• Title/Summary/Keyword: 포물선-직선 분포

Search Result 4, Processing Time 0.021 seconds

Compressive Stress Distribution of Concrete for Performance-Based Design Code (성능 중심 설계기준을 위한 콘크리트 압축응력 분포)

  • Lee, Jae-Hoon;Lim, Kang-Sup;Hwang, Do-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.365-376
    • /
    • 2011
  • The current Concrete Structural Design Code (2007) prescribe the equivalent rectangular stress block of the ACI 318 Building Code as concrete compressive stress distribution for design of concrete structures. The rectangular stress block may be enough for flexural strength calculation, but realistic stress-strain relationship is required for performance verification at selected limit state in performance-based design. Moreover, the ACI rectangular stress block provides non-conservative flexural strength for high strength concrete columns. Therefore a new stress distribution model is required for development of performance-based design code. This paper proposes a concrete compressive stress-strain distribution model for design and performance verification. The proposed model has a parabolic-rectangular shape, which is adopted by Eurocode 2 and Japanese Code (JSCE). It was developed by investigation of experimental test results conducted by the authors and other researchers. The test results cover high strength concrete as well as normal strength concrete. The stress distribution parameters of the proposed models are compared to those of the ACI 318 Building Code, Eurocode 2, Japanese Code (JSCE) and Canadian Code (CSA) as well as the test results.

Modeling and analysis of dynamic heat transfer in the cable penetration fire stop system by using a new hybrid algorithm (새로운 혼합알고리즘을 이용한 CPFS 내에서의 일어나는 동적 열전달의 수식화 및 해석)

  • Yoon En Sup;Yun Jongpil;Kwon Seong-Pil
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.44-52
    • /
    • 2003
  • In this work dynamic heat transfer in a CPFS (cable penetration fire stop) system built in the firewall of nuclear power plants is three-dimensionally investigated to develop a test-simulator that can be used to verify effectiveness of the sealant. Dynamic heat transfer in the fire stop system is formulated in a parabolic PDE (partial differential equation) subjected to a set of initial and boundary conditions. First, the PDE model is divided into two parts; one corresponding to heat transfer in the axial direction and the other corresponding to heat transfer on the vertical planes. The first PDE is converted to a series of ODEs (ordinary differential equations) at finite discrete axial points for applying the numerical method of SOR (successive over-relaxation) to the problem. The ODEs are solved by using an ODE solver In such manner, the axial heat flux can be calculated at least at the finite discrete points. After that, all the planes are separated into finite elements, where the time and spatial functions are assumed to be of orthogonal collocation state at each element. The initial condition of each finite element can be obtained from the above solution. The heat fluxes on the vertical planes are calculated by the Galerkin FEM (finite element method). The CPFS system was modeled, simulated, and analyzed here. The simulation results were illustrated in three-dimensional graphics. Through simulation, it was shown clearly that the temperature distribution was influenced very much by the number, position, and temperature of the cable stream, and that dynamic heat transfer through the cable stream was one of the most dominant factors, and that the feature of heat conduction could be understood as an unsteady-state process.

  • PDF

Evaluation of Skin Friction to Large Size Pneumatic Caissons (대형 뉴매틱케이슨의 주면마찰력 산정)

  • 홍원표;여규권;김태형
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.4
    • /
    • pp.15-27
    • /
    • 2004
  • In this study, skin friction evaluation methods developed f3r deep foundation system were investigated and a method that can properly evaluate the skin friction of large size pneumatic caisson was proposed. Especially, based on Hong Won-Pyo's method, new technique (Kn parameter method) was suggested for estimation of the skin friction. The $\lambda$ method used widely to pile foundation was also investigated fur the applicability of estimation of the skin friction of large size pneumatic caisson. To do this, the data measured from the pneumatic caissons installed as a substructure of main tower in the suspension bridge part of Youngjong Grand Bridge were utilized. The data show that the skin friction is proportional to the rate of sinking, and the skin friction distribution with depth is similar to parabolic type rather straight line, which is a type generally observed in pile foundation. The skin frictions predicted by the Kn and $\lambda$ methods were plotted with the measured data for comparisons. It is cleary shown that the skin frictions estimated by the proposed Kn parameter method are well matched with the measured data. That is, for the large size pneumatic caisson having wide base, the new technique developed from Hong Won-Pyo's method is more suitable for estimation of the skin friction rather than the $\lambda$ method.

Study on the Radial Variation of Structural Element in the Diffuse-Porous Woods (주요산공재(主要散孔材) 구성요소(構成要素)의 방사방향(放射方向) 변동(變動)에 관한 연구(硏究))

  • Han, Cheol-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.26-52
    • /
    • 1987
  • Among the diffuse-porous woods which arc dominant in Korea and used as construction materials due to their wood quality, ten species of six genus involving seven species of three genus in Betulaceae were studied on the radial variation of structural demenb. The species studied were Betula platyphylla var. japonica, B. ermanii, B. davurica, B. scstata, B. schmidtii, Carpinus laxifora, Alnus japonica, Prunus sargentii. Acer mono and Diospyros kaki. Wood fiber, vessel elements and ray increased rapidly in size from pith to a certain annual ring. After then the radial variation in size of the main structural elements seemed to be divided into three types; levelled off curve pattern indicating constant size(type I), continuously increasing curve pattern showing ever increase in size (type II) and parabolic curve pattern showing the gradual decrease after the maximum (type III), but the variation types by structural dements were different even in the same species. Based on the results from this study, it appears to be reasonable to consider the stabilized age of wood fiber, vessel elements and ray rather than considering wood fiber length in distinguishing mature woods from juvenile woods.

  • PDF