• Title/Summary/Keyword: 폐색영역

Search Result 127, Processing Time 0.021 seconds

Intermediate View Image and its Digital Hologram Generation for an Virtual Arbitrary View-Point Hologram Service (임의의 가상시점 홀로그램 서비스를 위한 중간시점 영상 및 디지털 홀로그램 생성)

  • Seo, Young-Ho;Lee, Yoon-Hyuk;Koo, Ja-Myung;Kim, Dong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.15-31
    • /
    • 2013
  • This paper proposes an intermediate image generation method for the viewer's view point by tracking the viewer's face, which is converted to a digital hologram. Its purpose is to increase the viewing angle of a digital hologram, which is gathering higher and higher interest these days. The method assumes that the image information for the leftmost and the rightmost view points within the viewing angle to be controlled are given. It uses a stereo-matching method between the leftmost and the rightmost depth images to obtain the pseudo-disparity increment per depth value. With this increment, the positional informations from both the leftmost view point and the rightmost view point are generated, which are blended to get the information at the wanted intermediate viewpoint. The occurrable dis-occlusion region in this case is defined and a inpainting method is proposed. The results from implementing and experimenting this method showed that the average image qualities of the generated depth and RGB image were 33.83[dB] and 29.5[dB], respectively, and the average execution time was 250[ms] per frame. Also, we propose a prototype system to service digital hologram interactively to the viewer by using the proposed intermediate view generation method. It includes the operations of data acquisition for the leftmost and the rightmost viewpoints, camera calibration and image rectification, intermediate view image generation, computer-generated hologram (CGH) generation, and reconstruction of the hologram image. This system is implemented in the LabView(R) environments, in which CGH generation and hologram image reconstruction are implemented with GPGPUs, while others are implemented in software. The implemented system showed the execution speed to process about 5 frames per second.

Role of Peptides in Antiviral (COVID-19) Therapy

  • Chelliah, Ramachandran;Daliri, Eric Banan-Mwine;Elahi, Fazle;Yeon, Su-Jung;Tyagi, Akanksha;Park, Chae Rin;Kim, Eun Ji;Jo, kyoung Hee;Oh, Deog-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.5
    • /
    • pp.363-375
    • /
    • 2021
  • Trends in the developing era to discover and design peptide-based treatments throughout an epidemic infection scenario such as COVID-19 could progress into a more efficient and low-cost therapeutic environment. However, the weakening of proteolysis is one downside of natural peptide drugs. But, peptidomimetics may help resolve this issue. In this review, peptide and peptide-based drug discovery were summarized to target one key entry mechanism of severe coronavirus pulmonary emboli syndrome (SARS-CoV-2), which encompasses the association of the host angiotensin-converting enzyme-2 (ACE2) receptor and viral spike (S) protein. Furthermore, the benefits of proteins, peptides and other possible actions that have been studied for COVID-19 through new peptide-based treatments are discussed in the review. Lastly, an overview of the peptide-based drug therapy environment is comprised of an evolutionary viewpoint, structural properties, operational thresholds, and an explanation of the therapeutic area.

A Study on Mechanical Properties and Applicability of CNT-Mixed Grout (CNT-Mixed grout의 역학적 특성 및 적용성 연구)

  • Kim, Seunghyun;Kim, Kanghyun;Shin, Jongho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.9
    • /
    • pp.5-16
    • /
    • 2022
  • In recent years due to the development of urban and underground space, the number of ground disasters is increasing, and it is also leading to social problems. To solve the problem, a grouting method is generally used. However, the grouting method has material (grout) limitations in permeability, gelation properties and tensile resistance. Therefore, research on grout materials mixed with fibers is actively carried out to improve the problems. However, in the actual ground injection process, many difficulties have been faced causing the blockage of the inlet port and the injection tube. In this study, 'CNT-mixed grout material' was developed using CNT powder that can reinforce the tensile strength of soils. The uniaxial compressive and tensile strength tests were performed to obtain the optimal content and mechanical properties of the CNT Powder-mixed grout. It was found that the optimal CNT powder content is 0.5% that gives the average maximum strength. A one-dimensional injection test and the bulb formation test were carried out, and it was identified that the injection rate and bulb form could be controlled by pressure and mixing ratio. Field application of the CNT-Mixed grout is simulated using numerical analysis of slopes, foundations, and tunnels reinforced in several types. The positive effect of reducing plastic ranges and settlements was confirmed.

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

Postoperative Radiation Therapy in the Management of Early Cervical Cancer (초기 자궁경부암의 수술 후 방사선치료의 효과)

  • Kim, Jae-Chul
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.164-170
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: This study identified the result of postoperative radiation therapy and the prognostic factors to affect survival rates in cancer patients. $\underline{Materials\;and\;Methods}$: One hundred and thirty three patients with cervical cancer who were treated with postoperative radiation therapy following surgery at our institution between June 1985 and November 2002 were retrospectively analyzed. One hundred and thirteen patients had stage IB disease, and 20 patients had stage IIA disease. Histological examination revealed 118 squamous cell carcinoma patients and 15 adenocarcinoma patients. Sixty seven patients were noted to have stromal invasion greater than 10 mm, and 45 patients were noted to have stromal Invasion 10 mm or less. Positive lymphovascular invasion was found in 24 patients, and positive pelvic lymph nodes were noted in 39 patients. Positive vaginal resection margin was documented in 8 patients. All of the patients were treated with external beam radiation therapy to encompass whole pelvis and primary surgical tumor bed. Intracavitary radiation therapy was added to 19 patients who had positive or close surgical margins. $\underline{Results}$: Actuarial overall and disease-free survival rates for entire group of the patients were 88% and 84% at 5 years, respectively. Five-year disease-free survival rates for patients with stromal invasion greater than 10 mm and 10 mm or less were 76% and 97%, respectively (p<0.05). Also there was a significantly lower survival in patients with positive pelvic lymph nodes compared with patients with negative pelvic lymph nodes (p<0.05). However, lymphovascular invasion, positive vaginal resection margins were not statistically significant prognostic factors. Addition of neoadjuvant chemotherapy or type of surgery did not affect disease-free survival. $\underline{Conclusion}$: Postoperative radiation therapy appears to achieve satisfactory local control with limited morbidity in cervical cancer patients with high pathologic risk factors. Distant metastasis was a dominant failure pattern to affect survival in cervical cancer patients after radical surgery and radiation and more effective systemic treatment should be investigated in these high-risk patients.

Radiographic Evaluation of Adenoidal Size and Assessment of Impedance Audiometry in Children (소아 인두편도의 방사선적 고찰 및 Impedance 청력검사 소견)

  • 김주일;김철우;이병희;천경두
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.41.2-41
    • /
    • 1981
  • Tonsillectomy and adenoidectomy are the most common operations in the ENT field. Recent emphasis on careful selection of patients for these procedures derives from concern for complications of surgery, as well as the immunologic and anatomic functions of tonsils and adenoids. Adenoidectomy can relieve nasopharyngeal airway obstruction caused by enlarge adenoids, and can prevent complications such as heart failure and recurrent or chronic otitis media. We researched 117 cases of tonsilloadenoidectomy patients and 266 patients having routine examination from March, 1979 to February, 1981, and described the A/N ratio derived from linear measurements of lateral radiographs of the nasopharynx. The results of Impedance Audiometry and X-ray films from 117 cases of T&A patients were compared: 1) The average A/N ratio by age groups for 266 cases of normal children showed: 0.508 for age group, 0 to 3 years old, 0.533 for age group, 4 to 6 years old, 0.524 for age group, 7 to 9 years old, 0.519 for age group, 10 to 12 years old, 0.507 for age group, 13 to 15 years old, 0.481 for age group over 15 years old. The peak value lies in the age group of 4 to 6 years old. The sex difference of A/N ratio was not significant. 2) The average A/N ratio by age groups from 117 cases of T&A patients showed: 0.709 for age group, 0 to 3 years old, 0.733 for age group, 4 to 6 years old, 0.693 for age group, 7 to 9 years old, 0.707 for age group, 10 to 12 years old, 0.620 for age group, 13 to 15 years old, 0.756 for age group over 15 years old. 3) Among the 117 cases of T&A patients, the average A/N ratio for 57 cases in normal tympanogram was 0.688 and the average A/N ratio for 60 cases in abnormal tympanogram was 0.705. 4) Among 57 cases in abnormal tympanogram: 6 cases (10.5%) showed 0.40-0.59 of A/N ratio, 44 cases (77.2%) showed 0.60-0.79 of A/N ratio, and 7 cases (12.3%) showed 0.80-0.99 of A/N ratio. 5) Among 117 cases of T&A patients, 3 of 15 cases showing A/N ratio under 0.6, and 67 of 102 cases showing A/N ratio over 0.6, had paranasal sinusitis.

  • PDF

Evaluation of Patient Radiation Doses Using DAP Meter in Interventional Radiology Procedures (인터벤션 시술 시 면적선량계를 이용한 환자 방사선 선량 평가)

  • Kang, Byung-Sam;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.27-34
    • /
    • 2017
  • The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipments in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effectives of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were $237.7Gy{\cdot}cm^2$ in TACE, $17.3Gy{\cdot}cm^2$ in AVF, $114.1Gy{\cdot}cm^2$ in LE PTA & STENT, $188.5Gy{\cdot}cm^2$ in TFCA, $383.5Gy{\cdot}cm^2$ in Aneurysm Coil, $64.6Gy{\cdot}cm^2$ in PTBD, $64.6Gy{\cdot}cm^2$ in Biliary Stent, $22.4Gy{\cdot}cm^2$ in PCN, $4.3Gy{\cdot}cm^2$ in Hickman, $2.8Gy{\cdot}cm^2$ in Chemo-port, $4.4Gy{\cdot}cm^2$ in Perm-Cather, $17.1Gy{\cdot}cm^2$ in PCD, and $357.9Gy{\cdot}cm^2$ in Vis, EMB. Dose referenece level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipments and procedures in the interventional radiology procedures, further studies and monitorings are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.