• Title/Summary/Keyword: 폐용적

Search Result 103, Processing Time 0.03 seconds

Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques (유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰)

  • Kim, Young-Bum;Lee, Sang-Rok;Chung, Se-Young;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Purpose: A various find of radiotherapy treatment plans have been made to determine appropriate doses for breasts, chest walls and loco-regional lymphatics in the radiotherapy of breast cancers. The aim of this study was to evaluate the optimum radiotherapy plan technique method by analyzing dose distributions qualitatively and quantitatively. Materials and Methods: To evaluate the optimum breast cancer radiotherapy plan technique, the traditional method(two dimensional method) and computed tomography image are adopted to get breast volume, and they are compared with the three-dimensional conformal radiography (3DCRT) and the intensity modulated radiotherapy (IMRT). For this, the regions of interest (ROI) such as breasts, chest walls, loco-regional lymphatics and lungs were marked on the humanoid phantom, and the computed tomography(Volume, Siemens, USA) was conducted. Using the computed tomography image obtained, radiotherapy treatment plans (XiO 5.2.1, FOCUS, USA) were made and compared with the traditional methods by applying 3DCRT and IMRT. The comparison and analysis were made by analyzing and conducting radiation dose distribution and dose-volume histogram (DVH) based upon radiotherapy techniques (2D, 3DCRT, IMRT) and point doses for the regions of interest. Again, treatment efficiency was evaluated based upon time-labor. Results: It was found that the case of using 3DCRT plan techniques by getting breast volume is more useful than the traditional methods in terms of tumor delineation, beam direction and confirmation of field boundary. Conclusion: It was possible to present the optimum radiotherapy plan techniques through qualitative and quantitative analyses based upon radiotherapy plan techniques in case of breast cancer radiotherapy. However, further studies are required for the problems with patient setup reproducibility arising from the difficulties of planning target volume (PVT) and breast immobilization in case of three-dimensional radiotherapy planning.

  • PDF

Effects of Modified Ultrafiltration in Pediatric Open Heart Surgery (소아 개심술에 있어서 변형초여과법의 효과)

  • 전태국;박표원
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.591-597
    • /
    • 1997
  • Cardiopulmonary bypass in children is associated with capillary leak which results in an increase in total body water after open heart surgery The purpose of these studies was to assess the cardiopulmonary effects of modified ultrafiltration after pediatric open heart surgery Study h: Twenty-six consecutive children aged 0.1 ~ 10 years(median 7 months) underwent cardiac operation inc rporating modified ultrafiltration. After completion of cardiopulmonary bypass, modified ultrafiltration was commenced at the flow rate of 100~ 15011min for 3 ~ 14 min. After modified ultrafiltration, elevation of hematocrit(28.3% $\pm$ 3.6% vs. 33.8olo $\pm$ 4.Ooloi p < 0.001), increased systolic 1)loots Pressure(66.7 $\pm$ 11.2mmHg vs. 76.2$\pm$ 11.BmmHg, p < 0.02), and decreased central venous pressure(7.8 $\pm$ 3.7mmHg vs. 6.9$\pm$ 2.gmmHg, p<0.001) were observed. Study B: Twenty-six children who underwent cardiac operation with the diagnosis of VSD under 2 years were assigned to control(n= 14) or modified ultrafiltration(n= 12). Peak inspiratory pressure checked immediately after operation was significantly lower in modified ultrafiltration group than in control group(20.0$\pm$ 2.4 cmH20 vs.22.4$\pm$ 2.3cmH20, p < 0.03). Modified ultrafiltration after cardiopillmonary bypass in children improves early homodynamics and pulmonary mechanics, and represents an excellent option for perioperative managemen of accumulation of fluid in the tissues. We will continually employ the modified ultrafiltration technique in pediatric cardiac operations.

  • PDF

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

Evaluation 4D-CT Simulation used of Motion Organ and Tumor for Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 4D-CT simulation을 이용한 동적장기와 종양 움직임 평가)

  • Kim, Seung-Chul;Kim, Min-A
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.395-402
    • /
    • 2015
  • when the radiation therapy of chest and abdomen, evaluation of the tumor motion and the data was used to minimize damage to normal tissues by separating the tumor and normal tissue and maximize tumor therapeutic effect. Lung and liver cancer each 20 patients based on the 50% top phase using 4D-CT simulation and Light speed-16 of shooting equipment 30 ~ 70 % gating phase interval and 0 ~90 % movement in the full phase interval was measured. If the full phase 0 ~ 90% with gating phase 30~70% of tumors in the liver and lung is shown the biggest difference compared to the motion and the size of the GTV was the largest difference in the I(inferior), full phase 0~90% degree of tumor motion only when a relatively large, gating phase to 30~70% of the tumor when the movement has been found that the reduced average 7.1mm. In the 4D-CT simulation comparing the motion value when the full phase 0~90 % and gating phase 30~70 % when the motion value, twice in the gating phase 30~70 % more than full phase 0~90 % showed a small movement value. The exposure to normal tissues, based on the results obtained from the 4D-CT simulation can be significantly alleviated, After treatment will reduce pain and disability in patients with radiation is expected to be able to effective treatment.

Arterial Switch Operation for Transposition of G rest Arteries (대혈관전위증에 대한 동맥전환술)

  • 이호철;류한영
    • Journal of Chest Surgery
    • /
    • v.29 no.3
    • /
    • pp.278-284
    • /
    • 1996
  • Nine infants with transposition of great arteries have undergone arterial switch operation from May 1989 to May 1994 in the Department of Thoracic and Cardiovascular Surgery, Yeungnam University Hospital. Patients' age ranged from 3 days to 90 days, averaging 30$\pm$21 days. Diagnosis was made by two-dimensional echocardiography in all patients. Eight patients were diagnosed as transposition of great arteries with ventricular septal defect and one patient was a simple transposition of great arteries. Associated anomalies were patent ductus arteriosus (8), atrial septal defect (7) and coarctation of aorta(1). The anatomy of the coronary arteries were 7 (77 %) type A and 2 (23 %) type D according to the Yacoub classification. Pulmonary artery reconstruction was done according to Lecompte maneuver with tautologous pericardial patch in 8 patients. Overall operative mortality rate was 55% Left heart failure and pulmonary hypertensive crisis were the cause of death on postoperative 1~2 days in three patients, and two succumbed to death due to sepsis on postoperative 2~ 3 weeks. The mean follow-up period was mean 17 months. No patient had clinically significant postoperative aortic regurgitation and supravalvular pulmonary stenosis. The excessive use of inotropic support postoperatively was identified as a stastically significant risk factor following the arterial switch operation. But other variables such as low body weight, long cardiopulmonary bypass time, excessive hemodilution during cardiopulmonary bypass, hypothermia and volume loading were not significant risk factors.

  • PDF

Utilization of Egg-shell for Bread-making (제빵시 난각의 이용에 관한 연구)

  • Kim, Joong-Man;Kim, Yong-Seob;Yang, Hee-Chon;Choi, Yong-Bae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.18 no.2
    • /
    • pp.160-166
    • /
    • 1989
  • This study was conducted to investigate whether egg-shell may be used as a mineral sourceor leavening agent in breadmaking. In Korea the waste volume of egg shell has been estimated at about 28,694 tons per year. Carbon dioxide generation maxima were established for barking powder$(153{\pm}3ml/g)$, egg-shell(205in reaction with lactic acid) and yeast$(115{\pm}3ml/sugar\;g)$. Gas release time required for each substance to reach $CO_2$ maximum was, for baking powder 7 minutes, for egg-shell 45 mins and for yeast 240 mins. Particle size of egg-shell in breadmaking was suitable more than 20 mesh (-). When egg-shell only was added to the basic formular without including lactic acid, no leavening effect was observed. However, when lactic acid and egg-shell were used together, the leavening effect was more or less equivalent to that of yeast(control). Addition of egg-shell was found to increase calcium content of bread products without noticeable altering flavor, as compared with control. Joint use of egg-shell was organic acids in breadmaking was shown to have potential in time saving, volume increase and yeast saving.

  • PDF

Treatment of Multiple Rib Fracture and Flail Chest with Judet's Strut-105 Case REport- (다발성 늑골골절 및 Flail Chest 환자에서 Judet's strut를 이용한 수술적 고정술 105례)

  • Park, Byeong-Sun;Jo, Wan-Jae;O, Jeong-U
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.803-808
    • /
    • 1997
  • There were 105 patients with multiple rib fracture or flail chest who had underwent surgical rib fixation using judet's strut from Aug. 1989 to Aug. 1995. They were 86 men and 19 women, and the age distribution was from 17 to 77(mean $48\pm12).$ The most common cause of accident was a traffic accident(81%), The mean number of rib fracture was 5.5 and the distribution of patient were flail chest(72, 64.7%), severe displaced rib Fracture(18, 17.1%), traumatic chest wall deformity(10, 95%) and others(5, 4.7%). The operative mortality was 1 patient(0.96%) and the incidence of postoperative complication were 13 patients(12.3%). The duration of perioperative artificial ventilator therapy was $90.5\pm22.6$ hours. Our method allowed shorter duration of an artificial ventiatin and decreased a functional sequelae. We find this technique to be better than previously published methods, since it provides better stabilization and immobilization of he ribs and thus obviates the need for artificial ventilation and prevents post-traumatic chest deformity.

  • PDF

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

Resting Energy Expenditure in Patients with Lung Cancer (폐암 환자의 안정시 에너지 소비)

  • Lee, Jae-Lyun;Kim, Ki-Beom;Lee, Hak-Jun;Jung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1019-1029
    • /
    • 1997
  • Background : Elevation of resting energy expenditure(REE) in patients with lung cancer has been described in earlier studies and may contribute to cancer cachexia, but limited information is available regarding the prevalence and determinants of the increased REE. The aim of this study was to assess the prevalence and contributing factors of a hypermetabolic state in newly detected patients with lung cancer and to assess the energy balance in order to improve our knowledge about weight loss in patients with lung cancer. Method : Thirty one consecutive, newly detected patients with lung cancer and 20 control patients with benign lung diseases were included in this study. Resting energy expenditure(REE) was measured by indirect calorimetry using ventilated hood system and predicted REE was calculated by the Harris-Benedict formular. Results : The energy balance in newly detected lung cancer patients was disturbed in a high proportion of patients, and hypermetabolic state occurred in 61% of the patients. Tumor volume, cancer type, location, stage, the presence of atelectasis or infiltration, pulmonary function, or smoking behavior were not associated with increase in REE. But patients with distant metastasis had significantly higher REE comparing with patients without metastasis. Thirty nine percents of the patients with lung cancer had substantial loss of more than 10% of their pre-illness weight. Weight losing patients with lung cancer were not accompanied by an increase in REE. Conclusion : We concluded that the REE was elevated in a higher proportion of patients with lung cancer and distant metastasis was found to be contributing factor to the elevated REE.

  • PDF

Analysis of Radiation Treatment Planning by Dose Calculation and Optimization Algorithm (선량계산 및 최적화 알고리즘에 따른 치료계획의 영향 분석)

  • Kim, Dae-Sup;Yoon, In-Ha;Lee, Woo-Seok;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.137-147
    • /
    • 2012
  • Purpose: Analyze the Effectiveness of Radiation Treatment Planning by dose calculation and optimization algorithm, apply consideration of actual treatment planning, and then suggest the best way to treatment planning protocol. Materials and Methods: The treatment planning system use Eclipse 10.0. (Varian, USA). PBC (Pencil Beam Convolution) and AAA (Anisotropic Analytical Algorithm) Apply to Dose calculation, DVO (Dose Volume Optimizer 10.0.28) used for optimized algorithm of Intensity Modulated Radiation Therapy (IMRT), PRO II (Progressive Resolution Optimizer V 8.9.17) and PRO III (Progressive Resolution Optimizer V 10.0.28) used for optimized algorithm of VAMT. A phantom for experiment virtually created at treatment planning system, $30{\times}30{\times}30$ cm sized, homogeneous density (HU: 0) and heterogeneous density that inserted air assumed material (HU: -1,000). Apply to clinical treatment planning on the basis of general treatment planning feature analyzed with Phantom planning. Results: In homogeneous density phantom, PBC and AAA show 65.2% PDD (6 MV, 10 cm) both, In heterogeneous density phantom, also show similar PDD value before meet with low density material, but they show different dose curve in air territory, PDD 10 cm showed 75%, 73% each after penetrate phantom. 3D treatment plan in same MU, AAA treatment planning shows low dose at Lung included area. 2D POP treatment plan with 15 MV of cervical vertebral region include trachea and lung area, Conformity Index (ICRU 62) is 0.95 in PBC calculation and 0.93 in AAA. DVO DVH and Dose calculation DVH are showed equal value in IMRT treatment plan. But AAA calculation shows lack of dose compared with DVO result which is satisfactory condition. Optimizing VMAT treatment plans using PRO II obtained results were satisfactory, but lower density area showed lack of dose in dose calculations. PRO III, but optimizing the dose calculation results were similar with optimized the same conditions once more. Conclusion: In this study, do not judge the rightness of the dose calculation algorithm. However, analyzing the characteristics of the dose distribution represented by each algorithm, especially, a method for the optimal treatment plan can be presented when make a treatment plan. by considering optimized algorithm factors of the IMRT or VMAT that needs to optimization make a treatment plan.

  • PDF