• Title/Summary/Keyword: 폐동맥 카테터

Search Result 12, Processing Time 0.039 seconds

Transcatheter Intravascular Stent Placement in a Shih Tzu Dog with Refractory Pulmonic Stenosis (카테터를 통한 혈관스텐트 장착을 통한 심한 폐동맥협착증 치료 1례)

  • Kim, Hyun-Wook;Kim, Sung-Soo;Lee, Joon-Soek;Nam, So-Jeong;Choi, Ran;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.48-53
    • /
    • 2009
  • A 4-year-old intact male Shih Tzu dog (5.4 kg of body weight) was referred with primary complaints of heart murmur and exercise intolerance. Diagnostic studies found severe valvular pulmonic stenosis (peak velocity of 6.4 m/s, pressure gradient 165 mmHg). The dog was treated with 3 cm (length) ${\times}$ 1.5 cm (diameter) of Palmaz biliary stent. The outcome of stent placement was favorable and remarkably reduced the severity of PS (6.4 m/s to 3.0 m/s of peak velocity). Clinical condition was remarkably improved with the absence of cardiac murmur, although mild pulmonic regurgitation existed from the day of stent placement. To our best knowledge, this case is the first clinical trial for treating PS with intravascular stent in Korea.

An Experimental Study of Percutaneously Adjustable Pulmonary Artery Banding Device (가변성 폐동맥 혈류조절기의 실험적 연구)

  • Gang, Gyeong-Hun;Kim, Sang-Hyeon
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.580-584
    • /
    • 1997
  • To overcome the problems of classical pulmonary banding procedure, we developed a percutaneously adjustable pulmonary artery ba ding device. The banding device consists of banding portion of zig-zag shaped self-expandable stainless steel wire, shaft portion made by a polyvinyl catheter and a screw adjuster which includes a bolt and a nut. As the screw moves, the diameter of banding portion changes. Four Mongrel dogs ranging from 15 kg to 20 kg in weight underwent the banding of the mid portion of descending aorta with this devices through the left thoracotomy. One month after operation, we evaluated the pressure changes by controling the banding with the devices and then the dogs were sacrificed to study the microscopic changes in the aorta. The diameter and circumference of the band could be easily and finely adjustable by the screw control. The pressure recordings . revealed a linear increase and decrease in pressure gradient according to percutaneous ad;ustment of the banding device. Since the banding device can be easily placed and simply adjusted percutaneously, we hope the banding device may be applicab e clinically to improving the safety of pulmonary artery banding and debanding procedures in the future.

  • PDF

Cardiac Output Measurement Platform Development Using Swan-Ganz Catheter in Cardiopulmonary Patients with More Accurate (Swan-Ganz Catheter를 이용한 심폐기능 이상자의 정확한 Cardiac Output 측정 플랫폼 개발)

  • Jeong, Yong-Hyun;Na, Sang-Sin;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1591-1597
    • /
    • 2011
  • In this paper, on cardiopulmonary function in the intensive care unit over the direction of the state to define the diagnostic or therapeutic cardiac output Study on Implementation of measures as a platform, Swan-Ganz Catheter with sensor inserted into the body by inserting a saline solution Using temperature change caused by using thermodilution be used to obtain cardiac output. Swan-Ganz Catheter with temperature sensors and pressure sensors and sensor value which is entered through the acquisition more closely if the cardiac output CO, systemic and pulmonary vascular resistance, oxygen consumption and may be able to more accurately calculate the patient's condition than accurate diagnosis and treatment is possible.

Respiratory Assist by Use of Electrical Diaphragmatic Pacing (전기자극에 의한 횡격막 조율을 이용한 호흡보조장치)

  • 오중환;김은기;서재정;박일환;김부연;이상헌;이종국;이영희
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.441-446
    • /
    • 2001
  • Background: Electrical breathing pacing has many advantages over mechanical ventilation. However, clinically permanent diaphragmatic pacing has been applied to limited patients and few temporary pacing has been reported. Our purpose is to investigate the feasibility of temporary electrical diaphragm pacing in explothoracotomy canine cases. Methods: Five dogs were studied under the general anesthesia. Left 5th intercostal space was opened. Self designed temporary pacing leads were placed around the left phrenic nerve and connected to the myostimulator. Chest wall was closed after tube insertion with underwater drainage. Millar catheter was introduced to the aorta and right atrium. Swan-Ganz catheter was introduced to the pulmonary artery. When the self respiration was shallow with deep anesthesia, hemodynamic and tidal volume were measured with the stimulator on. Results: Tidal volume increased from 143.3$\pm$51.3 ml to 272.3$\pm$87.4 ml(p=0.004). Right atrial diastolic pressure decreased from 0.7$\pm$4.0 mmHg to -10.5$\pm$4.7 mmHg(p=0.005). Pulmonary arterial diastolic pressure decreased from 6.1+2.5 mmHg to 1.2$\pm$4.8 mmHg(p<0.001). The height of water level in chest tube to show intrathoracic pressure change was from 10.3$\pm$6.7cmH$_{2}$O to 20.0$\pm$5.3 cmH$_{2}$O. Conclusion: Temporary electrical diaphragmatic pacing is a simple method to assist respiration in explothoracotomy canine cases. Self designed pacing lead is implantable and removable. Negative pressure ventilation has favorable effects on the circulatory system. Therefore, clinical application of temporary breathing pacing is feasible in thoracotomy patients to assist cardiorespiratory function.

  • PDF

Changes of Brain Natriuretic Peptide Levels according to Right Ventricular HemodynaMics after a Pulmonary Resection (폐절제술 후 우심실의 혈역학적 변화에 따른 BNP의 변화)

  • Na, Myung-Hoon;Han, Jong-Hee;Kang, Min-Woong;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young;Choi, Jae-Sung;Yoon, Seok-Hwa;Choi, Si-Wan
    • Journal of Chest Surgery
    • /
    • v.40 no.9
    • /
    • pp.593-599
    • /
    • 2007
  • Background: The correlation between levels of brain natriuretic peptide (BNP) and the effect of pulmonary resection on the right ventricle of the heart is not yet widely known. This study aims to assess the relationship between the change in hemodynamic values of the right ventricle and increased BNP levels as a compensatory mechanism for right heart failure following pulmonary resection and to evaluate the role of the BNP level as an index of right heart failure after pulmonary resection. Material and Method: In 12 non small cell lung cancer patients that had received a lobectomy or pnemonectomy, the level of NT-proBNP was measured using the immunochemical method (Elecsys $1010^{(R)}$, Roche, Germany) which was compared with hemodynamic variables determined through the use of a Swan-Garz catheter prior to and following the surgery. Echocardiography was performed prior to and following the surgery, to measure changes in right ventricular and left ventricular pressures. For statistical analysis, the Wilcoxon rank sum test and linear regression analysis were conducted using SPSSWIN (version, 11.5). Result: The level of postoperative NT-proBNP (pg/mL) significantly increased for 6 hours, then for 1 day, 2 days, 3 days and 7 days after the surgery (p=0.003, 0.002, 0.002, 0.006, 0.004). Of the hemodynamic variables measured using the Swan-Ganz catheter, the mean pulmonary artery pressure after the surgery when compared with the pressure prior to surgery significantly increased at 0 hours, 6 hours, then 1 day, 2 days, and 3 days after the surgery (p=0.002, 0,002, 0.006, 0.007, 0.008). The right ventricular pressure significantly increased at 0 hours, 6 hours, then 1 day, and 3 days after the surgery (p=0.000, 0.009, 0.044, 0.032). The pulmonary vascular resistance index [pulmonary vascular resistance index=(mean pulmonary artery pressure-mean pulmonary capillary wedge pressure)/cardiac output index] significantly increased at 6 hours, then 2 days after the surgery (p=0.008, 0.028). When a regression analysis was conducted for changes in the mean pulmonary artery pressure and NT-proBNP levels after the surgery, significance was evident after 6 hours (r=0.602, p=0.038) and there was no significance thereafter. Echocardiography displayed no significant changes after the surgery. Conclusion: There was a significant correlation between changes in the mean pulmonary artery pressure and the NT-proBNP level 6 hours after a pulmonary resection. Therefore, it can be concluded that changes in NT-proBNP level after a pulmonary resection can serve as an index that reflects early hemodynamic changes in the right ventricle after a pulmonary resection.

Assessment of Parameters Measured with Volumetric Pulmonary Artery Catheter as Predictors of Fluid Responsiveness in Patients with Coronary Artery Occlusive Disease (관상동맥 질환을 가진 환자에서 폐동맥카테터로 측정한 전부하 지표들은 수액부하 반응을 예상할 수 있는가?)

  • Lee, Ji-Yeon;Lee, Jong-Hwa;Shim, Jae-Kwang;Yoo, Kyung-Jong;Hong, Seung-Bum;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.41-48
    • /
    • 2008
  • Background: Accurate assessment of the preload and the fluid responsiveness is of great importance for optimizing cardiac output, especially in those patients with coronary artery occlusive disease (CAOD). In this study, we evaluated the relationship between the parameters of preload with the changes in the stroke volume index (SVI) after fluid loading in patients who were undergoing coronary artery bypass grafting (CABG). The purpose of this study was to find the predictors of fluid responsiveness in order to assess the feasibility of using. certain parameters of preload as a guide to fluid therapy. Material and Method: We studied 96 patients who were undergoing CABG. After induction of anesthesia, the hemodynamic parameters were measured before (T1) and 10 min after volume replacement (T2) by an infusion of 6% hydroxyethyl starch 130/0.4 (10 mL/kg) over 20 min. Result: The right ventricular end-diastolic volume index (RVEDVI), as well as the central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP), failed to demonstrate significant correlation with the changes in the SVI (%). Only the right ventricular ejection fraction (RVEF) measured at T1 showed significant correlation. with the changes of the SVI by linear regression (r=0.272, p=0.017). However, when the area under the curve of receiver operating characteristics (ROC) was evaluated, none of the parameters were over 0.7. The volume-induced increase in the SVI was 10% or greater in 31 patients (responders) and under 10% in 65 patients (non-responders). None of the parameters of preload measured at T1 showed a significant difference between the responders and non-responders, except for the RVEF. Conclusion: The conventional parameters measured with a volumetric pulmonary artery catheter failed to predict the response of SVI following fluid administration in patients suffering with CAOD.

Mechanical Heartworm Removal from 2 Dogs with Caval Syndrome Using Modified Extraction Brushes (카발신드롬에 이환된 2마리의 개에서 modified extraction brushes를 이용한 심장사상충 제거술)

  • Lee, Sungwook;Park, Jonghun;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.30 no.1
    • /
    • pp.36-40
    • /
    • 2013
  • Caval syndrome is a life threatening condition caused by heavy worm burden in right cardiac chambers including right atrium, right ventricle, and vena cava and results in mechanical interference in tricuspid valvular excursion and blood flow to lower pulmonary arteries. A mechanical worm removal is the choice of option for treating this condition in dogs. In this study, we developed a new mechanical worm removal method using modified extraction brushes for treating dogs with caval syndrome. With this newly developed method, we successfully removed heartworms in two dogs with caval syndrome. Although the number of cases applied was small, authors found this method can be a good alternative retrieval method for mechanical worm removal in dogs.

Balloon Valvuloplasty for Congenital Pulmonary Valve Stenosis (풍선 카테터에 의한 폐동맥 판막 성형술)

  • Park, Kook-Yang;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1256-1262
    • /
    • 1990
  • Percutaneous pulmonary valvuloplasty was performed in 19 patients of congenital pulmonary valve stenosis. Pulmonary annulus diameter was estimated by cross sectional echocardiography and right ventricular cineangiography. The size of balloon dilatation catheter was chosen by the same size of the estimated pulmonary annulus in the first 3 patients and 20 \ulcorner30% greater than the annulus in the last 17 patients. After valvuloplasty a satisfactory results was obtained in most patients. Before dilatation, the right ventricular systolic pressure was 91.7 mmHg[range 58-150 mmHg] and it fell to 49.2mmHg[25-85 mmHg] after dilatation. The transvalvular gradient was 67.7 mmHg[33 \ulcorner120 mmHg] before dilatation and it fell to 23.7mmHg [5 \ulcorner62] after dilatation. Repeat cardiac catheterization has been scheduled in all patients 3 months after the initial valvuloplasty but follow up recatheterization was performed in only two patients; in one of them residual gradient of 50 mmHg was reduced to 30 mmHg by repeat valvuloplasty. The other patient showed no evidence of restenosis with transvalvular gradient of 20 mmHg The balloon used for valvuloplasty was single balloon for the first 10 cases and for the later 10 cases it was replaced by Trefoil balloon which was easier for inflation and deflation. There were no significant complications during and after the procedure. From our results, we conclude that balloon valvuloplasty for congenital pulmonary valve stenosis is the treatment of choice in most patients.

  • PDF

Transarterial Coil Embolization in Two Maltese Dogs with Patent Ductus Arteriosus Using a Mini Cobra-tip Angiocatheter (말티스 견에서 시술된 미니코브라 카테터와 코일을 이용한 동맥관 개존증의 치료 2 증례)

  • Han, Dong-Hyun;An, Hyo-Jin;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.740-745
    • /
    • 2010
  • Patent ductus arteiosus (PDA) is the persistent opening of ductus arterious located between pulmonary artery and descending aorta after birth. Although PDA can be occluded by surgical ligation, interventional closure of PDA using various devices is being rapidly replaced to surgical ligation, because of its non-invasive nature of treatment and minimal post-care after treatment. Main problem encountering in interventional treatment in toy breed dogs is vascular inaccessibility due to small size of artery. Although transvenous approach using jugular veins has been developed, this technique requires experienced skill to locate occlude devices into PDA and has high risk of accidental dislodgement of occluding devices (i.e. embolization coils or vascular plugs). Therefore, in this study, we developed a modified technique for coil embolization using mini-angiocatheter with trans-femoral approach in toy breed dogs (< 3.0 kg of body weight). With this modified method, we were successfully treated two toy breed (Maltese) dogs with the left to right shunted PDA.

Fat Embolism Syndrome with Pulmonary Hemorrhage of Unknown Origin (원인을 알 수 없는 폐출혈을 동반한 지방색전 증후군 1예)

  • Jeong, Hye-Cheol;Jung, Ki-Hwan;Kim, Byung-Gyu;Kim, Kyung-Kyu;Lee, Sang-Youb;Park, Sang-Myun;Lee, Sin-Hyung;Shin, Chol;Cho, Jae-Youn;Shim, Jae-Jeong;In, Kwang-Ho;Kim, Han-Gyum;Yoo, Sa-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.3
    • /
    • pp.383-387
    • /
    • 2000
  • Fat embolism syndrome is a rare but serious complication occurring mostly in patients with long bone fractures and occasionally in patients who have had an underlying disease. For example, pancreatitis, diabetes mellitus, alcoholic liver disease and connective tissue disease can be risk factors. The 44-year old woman with a sudden dry cough, blood tinged sputum, and exertional dyspnea visited the Korea University Hospital. Petechiae on her anterior chest wall was found. Chest X-ray and CT showed patchy opacities and multifocal ground-glass opacities in both lung fields. An open lung biopsy demonstrated diffuse pulmonary hemorrhage and intravascular macrovesicular fat bubbles. After conservative management, her symptoms and radiologic findings were significantly improved. A case of fat embolism syndrome without any known risk factors is reported.

  • PDF