• Title/Summary/Keyword: 표면 단열재

Search Result 43, Processing Time 0.028 seconds

공력가열 시험설비 설계

  • Ok, Ho-Nam;Kim, In-Sun;Ra, Seung-Ho;Kim, Seong-Lyong;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.155-169
    • /
    • 2004
  • Space launch vehicles and reentry vehicles are exposed to extreme heating conditions due to high aerodynamic heating while flying at high Mach numbers in the atmosphere. To protect the vehicle itself or the payload from the aerodynamic heating, the thermal load imposed on the surface should be exactly predicted and proper thermal protection should be applied based on the prediction results. But this requires rigorous thermal analysis and testing to prevent loss of payload capacity caused by excessive heat shielding, and the amount of thermal protection material to be applied is determined through aerodynamic heating tests. Various design points to be considered to upgrade the prototype aerodynamic thermal simulation facility(ATSF) used for the KSR-series sounding rocket development to the one suitable for the KSLV(Korean Space Launch Vehicle)-series launch vehicle are considered in this research. The need and limitation for the facility are first considered, and the functions required for KSLV testing are determined. The specifications of the upgraded facility are briefly suggested and these results will be used for the future fabrication and installation of the facility.

  • PDF

A Study on the Cone Calorimeter Evaluation Method of Sandwich Panels (복합자재 콘칼로리미터평가방법에 대한 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.74-82
    • /
    • 2017
  • Fires in buildings built using sandwich panels are difficult to extinguish, and the damage caused by the fire spreading through the inner core material is extensive. Sandwich panels consist of a nonflammable material on both sides of an insulation material. The types of insulation material include organic and inorganic insulation materials, but the former are used in more than 80% of the case. Organic insulation is economically advantageous compared to inorganic insulation, but it is vulnerable to fire. Therefore, the damage caused by sandwich panel fires is higher than that for general fires. In the case of the noxious gas analyzer test, the panel is tested with three round holes having a diameter of 25 mm, in order to determine the risk of the core material, but the cone calorimeter test is carried out using a sandwich panel. In this study, the cone calorimeter test was conducted to examine the fire risk of the composite material when heated on a nonflammable surface, exposed to the core material through a hole, and heated directly the core material. The type of organic insulation employed was flame retardant EPS (Expanded Polystyrene), and the test specimens were tested in three types of sandwich panel, a perforated sandwich panel and single core material. The purpose of this study is to propose a method of measuring the fire risk of the core materials of composite materials using the cone calorimeter test.

A thermal-flow analysis of deaerator floor of power plant for reducing the radiative heat transfer effect (발전소 Deaerator floor의 복사효과 저감을 위한 열유동 해석)

  • Kim, Tae-Kwon;Ha, Ji-Soo;Choi, Yong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.476-481
    • /
    • 2016
  • Steam power generation is used to produce electricity through a generator that is connected to a steam turbine. As a result, the surface temperature of the deaerator is $70^{\circ}C$during the summer season, the surface temperature of the storage tank is $67^{\circ}C$, and the air temperature is $50^{\circ}C$. This environment is inappropriate for workers and instruments. Workers adjacent to the deaerator and storage tank in particular feel higher temperatures because of the radiative heat transfer effect. Therefore, we optimized the cooling conditions by computational analysis. Case 1 is the current shape of the power plant, Case 2 has additional insulation, and Case 3 has a radiation shield. Flow is caused by a temperature difference between the heat sources in the wall, and hot air is trapped in the right upper end. Based on the temperature contours and the maximum temperature of the surfaces, Case 2 was found to be the most efficient for reducing radiative heat transfer effects.

Characterizations on the Thermal Insulation of SiC Coated Carbon-Carbon Composites (탄화규소로 코팅된 탄소-탄소 복합재료의 단열 특성)

  • Seo, Hyoung-IL;Lim, Byung-Joo;Sihn, Ihn Cheol;Bae, Soobin;Lee, Hyung-Ik;Choi, Kyoon;Lee, Kee Sung
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.101-107
    • /
    • 2020
  • This study investigates the characterization on the thermal insulation properties of silicon carbide coating on the Cf-C composites. The silicon carbide coatings by chemical vapor deposition on the C/C composites are prepared to evaluate thermal resistance. Firstly, we perform the basic insulation test by thermal shock at 1350℃ in air on the C/C composite and SiC-coated C/C composite. We also performed the burner tests on the surface of the composites at high temperatures such as 1700 and 2000℃, and the weight change after burner tests are measured. The damages on the surface of C/C composite and SiC-coated composite are observed. As a result, the SiC coating is beneficial to protect the C/C composite from high temperature even though damages such as defoliation, crack and voids are observed during burner test at 2000℃.

Development of Forms for Cold Weather Concrete by Combination of Insulation (단열재 조합에 의한 한중콘크리트용 거푸집 개발)

  • Han, Cheon-Goo;Oh, Seon-Kyo;Sin, Dong-An;Kim, Kyoung-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.392-399
    • /
    • 2003
  • This paper discusses the validities of insulating curing of cold weather concreting at early stage by applying insulation forms. Tests were carried out using modified insulating form combining existing insulating form and various other insulations in order to develop improved insulation form. Temperature history of concrete using various insulating forms and insulation was measured to determine most effective combination of insulting form. According to results, as for the wall form, under the curing temperature of $-10^{\circ}C$, the temperature of concrete using Euro form drops sharply before 24 hours and lasts below $0^{\circ}C$ for 7 hours. The temperature of concrete using the form combining Polypropylene panel, styrofoam and plywood panel keep above $0^{\circ}C$. And, it is confirmed that the form mentioned above has a favorable effects on enhancing strength development of concrete and the cost to make the forms shows more reasonable than that of existing forms. However, as for the combination methods of insulation form for slab, which is composed of insulating form at the bottom of slab and various surface curing materials at the top of slab, in case of exposed condition at the top of slab, temperature history of concrete goes below $0^{\circ}C$ after 10 hours. In case of the combination of vinyl sheet and curing blanket, it drops below $0^{\circ}C$ after 42 hours. However, in case of the combination of vinyl, styrofoam and curing blanket, it does not go below $0^{\circ}C$ until 55 hours. Accordingly, compared to the case of exposure and the combination of vinyl and curing blanket, it indicates that the combination mentioned above has more effective insulating performance.

Surface Temperature Control of an Insulated Horizontal Pipe under Thermal Radiation Environment (복사효과를 포함하는 수평관 표면의 온도제어)

  • Kang, Byung-Ha;Pi, Chang-Hun;Kim, Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.54-60
    • /
    • 2011
  • Procedures for estimation of insulation thickness for a horizontal pipe for condensation control or personnel protection has been investigated, parallel to the previous work of a vertical wall case. Parameters include pipe diameter, emissivity, thermal conductivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation, specially for the case of high temperature application with low Bi. The effect of surface radiation in such case could be up to 65% of the total. Required insulation thickness for the surface temperature control increases as pipe diameter increases and as surface emissivity decreases. Adequate revision of specifications or standards to include newly invented insulation materials with high emissivity has been also suggested.

Effect of Glass Fiber-Reinforced Polymer (GFRP) Shear Connector's Shape on Inplane Shear Strength of Insulated Concrete Sandwich Panels (유리섬유복합체를 사용한 전단연결재 형상에 따른 중단열 벽체의 면내전단내력)

  • Jang, Seok-Joon;You, Young-Chan;Kim, Ho-Ryong;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.9-17
    • /
    • 2013
  • This paper describes an experimental program to investigate the shear behavior of insulated concrete sandwich panels (CSPs) with different types of GFRP shear connector. The study included testing of 13 insulated CSP specimens with two types of surface conditions for extruded polystyrene (XPS) insulation and various shapes of shear connectors. All specimens were loaded in direct shear by means of push-out and were consist of three concrete panels, two insulation layer and four rows of GFRP shear connectors. Load-relative slip between concrete panel and insulation response of CSP specimens has been established through push-out shear test. Test results indicate that the surface condition of insulation has a significant effect on the bond strength between concrete panel and insulation. The specimen used XPS foam with 10mm deep slot shows higher bond strength than those used XPS foam with meshed surface. Corrugated GFRP shear connectors show equivalent strength to grid GFRP shear connectors. Cross-sectional area and embedded length of shear connector have a notable effect on overall response and inplane shear strength of the CSP specimens.

A Computer Programme Development for Thermal-Hydraulic Analysis and Optimal Design on LNG Pipeline System (LMG 배관시스템의 열유동 해석 및 최적설계 프로그램 개발)

  • Lee Sanggyu;Hong Seong-Ho;Lee Joong-Nam;Park Seok-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.2 s.10
    • /
    • pp.7-14
    • /
    • 2000
  • LNG (Liquified Natural Gas) carried by LNG ship is unloaded into the LNG storage tanks at the very low temperature (a little lower than the boiling point of LNG). Because LNG is unloaded through the pipeline, two phase flow appears in the pipeline. In this study, we have studied the pressure-drop mechanisms of the two-phase flow in the pipeline, and the calculation method of BOG (Boil-off Gas) amount based on the heat transfer mechanism through the insulation and the surface of the pipeline. We have developed a computer program for thermal-hydraulic analysis on the LNG pipeline system. We have also developed the optimal design program to find the optimal thickness of insulation and the pipeline size. The program searches the optimal design with the minimum capital cost of pipelines and insulation on the operating conditions of maximum allowance pressure-drop and BOG amount, etc.

  • PDF

Characterization of Insulation Finish Material Using Inorganic Wet Treatment Fly Ash (무기성 습식 처리 플라이애시를 활용한 단열 외피 마감재의 특성 평가)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Young;Kim, Deuak-Mo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.389-394
    • /
    • 2019
  • In this study, a functional inorganic insulation as TiO2 and inorganic wet fly ash were used to evaluate the physical performance and thermal environment of an exterior finish that can improve the thermal environment of a building. The performance evaluation of the finish was based on the KS F 4715 thin coating material and the thermal environment. When TiO2 was added, the physical performance was lowered at 10% or more, and the inorganic wet-treated fly ash increased the physical performance by 10%. In the thermal environmental evaluation, the surface temperature reduction effect of the inorganic wet-treated fly ash was low, but when used in combination with TiO2, it was effective to reduce the surface temperature and the internal temperature. As a result, the optimum combination of TiO2 and inorganic wet-treated fly ash for thermal environment control was found to be optimal when 5% of each mixture was used.