• Title/Summary/Keyword: 폴리에틸렌 마모 입자

Search Result 3, Processing Time 0.019 seconds

Effect of Mixing Process on the Wear Properties of UHMWPE/Kaolin Composite (입자충전 초고분자량 폴리에틸렌의 마모특성 : 입자충전 방법의 효과)

  • Ki, Nam;Lee, Geon-Woong;Yoon, Ho-Gyu;Park, Hong-Jo;Kwak, Soon-Jong;Kim, Jun-Kyung;Park, Min
    • Polymer(Korea)
    • /
    • v.26 no.6
    • /
    • pp.803-811
    • /
    • 2002
  • In this study the wear behavior of ultra high molecular polyethylene (UHMWPE) filled with kaolin particles by different methods was investigated. UHMWPE/kaolin composites were prepared by two different methods: polymerization-filling and powder mixing. Particularly in a powder mixing method. Particle dispersion and wear property according to powder mining method were examined. It was found from wear test that filling of inorganic filler into UHMWPE by polymerization filling was more effective way than by powder mixing method in improving Wear resistance of UHMWPE. It was also confirmed that abrasive wear was dominant wear mechanism and particle dispersion in the composite as well as interface property was an important factor in controlling the wear behavior of the resulting composites.

Wear and Implantation Tilt Measurements using X-ray and CAD (X-ray영상과 CAD를 이용한 인공고관절의 마모 및 식립각 측정법)

  • Lee, Jong Min;Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2018
  • Long-term complications such as loosening, wear, osteolytic lesion and granulomatous reaction by foreign bodies can occur, after total hip arthroplasty. The implantation alignment effects dislocation and wear, according to its amount and direction. Wear particles in total hip arthroplasty brings about biochemical complications such as osteolysis or send wear. In this sense, it is important to regularly check wear and alignment of total hip replacement. Because the wear in followup of 10 years may remain in a small amount, like a 1 or 2 mm generally, somewhat precise measurement tool has to be established. The wear and alignment measurement softwares commercially available currently lack in project saving or reproducibility. This study suggests a reliable method for the measurement using an X-ray image and a CAD software. The proposed method can be executed only if having a CAD software under most of current general clinical radiographical environment. The proposed was revealed through tests for the method to have accuracy of 0.06 mm with precision of 0.05 mm for wear measurement, and precision of 0.27 degrees for tilt measurement.

Finite Element Analysis for the Contact Stress of Ultra-high Molecular Weight Polyethylene in Total Knee Arthroplasty (전 슬관절 치환 성형술에 사용되는 초고분자량 폴리에틸렌 삽입물의 접촉응력에 관한 유한요소해석)

  • Jo, Cheol-Hyeong;Choe, Jae-Bong;Choe, Gwi-Won;Yun, Gang-Seop;Gang, Seung-Baek
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 1999
  • Because of bone resorption, wear of ultra-high molecular weight polyethylene(UHMWPE) in total knee arthroplasty has been recognized as a major factor in long-term failure of knee implant. The surface damage and the following harmful wear debris of UHMWPE is largely related to contact stress. Most of the previous studies focused on the contact condition only at the articulating surface of UHMWPE. Recently, contact stress at the metal-backing interface has been implicated as one of major factors in UHMWPE wear. Therefore, the purpose of the is study is to investigate the effect of the contact stress for different thickness, conformity friction coefficient, and flexion degree of the UHMWPE component in total knee system, considering the contact conditions at both interfaces. In this study, a two-dimensional non-linear plane strain finite element model was developed. The results showed that the maximum value of von-Mises stress occurred below the articulating surface and the contact stress was lower for the more conforming models. All-polyethylene component showed lower stress distribution than the metal-backed component. With increased friction coefficient on the tibiofemoral contact surface, the maximum shear stress increased about twofold.

  • PDF