• Title/Summary/Keyword: 포신

Search Result 46, Processing Time 0.026 seconds

A Research on Characteristics of Internal Flow Based on the Gun Barrel Length and Ammunition Pressure. (포신 길이와 탄약 압력에 따른 포신 내부 유동 특성 연구)

  • Jung, Hee-Chur;Kim, Kyoung-Rok;Kang, Yo-Han;Ban, Young-Woo;Jung, Duck-Hyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.513-520
    • /
    • 2018
  • This research concerns the characteristics of tank barrel inner flow according to the barrel length and the pressure of ammunition when fired. By analyzing the flow characteristics of the bore evacuator according to barrel length and ammunition pressure regarding ammunition design, it is possible to prevent the flareback phenomenon that may occur during ammunition operation. Through bore evacuator flow analysis by barrel length and ammunition pressure, we identified key design factors concerning barrel and ammunition compatibility including speed, accuracy, penetration performance and range. Test results found if barrel length is long and ammunition pressure is low, bore evacuator operation time is slow. Therefore, there is a high probability that propellant gas will enter the battle vehicle. Therefore, the correlation analysis method of bore evacuator flow characteristics based on barrel length and ammunition pressure is considered as a primary method to improve operational performance. When designing new ammunition, the correlation analysis method will be used to determine ammunition weight and select the propellant pressure.

A Study on the Reliability Improvement for Assurance Pressure of Tank Gun Barrel (전차 포신의 보증압력 신뢰성 향상 연구)

  • Kim, Sung Hoon;Park, Young Min;Noh, Sang Wan;Jun, Sang Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.115-122
    • /
    • 2020
  • This study aimed to improve the reliability of the assurance pressure of a gun barrel due to the difference between the US Standard and Korean Standard. In addition, the reliability was found to differ according to the maximum pressure of the Ammunition, so restrictions are expected. During the development of the new bullet, the maximum pressure of the bullet was approximately 3,000 psi higher than the assurance pressure of the gun barrel. To solve this problem, the reliability of the cannon was analyzed when the assurance pressure of the gun barrel increased. First of all, the technical data from overseas were reviewed to check for cases of increased assurance pressure, and tests were performed to determine if it could withstand high pressure through a verification firing test. Finally, the simulation analyzed the stability of the recoil buffer. The study found no abnormal results in all items, suggesting that an increase in the assurance pressure for a gun barrel was possible. This study is expected to be used as basic data for future reliability studies of similar equipment.

An Study on the Erosion Characteristics of Tube CN98 (CN98 포신의 마모특성 연구)

  • Kim, Jae-Kab
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.42-52
    • /
    • 2006
  • Tube erosion can be defined as a phenomenon for an increment of bore diameter, a declination of accuracy and utility of tube by firing. This study introduces the characteristics of tube life for the 155 mm K9 SHP Using a tube history book with bore measurement data and firing data of standard charge, this study analyzed the EFC vs Tube life and EFC with heat transfer effect formula as a consideration of continuous firing vs tube life. The results were compared with Firing Table(FT 155-K9-1) after the analysis. Also, this study suggests that CN98 tube can be rifled as 1000 EFC through the severe condition with continuous firing.

Derivation of Fitting Approximate Formula to Enhance the Accuracy of Cannon Tube Erosion Rate (포신 마모 예측의 정확도 향상을 위한 적합 근사식 유도(I))

  • Chung, Dong-Yoon;Oh, Myoung-Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.80-87
    • /
    • 2002
  • We predict the unknown cannon tube erosion rate by using observed values of the standard cannon, 155mm Howitzer Ml85. We know the standard cannon's ten erosion observation values each 400 rounds. An approximate formula fitting the erosion values of the standard cannon has been derived. Numerical simulation applying this formula to the Rauf Imam's erosion equations is presented.

  • PDF

Combined Large Cell Neuroendocrine Carcinoma with Component of Adenocarcinoma-A case report- (선암종의 요소를 갖느느 혼압대세포신경내분비암종-1예 보고-)

  • Park Jong Un;Lee Jae Woong;Jo Tae Jun;Kim Kun Il;Lee Weon Yong;Hong Ki Woo;Eom Kwang Seok;Jun Sun-Young
    • Journal of Chest Surgery
    • /
    • v.38 no.8 s.253
    • /
    • pp.579-582
    • /
    • 2005
  • Combined large cell neuroendocrine carcinoma is an uncommon lung cancer that include large cell neuroendocrine carcinoma with components of adenocarcinoma, squamous cell carcinoma, giant cell carcinoma and/or spindle cell carcinoma histologically. We report a case that pathologically diagnosed as combined large cell neuroendocrine carcinoma with component of adenocarcinoma after right pneumonectomy and mediastinal lymph node dissection. A 44-year-old man with intermittent chest pain was referred to our hospital for lung mass on the right mid lung field.

Numerical Simulation of a Gun-launched Projectile Considering Rifled-gun Tube (포신의 강선을 고려한 포 발사 해석)

  • Joo, Geunsu;Huh, Hoon;Jung, Yeong Hyuk;Kim, Ju Yeong;Seo, Songwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.877-885
    • /
    • 2017
  • This paper is concerned with numerical simulation of a gun-launched projectile considering a rifled gun-tube. Gun-launched conditions induce dynamic behaviors, such as high pressure and high speed rotation. A projectile and its internal electronic components may be damaged in such harsh environments. Hence, it is necessary to perform numerical simulation of a gun-launched projectile to predict its dynamic behaviors and stability. In this work, preceding research studies on gun-launched projectiles are investigated, and the simulation method is developed to rotate the projectile through between its rotating band and a rifled-gun tube. The proposed method is verified by comparison with experimental results, and the dynamic behaviors and stability of the projectile are evaluated under gun-launched conditions.

Clinical Study of Renal Cystic Diseases in Children (소아의 낭포성 신질환에 대한 임상적 고찰)

  • Kim, Ja Hyung;Kim, You Jeong;Lee, Byeong Seon;Ko, Tae Sung;Park, Young Seo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.232-239
    • /
    • 2002
  • Purpose : Renal cystic diseases comprise a mixed group of heritable, developmental and acquired disorders. Recently the use of imaging modalities such as ultrasonography and radionuclide scanning has increased the detection rate of renal cystic diseases. We studied to review the clinical features and treatment of renal cystic diseases in children. Methods : This study was performed in 95 children with renal cystic diseases in the Department of Pediatrics, Asan Medical Center from October 1989 to June 2001. Results : In 95 patients, there were 55 cases(58.0%) with multicystic dysplastic kidney(MCDK), 19 cases(20.0%) with simple renal cysts, 13 cases(13.7%) with hereditary polycystic kidney diseases( 7 with autosomal recessive type, 5 with autosomal dominant type, 1 with undetermined), 6 cases(6.3%) with renal cysts in tuberous sclerosis and 1 case(1.0%) with medullary cystic disease. All MCDK patients had no renal dysfunction and hypertension during the follow-up period. Three out of 13 with polycystic kidney diseases had progressed to end-stage renal disease during the follow-up period. One case with a simple cyst underwent laparoscopic malsupialization for decompression. Conclusion : Renal cystic diseases have diverse clinicopathologic features and variable prognosis. We emphasize that routine follow-up should be performed to prevent and to detect early treatable complication in renal cystic diseases. Therefore, their natural history and treatment need further investigation and long term follow-up is required.

회원작품

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.7 s.208
    • /
    • pp.6-20
    • /
    • 1986
  • PDF

Derivation of Empirical Method to Enhance the Accuracy of Cannon Tube Erosion Rate (포신 마모 예측의 정확도 향상을 위한 실험적 방법 유도)

  • 정동윤;오명호
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.23-32
    • /
    • 2002
  • We predict the erosion rate of unknown cannon tubes by substituting measured values of the standard cannon, 155㎜ Howitzer M185 and ballistic data for the erosion equation. We know ten measured erosion values of the standard cannon at every 400 rounds. An approximate formula is derived to interpolate six values up to 2,000 rounds. Numerical example is presented and its results are analyzed. The new erosion equation is also suggested. This equation produces more accurate cannon tube erosion rate than the Rauf Imam's empirical approaches. Computer simulations are presented.

MEMS Capacitive Gap Sensor for Measuring Abrasion Depth of Gun Barrel Rifling (포신 강선의 마모 깊이 측정을 위한 정전용량 방식의 MEMS 간극센서)

  • Lee, Seok-Chan;Lee, Seung-Seob;Lee, Chang-Hwa
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.976-981
    • /
    • 2009
  • MEMS capacitive gap sensor is developed for measuring abrasion depth of gun barrel rifling. Measuring abrasion depth of gun barrel rifling is very important because it is related with exactness of firing and life of arms. The method using a gap sensor is not to hurt rifling. And it can measure abrasion depth through minimum shooting, because the developed gap sensor can measure from $1{\mu}m{\sim}12{\mu}m$ using Polydimethylsiloxane(PDMS) material and making a stretchable electrode on PDMS. And it's resolution is 1 ${\mu}m$ using capacitive method and MEMS technology.