• Title/Summary/Keyword: 표면 열유속

Search Result 128, Processing Time 0.023 seconds

An Investigation of Quantitative Risk Assessment Methods for the Thermal Failure in Targets using Fire Modeling (화재모델링을 이용한 목표 대상물의 열적 손상에 대한 정량적 위험성 평가방법의 고찰)

  • Yang, Ho-Dong;Han, Ho-Sik;Hwang, Cheol-Hong;Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.116-123
    • /
    • 2016
  • The quantitative risk assessment methods for thermal failure in targets were studied using fire modeling. To this end, Fire Dynamics Simulator (FDS), as a representative fire model, was used and the probabilities related to thermal damage to an electrical cable were evaluated according to the change in fire area inside a specific compartment. 'The maximum probability of exceeding the damage thresholds' adopted in a conservative point of view and 'the probability of failure' including the time to damage were compared. The probability of failure suggested in the present study could evaluate the quantitative fire risk more realistically, compared to the maximum probability of exceeding the damage thresholds with the assumption that thermal damage occurred the instant the target reached its minimum failure criteria in terms of the surface temperature and heat flux.

A Combustion Analysis of Surface Fuel Burning Experiment According to Density Variation (밀도에 따른 지표 연료의 연소실험 분석)

  • Kim, Eung-Sik;Kim, Jang-Hwan;Kim, Dong-Hyun;Park, Hyung-Ju;Kim, Jeong-Hun
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • This paper shows combustion characteristics of fallen leaves of Quercus variabilis and Pinus densiflora according to variation of mass densities. Combustion temperature, mass loss rate, flame height, duration of combustion and velocity of hot gas are measured and analyzed. For the experiment 10cm heighted baskets with varying diameters of 20, 30, 40 and 50cm are used for the combustion and the pilot ignition is carried on the top of the fuel. In case of Pinus densiflora mass loss rate, duration of flame, flame height and combustion time become larger as the mass density and diameter of basket increase, on the other hand Quercus variabilis shows saturation characteristics in mass loss rate and flame height. Velocity of hot gas is proportional to flame height.

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

Pilot-scale Applications of a Well-type Reactive Barrier using Autotrophic Sulfur-oxidizers for Nitrate Removal (독립영양 황탈질 미생물을 이용한 관정형 반응벽체의 현장적용성 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Lee, Kyu-Yeon;Moon, Hee-Sun;Kim, Yang-Bin;Woo, Nam-C.;Lee, Jong-Min;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.40-46
    • /
    • 2009
  • The applicability of a well-type autotrophic sulfur-oxidizing reactive barrier (L $\times$ W $\times$ D = $3m\;{\times}\;4\;m\;{\times}\;2\;m$) as a long-term treatment option for nitrate removal in groundwater was evaluated. Pilot-scale (L $\times$ W $\times$ D = $8m\;{\times}\;4\;m\;{\times}\;2\;m$) flow-tank experiments were conducted to examine remedial efficacy of the well-type reactive barrier. A total of 80 kg sulfur granules as an electron donor and Thiobacillus denitrificans as an active bacterial species were prepared. Thiobacillus denitrificans was successfully colonized on the surface of the sulfur granules and the microflora transformed nitrate with removal efficiency of ~12% (0.07 mM) for 11 days, ~24% (1.3 mM) for 18 days, ~45% (2.4 mM) for 32 days, and ~52% (2.8 mM) for 60 days. Sulfur granules attached to Thiobacillus denitrificans were used to construct the well-type reactive barrier comprising three discrete barriers installed at 1-m interval downstream. Average initial nitrate concentrations were 181 mg/L for the first 28 days and 281 mg/L for the next 14 days. For the 181 mg/L (2.9 mM) plume, nitrate concentrations decreased by ~2% (0.06 mM), ~9% (0.27 mM), and ~15% (0.44 mM) after $1^{st}$, $2^{nd}$, and $3^{rd}$ barriers, respectively. For the 281 mg/L (4.5 mM) plume, nitrate concentrations decreased by ~1% (0.02 mM), ~6% (0.27 mM), and ~8% (0.37 mM) after $1^{st}$, $2^{nd}$, and $3^{rd}$ barriers, respectively. Nitrate plume was flowed through the flow-tank for 49 days by supplying $1.24\;m^3/d$ of nitrate solution. During nitrate treatment, flow velocity (0.44 m/d), pH (6.7 to 8.3), and DO (0.9~2.8 mg/L) showed little variations. Incomplete destruction of nitrate plume was attributed to the lack of retention time, rarely transverse dispersion, and inhibiting the activity of denitrification enzymes caused by relatively high DO concentrations. For field applications, it should be considered increments of retention time, modification of well placements, and intrinsic DO concentration.

Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design (온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.204-211
    • /
    • 2019
  • The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to $16.3^{\circ}C$ and $14.6^{\circ}C$ during the experiment, respectively. The average water temperature in heating pipes was $52.3^{\circ}C$ and $45.0^{\circ}C$, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of $5.71{\sim}7.49W/m^2^{\circ}C$. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.

A Study on Characteristics of Drag Reduction Additive under High Temperature Range (고온영역에서 계면활성제의 마찰저감 성능 특성에 관한 연구)

  • Cho, Sung-Hwan;Ryu, Jae-Sung;Jung, Sang-Hoon
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • Overall total length of hydraulic pipe to transport the hot water in the domestic district heating network is above 3,000 Km approximately. This long pipe network requires a lots of the transport pumping power by surface friction of fluid. In this study, the drag reduction(DR) of Amin Oxide $C_{18}$ as non-ionic surfactant according to the fluid velocity, temperature and surfactant concentration under the condition of above $80^{\circ}C$ fluid temperature were investigated experimentally. Results showed that new amin oxide $C_{18}$ surfactant had DR of maximum 30% in fluid temperature of $80^{\circ}C$ and had 15% DR in fluid temperature over $100^{\circ}$ under short time test condition. And amine oxide had 155 hours duration time to keep the DR characteristic in the fluid temperature of $80^{\circ}$ and 1000 ppm concentration. But duration time of DR was decreased when fluid temperature increased.

Experimental Study on Coefficient of Flow Convection (유수대류계수에 관한 실험적 연구)

  • Jeon, Sang-Eun;Kim, Kook-Han;Kim, Jin-Keun;Yang, Joo-Kyoung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.314-322
    • /
    • 2003
  • Pipe cooling method is widely used for reduction of hydration heat and control of cracking in mass concrete structures. However, in order to effectively apply pipe cooling systems to concrete structures, the coefficient of flow convection relating the thermal transfer between inner stream of pipe and concrete must be estimated. In this study, a device measuring the coefficient of flow convection was developed. Since a variation of thermal distribution caused by pipe cooling has a direct effect on internal forced flows, the developed testing device is based on the internal forced flow concept. Influencing factors on the coefficient of flow convection are mainly flow velocity, pipe diameter and thickness, and pipe material. Using experimental results from the developed device, the coefficient of flow convection was calculated. Finally, a general prediction model was proposed by theoretical procedures. The proposed prediction model is able to estimate the coefficient of flow convection with flow velocity and material properties of pipe. From comparison with experimental results, the coefficient of flow convection by this model was well agreed with those by experimental results.

Gas Separations of Natural Zeolite by Chemical Treatments (화학처리에 의한 천연 Zeolite의 Gas 분리)

  • Im, Goeng
    • The Journal of Natural Sciences
    • /
    • v.5 no.1
    • /
    • pp.67-75
    • /
    • 1992
  • In the our country, especially in Yeongil and Wolsung area, abundant authigenic zeolites are found from the tuffaceous sediments and volcanic rocks of Miocene age showing wide variation in their mineralogy and abundance from horizon to horizon. The principal zeolite species identified are clinopti-lolite. mordenite. heulandite. ferrierite, and erionite. etc. Zeolite minerals are widely used in many countries in the following applications; (a) in air separation adsorption processes; (b)as desiccants; (c)in inorganic building materials; (d)in papermaking; (e)in fertilizers; (f)as soilconditioners-this application is based upon the ability of the zeolite to ion exchange with soil nutrients; (g)in the treatment of radioactive wastes; and (h)as adsorbents for toxic gases, etc. In the present paper, using natural zeolite mordenite treated with IN hydrochloric acid or IN sodium chloride solution as column packings, separation characteristics of argon, nitrogen, carbon monoxide, and methane gases have been studied by gas chromatography. By the use of mordenite treated with hydrochloric acid solution, the tailing peak of methane showed from untreated mordenite was satisfactorily reduced, although it was difficult to separate it from carbon monoxide with a column activated at $300^{\circ}C$. Using a column activated at $350^{\circ}C$, methane could be separated from carbon monoxide easily but only carbon monoxide eluted as a bad defined peak. Mordenite treated with sodium chloride solution was generally similar to chromatograms obtained by using the untreated mordenite. Both the above chemical treatments of mordenite had little effect on the separations of argon and nitrogen. The separations and the HETP values obtained from natural zeolite mordenite treated with continuously hydrochloric acid and sodium chloride solutions were almost identical with those obtained with synthetic molecular sieve 5A zeolite. On the other hand, the efficiency of column was good in the range 20~3Oml/min of the carrier helium gas rate.

  • PDF