• Title/Summary/Keyword: 폭발압력

Search Result 332, Processing Time 0.023 seconds

Blast Analysis of Concrete Structure using Arbitrary Lagrangian-Eulerian Technique (Arbitrary Lagrangian-Eulerian기법을 적용한 콘크리트 구조물의 폭발해석)

  • Yi, Na-Hyun;Kim, Sung-Bae;Nam, Jin-Won;Lee, Sung-Tae;Kim, Jang-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.269-272
    • /
    • 2008
  • Blast load, an impulsive load with extremely short time duration with very high pressure, is effected by ground and air condition, weight of charge, shape and location of structure. In this study, a blast dynamic analysis for the air-structural integrated model considering dynamic properties of materials and simulation of complex blast wave propagation by Arbitrary Lagrangian- Eulerian technique is suggested to perform an accurate blast analysis of concrete structures. For the verification of the proposed blast analysis method, which is the air-structure integrated model using ALE technique, the comparison of analysis and experimental results is performed. The verification confirms that the simulation of realistic behavior of RC wall structures is possible using ALE method. Also, the example cases which have been analyzed using this method show that the estimation to the structural failure criterion for blast load failure can be represented by energy absorbtion procedure.

  • PDF

Finite Element Analysis of Contact Pressure Behavior in Compression Ring-Oil Film (압축링-유막간의 접촉압력 거동에 관한 유한요소해석)

  • 김한구;김청균;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1995.06b
    • /
    • pp.48-53
    • /
    • 1995
  • 본 연구에서는 윤활유막의 접촉압력 거동문제를 다른 각도에서 유한요소기법으로 해석하고자 한다. 즉, 혼합기가 폭발하게 되면 피스톤과 실린더 사이의 윤활유막이 순간적으로 초고압을 받아서 윤활유막은 밀폐된 공간에서 마치 폴리머처럼 거동할 것이라고 가정할 수 있다. 이와 같은 현상은 극히 짧은 시간에 국부적으로 일어날 것으로 예상되며, 이러한 작동조건에서 피스톤 링의 접촉면 형상에 따른 피스톤 압축링-윤활유막 사이의 접촉압력 거동문제를 미시적일 측면에서 유한요소기법으로 피스톤의 동적문제를 해석하고자 한다.

  • PDF

A Case Study on the Blasting Analysis of Slope Using Monitored Vibration Waveform (실측진동파형을 이용한 비탈면 발파진동 해석 사례)

  • Park, Do-Hyun;Cho, Young-Gon;Jeon, Seok-Won
    • Explosives and Blasting
    • /
    • v.24 no.2
    • /
    • pp.41-50
    • /
    • 2006
  • Excavation by explosives blasting necessarily involves noise and vibration, which is highly prone to face claims on the environmental and structural aspects from the neighbors. When the blasting carried out in the vicinity of a structure, the effect of blasting vibration on the stability of the structure should be carefully evaluated. In the conventional method of evaluation, an equation for blast vibration is obtained from test blasting which is later used to determine the amount of charge. This method, however, has limitations in use since it does not consider topography and change in ground conditions. In order to overcome the limitations, dynamic numerical analysis is recently used in continuum or discontinuous models, where the topography and the ground conditions can be exactly implemented. In the numerical analysis for tunnels and rock slopes, it is very uncommon to simulate multi-hole blasting. A single-hole blasting pressure is estimated and the equivalent overall pressure at the excavation face is used. This approach based on an ideal case usually does not consider the ground conditions. And this consequently results in errors in calculation. In this presentation of a case study, a new approach of using blast waves obtained in the test blast is proposed. The approach was carried out in order to improve the accuracy in calculating blasting pressure. The stability of a structure in the vicinity of a slope blasting was examined using the newly proposed method.

An Evaluation of Blast Resistance Performance of RC Columns According to the Shape of Cross Section (단면의 형상에 따른 철근콘크리트 기둥의 폭발저항 성능 평가)

  • Kim, Han-Soo;Park, Jae-Pyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • The alternative load path method based on a column removal scenario has been commonly used to protect building structures from being progressively collapsed due to probable blast loading. However, this method yields highly conservative result when the columns still have substantial load resisting capacity after blast. In this study, the behavior of RC columns with rectangular and circular sections under the blast loading was investigated and the remaining capacity of the partially damaged columns was compared. AUTODYN which is a hydrocode for the analysis of the structure on the impact and blast loading was used for this study. The blast loading was verified with the experiment results. The analysis results showed that the circular columns are preferable to the rectangular ones in respect of the blast resistance performance.

Parametric Study on Reinforced Concrete Columns under Blast Load (주철근의 개수 및 단면비에 따른 폭발하중을 받는 철근콘크리트 기둥의 해석적 연구)

  • Choi, Hosoon;Kim, Min-Sook;Lee, Young-Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.3
    • /
    • pp.219-226
    • /
    • 2012
  • Columns are the key elements supporting load in structure. Column failure causes the structure to collapse. It is important to evaluate residual strength for damaged columns under blast load for preventing progressive collapse. In this paper, columns were investigated to compare the blast resistance on the change of the number of steel bars within the range of reinforcement ratio. And this study was carried out 4 different analytical models to evaluate effects of aspect ratio. The results indicate that the vertical strain was unaffected by the number of steel bars and aspect ratio. As the number of steel bars facing blast load increase, the blast resisting capacity of the columns was improved in the lateral strain. Also, the analysis results showed that a large moment of inertia of area, as compared to a small one would be superior in residual strength as well as force of restitution.

Blast Analysis and Damage Evaluation for Reinforced Concrete Building Structures (RC Building 구조물의 폭발해석 및 손상평가)

  • Park, Yang Heum;Yun, Sung-Hwan;Jang, Il Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.331-340
    • /
    • 2021
  • The blast damage behavior of reinforced concrete (RC) structures exposed to unexpected extreme loading was investigated. To enhance the accuracy of numerical simulation for blast loading on RC structures with seven blast points, the calculation of blast loads using the Euler-flux-corrected-transport method, the proposed Euler-Lagrange coupling method for fluid-structure interaction, and the concrete dynamic damage constitutive model including the strain rate-dependent strength and failure models was implemented in the ANSYS-AUTODYN solver. In the analysis results, in the case of 20 kg TNT, only the slab member at three blast points showed moderate and light damage. In the case of 100 kg TNT, the slab and girder members at three blast points showed moderate damage, while the slab member at two blast points showed severe damage.

Design of Integration Controller of Explosive Proof Panel (방폭 패널 통합 제어기 설계)

  • Bak, Gwi-Man;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.267-272
    • /
    • 2020
  • Currently, the petrochemical industry complex always has remained with the explosive riskiness due to explosive and inflammable gases. In order to prevent explosion, all kind of equipment or facility including controller and its panel requires explosive proof. The control panel, which is currently used as explosive proof, has been used as the air injection method by manually from outside to constantly keep the temperature and pressure between inside and outside of the panel. In this paper, we propose the design of integrated controller of explosive proof panel which can control pressure and temperature automatically.

A Study on the Explosion Characteristics of Hydrogen (수소의 폭발 특성에 관한 연구)

  • Oh, Kyu-hyung;Rhie, Kwang-won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.3
    • /
    • pp.228-234
    • /
    • 2004
  • It was discussed about explosion danger of hydrogen gas experimentally that could be happen during the handling and using. Hydrogen concentration was varied from 10 to 60 vol% for get the explosion characteristics of hydrogen and 5 kinds of cylindrical vessel were used to find the explosion characteristics of hydrogen according to the vessel volume. Initial pressure of hydrogen-air mixture was varied from 0.6 to 2 kg/cm2. Based on the experiment, explosion pressure was most high near the 30vol% of hydrogen and explosion pressure was increased slightly according to the increase of vessel volume but explosion pressure rise rate was decreased. Explosion pressure was increased linearly proportional to the initial pressure of gas mixture.

Blast Analysis for RC Structures using Cluster Parallel Algorithm (Cluster Parallel Algorithm을 이용한 RC 구조물 폭발해석)

  • Park, Jae-Won;Yun, Sung-Hwan;Tak, Moon-Ho;Park, Tae-Hyo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.660-663
    • /
    • 2011
  • 폭발하중은 매우 짧은 시간 내에 순간적인 높은 압력으로 발생된다. 따라서 폭발하중을 받는 구조물은 매우 복잡한 순간 동역학적 손상 거동을 나타낸다. 이러한 외부 하중에 대한 실험적 연구는 큰 비용, 시설, 그리고 군사적 보안 문제가 요구되기 때문에, 고성능 컴퓨팅 기술을 이용한 수치적 기법을 통해 구조물의 동적 비선형 해석을 수행하였다. 수치해석의 정확성을 높이기 위해 폭풍파와 같은 대기전파의 경우 Euler 기법, 콘크리트 재료의 경우 Lagrange 기법을 적용한 복합적 수치해석 (multi-solver coupling) 기법이 적용되었다. 제안된 수치해석 기법은 explicit 유한요소해석 프로그램인 AUTODYN을 이용하여 수행되었다. 그리고 클러스터 (cluster) 내 병렬 알고리즘 (parallel algorithm)을 이용하여 수치해석의 효율성을 높였다. RC 구조물의 수치해석 결과, 기존 실험 결과와 비교하여 잘 일치되었다. 또한 영역분할 개수가 증가할수록 수행시간은 감소되었고 Speed-up과 효율성은 높아졌다.

  • PDF

Structural Safety Assessment of Offshore Structure under Explosion Loadings (해양구조물의 폭발하중에 의한 구조 안전성 평가 기법 연구)

  • Lee, Sang-Gab;Cho, Heon-Il;Hong, Anh;Kim, Jin-Kyung;Kim, Gyu-Sung;Lee, Kun-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.203-208
    • /
    • 2011
  • 본 논문에서는 해양시추 생산설비의 상부구조(topside structure)에 설치된 공정설비(process module)에서 가스 누출에 의한 가스폭발 하중에 대한 해양구조물의 비선형 동적 거동응답 특성파악을 파악하기 위하여 LS-DYNA 코드의 유체-구조 연성(Fluid-Strycture Interaction) 해석기법을 적용하여 폭발 압력파를 보다 정확하게 구현하기 위한 기법을 개발하고자 한다.

  • PDF