• Title/Summary/Keyword: 포화분극

Search Result 34, Processing Time 0.027 seconds

Adaptive Learning Circuit For Applying Neural Network (뉴럴 네트워크의 적용을 위한 적응형 학습회로)

  • Lee, Kook-Pyo;Pyo, Chang-Soo;Koh, Si-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.3
    • /
    • pp.534-540
    • /
    • 2008
  • The adaptive learning circuit is designed on the basis of modeling of MFSFET (Metal-Ferroelectric-Semiconductor FET) and the numerical results is analyzed. The output frequency of the adaptive learning circuit is inversely proportional to the source-drain resistance of MFSFET and the capacitance of the circuit. The saturated drain current with input pulse number is analogous to the ferroelectric polarization reversal. It indicates that the ferroelectric polarization plays an important role in the drain current control of MFSFET. The output frequency modulation of the adaptive learning circuit is investigated by analyzing the source-drain resistance of MFSFET as functions of input pulse numbers in the adaptive learning circuit and the dimensionality factor of the ferroelectric thin film. From the results, adaptive learning characteristics which means a gradual frequency change of output pulse with the progress of input pulse, are confirmed. Consequently it is shown that our circuit can be used effectively in the neuron synapses of neural networks.

An Experimental Study on Relationship Between Half-Cell Potential and Corrosion Current Density of Chloride-Induced Corroded Steel in Concrete (염해에 따라 콘크리트 속에서 부식된 철근의 반전지전위와 부식전류밀도의 상관관계에 관한 실험적 연구)

  • Jo, Sang-Hyeon;Kim, Dong-Won;Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.1-13
    • /
    • 2022
  • This study aims to investigate the feasibility of the half-cell potential (HCP) measurements on the concrete surface for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete. A series of experimental study is performed to measure HCP (or corrosion potential, Ecorr) and corrosion current density (icorr) of reinforcing steel in concrete cube specimens, with a side length of 200 mm. Various corrosion levels in a range of 0% to 20% of the test specimens are accelerated by impressing current to the reinforcing steel in concrete immersed in 3.0 % NaCl solution. HCP is measured in accordance with ASTM C876-15, and corrosion current density is determined by using the Stern-Geary equation and measured polarization resistance measured by electrochemical impedance spectroscopy (EIS). As a result, a numerical formula that relates HCP and icorr in the test specimen is established by a regression analysis of the measured data in this study. It is observed that HCP is linearly correlated with log(icorr) with a R2 greater than 0.87, which is less affected by the experimental variables such as concrete mixture proportion, diameter of reinforcing steel and the amount of applied current in this study. These results exhibit that HCP measurements could be effective for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete in the case of exposed to a certain consistent environment.

Development and Verification of 4-Electrode Resistivity Probe (4전극 전기비저항 탐사장비의 개발 및 검증)

  • Kim, Joon-Han;Yoon, Hyung-Koo;Jung, Soon-Hyuck;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3C
    • /
    • pp.127-136
    • /
    • 2009
  • The objective of this study is the development and verification of the 4-electrode resistivity probe (4ERP) for the estimation of electrical properties of the saturated soils. The 4ERPs with wedge and plane types are manufactured to obtain the electrical resistivity without polarization at the electrodes by using Wenner array. The wedge type is for the penetration into the soil samples and the plane type is for the installation into the cells used for the laboratory tests. The consolidation tests are carried out by using 6 types of glass beads and 3 types of sands in size. The test results show that the electrical resistivity increases with a decrease in the porosity, and the constant m used in Archie's law is dependent on the particle shape rather particle size. The one dimensional liquefaction tests show that the porosity obtained by the 4ERP is similar to that determined by the volume fraction. The penetration of the 4ERP into the large scale calibration chamber produces the resistivity profiles. This study demonstrates that the 4ERP may effectively estimate the porosity of the saturated soils.

Ferroelectric Properties of Ti-Doped and W-Doped SBT Ceramics (Ti와 W이 첨가된 SBT 세라믹스의 강유전 특성)

  • 천채일;김정석
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.5
    • /
    • pp.401-405
    • /
    • 2004
  • Undoped SrB $i_2$T $a_2$O$_{9}$, donor-doped Sr$_{0.99}$B $i_2$(Ta$_{0.99}$W$_{0.01}$)$_2$O$_{9}$ and acceptor-doped SrB $i_2$(Ta$_{0.99}$Ti$_{0.01}$)$_2$O$_{8.99$ ceramics were prepared and their microstructure, ferroelectric P-E hysteresis and Curie temperature were investigated. Grain size did not influence P-E hysteresis curve in undoped SrB $i_2$T $a_2$O$_{9}$ ceramics. Donor-Doped Sr$_{0.99}$B $i_2$(Ta$_{0.99}$W$_{0.01}$)$_2$O$_{9}$ ceramics showed more saturated P-E hysteresis curve with larger remanent polarization (P$_{r}$) than undoped SrB $i_2$T $a_2$O$_{9}$ ceramics while acceptor-doped SrB $i_2$(Ta$_{0.99}$Ti$_{0.01}$)$_2$O$_{8.99}$ ceramics led to a pinched P-E hysteresis loop. Larger polarization in donor-doped Sr$_{0.99}$B $i_2$(Ta$_{0.99}$W$_{0.01}$)$_2$O$_{9}$ ceramics resulted from easier domain wall motion by Sr-vacancies.

An Experimental Study on Corrosion Behavior in Steel of Concrete Applied with Arc Metal Spray Method Surface Treatment Technology Using EIS (EIS를 이용한 아크 금속용사 표면처리기법이 적용된 강재의 콘크리트 내 부식 거동에 관한 실험적 연구)

  • Yoon, Chang-Bok;Park, Jang hyun;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.87-95
    • /
    • 2020
  • As an experimental study on the corrosion behavior of steel materials to which ATMS method using EIS was applied in concrete, immersion of Ca(OH)2 saturated aqueous solution and NaCl aqueous solution simulating the environment inside concrete The corrosion behavior was tested. The equivalent circuit was derived through the analysis of the Nyquist plot, and the interfacial resistance and the polarization resistance of the Ca(OH)2 aqueous solution were compared, and Al ATMS was the best interfacial resistance and Zn ATMS was the best polarization resistance. After burying ATMS steel material of cement mortar, the initial immersion impedance measurement value was the highest in the Zn ATMS test body in the impedance measurement by the immersion time by immersing it in the NaCl aqueous solution. Al ATMS test piece has the highest impedance and is highly reliable. This is because Al, which has a high ionization tendency, is continuously oxidized in a strong alkaline environment to form a film and protect the steel from permeation of chlorine ions.

Corrosion Characteristics of Ti alloy for Removable Partial Denture (국소의치용 티타늄 합금의 부식 특성)

  • Kim, Jeong-Jae;Kim, Won-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.4
    • /
    • pp.237-242
    • /
    • 2014
  • In this study, surface characteristics and corrosion behaviors have been investigated in addition to Zr elements on the low elastic modulus Ti-30Ta alloy. Low elastic modulus Ti-30Ta-xZr(x : 3, 7 and 15 wt %) alloys were prepared by arc melting and then heat treated at $1000^{\circ}C$ for 24 hrs in an argon atmosphere. Microstructures of the alloys were examined by field emission scanning electron microscope(FE-SEM) and X-ray diffractometer(XRD). Electrochemical experiments were performed using a conventional three-electrode configuration with a sample working electrode, a high density carbon counter electrode and a saturated calomel reference electrode. According to the result of polarization behavior in the Ti-30Ta-xZr alloys, the current density of homogenized Ti-30Ta-15Zr in the passive region was lower than the other alloys.

Electrical and Magnetical Characteristics for PZT/Ferrite Ceramics (PZT/Ferrite 합성 세라믹의 특성에 관한 기초연구)

  • 김장용;이상현;이승봉;안형호;현충일;이명세;문병무
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.4
    • /
    • pp.153-158
    • /
    • 2003
  • This thesis deal with ferroelectric and ferromagnetic materials. PZT/Ferrite ceramics were made by the making process using PZT powder and garnet ferrite powder. PZT and ferrite are mixed as much 90%-10%, 50%-50%, and so on. After making samples, we are polishing samples until thickness is 0.1~0.2mm. We measured all kinds of samples in room temperature and applied magnetic field from -4500 to 4500 Oersted and conducted test of magnetical and electrical measurement using VSM and lpC resolution electrometer calibrated with RT66A pulsed tester. From this measurement, we can calculate tunability of these samples using C value obtained from P-E loop. As a result, it was able to measure magnetic characteristic when two matter had each other component ratio, and it was compound. However, it confirmed the possibility that was able to have ferroelectric characteristic with you in PZT 90% and ferrite 10%. Therefore, If this thing comes for PZT 50% and ferrite 50% have ferroelectric characteristic as him in a compound sample ore, can use this in an oscillator, supersonic waves detector in addition to a piezoelectric element. It may contribute to multipurpose of an element and demands such as a miniaturization of equipment, efficiency, reduce of a price which can use a characteristic of two components.

The electrical conduction and DC breakdown properties of $(Sr.Pb)TiO_3$-based ceramic ($(Sr.Pb)TiO_3$계 세라믹의 전기전도 및 DC절연파괴 특성)

  • 김충혁;정일형;이준웅
    • Electrical & Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.421-429
    • /
    • 1992
  • 본 연구에서는 (Sr.Pb)TiO$_{3}$계 세라믹을 고압용 세라믹 캐패시터로 응용하기 위하여 일반적인 세라믹 소성법으로 제작하였으며 Bi$_{2}$O$_{3}$. 3TiO$_{2}$의 첨가량에 따른 전기전도 및 DC 절연파괴 특성을 조사하였다. 전도전류는 측정온도의 상승과 Bi$_{2}$O$_{3}$.3TiO$_{2}$의 첨가량이 증가함에 따라 상승하였다. 실온에서 전도전류는 전계에 따라 3영역으로 나누어졌다. 전계 15[kV/cm]이하의 영역에서는 오음의 법칙이 성립하는 이온전도가 나타났으며 전계 15[kV/cm]~40[kV/cm]인 영역에서는 전계에 강요된 강유전성 분극의 반전게에 기인하여 전류의 포화현상이 나타났다. 전계 40[kV/cm] 이상의 영역에서는 공간전하제한전류에 관련된 차일드법칙이 성립하였다. DC 절연파괴 강도는 측정온도의 상승과 Bi$_{2}$O$_{3}$.3TiO$_{2}$의 첨가량이 증가함에 따라 감소하였다. 온도 100[.deg.C] 이하에서는 전자적파괴가 일어났으며 100[.deg.C] 이상에서는 주울열과 유전손실에 의한 열적파괴가 나타났다.

  • PDF

Properties of Sol-Gel PZT Thin films with Thickness for Micro Piezoelectric Actuators (마이크로 압전 엑츄에이터용 Sol-Gel PZT 박막의 두께 변화에 따른 특성)

  • 장연태;박준식;김대식;박효덕;최승철
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.220-223
    • /
    • 2001
  • Pb가 10% 과잉되고 Zr : Ti = 52 : 48 조성을 갖는 PZT sol이 Pt(3500Å)/Ti(400Å)/SiO₂(3000Å)Si(525㎛)기판 위에 스핀 코팅법으로 반복 코팅된 후, 450℃에서 10분, 650℃에서 2분간 반복 열처리되었다. 이와 같이 다양한 두께로 적층된 박막은 각 시편에 대해 최종적으로 650℃ 30분 동안 어닐링 처리되었다. 제조된 PZT 박막의 두께는 4100Å에서 1.75㎛사이의 4종이었다. 이어서 스퍼터링법으로 Pt전극이 PZT 막 위에 증착되었다. 제조된 PZT 박막의 결정 구조 조사를 위해 XRD, 그리고 미세 구조 및 전기적 특성을 알아보기 위해 FESEM과 P-E 이력 곡선이 각각 관찰되었다. 4100Å에서 1.75㎛까지 두께 증가에 따른 장비상의 포화 이력 한계로 잔류 분극(Pr)값이 25μC/㎠에서 다소 감소되었다. 측정된 X선 회절 결과에서 최초 4회 코팅시 perovskite 결정 구조로 성장한 결정립은 (111)배향이 우세하었으나, 두께가 증가됨에 따라 (111)/(110)값이 감소되었으며, 이를 통해 두께 증가에 따른 (111)배향성이 다소 감소됨을 알 수 있었다. 이상의 결과로부터 제조된 PZT 박막은 큰 힘과 높은 내전압 특성을 갖는 마이크로 압전 액츄에이터에 적용될 수 있을 것으로 생각되었다.

EIS monitoring on corroded reinforcing steel in cement mortar after calcium electro-deposition treatment (칼슘 전착처리 후, 시멘트 모르타르 속 철근의 부식속도에 대한 EIS 모니터링)

  • Kim, Je-Kyoung;Kee, Seong-Hoon;Yee, Jurng-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.1-8
    • /
    • 2019
  • The primary purposes of this study are to understand a fundamental effects of electro-deposition on reinforcing steel in saturated Ca(OH)2 electrolyte, and evaluate the corrosion rates of rebars under cyclic 3wt.%NaCl immersion and dry corrosion environment. The three cement mortar specimens with cover thickness 5, 10 and 30mm, were prepared in the experiment. To monitor the corrosion rates of rebars in mortar, the three cement mortar specimens were exposed to 110 wet-drying cycles(8-hour-immersion in 3wt.%NaCl and 16-hour-drying in a room temperature) in the laboratory. During the wet-dry cycles, the polarization resistance, Rp, and solution resistance, Rs, were continuously measured. The instantaneous corrosion rates of rebars on the effect of electro-depositing with sat. Ca(OH)2 electrolyte were estimated from obtained R-1p and degrees of wetness were estimated from Rs values. From the experimental results, the corrosion rates of rebars were greatly accelerated by wet/dry cycles. During the mortars exposed to drying condition, the large increases in the corrosion rates were showed at all rebar surfaces in three mortar specimen, attributed from the accelerated reduction rates of dissolved oxygen in drying process. However, the corrosion rates on rebar surface electrochemically deposited with sat. Ca(OH)2 electrolyte showed the clear decreases, caused by calcium deposits in the porous rust layer.