• Title/Summary/Keyword: 표준누출

Search Result 62, Processing Time 0.039 seconds

Studies on the Acid Tolerance of Acetobacter sp. Isolated from Persimmon Vinegar (감식초로부터 분리한 Acetobacter sp.의 내산성에 관한 연구)

  • Sim, Kyu-Chang;Lee, Kap-Sang;Kim, Dong-Han;Ryu, Il-Hwan;Lee, Jung-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.574-581
    • /
    • 2001
  • The microbial properties and acid tolerance of the three kinds of Acetobacter sp. isolated from persimmon vinegar were investigated. Acid tolerance was also evaluated. Acetobacter sp. were gram negative, short rod, nonspore forming and motile. They reacted positively catalase, methyl red, oxidation fermentation, Voges-Proskauer and nitrate reduction tests and negative to hydrogen sulfide test and ONPG. Acetobacter sp. showed normal growth curve in Carr broth and there was no significant difference between isolates and (standard on) typical strains such as Acetobacter aceti (KCTC1010), Acetobacter liquefaciens (KCTC2804), Acetobacter diazotrophicus (KCTC 2859). Optimum temperature and initial ethanol concentration in incubation were $30^{\circ}C$ and 6%, respectively. Growth and acid production of Acetobacter sp. were suppressed by the concentration of above 4% acetic acid. The amount of $Mg^{++}$ release from Acetobacter sp. cells in medium was increased by acetic acid, and almost in the concentration of 6% acetic acid. Glycolysis by Acetobacter sp. had optimal pH about 6.0 to 7.0 and more stable in acidic condition than in alkalic. The $H^+-ATPase$ of Acetobacter sp. S-1 and S-3 showed a maximal activity between pH values of approximately 5.5 to 7.5 and 6.0 to 7.5, respectively.

  • PDF

Consequence Analysis of Hydrogen Filling Stations based on Cascade Compressing Systems (케스케이드 방식 압축시스템 기반의 수소충전소에 대한 정성적 위험성평가)

  • Ahn, Byeong-Jun;Rhim, Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.2
    • /
    • pp.13-21
    • /
    • 2021
  • Because of the recent expansion of hydrogen vehicle supply, the installation of hydrogen filling station is expected to gradually expand. This study attempts to predict the damage scale and propose a safer design form based on the scenario that assumes the worst case of a hydrogen station. A Flacs solver using computational fluid dynamics (CFD) was used to predict the damage scale, and the accuracy was verified by comparing it with the experimental results of previous researchers. The damage scale prediction was conducted for hydrogen leakage and explosion, and the prediction target was the KR model based on the measured values. And as a comparative review model, a roofless model was selected without a ceiling. As a result of analyzing the two models, it was possible to confirm the accumulation and retention of hydrogen gas up to 60 vol% or more in the KR model, whereas in the case of the Roofless model, the phenomenon of discharge and diffusion to the outside of the charging station by riding the wall after leakage. I was able to check. In conclusion, it was reviewed that the type of hydrogen charging station without ceiling is more advantageous for safety than the hydrogen filling station model.

A Risk Assessment for A Korean Standard Nuclear Power Plant (한국표준형 원전의 중대사고시 MACCS 코드를 이용한 위험성평가)

  • Hwang, Seok-Won;Jae, Moo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.189-197
    • /
    • 2003
  • The Level 3 PSA being termed accident consequence analysis is defined to assess effects on health and environment caused by radioisotopes released from severe accidents of nuclear power plants. In this study consequence analysis on health effects depending on release characteristics of radioisotopes has been peformed using the 3 MACCS code in severe accidents. The results of this study may contribute to identifying the relative importance of various parameters occurred in consequence analysis as well as to assessing risk reduction accident management strategies. Especially three parameters for the purpose of consequence analysis, such as the release height, the heat content, and the duration time, are used to analyze the variation of early fatalities and latent cancer fatalities. Also, in this study risk assessment using the concept, 'products of uncertainty and consequences', has been performed using consequence of MACCS and frequency on source term category 19 scenarios from IPE (Individual Plant Examination) analysis.

A Study on Determination of Range of Hazardous Area Caused by the Secondary Grade of Release of Vapor Substances Considering Material Characteristic and Operating Condition (물질특성 및 운전조건을 고려한 증기상 물질의 2차 누출에 따른 폭발위험장소 범위 선정에 관한 연구)

  • Seo, Minsu;Kim, Kisug;Hwang, Yongwoo;Chon, Youngwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.13-26
    • /
    • 2018
  • Currently, local regulations, such as KS Code, do not clearly specify how to calculate the range of hazardous area, so the dispersion modeling program should be used to select dispersion. The purpose of this study is to present a methodology of determining the range of hazardous area which is simpler and more reasonable than modelling by using representative materials and process conditions. Based on domestic and overseas regulations that are currently in effect, variables affecting distance to LFL(Lower Flammable Limit) were selected. A total of 16 flammable substances were modelled for substance variables, process conditions variables, and weather conditions variables, and the statistical analysis selected the variables that affect them. Using the selected variables, a three-step classification method was prepared to select the range of locations subject to explosion hazard.

Design of Uni-directional Optical Communication Structure Satisfying Defense-In-Depth Characteristics against Cyber Attack (사이버공격에 대비한 심층방호 특성을 만족하는 단방향 광통신 구조 설계)

  • Jeong, Kwang Il;Lee, Joon Ku;Park, Geun Ok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.12
    • /
    • pp.561-568
    • /
    • 2013
  • Instrumentation and control system in nuclear power plant performs protecting, controling and monitoring safety operation of Nuclear Power Plant. As cyber attack to the control equipment of instrumentation and control system can cause reactor shutdown and radiation release, it is required to design the instrumentation and control system considering cyber security in accordance with regulatory guides and industrial standards. In this paper, we proposed a design method of uni-directional communication structure which is required in the design of defense-in-depth model according to regulatory guides and industrial standards and we implemented a communication board with the proposed method. This communication board was tested in various test environments and test items and we concluded it can provide uni-directional communication structure required to design of defense-in-depth model against cyber attack by analyzing the results. The proposed method and implemented communication board were applied in the design of SMART (system-integrated modular advanced reactor) I&C (instrumentation and control) systems.

Privacy-Enhanced Subject Identification method Embedded in X.509 Certificate (X.509 인증서에 포함된 프라이버시 보호기능을 가진 개인 식별 방법)

  • Lee, Jae-Il;Park, Jong-Wook;Kim, Seung-Joo;Song, Joo-Seok
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.16 no.5
    • /
    • pp.59-66
    • /
    • 2006
  • A Certification Authority issues X.509 public key certificates to bind a public key to a subject. The subject is specified through one or more subject names in the 'subject' or 'subjectAltName' fields of a certificate. In reality, however, there are individuals that have the same or similar names. This ambiguity can be resolved by including a 'permanent identifier' in all certificates issued to the same subject, which is unique across multiple CAs. But, a person's unique identifier is regarded as a sensitive personal data. Such an identifier cannot simply be included as part of the subject field, since its disclosure may lead to misuse. We present a new method for secure and accurate user authentication through the PEPSI included in the standard certificate extension of a X.509 certificate. The PEPSI can be served not only for user authentication but also for the user anonymity without divulging personal information.

Association of Hypercapnia in the First Week of Life with Severe Intraventricular Hemorrhage in the Ventilated Preterm Infants (기계적 환기 요법을 시행 받은 미숙아에서 고탄산혈증과 뇌실내 출혈의 발생과의 관계)

  • Kim, Jeong-Eun;Namgung, Ran;Park, Min-Soo;Park, Kook-In;Lee, Chul;Kim, Myung-Jun
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.34-43
    • /
    • 2010
  • Purpose : The aim of this study was to examine whether hypercapnia during the first seven days of life was associated with severe intraventricular hemorrhage (IVH) in preterm infants requiring mechanical ventilation. Methods : A matched pair analysis was performed for 19 preterm infants with severe IVH(grade$\geq$3) and 38 infants with no severe IVH (normal or grade 1), who required mechanical ventilation for more than seven days. The univariate and multivariate analysis of severe IVH with maximal and minimal $PaCO_2$, averag $PaCO_2$, SD of $PaCO_2$, and difference in the $PaCO_2$ were assessed. The major perinatal factors and maximal ventilator index (VI) were also compared. Results : Infants with severe IVH had a higher maximal $PaCO_2$ (86.1$\pm$18.4 mmHg vs. 60.1$\pm$ 11.6 mmHg, P <0.001) and mean $PaCO_2$ (47.5$\pm$5.6 mmHg vs. 41.2$\pm$6.3 mmHg, P=0.004) and a larger SD or difference in $PaCO_2$ (14.0$\pm$4.4 mmHg vs. 9.0$\pm$2.4 mmHg; 60.3$\pm$20.9 mmHg vs. 35.5$\pm$11.8 mmHg, P <0.001). However the minimal $PaCO_2$ values did not differ between the groups. Disseminated intravascular coagulation, pulmonary hemorrhage, and the air leak syndrome were more frequent in the IVH group than in the controls. The maximal VI on each day was higher in the IVH group. The multivariate logistic regression analysis after controlling for bleeding tendency showed that the air leak syndrome, maximal VI, and maximal $PaCO_2$ were independently associated with severe IVH [OR, 1.324 (95% CI, 1.011-1.733; P=0.041)]. Conclusion : Extreme hypercapnia was significantly associated with severe IVH in preterm infants, after adjustment for major perinatal risk factors. Frequent monitoring of the $PaCO_2$ may be important for early detection of inadvertent hypercapnia and prompt correction of high PaCOS levels.

The Effect of Heat Shock Response on the Tumor Necrosis Factor-$\alpha$-induced Acute Lung Injury in Rats (Tumor Necrosis Factor-$\alpha$로 유도되는 백서의 급성 폐손상에 열충격반응이 미치는 효과)

  • Koh, Youn-Suck;Lim, Chae-Man;Kim, Mi-Jung;Cho, Won-Kyung;Jeoung, Byung-O;Song, Kyu-Young;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1343-1352
    • /
    • 1997
  • Background : Heat-treated cells are known to be protected from lysis by TNF, which is considered to play a central role in the pathogenesis of sepsis-induced acute lung injury. The objective of the study was to investigate the effect of heat shock response by heat-pretreatment on the acute lung injury of the rats induced by intratracheally administered TNF-$\alpha$, Methods : We intratracheally instilled either saline or TNF (R&D, 500ng) with and without heat pretreatment in Sprague-Dawley rats weighing 250~350 g. The heated rats were raised their rectal temperature to $41^{\circ}C$ and was maintained thereafter for 13 minutes at 18 h before intratracheal administration of saline or TNF. After 5 h of intratracheal treatment, lung leak, lung myeloperoxidase activity (MPO) and heat shock proteins were measured in rats. Lung leak index was defined as counts per minute of $I^{25}$ in the right lung divided by counts per minutes of $I^{25}$ in 1.0 ml of blood. All data are expressed as means ${\pm}$SE. Results : There is no difference in acute lung leak index ($0.099{\pm}0.024$ vs $0.123{\pm}0.005$) among the rats given saline intratracheally with and without heat pretreatment, but MPO activity showed a decreased tendency in heat-pretreated rats ($4.58{\pm}0.79\;U/g$) compared with heat-unpretreated rats ($7.32{\pm}0.97\;U/g$) (P=0.064). Rats administered TNF intratracheally with heat-pretreatment had decreased lung leak index ($0.137{\pm}0.012$) and lung MPO activity ($5.51{\pm}1.04\;U/g$) compared with those of heat-unpretreated and TNF-administered rats ($0.186{\pm}0.016$, $14.34{\pm}1.22\;U/g$) (P<0.05 in each). There were no significant difference of lung leak index and MPO activity between TNF-treated rats with heat-pretreatment and saline-treated rats with and without heat-pretreatment. Conclusion : The heat shock response attenuated neutrophil recruitment and acute lung leak induced by intratracheal instillation of TNF-in rats.

  • PDF

Critical Pathway for Operable Gastric Cancer (위암수술 환자에서의 Critical Pathway의 개발과 적용)

  • Song, Kyo-Young;Kim, Seung-Nam;Park, Cho-Hyun
    • Journal of Gastric Cancer
    • /
    • v.5 no.2
    • /
    • pp.95-100
    • /
    • 2005
  • Purpose: Critical pathways (CP), also known as clinical pathways, are management plans that display goals for patients and have led to improved outcomes for many disease entities. This study was aimed at developing a critical pathway for the surgical treatment of gastric cancer patients and evaluating its usefulness. Materials and Methods: A CP was developed and implemented by a team of surgeons, nurses, nutritionists, and administrative officials. Among the 117 patients who received curative gastrectomies for gastric cancer at Kangnam St. Mary's Hospital, The Catholic University of Korea, between October 2003 and August 2004, 26 patients were treated according to the CP. We evaluated its usefulness by comparing the clinical characterisctics, postoperative progress, hospital stays, and costs between the CP and the non-CP groups. Patient satisfaction was also surveyed with questionnaires. Results: Of the initial 26 patients in the CP group, two were excluded from the final evaluation; one patient had a duodenal stump leakage, and the other had a gastric stasis postoperatively. In 8 patients, protocol violation occurred; six patients refused to be discharged on the $7^{th}$ postoperative day, one patient who had an gastric staisis postoperatively stayed for 2 additional days, and one patient who needed ICU care stayed for 4 additional days. The drop-out rate was $7.7\%$ (2/26), and the variance rate was $30.8\%$ (8/26). The mean hospital stay was 11.3 days ($10\~15$ days) for the CP group compared with 17.5 days ($9\∼68$ days) for the non-CP group, resulting in a difference of about 6 days (P<0.05). The mean hospital stays after surgery were 10.3 days ($7\∼68$ days) and 8.3 days ($7\∼12$ days) for the non-CP and the CP groups, respectively, but the difference was statistically not significant (P>0.05). The mean charge during the hospital stay was higher in the non-CP group ( $\\$ 6,292,200) than in the CP group ( $\\$ 4,863,685). The charge per hospital day was higher in the CP group ( $\\$ 430,414) than in the non-CP group ( $\\$ 359,554). Patient satisfaction was higher in the CP group than in the non-CP group. Conclusion: By developing and applying a critical pathway in the surgical treatment of stomach cancer patients, we could reduce the length of hospital stay as well as the cost. A multi-centered prospective study to establish a standard treatment pathway and to demonstrate its effectiveness is needed in the future.

  • PDF

Evaluation of the Size of Emergency Planning Zone for the Korean Standard Nuclear Power Plants (한국표준형 원전에 대한 방사선비상계획구역 범위 평가)

  • Jeon, In-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.215-223
    • /
    • 2003
  • Against major release of radioactive material in nuclear power plant, Emergency Planning Zone(EPZ)s are typically established around nuclear power plants to effectively perform the public protective measures. The domestic methodology to determine the size of the EPZ is similar to that of Japan established in 1980, where calculations were based on the conservative accident source term. The objective of this study is to re-evaluate the validity of established EPZ, the area within the radius of $8{\sim}10km$ around domestic nuclear power plants, using the source terms covering full spectrum of accidents obtained from PSA study of ULJIN 3&4. To evaluate the risks of health effects, the computer code MACCS2(MELCOR Accident Consequence Code System2) was used. The result shows that the existing EPZ can reduce the probability of early fatality adequately for most of the source term categories(STCs) except for STC-14 and STC-19. In case of STC-14 and 19, the evacuation distance of 16km and 13km, respectively, are required. These distances can be reduced by improving emergency preparedness since the sensitivity studies for the public protective actions show that the magnitude of early fatality is largely affected by the time delays in notification and evacuation.