• Title/Summary/Keyword: 표면전위계

Search Result 40, Processing Time 0.026 seconds

Analysis of Surface Dose Refer to Distance between Beam Spoiler and Patient in Total Body Irradiation (전신방사선조사(Total Body Irradiation) 시 Beam Spoiler와 환자 간의 거리에 관한 고찰)

  • Choi, Jong-Hwan;Kim, Jong-Sik;Choi, Ji-Min;Shin, Eun-Hyuk;Song, Ki-Won;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.51-54
    • /
    • 2007
  • Purpose: Total body irradiation is used to kill the total malignant cell and for immunosuppression component of preparatory regimens for bone-marrow restitution of patients. Beam spoiler is used to increase the dose to the superficial tissues. This paper finds the property of the distance between beam spoiler and patient. Materials and Methods: Set-up conditions are 6 MV-Xray, 300 MU, SAD = 400 cm, field size = $40{\times}40cm^2$. The parallel plate chamber located in surface, midpoint and exit of solid water phantom. The surface dose is measured while the distance between beam spoiler and patient is altered. Because it should be found proper distance. The solid water phantom is fixer and beam spoiler is moving. Results: Central dose of phantom is 10.7 cGy and exit dose is 6.7 cGy. In case of distance of 50 cm to 60 cm between beam spoiler and solid water phantom, incidence dose is $14.58{\sim}14.92cGy$. Therefore, The surface dose was measured $99.4{\sim}101%$ with got near most to the prescription dose. Conclusion: In clinical case, distance between beam spoiler and patient affect surface dose. If once $50{\sim}60cm$ of distance between beam spoiler and patient, surface dose of patient got near prescription dose. It would be taken distance between beam spoiler and patient into account in clinical therapy.

  • PDF

The Study on the Corrosion Property of the Zn/Mg/Zn Multilayer Coatings with Various Mg layer thicknesses (Mg 중간층 두께에 따른 Zn/Mg/Zn 다층 박막의 내식특성에 관한 연구)

  • Bae, Gi-Tae;Ra, Jeong-Hyeon;Lee, Sang-Yul
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.177-177
    • /
    • 2016
  • 우수한 내식성을 가지는 Zn 박막은 자동차, 가전제품, 전자제품 등에 사용되는 철 생산품의 수명 연장을 위하여 널리 사용되어 왔다. 최근 개발된 Zn-Mg 합금 박막은 Zn나 Mg에 비해 우수한 내식성을 나타내는 Zn-Mg 합금상을 형성하기 때문에 순수한 Zn 박막이나 다른 Zn 계 합금 박막에 비해 우수한 내식성을 가진다고 보고된 바 있다. 본 연구에서는 다양한 합금상의 형성을 위해 Mg 중간층 두께를 제어하며 Zn/Mg/Zn 다층 박막들을 합성하였으며 열처리를 통한 합금상의 변화, 그에 따른 박막의 내식성에 관해 연구하였다. Zn/Mg/Zn 다층 박막은 총 $4{\mu}m$의 두께로 Mg 중간층의 두께를 변화하였으며 비대칭 마그네트론 스퍼터링 공정을 이용하여 냉연강판 위에 합성하였다. 합성된 다층 박막은 다양한 Zn-Mg 합금상을 형성하기 위하여 진공로를 이용하여 $200^{\circ}C$에서 1시간 동안 어닐링 열처리를 실시하였다. 열처리 전, 후 Zn/Mg/Zn 다층 박막의 미세조직과 조성은 X선 회절 분석기 (XRD)와 전계방출형 주사전자현미경 (FE-SEM)과 글로우 방전 분광분석기 (GDEOES)를 사용하여 분석하였다. 어닐링 열처리를 통한 Zn-Mg 합금상 형성이 Zn/Mg/Zn 다층 박막의 내식성에 미치는 영향을 평가하기 위하여 동전위 분극시험과 EIS(Electrochemical impedance spectroscopy) 분석 실시하였다. FE-SEM과 GDOES 분석 결과, Zn/Mg/Zn 다층 박막들 각각의 중간층 Mg 두께는 1.5, 2.0, $2.5{\mu}m$ 였으며, 어닐링 열처리 후 중간층의 Mg이 상, 하부의 Zn 층으로 확산되면서 박막을 치밀한 구조로 변화시키는 것으로 확인되었다. XRD 분석 결과, 열처리를 하지 않은 Zn/Mg/Zn 다층 박막들에서는 Mg 상의 피크의 강도 차이만 존재할 뿐 Zn-Mg 합금상은 형성되지 않았다. 그러나 열처리를 후 Zn/Mg/Zn 다층 박막들에서 $MgZn_2$ 합금상이 형성되었으며, 중간층 Mg 두께가 $1.5{\mu}m$ 이하인 박막에서는 Zn 상이, 초과하는 박막에서는 Mg 상이 잔존하는 것을 확인하였다. EIS 분석 결과, 열처리 후 박막의 전하이동저항 값은 증가하며 박막의 어드미턴스 값이 감소하였으며 Bode phase plot을 통해 열처리 후 시정수(time constant)가 높은 주파수 영역에서 형성 되는 것을 확인하였다. 이는 열처리 후 Zn/Mg/Zn 다층 박막이 치밀해지고 내식성이 향상되었음을 나타낸다. 동전위 분극시험 결과에서도 마찬가지로 열처리 한 Zn/Mg/Zn 다층 박막들은 열처리 전 대비 내식성이 향상되는 것을 확인하였다. 열처리를 통한 Zn/Mg/Zn 다층 박막의 내식성의 향상은 우수한 내식성의 합금상의 형성과 박막 미세구조의 치밀화에 기인한다고 판단하였다. 또한 열처리 한 Zn/Mg/Zn 다층 박막들에서는 Zn와 $MgZn_2$ 상들이 공존 할 경우 가장 우수한 내식성을 나타내었으며, 이는 $MgZn_2$와 Zn 사이의 적은 전위 차이로 인해 갈바닉 부식 효과가 감소되었기 때문으로 판단된다.

  • PDF

pH Solubility Properties and Improved Dissolution of Pranlukast as an Poorly Water-soluble Model Drug Prepared by Spray-drying with Plasdone S-630 (플라스돈 S-630과 함께 분무건조된 모델 난용성 약물로서 프란루카스트의 pH 용해도 특성 및 용출률 개선)

  • Cho, Won-Hyung;Lee, Young-Hyun;Song, Byung-Joo;Yoo, Seok-Cheol;Lim, Dong-Kyun;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.35 no.4
    • /
    • pp.277-283
    • /
    • 2011
  • Solid dispersion is mainly used for improved dissolution of poorly water-soluble drugs. Solid dispersion of pranlukast was prepared by spray-drying with plasdone S-630. When pH of water was high, pranlukast was highly soluble in the solubility experiment of solid dispersions with varying pH. The particle size of pranlukast particles in solid dispersions was measured to be in nanometers scale based on particle size analysis. Zeta-potential analysis confirmed the negative charge of solid dispersion. SEM was used to observe the surface of solid dispersion, which confirmed spherical morphology, DSC and XRD confirmed the amorphous nature of solid dispersions. The in vitro test was carried out to find improved dissolution rate of pranlukast solid dispersion in simulated juice gastric and a controlled experiment was carried out to compare pranlukast solid dispersions with a conventional drug (Onon$^{(R)}$), These results showed the dissolution properties of pranlukast solid dispersions prepared by spray drying proper for the oral pharmaceutical formulation.

Flocculation Kinetics Using Fe(III) Coagulant in Advanced Water Treatment: The Effect of Sulfate Ion (상수처리시 Fe(III) 응집제를 이용한 응집동력학에 관한 연구 : 황산이온의 영향)

  • 강임석;이병헌
    • Journal of Environmental Science International
    • /
    • v.4 no.4
    • /
    • pp.367-377
    • /
    • 1995
  • The study of flocculation kinetics is of fundamental interest in the field of water treatment, because rational study of the factors affecting the coagulation process should be based on the rate of particle growth. The effect of sulfate on flocculation kinetics were examined using ferric nitrate as a coagulant to coagulate kaolin clay in water under several experimental conditions. Both the particle size distribution data obtained from the AIA and the on-line measurement of turbidity fluctuation by the PDA were used to measure flocculation kinetics. Results show that sulfate ion added to the kaolin suspension played an important role in the flocculation process, not only improving flocculation kinetics at more acidic pH levels but also changing surface charge of particles. The kinetics of flocculation were improved mainly by the enhanced rate and extent of Fe(III) precipitation attributed to the addition of sulfate, and thereby, better interparticle collision frequency, but little by the charge reductions resulting from the sulfate addition. The increase in sulfate concentration beyond $3\times10^{-4}M (up to 2\times10^{-3}M)$ did not induce further improvement in flocculation kinetics, although the higher concentrations of sulfate ion substantially increased the negative ZP value of particles. Key Words : Flocculation Kinetics, Fe(III) Coagulant, Sulfate ion, Turbidity Fluctuation.

  • PDF

Comparison of growth and properties of GaN with various AlN buffer layers on Si (111) substrate (Si (111) 기판 위에 다양한 AIN 완충층을 이용한 GaN 성장과 특성 비교)

  • 신희연;이정욱;정성훈;유지범;양철웅
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.1
    • /
    • pp.50-58
    • /
    • 2002
  • The growth of GaN films on Si substrate has many advantages in that Si is less expensive than sapphire substrate and that integration of GaN-based devices with Si substrate is easier The difference of lattice constant and thermal expansion coefficient between GaN and Si is larger than those between GaN and sapphire. However, which results in many defects into the grown GaN. In order to obtain high duality GaN films on Si substrate, we need to reduce defects using the buffer layer such as AlN. In this study, we prepared three types of AlN buffer layer with various crystallinity on Si (111) substrate using MOCVD, Sputtering and MOMBE methods. GaN was grown by MOCVD on three types of AlN/Si substrate. Using TEM and XRD, we carried out comparative investigation of growth and properties of GaN deposited on the various AlN buffers by characterizing lattice coherency, crystallinity, growth orientation and defects formed (voids, stacking faults, dislocations, etc). It is found that the crystallinity of AlN buffer layer has strong effects on growth of GaN. The AlN buffer layers grown by MOCVD and MOMBE showed the reduction of out-of-plane misorientation of GaN at the initial growth stage.

An Experimental Study on the Restoration Creation of Tidal Flats (간석지 생태계 복원에 관한 실험적 연구)

  • Lee, Jeoung-gyu;Lee, Nam-hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.1
    • /
    • pp.77-82
    • /
    • 2000
  • Seven constructed and three natural tidal flats were compared to evaluate state-of- the-art of creation and restoration technology for tidal flats. parameters studied were physico-chemical and biological characteristics of soils and rate of respiration. The natural tidal flats had higher contents of silts, nitrogen and organic matter compared to the constructed ones. The natural ones had reductive Bone below 2 cm whereas the constructed ones had oxidative zone from the surface to below 20 cm. The bacterial population in the soil of the constructed tidal flats was one to two magnitudes lower than that in the natural ones. Biomass of macrobenthos and microbial respiration rate, however, were not different significantly between the natural and the constructed tidal flats. The purification capacity by diatom+bacterial+meiobenthos and macrobenthos in the constructed tidal flats was higher than that in the natural ones due to deeper permeable layer for purification in the constructed tidal flats. There was an exceptional constructed tidal flat with similar physico-chemical and biological characteristics to natural ones. Shearing stress to the surface of the tidal flat by the flow of seawater was as low as that of natural ones. These hydraulic conditions seemed to be a controlling factor on structures and functions of tidal flats. The control of hydraulic condition seemed to be one of the most important factors to create natural-like tidal flats.

  • PDF

Performance Evaluation of Stirrers for Preventing Dendrite Growth on Liquid Cathode (액체음극에서의 금속 수지상 성장 억제를 위한 교반기 성능평가)

  • Kim, Si-Hyung;Yoon, Dal-Seong;You, Young-Jae;Paek, Seung-Woo;Shim, Joon-Bo;Ahn, Do-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.2
    • /
    • pp.125-131
    • /
    • 2009
  • An electrolytic system (zinc anode-gallium cathode) was setup to evaluate the performance of several stirrers prepared for this study, where stirrers have been used to prevent uranium from forming dendrite on the cathode in pyrochemical process. In the case of no-stirring condition, zinc dendrites began to grow on the gallium surface in 1 hour and some dendrite grew out of the cathode crucible around 6 hours. When a rectangular stirrer or a tilt stirrer was rotated, at 40${\sim}$150 rpm, to mix the liquid gallium cathode, dendritic growth of zinc metal was prevented irrespective of revolution speed, but some of the deposits overflowed out of the cathode crucible owing to the large centrifugal forces at 150 rpm. The harrow stirrer did not nearly retard the dendrite growth at 40 rpm, but the dendrite growth was retarded at higher than 100 rpm and the zinc deposits also did not overflow at 150 rpm. Pounder could also prevent the dendrite growth to some extent but it had some difficulties in operation compared with other types of stirrers.

  • PDF

Oxidative Coupling Reaction of Chlorophenols by Natural Manganese Dioxides (천연망간산화물을 이용한 클로로페놀류의 산화중합반응)

  • Jeon Sun-Young;Ko Seok-Oh
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.62-69
    • /
    • 2005
  • Removal of 4-chlorophenol (4CP) by natural manganese dioxide (NMD) catalyzed reaction was investigated in this study. Tests were also carried out to evaluate the effects of pH and natural organic matter (NOM) on the degradative oxidation of 4CP. Experimental results proved that NMD was effective for the removal of 4CP. Extensive kinetic analysis suggests that overall oxidation of 4CP by NMD is second-order reaction, the first-order with respect to 4CP, and the first-order with respect to NMD, respectively. Also, 4CP oxidation rates on the Mn-oxide surfaces were highly dependent upon experimental conditions such as pH, initial concentration of 4CP or NMD, and existence of humic acid. As pH increased above PZC of NMD, the reaction rate of 4CP was decreased, due to the low affinity of 4CP on NMD at high pH. At pH lower than PZC of NMD, reaction rate of 4CP was also decreased. It was considered that humic acid was involved in the oxidative coupling reaction of 4CP by NMD, resulting in the enhanced degradation rate of 4CP. This study proved that natural manganese oxide can be effectively applied for the removal of chlorophenols in aqueous phase.

Evaluation of the Removal Characteristics of Pollutants in Storm Runoff Depending on the Media Properties (여재 특성에 따른 강우 유출수 내 오염물질 제거특성 평가)

  • Kim, Tae-Gyun;Cho, Kang-Woo;Song, Kyung-Guen;Yoon, Min-Hyuk;Ahn, Kyu-Hong;Hong, Sung-Kwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.483-490
    • /
    • 2009
  • The aims of this study were to evaluate the removal efficiency for various pollutants in urban storm runoff by a filtration device, and to determine design parameters depending on filter media properties. Appropriate selection of filter media will affect the size and life time of the filtration device. Sets of column tests were performed in order to evaluate the removal efficiency by perlite and a synthetic resin. An investigation of surface properties including CEC (cation exchange capacity) and zeta-potential suggested that the perlite had a superior adsorption capability for cationic pollutants. TCODcr and turbidity were analyzed to investigate the removal characteristic of particulate pollutant. In both columns, the particles in the collected storm runoff was almost completely capture with a small EBCT (empty bed contact time) of 2.5 minutes. Complete clogging at the EBCT of 2.5 minutes occurred after 630 minutes in the perlite column and 810 minutes in the resin column. The removal efficiency of TCODcr and turbidity at the EBCT of 2.5 minutes decreased to below 70% due to an wall effect. The removal efficiency for dissolved pollutant (SCODcr) was negligible due to the insufficient contact time for adsorption. The removal of heavy metals (Cu, Zn, Pb) was mostly ascribed to the filtration of particles containing metals, since the relationship between CEC and the removal efficiency was not apparent. The result of this study would be valuable for the application of filtration device to control of urban storm runoff.

The Study on Properties and Application of Enhanced Dynamic Wedge Factor (향상된 동적쐐기인자(Enhanced Dynamic Wedge Factor)의 특성 및 적용에 관한 고찰)

  • Kim, Dae-Sup;Ban, Tae-Joon;Yeom, Mi-Suk;Yoo, Soon-Mi;Lee, Woo-Seok;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • Purpose: We try to calculate EDW-factor easily with the formula applies essential data of EDW-factor and evaluate the validity through a measurement. Materials and Methods: We used the given value of GSTT (Golden Segmented Treatment Table) for the calculation of the EDW-factor. As to the experimental device, 0.6 cc farmer-type ion-chamber, an electrometer and water- phantom were used. A measurement was made at the maximum dose depth of the photon beam energy 6 MV and 15 MV under the condition that SSD (Source to Surface Distance) was 100 cm. The angle of the EDW (Enhanced Dynamic Wedge) which we use in an experiment was 60 degree, 30 degree, 20 degree in the Y1-OUT direction. We used Eclipse planning system (Varian, USA) as RTP system and the EDW-factor was calculated about all fields and EDW direction. In order to show the EDW-factor feature, a measurement was made at the selected field that verify the influence of the dependability about X, Y jaw and off-axis field. Results: When we change the Y1 field, it influence on the EDW-Factor and measured value. But the error between measured values and calculated values was less than 1%. The experimental result indicated the tendency that the error of the result of calculation and measured value becomes smaller as the EDW angle become smaller whether the calculation point (measurement point) and iso-center are same or not. The influence of the field size and energy did not show up. We simulated with the same condition using the RTP system. And we found that it makes no difference between the MU which is calculated manually by applying the EDW-Factor obtained from the commercial program and the value which is calculated by using RTP system. Conclusion: We excluded fitting value from well-known EDW-Factor formula and calculated EDW-factor with the formula applies essential data of EDW-factor only. As a result, there are no significant difference between the measured value and calculated value and it showed errors less than 1%. Also, we implemented the commercial program to calculate EDW-Factor conveniently without measure a factor on each field.

  • PDF