limit of quantitation was 2.5 ng/mL. Good reproducibility (C.V < 8.7%), linearity ($R^2$ > 0.99) and recovery (70~119%) were obtained. Field recovery of acetamiprid was 77~95%. During mixing/loading, hand exposure of acetamiprid was about 10 times ($229.7{\mu}g$) more than that of application case ($20.9{\mu}g$). During application, total dermal exposure was $1207.4{\mu}g$. Exposure of lower legs was $1132.1{\mu}g$, which is 93.8% of the total dermal exposure. Inhalation exposure during mixing/loading and application was not detected. Margin of safety (MOS) was calculated for risk assessment using male Korean average body weight (70 kg) and acceptable operator exposure level ($124{\mu}g/kg/day$) to give 140, suggesting that health risk of operator during treatment of acetamiprid for water melon in greenhouse could be safe.

Residue Patterns of Procymidone, Chlorpyrifos and Cypermethrin in Peaches During Cultivation and Storage Period (복숭아의 재배 및 저장기간 중 Procymidone, Chlorpyrifos 및 Cypermethrin의 잔류량 변화)

  • Lee, Yong-Jae;Ko, Kwang-Yong;Won, Dong-Jun;Gil, Geun-Hwan;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.3
    • /
    • pp.220-226
    • /
    • 2003
  • The residue patterns of procymidone, chlorpyrifos and cypermethrin in peaches were examined. The pesticides were sprayed at 15 days before harvest and then were determined the residue at 0, 1, 2, 3, 5, 7, 10 and 15 days after pesticide application and calculated their $DT_{50}$. Also, the degradation patterns at $4^{\circ}C$ and $20^{\circ}C$ during storage period were compared. Biological half-lives of procymidone, chlorpyrifos and cypermethrin in peaches during the cultivation period were 3.1, 7.2 and 10.4 days, respectively. The biological half -life of procymidone was shorter than the others. During the storage period, half-lives of procymidone, chlorpyrifos and cypermethrin were 16.0, 14.3 and 13.1 days at $4^{\circ}C$ and 4.6, 10.2 and 12.9 days at $20^{\circ}C$, respectively. The degradation rates of these three pesticides in storage period were slower than them in cultivation period. Removal rates were $22.2{\sim}82.9%$ by tap water, and $12.5{\sim}88.8%$ by detergent solution.

The Microbiological Evaluation of Environments and Facilities at Food Service Operations in Elementary School (초등학교 단체급식 소의 환경과 급식설비에 대한 미생물 평가)

  • 정동관;류은순
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.2
    • /
    • pp.216-220
    • /
    • 2002
  • The microbiological examinations of food service operations were conducted for the hygienic evaluation at four elementary schools in Busan, Korea. Total one hundred and seventy two swabbed samples using sponge were collected from the surface of environments, utensils and equipments of food service facilities and analyzed by measuring the total, coliform and psychrotrophic count. Sampling sites were the surfaces of floors, drains, walls, knives, cutting boards, rubber gloves, vinyl aprons, plastic containers, carriers, shelves, trays, dry shelves, electric tray dryer, food containers, soup containers, rice cookers, frying pans, boiling cookers, refrigerators, dumb waiters and dishwashers. The swabbed samples kept in an ice-parked box were transported to a laboratory and analyzed. The results demonstrated that the degree of contamination depended on the sampling sites. Averages of total counts of surface swab samples were ranged from 0.62 to 7.79 Log CFU/200 cm$^2$. The level of coliforms were ranged from not detectable to 5.26 Log CFU/200 cm$^2$, and those of psychrotrophs from not detectable to 6.15 Log CFU/200 cm$^2$. The severely contaminated sites were dumb waiters, drains, rice cookers, knives, plastic containers and floors. Also cutting boards, rubber gloves, carriers, drying shelves, vinyl aprons, boiling cookers, soup containers, frying pans and refrigerators were highly contaminated with the level of abode 3.5 Log CFU/200 cm$^2$. Therefore, those sites should be focused and controlled according to control points of sanitation standard operating procedures (SSOP). Also, periodic microbiological examination in addition to visual examination is recommended on these highly contaminated sites indicated above results at food service operations in elementary school.