• Title/Summary/Keyword: 표면습도

Search Result 236, Processing Time 0.026 seconds

Effects of Humidity and Velocity on Frost Distribution Characteristics of Humid Air Flow on Cold Surfaces (차가운 표면위에서의 습공기 유동의 습도 및 속도가 착상분포 특성에 미치는 영향)

  • Kwon Jeong-Tae;Rew Keun-Ho;Lim Hyo-Jae;Han Ji-Won;Kwon Young Chul
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.213-218
    • /
    • 2005
  • In order to understand the heat and mass transfer characteristics of humid airflow in frosting conditions, a flat plate of aluminum with cooling modules located in the central part of the plate was used. A microscope system (resolution of 0.05 mm) was used for the measurement of local thickness of frost at seven points along the plate in the flow direction. For the total mass of frost at each test operation, an electronic balance (resolution of 1 mg) was used. The local frost thickness distributions far various test conditions were presented along with the frost mass data measured at the given operating times. The effect of humidity and velocity of humid air on frosting were analyzed.

Damage of Overlaid Concrete Structures Subjected to Humidity Changes in the Atmosphere (습도 변화에 따른 콘크리트 덧씌우기 보수체의 손상분석)

  • 윤우현
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.766-773
    • /
    • 2002
  • The failure phenomenon of overlaid concrete structures, such as surface crack, and peel-off failure, shear bond failure in the end contact zone, was investigated due to humidity changes. To investigate this failure phenomenon, the surface tensile stress, and the shear stress, the vertical tensile stress in the contact zone were analysed using the non-linear stress-strain relationship of material such as strain-hardening- and strain-softening diagrams. Overlay thickness and overlay material were the main variables in the analyses. It is assumed that the initial surface humidity of overlaid concrete structures was 100% r.H. With a atmospheric humidity of 55% r.H. and two load cases for drying(LCI), curing and drying(LC2), the stress states of overlaid concrete structures were calculated. The result shows that only fictitious cracks occurred in the overlay surface of CM2O, ECM25, and no shear bond failure occurred in the contact zone without CM2O. The peel-off failure was proved to be the main cause of the damage in the overlaid concrete structures. Only for overlay thickness of 1cm occurred no peel-off failure in the case of drying after a long-term public use(LC1). In the case of curing and drying during overlay work(LC2) occurred the peel-off failure within 1.5days for all the overlaid concrete structures.

Autogenous Shrinkage of High-Performance Concrete Containing Mineral Admixture (광물질 혼화재를 함유한 고성능 콘크리트의 자기수축)

  • Lee, Chang-Soo;Park, Jong-Hyok;Kim, Yong-Hyok;Kim, Young-Ook
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.3
    • /
    • pp.19-31
    • /
    • 2007
  • Humidity and strain were estimated for understanding the relation between humidity change by self-desiccation and shrinkage in high-performance concrete with low water binder ratio and containing fly ash and blast furnace slag. Internal humidity change and shrinkage strain were about 10%, 10%, 7%, 11%, 11% and $320{\times}10^{-6}$, $270{\times}10^{-6}$, $231{\times}10^{-6}$, $371{\times}10^{-6}$, $350{\times}10^{-6}$ respectively on OPC30, O30F10, O30F20, O30G40, O30G50 and from the results, fly ash made humidity change and strain decrease but slag increase comparing with ordinary portland cement. Considering only relation internal humidity and shrinkage by self-desiccation, humidity change and shrinkage represented the strong linear relation regardless of mineral admixture. For specifying the relation on internal humidity change and autogenous shrinkage strain, shrinkage model was established which is driven by capillary pressure in pore water and surface energy in hydrates on the assumption of a single network and extended meniscus in pore system of concrete. This model and experimental results had a similar tendency so it would be concluded that the internal humidity change by self-desiccation in HPC originated in small pores less than 20nm, therefore controlling plan on autogenous shrinkage might be focused on surface tension of water and degree of saturation in small pore.

Humidity Effects on Electric Property in ${\gamma}$-Ray Irradiated PE and PP (방사선이 조사된 PE와 PP의 전기적 특성에 미치는 습도효과)

  • Kang, J.H.;Kim, H.J.;Yu, K.M.;Han, S.O.;Kim, J.S.;Park, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1458-1459
    • /
    • 2002
  • PE(Polyethylene)와 PP(Polypropylene)의 sheet 에 $Co^{60}{\gamma}$-ray 선원을 실온, 대기 중에서 10 kGy, 30 kGy, 50 kGy의 방사선량으로 조사시키고 습도 분포에 따른 표면 및 체적 저항을 측정한 결과 방사선이 조사되지 않은 시료와 방사선이 조사된 시료와의 저항 값은 큰 차이를 보이지 않았으나 습도 효과에 따른 변화는 습도 분포가 높을수록 저항 값은 상대적으로 낮게 나타났다.

  • PDF

Survival of Bacillus cereus and Its Transfer from Agricultural Product-Contact Surfaces to Lettuce (Bacillus cereus의 농산물 접촉 표면 재질별 생존력 및 상추로의 교차오염도 조사)

  • Kim, Se-Ri;Seo, Min-Kyoung;Kim, Won-Il;Ryu, Kyoung Yul;Kim, Byung-Seok;Ryu, Jae-Gee;Kim, Hwang-Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.253-259
    • /
    • 2014
  • This study was conducted to investigate survival of Bacillus cereus (B. cereus) on stainless steel and polyvinyl chloride (PVC) and its transfer from two material to lettuce. The stainless steel and PVC were innoculated with B. cereus and stored at 6 combination conditions (temperature : $20^{\circ}C$ and $30^{\circ}C$, relative humidity (RH) : 43%, 69%, and 100%). Although the total numbers of B. cereus at RH 43% and RH 69% were reduced by 3.53-4.00 log CFU/coupon within 24 h regardless of material type, the spore numbers of B. cereus was lasted at 3.0 log CFU/coupon. When two materials were stored at $30^{\circ}C$, RH 100%, the spore numbers of B. cereus was rapidly increased by 3.0 log CFU/coupon. In addition, the reduction rate of B. cereus was decreased in the presence of organic matter. Transfer rate of B. cereus from surface of stainless steel and PVC to lettuce was increased by 10 times in the presence of water on the lettuce surface. As a result of this study, the presence of B. cereus on produce contact surfaces can increase the risk of cross-contamination. Thus, it is important that the packing table and conveyer belt in post harvest facility should be properly washed and sanitized after working to prevent cross-contamination.

Gelatin Film Coated Fiber-Optic Directional Coupler-Based Humidity Sensors (젤라틴 코팅을 이용한 광섬유형 방향성 결합기 기반 습도 센서)

  • Son, Gyeongho;Kim, Minchul;Yu, Kyoungsik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.11
    • /
    • pp.865-871
    • /
    • 2017
  • In this paper, a gelatin layer was formed on the surface of the twisted fiber-optic couplers fabricated by hydrofluoric acid, which can be used to measure relative humidity. The proposed method of sensors has advantage of low cost compared with the sensors based on the conventional electronic devices and takes beneficial characteristics of optical fibers and light. The fiber-optic sensors presented in this study show a measurement from about 40% to 85% relative humidity, and the experimental results agree well with the calculated results. Based on the design presented in this paper, the structure will enable promising applications in the detecting humidity and various hazardous gases.

Experimental Investigation on Variation of Internal Relative Humidity and Temperature due to Hydration of Concrete at Early Age (내부 온습도 측정을 통한 초기재령의 콘크리트 내부 습도 및 수화열 변화 특성 분석)

  • Hong, Sung-Ki;Park, Cheol-Woo;Park, Sung-Jae;Kang, Tae-Sung;Kim, Hee-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.741-744
    • /
    • 2008
  • Quality control of early age concrete significantly influences the long term performance. Primary factors for early age concrete quality control should include the relative humidity and temperature variation, and these are more important as structures become massive and huge. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

Wet surface performance test of fin-tube heat exchangers with slit-wavy fin (물결형 슬릿핀이 장착된 핀-관 열교환기의 습표면 성능 실험)

  • Kim, N.H.;Kim, J.S.;Cho, J.P.;Yun, J.H.;Peck, J.H.;Lee, S.G.;Nam, S.B.;Kwon, H.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.153-162
    • /
    • 1997
  • In this study, the wet surface heat transfer coefficients and friction factors of the heat exchanger with slit-wavy fin were measured. Four sample cores of two or three row with fins of 12 fpi or 16 fpi were tested. Tests were conducted in a closed loop wind tunnel, where the heat exchanger was mounted at 45 degree inclination angle. The wet surface heat transfer coefficient was reduced following the procedure given in ARI 420-81. During the course, new definitions of the $\varepsilon$-NTU applicable to enthalpy driving system were introduced. The wet surface heat transfer coefficients were approximately equal to the dry surface values. However, the friction factors were approximately 120% to 170% higher than those of the dry surface. Both the heat transfer coefficient and the friction factor of the wet surface increased as the relative humidity increased, fin pitch decreased, and the number of row decreased, although the difference was not large.

  • PDF