An Application of Equivalent Heat Source for Thermal Analysis of Pavement Process (포장시 열영향 해석을 위한 등가열원의 적용성)

  • Lee, Wan-Hoon;Yoo, Byoung-Chan;Chung, Heung-Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.391-399
    • /
    • 2008
  • Because of relatively high temperature, over $240^{\circ}C$, of asphalt for steel deck bridge during pavement procedure, the temperature of deck could rise over $100^{\circ}C$ and undesirable excessive displacement and thermal stress could occur. In this study, in order to estimate the thermal effect of pavement process and to find the optimal pavement process, a new thermal analysis technique with Equivalent Heat Source (EHS) is proposed and its applicability to the practical pavement of steel bridge is studied. EHS is developed to simulate the high temperature pavement materials and its thermal effect such as conduction and convection which cannot be explain easily in general structural analysis program for bridge design. To verify the applicability of new analysis technique with EHS, thermal analyses of steel deck bridge with uplift and curved bridge with various pavement procedures are presented.

A Study on Maximum Sidewall Pressure for Underground Transmission Cables (지중송전케이블 허용측압에 관한 연구 및 기술정립)

  • Kim, Du-Jin;Lee, Ji-Yeol;Suk, Kwang-Hyun;Kim, Jae-Seung;Kim, Tai-Young;Min, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.553-554
    • /
    • 2011
  • 도심지간 대용량 전력수송을 담당하는 지중송전케이블의 설비 신뢰성 향상과 공사원가 절감을 위해 적정 포설길이의 결정과 접속함의 최적 배치가 중요하며, 이러한 시스템 설계에 있어서 허용 포설장력과 측압은 여러 중요 요소 중 하나가 된다. 특히, 허용측압 계산과정에서 적용중인 최대 측압값에 대한 실증적 검증과 건정성 확인시험을 통해 케이블 특성에 가장 적정한 값을 도출하고, 실 계통에 적용함으로서 최적 시스템 설계가 구현될 것이다. 따라서 본 연구에서는 지중송전케이블을 관로에 포설시 곡률부에서 발생하는 측압을 여러 case별로 모의할 수 있도록 실증설비를 구축하였고, 실제 작용되는 측면하중을 로드셀을 이용하여 측정하였다. 본 연구결과로 안전율을 고려한 최적의 허용측압이 결정되었으며, 이러한 허용측압의 확대를 통해 장경간 케이블 포설의 이론 정립이 가능하게 되었다.

  • PDF

Analysis on the Heat Insulation Performance of Cold Weather Concrete according to Change of Laid Construction Conditions of Double Bubble Sheets (이중버블시트의 포설 시공조건 변화에 따른 한중 콘크리트의 단열보온 성능 분석)

  • Han, Cheon-Goo;Han, Min-Cheol;Baek, Dae-Hyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.121-128
    • /
    • 2010
  • The present research examined heat insulation performance according to change of various laid construction conditions of double bubble sheet being used as material for heat insulation & curing construction of cold weather concrete, and its results are as follows. First, the change in a laid period of bubble sheet within 4 hours and the change in water content inside bubble sheet overall showed similar temperature history and maturity without a big difference in terms of the temperature history of concrete according to construction factors, but it could be confirmed that when a structure was thin or several bubble sheets are laid, requisites unfavorable for initial curing of concrete can occur if a lagger distance between sheets is generated. In terms of the compressive strength of concrete core specimens, it appeared that the initial compressive strength is declined when conditions unfavorable for concrete curing such as delay of a laid period of bubble sheets, induction of large distance between sheets, increase of water content inside bubble sheets and thinness of a structure of placing concrete, etc. were applied, but it appeared that as its age passes, the difference becomes small.

Effective Compaction Method of Hot Mix Asphalt Using Infrared Camera (Infrared Camera를 활용한 가열 아스팔트 혼합물의 효율적인 다짐관리 방안)

  • Kim, Jun-Hyung;Lee, Suck-Hong;Kim, Wan-Sang
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.105-108
    • /
    • 2007
  • In resent years, temperature segregation has been identified as one of the most important concepts concerning segregation. An Infrared Camera is one of the tools that have been recognized to be effective in identifying temperature segregation. Several state of USA have recognized the problem and have enacted Specifications, and/or test procedures to eliminate temperature segregation. The major objective of this study is to investigate effective compaction method of hot mix asphalt during road construction using Infrared Camera.

  • PDF

Laying control of a submarine cable (해저 케이블의 포설제어)

  • 양승윤;조상훈;최준호;정찬희
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.73-82
    • /
    • 2001
  • In this Paper, slack is computed from a comparision of the cable pay out rate and the ship ground speed in accordance with laying conditions, and the speed controller of the cable engine based on an $H^{\infty}$ servo control is designed for adjusting the cable engine in order to lay a desired amount of slack. The controller is designed to have the robust tracking property of the cable engine under disturbances. The performance of the designed controller is evaluated by computer simulation, and, consequently, a feasibility study for laying the submarine cable stably is done through analyzing simulation results.

  • PDF

A Study on the Slipping Down Safety of Vertical Interval for High Voltage Cable using FEM (유한요소법을 이용한 초고압 케이블 수직구간 활락 안전성에 관한 연구)

  • Lee, Ji-Hun;Choi, Seong-Kook;Yim, Ik-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.564-565
    • /
    • 2011
  • 본 연구는 154 kV, 345 kV급 초고압 케이블의 수직구간 활락 안전성에 대한 평가를 진행하였다. 안전성에 대한 평가는 유한요소해석법을 이용하여 진행하였으며, 당사에서 제작한 케이블 및 클리트에 대하여 케이블의 자중과 발열에 따른 제품 내부의 응력과 케이블의 변형량에 초점을 맞추어 비교 분석하였다. 해석 결과, 하중 및 발열에 대해 재료의 인장강도 측면에서 충분한 안전율을 가지고 있는 것으로 나타났으며, 변위 해석 또한 최대 변위 발생부가 최대 응력 발생부와 관계없는 케이블 끝단에서 나타나는 것으로 볼 때, 재료 건전성 측면에서 안전한 것으로 해석되었다. 본 연구는 향후 경사지나 수직구간의 포설 설계시 해석적 방법으로 포설 안전성을 확보하는데 기여할 수 있을 것으로 사료된다.

  • PDF

전력 케이블 열화진단 기술

  • 임종성;김보경;주태광;유성종
    • 전기의세계
    • /
    • v.45 no.4
    • /
    • pp.20-24
    • /
    • 1996
  • 오늘날 전력사용이 급증하면서 부하가 대용량화되는 추세에 따라 전기설비의 규모는 점차 대규모화 되고, 사회는 점점 고도정보화 사회로 발전되고 있다. 따라서, 설비의 사고 및 정전 등은 높은 전기적 의존도를 가진 고도 산업사회에 막대한 경제적 손실 및 장애를 가져다준다. 한편, 도시 환경의 미화차원에서 지중배전선로는 점차 증가하고 특히, 전력 케이블은 주로 공장 또는 대도시의 도로지반하에 분포하고 있어 사고시 복구에 많은 시간이 필요하며 교통 및 산업활동에 막대한 피해를 끼치게 된다. 이러한 반면에 우리나라에서는 배전용 케이블로 CV 케이블을 포설하기 시작한지 20여년이 경과되어 최근에 사고가 점증하고 있는 추세이다. 그리고, 근래에 포설한 케이블이라 할지라도 시공불량 및 기타 열악한 환경에 놓여 있게 되면 단시간에도 사고에 이를 수가 있어 설비 및 수용가에 원활한 전력공급 및 사고의 미연 방지를 위해 케이블의 열화상태를 정기적으로 진단할 필요가 있으며, 이를 위한 예방진단 기술의 연구가 필요로 하게 되었다. 본 논문은 이러한 배경하에서 케이블에서의 열화사고 현황, 절연 열화요인과 열화 process 그리고 절연진단기술의 현황 등을 알아보고, 국내 배전선로 계통인 3.3kV 및 6.6kV급 CV 케이블의 열화 진단기술 현황 및 향후 전망에 대하여 기술하였다.

  • PDF