• Title/Summary/Keyword: 포화증기 특성

Search Result 17, Processing Time 0.028 seconds

Function approximation of steam table using the neural networks (신경회로망을 이용한 증기표의 함수근사)

  • Lee, Tae-Hwan;Park, Jin-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.459-466
    • /
    • 2006
  • Numerical values of thermodynamic properties such as temperature, pressure, dryness, volume, enthalpy and entropy are required in numerical analysis on evaluating the thermal performance. But the steam table itself cannot be used without modelling. From this point of view the neural network with function approximation characteristics can be an alternative. the multi-layer neural networks were made for saturated vapor region and superheated vapor region separately. For saturated vapor region the neural network consists of one input layer with 1 node, two hidden layers with 10 and 20 nodes each and one output layer with 7 nodes. For superheated vapor region it consists of one input layer with 2 nodes, two hidden layers with 15 and 25 nodes each and one output layer with 3 nodes. The proposed model gives very successful results with ${\pm}0.005%$ of percentage error for temperature, enthalpy and entropy and ${\pm}0.025%$ for pressure and specific volume. From these successful results, it is confirmed that the neural networks could be powerful method in function approximation of the steam table.

A Study on the Operating Characteristics by Counter Flow and Parallel Flow in Separate Heat Pipe Exchanger (분리형 히트파이프식 열교환기에서 향류 및 병류유동에 따른 가동특성에 관한 연구)

  • 이기우;장기창;유성연
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • Separate heat pipe exchanger is considered as the high thermal transportation equipment, because evaporator and condenser are separately positioned in the long distance. Its characteristics are that the working fluid is circulated naturally by the position height of two exchangers. But the operating characteristics are restricted by the temperature of hot and cold fluid, flow pattern and diameter of vapor line, etc. in this study, the vapor pressure and the minimum height of two exchangers are studied about the factors restricting the operating characteristics.

  • PDF

Function Approximation for Refrigerant Using the Neural Networks (신경회로망을 사용한 냉매의 함수근사)

  • Park, Jin-Hyun;Lee, Tae-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.677-680
    • /
    • 2005
  • In numerical analysis on the thermal performance of the heat exchanger with phase change fluids, the numerical values of thermodynamic properties are needed. But the steam table should be modeled properly as the direct use of thermodynamic properties of the steam table is impossible. In this study the function approximation characteristics of neural networks was used in modeling the saturated vapor region of refrigerant R12. The neural network consists of one input layer with one node, two hidden layers with 10 and 20 nodes each and one output layer with 7 nodes. Input can be both saturation temperature and saturation pressure and two cases were examined. The proposed model gives percentage error of ${\pm}$0.005% for enthalpy and entropy, ${\pm}$0.02% for specific volume and ${\pm}$0.02% for saturation pressure and saturation temperature except several points. From this results neural network could be a powerful method in function approximation of saturated vapor region of R12.

  • PDF

액체 금속로의 가상 사고 해석

  • 석수동;한도희
    • Nuclear industry
    • /
    • v.20 no.6 s.208
    • /
    • pp.31-44
    • /
    • 2000
  • 본 연구에서 액체금속로의 노심용융(core meltdown)으로 인한 초 즉발 임계(super-prompt critical)의 출력 폭주 사고시, 노심의 반응도 및 열수력 특성 변화와 에너지 방출량등을 계산하기 위하여, Bethe-Tait 방버론을 수정, 보완한 분석 모델이 개발되었다. 주요 보완 내용으로서는, 금속 연료 노심의 단상 액체 영역에서의 선형의(Linear) threshold 형태의 상태 방정식뿐만 아니라 포화 증기(saturated fuel vapor) 영역에서의 상태 방정식이 개발되었고, 이에 따른 노심 붕괴 반응도(disassembly reactivity)의 분석 모델이 개발되었다. 또한 도플러 반응도 효과를 고려하기 위한 분석모델도 아울러 개발되었다. 상기 보완 모델을 실행할 수 있는 수치 해석 프로그램이 개발되었고, 이를 활용하여 KALIMER에서 HCDA가 발생하였을 경우 노심에서의 에너지 방출량 계산이 수행되었다. 분석결과 도플러 효과와 포화 증기 영역에서의 압력 증가 및 노심팽창의 중요성이 확인되었다. 도플러 효과가 고려되지 않을 경우 HCDA는 분석된 모든 반응도 삽입률에 대하여 폭발적인 에너지 방출과 함께 사고가 종결되는 것으로 평가되었다. 그러나 도플러 상수가 최적 평가치인 -0.002인 경우 50$/s이하의 반응도 삽입률에서는 노심은 비등점(0.8KJ/g)에 도달치 않았으며, 설계 기준 사고인 100$/s의 경우에도 노심은 포화 증기 영역에 머물고 압력이 급격히 증가하는 단상(single phase)액체 영역의 threshold 값에 미치지 않기 때문에 사고는 핵연료 증기(vapor)의 점진적인 분산과 함께 종결되는 것으로 분석되며, 총 에너지 발생량은 약 1,800MJ로서 기계적 손상 에너지로 전환되는 분율을 고려할 때 KALIMER 원자로 용기의 구조 설계 기준치에 비해 상당한 여유도를 갖는 것으로 평가되었다.

  • PDF

A study on the measurement of void fraction using gamma ray (감마선을 이용한 기포율측정에 관한 연구)

  • Nam, Pyong-Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.9 no.1
    • /
    • pp.13-23
    • /
    • 1980
  • sing the physical characteristics of nuclear radiation penerated into the cross section of the measurement of void fraction in saturated vapor & water passing through the is analyzed theoretically and the solutions are achieved by means of computer simulation. These theoretical results are also approved through the experiment with the simulators.

  • PDF

Adsorption Analysis of Benzene Vapor in a Fixed-Bed of Granular Activated Carbon (활성탄 충전층에서 벤젠 증기의 흡착특성)

  • Kim, Seong-Soo;Kim, Jong-Hyun;Park, Sang-Wook
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.495-500
    • /
    • 2009
  • Activated carbon was used as an adsorbent to capture benzene vapor from gaseous stream of nitrogen in a fixed-bed to obtain the breakthrough data. The deactivation model is used to analyze the adsorption kinetics of benzene vapor using the experimental breakthrough data. The experimental breakthrough data are fitted very well to the deactivation model than the adsorption isotherm models in the literature.

1-D Analysis for Water Spray Cooling of Exhaust Gas in Combustor Test Facility (물 분무를 이용한 연소가스 냉각 1차원 해석)

  • Im, Ju Hyun;Kim, Myung Ho;Kim, Yeong Ryeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • The cooling of hot exhaust gas is an important issue for the construction of combustor test facility. Water spray is an effective method for exhaust gas cooling due to its large latent heat in process of evaporation. In this study, 1-D analysis has been performed based on continuity, energy conservation, and saturated vapor property to understand water spray cooling of combustion gas. In the exhaust duct of combustor test facility, the injected water decreases combustion gas temperature, and evaporates in the combustion gas. However, some of the injected water is collected in the sump due to condensation. The evaporation of water helps combustion gas cooling, but causes pressure increase inside the exhaust duct due to increase of vapor pressure. These phenomena has been analyzed by 1-D modeling in this study. From 1-D analysis, the adequate mass flow rate of water spray to cool combustion gas and to avoid excessive pressure rise inside the exhaust duct has been decided.

에어로졸 반응기 내에서 철 초미립자의 성장 특성

  • 박균영;장희동;최청송
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1997.10a
    • /
    • pp.7-11
    • /
    • 1997
  • 직경 3.5 cm, 길이 1.5 m 의 석영관 내에서 염화제1철 증기를 수소로 환원하여 철 초미립자를 제조하였다. 염화제1철의 증발조건, 염화제1철 증기와 수소의 혼합방법, 반응물의 예비가열온도, 반응온도, 염하제1철의 농도, 반응기내 체류시간이 생성된 철 입자의 크기 및 크기분포에 미치는 영향을 조사하였다. 철 입자의 평균직경은 40-88 cm 이고, 기하표준편차는 1.4 정도로 나타났다. 철 입자들은 자기적 성질에 의해 서로 연결되어 체인을 형성하였으며, 전자회절분석 결과 단결정이었다. 평균입경 55nm 철 입자들의 항자력은 900 Oe, 포화자화값은 130 emu/g 이었다.

  • PDF

A Study on the Characteristics of Refrigeration System Installed with Precooler, and Liquid-Vapor Separator after Expansion Device (과냉각기와 팽창장치 후 액기분리기를 적용한 냉동시스템 성능특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.40-45
    • /
    • 2011
  • The purpose of research is to understand the characteristics of refrigeration system having a liquid-vapor phase separator after expansion device and precooling heat exchanger. After expansion process of typical refrigerant of freezer, R134a, the cold vapor of the expanded refrigerant mixture is separated in the liquid-vapor separator and introduced in the precooling heat exchanger to enable the liquid refrigerant to be subcooled. The analysis results showed that the increasing rate of refrigeration capacity and COP can be 8.6% and 1.4%, each. The cause of these performance improvements is due to the difference of the slope of saturated vapor and saturated liquid lines in Mollier diagram of refrigerant.

Heating Characteristics of the Soils for the Application of Electrical Resistance Heating with Soil Vapor Extraction (전기 저항열을 이용한 유류 오염토 복원공정 적용을 위한 토양의 가열특성 연구)

  • Yun Yeo-Bog;Ko Seok-Oh;Park Gi-Ho;Park Min-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • This study was performed to evaluate the heating characteristics of soils for the application of electrical resistance heating process combined with soil vapor extraction. Laboratory tests were conducted to find out optimum heating conditions by the adjustment of electrical supply and electrode. Results show that fine soil particles are more efficient for electrical heating. As water content of soil increases, more efficient electrical heating is observed. However, as the soil is saturated with water above the soil porosity, decrease in the heating efficiency is observed. The higher the voltage, is and the shorter the distance between the electrodes is, the better the heating efficiency is. The soil contaminated by fuel is also more efficient than non-contaminated soil in electrical resistance heating. From the relationship between the intial electrical current and the conductivity obtained in this study, soil temperature by electrical heating can be estimated.