• Title/Summary/Keyword: 폐기물소각

Search Result 442, Processing Time 0.023 seconds

A Study on the Emission Characteristics of Mercury in Municipal and Industrial Waste Incinerators (폐기물소각시설의 수은배출특성 연구)

  • Seok Kwangseol;Hong Jihyung;Lee Sukjo;Lee Daegyun;Kim Daigon;Park Jihyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.205-213
    • /
    • 2004
  • The emission characteristics of mercury in waste incinerators were investigated to get basic data for the policy development on the emission reduction of mercury (Hg). For the study several important factors were analysed from 4 incinerators such as mercury concentration, emission factors and removal rate for control devices. The results are listed below. Mercury concentrations in the flue gas were 0.39~5.96 $\mu\textrm{g}$/S㎥ in MWI and 2.5~8.8 $\mu\textrm{g}$/S㎥ in IWI. The distributions of gaseous and particulate mercury in flue gas were above 99% and below 1 %, respectively. Therefore, in order to remove mercury effectively, it is important to control the gaseous mercury. Mercury concentrations in fly ash collected from control device were found as 16.2~35.6 mg/kg- ash in FF of MWI. Also mercury concentrations at the front and back point of control device of MWI were 33.45~62.65 $\mu\textrm{g}$/S㎥ and 0.88~3.49 $\mu\textrm{g}$/S㎥, respectively. Emission factors were estimated as 3.67~11.67 mg/ton in FF, 2.6~24.5 mg/ton in MWI with SNCR, SDR and FF, 54.9~192.7 mg/ton in IWI with Cyclone and FF. Emissions from Municipal Waste Incinerator were found both in minimum and maximum ranges. Annual mercury emissions emitted from MWI was estimated as 20.0 kg (6.0~33.9 kg).

Emission Characteristics of PMs and Heavy Metals from Industrial Hazardous Waste Incinerators (산업 폐기물 소각시설의 입자상 물질 및 중금속의 배출특성)

  • 유종익;이성준;김기헌;장하나;석정희;석광설;홍지형;김병화;서용칠
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.3
    • /
    • pp.213-221
    • /
    • 2002
  • The emission characteristics of particulate matter (PMs) and heavy metals from hazardous industrial wast incinerators were investigated. The particle size distribution (PSD) of PM-10 showed different patterns for two tripes of incinerators; stoker and rotary kiln. However both types showed bimodal form at inlet of air pollution control devices (APCD) and each peak (mode) is located at smaller than 1 ${\mu}{\textrm}{m}$ and near 10 ${\mu}{\textrm}{m}$. It could explain the growth of fine PM by nucleation/coagulation/condensation of metal vapors for fine mode. The PSD of PM-10 after APCD was also influenced by APCD types that had different collection mechanism, and both electrostatic precipitator and bag filter showed less collection efficiency for particles ranged from 0.2 to 0.4 ${\mu}{\textrm}{m}$ and led to a mode in the range of 0.2 to 0.8 ${\mu}{\textrm}{m}$. However the hag filter showed two modes of PSD, while the electrostatic precipitator had one peak. The PMs and heavy metals emission factors, the representative value of emission quantity for sources, for tested facilities were developed. The emission factor of uncontrolled total PM and PM-10 were 14.7 and 7.05 kg/ton waste, respectively. The emission factors from this study were a little bit different with those from US EPA AP-42. It may thus be appropriate to use these results in the course of developing national emission factors.

Characteristics of Hazardous Air Pollutant Emissions from Waste Incinerators (폐기물소각시설의 유해대기오염물질 배출특성 연구)

  • Park, J.M.;Lee, S.B.;Kang, J.G.;Kim, J.P.;Choi, E.S.;Hwang, W.G.;Kwon, O.S.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.183-190
    • /
    • 2007
  • In this study, we have investigated waste incinerators which are one of the major HAPs emission sources. In order to obtain more reliable HAPs emission data from waste incinerators, direct sampling for the possible pollutants from the stack was carried out and the analysis was performed. The purpose of study was to understand the emission status from waste incinerators and recognize the problems and finally to set up a strategy to reduce the HAPs emissions from waste incinerators. The emission concentrations of 8 species of heavy metals and 16 species of PAHs have been analyzed for the first time in Korea. Not only the emission characteristics of HAPs from waste incinerators were identified, but also the analysis of reduction efficiencies for control devices such as BF and wet scrubbing systems was carried out.

Understanding and Improvement of Best Available Techniques for Waste Incineration Facility (폐기물 소각시설 최적가용기법 (BAT) 기준서의 이해와 개선방향)

  • Shin, Sujeong;Park, Jae-Hong;Park, Sang-Ah;Lee, DaeGyun;Kim, Dai-Gon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.533-543
    • /
    • 2017
  • As the public interest in environmental issues increased, the "Act On The Integrated Control Of Pollutant-Discharging Facility" was enacted. Through the integrated environmental pollution prevention act in which 19 industries with large environmental impacts are sequentially applied, pollutants can be managed in a medium-integrated manner and integrated permission of the business unit is possible and BAT can be applied to enable a scientific and proactive environmental management system. In order to facilitate the implementation of integrated environmental pollution prevention act with these advantages, the BAT BREF should be published, modified and revised every 5 years considering the level of scientific development. This study reviewed the issues to be considered in applying BAT and the types of BAT and focused on presenting improvements and development direction when revising and supplementing the standards in the future based on these contents. For this purpose, when revising the standards, it will be necessary to reflect on the domestic situation, to expand the TWG(Technical Working Group) of small-scale workplace experts, and to exchange opinions with business places that have similar processes for each waste type through a systematic total inspection. In addition to these methods, by establishing a resident participation system through information disclosure, it is expected to be used as a guideline for environmental management of business places not subject to integrated permission of less than 3 types as well as those subject to integrated permission.

The Characteristic of NOx Removal Using Catalyst-Corona Discharge (촉매-코로나방전을 이용한 NOx제거 특성)

  • Goh, Hee-Suk;Park, Jae-Yoon;Kim, Jong-Suk;Lee, Soo-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.27-33
    • /
    • 2004
  • The catalytic effect of waterworks sludge on NOx removal in $BaTiO_3$pellets and sludge pellets combined packed-bed plasma reactor with plate-plate electrode geometry is measured for the various conditions. NOx removal rate is about 90[%] at $BaTiO_3$-sludge combined reactor used fresh sludge. $NO_2$ and $O_3$ as byproducts are significantly generated in only $BaTiO_3$ packed-bed plasma reactor, however, in $BaTiO_3$-sludge combined packed-bed reactor, $NO_2$ and $O_3$ are completely removed while $CO_2$ as by-products are observed from FTIR spectra. $NO_2$ and $O_3$ seem to react with metallic molecules, metal oxide, and organic compounds that are generally chlorophyll included in sludge. NOx removal rate increases with $O_2$ concentration increasing. Removal rates $NO_2$ and $O_3$ are independent of operating time and repetition measurement times.

A Study on the Construction of Waste Incineration Facility by Pyrolysis Type in Iksan City (익산시의 열분해방식 폐기물 소각시설 건설에 관한 연구)

  • 육찬남
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.60-66
    • /
    • 2002
  • Iksan city is planning to construct a waste incinerator on the site of about $110,000\textrm{m}^2$ in size that will be selected from a public bid(Oct.~Nov.2002)in the wake of expiration by June 2003 of use for Hamyeol fill-up ground. Science it has usually been difficult to find sites for filling-up or incinerating facilities owing to NIMBY phenomenon, it is badly requested to employ up-to-date technology for processing wastes without environmental pollution. The conflicts between the administrative authorities and community people with regard to construction of incineration facilities, fill-up ground and facilities for waste processing or recycling are not the matters of just today but are increasingly deepening and spreading countrywide. There seems to be no prospect for these conflicts to be amicably settled through dialogues. They rather become a social disease inflicting the whole country like an epidemic. It is therefore believed to be necessary to introduce measures to design and build environment-friendly facilities that may be accepted by residents as not abominable ones but be used as amusing place while they watch the daily operation of them as watchdogs. Iksan city's plan to construct environment-friendly waste incineration facilities of pyrolysis type without chimney has undergone the process of public hearings and explanatory gatherings from every class of Iksan citizens to get consensus but is still delayed due mainly to be the failure of inducing foreign investments. Pyrolysis technology has two advantages ; first, environment-friendly due to less emission of second pollutants ; second, production of by-products highly valuable as resources. It Is known that Germany has recently begun installation and operation of pyrolysis facility urban wastes, an evidence indicating that pyrolysis method will be widely applied to cope with the tightened regulation to preserve environment worldwide.

Feedstock Recycling Technology from Polyester Wastes (폴리에스터 폐자원의 화학 원료화 기술)

  • Jo, Sanghwan;Kim, Gunhyung;Cho, Minjeong;Han, Myungwan;Kang, Kyungsuk
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.17-25
    • /
    • 2014
  • Wide spread application and non-biodegradability of the poly(ethylene terephthalate) generate a huge amount of waste and disposal, posing serious environmental problems. Disposal of the PET wastes also can be thought as an economic loss of valuable chemical resources. We present various ways of feedstock recycling of PET waste to deal with environmental and economic problems. Feedstock recycling is one of promising technologies. It is based on the concept of depolymerizing the condensation polymer such as PET through solvolytic chain cleavage into low molecular products which can be purified and reused as raw materials for the production of high quality chemical products.

An Experimental Study on High Strength Concrete Using the LCD Waste Glass Powder (LCD 폐유리 미분말을 사용한 고강도 콘크리트에 관한 실험적 연구)

  • Kim, Byung-Chul;Cha, Tae-Gweon;Jang, Pan-Ki;Kim, Chan-Woo;Jang, Il-Young
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.4
    • /
    • pp.335-341
    • /
    • 2015
  • Various display devices has been increasing also using waste LCD glass in accordance with the used developed, because circumstances that are most landfill or incineration, are needed research on recycling measure of the using waste LCD glass. Therefore, in this study, to try to assess the basic mechanical properties of concrete mixed with using waste LCD glass micropowder through the room mixed test. According to the study results, the more replacement rate increases, the characteristics of the concrete showed a tendency to decrease slightly. However, according to the small value, it is expected to improve the advanced experimental values by refining the grain size of the materials used to be processed into spheres.

A Study on NOx Removal Efficiency using SNCR Process in the Industrial Waste Incineration Plant (산업폐기물 소각로에서 SNCR공정에 의한 NOx 제거효율에 관한 연구)

  • Ryu Hae-Yeol;Kim Min-Choul;Jung Jong-Hyeon;Lee Gang-Woo;Chung Jin-Do
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.332-339
    • /
    • 2005
  • The environmental regulations in the world has been reinforced and many nations has devoted themselves to the development of cost-effective technology. Selective catalyst reduction(SCR) and selective non-catalyst reduction (SNCR) processes are mainly used to treat nitrogen oxidants generated from fossil-fuel combustion. One of these typical technologies for reduction of do-NOx is SNCR process has increased continuously because of the low cost for building and maintenance. Nevertheless the researches on the application to real scale plant by the reductant like Urea are rarely studied. In this paper, an experimental investigations were performed on the SNCR process in the industrial waste incineration plant. With no reducing agent, the concentration of NOx stayed in around 180 ppm $(O_2\;12\%)$ with the exhausting temperature of $950^{\circ}C$ and changed within the range of 20 ppm to remain relatively consistent. When $10\;wt\%)$ of a solution was added, the efficiency of denitrification reached above $61.4\%$ with the NSR of 2.0 and the exhausting temperature of $950^{\circ}C.$ When the concentration of the urea solution was set to $10\;wt\%$ and the sprinkling to four nozzles, the reaction temperature was reduced to about $50~100^{\circ}C$ with a mixture of $10\;wt\%\;CH_3OH\;and\;5wt\%\;Na_2CO_3$ in $40\;wt\%$ of the solution. The NOx removal efficiency increased to $78.4\%,$ achieving a broader and expansive range of reaction temperatures than the addition of an unmixed pure solution.

Preparation of a CRM for QA/QC in dioxin analysis and inter-laboratory study (다이옥신 정도 관리용 CRM 제조와 실험실간 비교평가)

  • Yu, Byeong-Woon;Moon, Young-Hoon;Kim, Min-Kwan;Kyoung, Jong-Dai;Chang, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.153-162
    • /
    • 2004
  • Dioxin CRM for QA/QC was prepared with fly ash collected from municipal waste incinerator. With that CRM inter-laboratory test was carried out. The collected fly ash was conducted several homogeneity steps including sievings and mixing. Homogeneity test and estimation of uncertainty was performed by one-way ANOVA based on ISO guide 35. Compared concentrations of fly ash of participants to CRM values, PCDDs value was lower than that of CRM in almost participants, and showed higher PCDFs concentration than that of CRM. Although there is a small difference in PCDD/Fs concentrations with congeners of extract, the result was close to mean value.