• Title/Summary/Keyword: 폐 PET 병

Search Result 32, Processing Time 0.031 seconds

Preparation and Characterization Study of PET Nanofiber-reinforced PEI Membrane, Investigation of the Application of Organic Solvent Nanofiltration Membrane (PET 나노섬유 강화 PEI 막의 제조 및 특성화 연구, 그에 따른 유기용매 나노여과막 가능성 검증)

  • Sung-Bae Hong;Kwangseop Im;Dong-Jun Kwon;Sang Yong Nam
    • Journal of Adhesion and Interface
    • /
    • v.24 no.1
    • /
    • pp.17-25
    • /
    • 2023
  • In this study, waste polyethylene terephthalate (PET) was recycled to produce a support and then polyetherimide (PEI) was used for environmentally friendly organic solvent nanofiltration. The prepared composite membrane was first prepared by electrospinning a PET support, then casted on the support using PEI having excellent solvent resistance, and organic solvent nanoparticles using a Non-solvent Induced Phase Separation (NIPS) method. A filtration membrane was prepared. First, the fiber diameter and tensile strength of the PET scaffold prepared prior to membrane fabrication were identified through morphology analysis, and the optimal scaffold for the organic solvent nanofiltration membrane was identified. Afterward, the PET/PEI composite membrane prepared was checked for the DEA removal rate of Congo red having a molecular weight of 697 g/mol in ethanol to understand the performance as an organic solvent nanofiltration membrane according to the concentration of PEI. Finally, the removal rate of Congo red was 90% or more.

The analysis of 18F-FDG PET/CT Images According to the Time Flow (시간흐름에 따른 18F-FDG PET/CT의 영상 분석)

  • Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.47-51
    • /
    • 2012
  • PET/CT is taken 1 hour after $^{18}F$-FDG(F-18-fluoro-2-deoxy-D-glucose) injection. However, these would be often delayed for more than 2 or 3 hours due to equipment fault or unexpected situation. In the study, SUV(standardized uptake value) were measured from got image over time according to the parts of the body. As a result, there were great and small decrease in liver(middle of the right hepatic lobe), fat(Lt pelvis), lung (Rt upper lobe), aorta(ascending aorta level) of the body in delayed image, and ${\Delta}$SUVmax was increase of 37% in bone only(L5 vertebral body) of the body. ${\Delta}$SUVmax was increase of 37.6% in lesion, and the contrast degree was greater because of uptake increase in lesion and uptake decrease in the normal body.

Diagnostic Role of F-18 FDG PET/CT in the Follow-up of Patients with Colorectal Cancer: Comparison with Serum CEA, CA 19-9 Levels and Computed Tomography (대장암 치료 후 추적 검사로서 F-18 FDG PET/CT의 역할: 혈청 CEA, CA 19-9 및 Computed Tomography와의 진단 성능 비교)

  • Kang, Sung-Min;Song, Bong-Il;Lee, Hong-Je;Seo, Ji-Hyoung;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Choi, Kyu-Suk;Jun, Soo-Han
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.120-128
    • /
    • 2009
  • Purpose: Early detection of recurrence is an important factor for long term survival of patients with colorectal cancer. Measurement of serum levels of CEA, CA 19-9, CT and PET/CT has been commonly used in the postoperative surveillance of colorectal cancer. The purpose of this study was to compare the diagnostic ability of PET/CT, tumor marker and CT for recurrence in colorectal cancer patients after treatment. Materials and Methods: F-18 FDG PET/CT imaging was performed in 189 colorectal cancer patients who underwent curative surgical resection and/or chemotherapy. Measurement of serum levels of CEA, CA 19-9 and CT imaging were performed within 2 months of PET/CT examination. Final diagnosis of recurrence was made by biopsy, radiologic studies or clinical follow-up for 6 months after each study. Results: Overall sensitivity, specificity of PET/CT was 94.7%, 91.1%, while those of serum CEA were 44.7% and 97.3%, respectively. Sensitivity and specificity were 94.2%, 90.4% for PET/CT and better than those of combined CEA and CA 19-9 measurement(52.1%, 88.5%) in 174 patients measured available both CEA and CA 19-9 data. In 115 patients with both tumor markers and CT images available, PET/CT showed similar sensitivity but higher specificity(92.9%, 91.3%) compared to combination of tumor markers and CT images(92.9%, 74.1%). Conclusion: PET/CT was superior for detection of recurred colorectal cancer patients compared with both CEA, CA 19-9, and even with combination of both tumor markers and CT. Therefore PET/CT could be used as a routine surveillance examination to detect recurrence or metastasis of colorectal cancer.

Role of FDG-PET in the Diagnosis of Recurrence and Assessment of Therapeutic Response in Cervical Cancer and Ovarian Cancer Patients: Comparison of Diagnostic Report between PET, Abdominal a and Tumor Marker (자궁경부암 및 난소암 환자 재발진단과 치료반응평가에 있어서 FDG-PET의 역할: 양전자방출단층촬영, 복부전산화단층촬영 및 종양표지자 판독의 비교 분석)

  • Han, You-Mie;Choe, Jae-Gol;Kang, Bung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.201-208
    • /
    • 2008
  • Purpose: We aimed to assess the role of positron emission tomography using fluorodeoxyglucose (FDG-PET) in the diagnosis of recurrence or the assessment of therapeutic response in cervical and ovarian cancer patients through making a comparison between FDG-PET, abdominal computed tomography (CT) and serum tumor marker. Materials and methods: We included 103 cases (67 patients) performed FDG-PET and abdominal CT. There were 42 cervical cancers and 61 ovarian cancers. We retrospectively reviewed the interpretations of PET and CT images as well as the level of tumor marker. We calculated their sensitivity, specificity, positive predictive value and negative predictive value for these three modalities. And then we analyzed the differences between these three modalities. Results: Tumor recurrences were diagnosed in 37 cases (11 cervical cancers and 26 ovarian cancers). For PET, CT and tumor marker, in cervical cancer group, sensitivity was 100% (11/11), 54.5% (6/11) and 81.1% (9/11), respectively. And specificity was 93.6% (29/31), 93.6% (29/31) and 100% (31/31). In ovarian cancer group, sensitivity was 96.2% (25/26), 84.6% (22/26) and 80.8% (21/26), and specificity was 94.3% (33/35), 94.3% (33/35), 94.3% (33/35), PET was highly sensitive to detect the intraperitoneal and extraperitoneal metastasis with the help of the CT images to localize the lesions. However, CT had limitations in differentiation of the recurrent tumor from benign fibrotic tissue, identification of viable tumors at the interface of tissues, and detecting extraperitoneal lesions. Conclusion: FDG-PET can be an essential modality to detect the recurrent or residual tumors in gynecologic cancer patients because of its great field of the application and high sensitivity.

A Case of Primary Choriocarcinoma of the Lung (원발성 폐 융모막암종 1예)

  • Cho, Young-Jae;Lee, Sei Won;Lee, Sang Min;Yim, Jae-Joon;Yoo, Chul-Gyu;Han, Sung Koo;Shim, Young-Soo;Kim, Young Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.6
    • /
    • pp.578-584
    • /
    • 2006
  • A primary choriocarcinoma of the lung is extremely rare, and difficult to distinguish from a metastatic choriocarcinoma considering that the lung is also one of the most frequent sites of metastasis. We report a 28-year-old woman patient who was initially misdiagnosed with an ectopic pregnancy and was operated on under the impression of an unidentified malignancy of the lung, which was finally proven to be a choriocarcinoma of the lung. A pelvic examination by a gynecologist, pelvic magnetic resonance imaging and whole body fluorodeoxyglucose positron emission tomography-computed tomography was performed in order to rule out a metastatic choriocarcinoma of the lung. After a curative operation, her serum ${\beta}$-human chorionic gonadotropin (HCG) level, which was highly elevated in the initial evaluation, had decreased dramatically to the normal range. She is currently being followed up regularly without any evidence of recurrence or elevation of her ${\beta}$-HCG level.

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

F-18-FDG Whole Body Scan using Gamma Camera equipped with Ultra High Energy Collimator in Cancer Patients: Comparison with FDG Coincidence PET (종양 환자에서 초고에너지(511 keV) 조준기를 이용한 전신 F-18-FDG 평면 영상: Coincidence 감마카메라 단층 촬영 영상과의 비교)

  • Pai, Moon-Sun;Park, Chan-H.;Joh, Chul-Woo;Yoon, Seok-Nam;Yang, Seung-Dae;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.65-75
    • /
    • 1999
  • Purpose: The aim of this study is to demonstrate the feasibility of 2-[fluorine-18] fluoro-2-deoxy-D-glucose (F-18-FDG) whole body scan (FDG W/B Scan) using dual-head gamma camera equipped with ultra high energy collimator in patients with various cancers, and compare the results with those of coincidence imaging. Materials and Methods: Phantom studies of planar imaging with ultra high energy and coincidence tomography (FDG CoDe PET) were performed. Fourteen patients with known or suspected malignancy were examined. F-18-FDG whole body scan was performed using dual-head gamma camera with high energy (511 keV) collimators and regional FDG CoDe PET immediately followed it Radiological, clinical follow up and histologic results were correlated with F-18-FDG findings. Results: Planar phantom study showed 13.1 mm spatial resolution at 10 cm with a sensitivity of 2638 cpm/MBq/ml. In coincidence PET, spatial resolution was 7.49 mm and sensitivity was 5351 cpm/MBq/ml. Eight out of 14 patients showed hypermetabolic sites in primary or metastatic tumors in FDG CoDe PET. The lesions showing no hypermetabolic uptake of FDG in both methods were all less than 1 cm except one lesion of 2 cm sized metastatic lymph node. The metastatic lymph nodes of positive FDG uptake were more than 1.5 cm in size or conglomerated lesions of lymph nodes less than 1cm in size. FDG W/B scan showed similar results but had additional false positive and false negative cases. FDG W/B scan could not visualize liver metastasis in one case that showed multiple metastatic sites in FDG CoDe PET. Conclusion: FDG W/B scan with specially designed collimators depicted some cancers and their metastatic sites, although it had a limitation in image quality compared to that of FDG CoDe PET. This study suggests that F-18-FDG positron imaging using dual-head gamma camera is feasible in oncology and helpful if it should be more available by regional distribution of FDG.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

Solitary Plasmacytoma of the Rib - A case report - (늑골에 발생한 고립성 형질세포종 - 1예 보고 -)

  • Lee, Young-Ok;Ryu, Kyoung-Min;Cho, Suk-Ki;Lee, Eung-Bae
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.268-271
    • /
    • 2009
  • Solitary plasmacytoma of bone is a rare disease that accounts for only about $3{\sim}5%$ of all plasma cell tumors. Especially, no case of solitary plasmacytoma of a rib origin has been described in the Korean literature. A 54 year old Korean man was referred to our hospital for further evaluation of a lung mass that had been detected on a screening chest radiograph. A tumor with a left 6th rib origin was revealed by the computed tomography(CT) and positive emission tomography (PET-CT); therefore, surgical resection was performed. The histopathological findings of the tumor revealed plasmacytoma of a rib origin. The postoperative screening test revealed no evidence of multiple myeloma. Postoperative radiation therapy was not performed, and no new lesion has been noted during the 2 years of follow up.

Difference in F-18 FDG Uptake According to the Patterns of CT-Based Diagnosed Pulmonary Lymphangitic Carcinomatosis in Patients with Lung Cancer (폐암환자에 있어 CT상으로 진단된 폐림프관성암종증의 형태에 따른 F-18 FDG 섭취의 차이)

  • Jun, Sung-Min;Kim, Yong-Ki;Kim, In-Ju;Kim, Seong-Jang;Nam, Hyun-Yeol;Kim, Bum-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.292-300
    • /
    • 2008
  • Purpose: Our purpose was to evaluate F-18 FDG uptake in pulmonary lymphangitic carcinomatosis (PLC) according to CT findings and histology of lung cancer. Materials and Methods: Thirty-three lung cancer patients with PLC were enrolled in this retrospective study. All the patients had a CT-based diagnosis of PLC. Chest CT findings of PLC were classified on the basis of involvement of axial interstitium. We categorized the involvement of axial interstitium as group 1, and the involvement of peripheral interstitium only as group 2. Visual and semiquantitative analyses by F-18 FDG PET/CT were performed in the PLC lesions. At first, we analyzed the F-18 FDG uptake in the PLC by visual assessment. If abnormal uptake was seen in the PLC, we drew regions of interest in the PLC lesions to obtain the maximum SUVs (maxSUVs). Results: Of the 33 patients, 22 had abnormal F-18 FDG uptake in the visual assessment. There was no significant difference in the frequency of abnormal F-18 FDG uptake between group 1 and group 2 (p=0.17), although the frequency of group 1 tended to be higher than group 2 (15/19 (78.9%) in group 1, 7/14 (50.0%) in group 2). However, group 1 had a higher maxSUV than group 2 (p<0.01, group 1: $2.9{\pm}1.4$, group 2: $1.5{\pm}0.6$). There was no significant difference in the frequency of abnormal F-18 FDG uptake and maxSUV among the histology of the lung cancers. Conclusion: The involvement of axial interstitium in the PLC by lung cancer has a higher maxSUV than the involvement of only peripheral interstitium.