• Title/Summary/Keyword: 평형인자

Search Result 165, Processing Time 0.034 seconds

Diurnal Variations of Equilibrium Factor and Unattached fraction of Radon Progeny in Some Houses and Laboratories (가옥 및 실험실내 라돈평형인자, 비 흡착 라돈자손 비율의 일일 변동 특성)

  • Lee, Seung-Chan;Kim, Chang-Kyu;Lee, Dong-Myung;Kang, Hee-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.399-408
    • /
    • 2001
  • The variation characteristics of radon concentration, equilibrium equivalent concentration and equilibrium factor in some houses and laboratory buildings have been studied. The variation of equilibrium factor and the unattached fraction of radon progeny with ventilation condition have been also estimated. The averages of radon concentration, equilibrium equivalent concentration and equilibrium factor were $30\;Bq\;m^{-3},\;19.6\;Bq\;m^{-3}$ and 0.65 in seven houses, while $55.0\;Bq\;m^{-3},\;31.9\;Bq\;m^{-3}$ and 0.58 in three laboratory buildings, respectively. The diurnal variation of radon concentration, equilibrium equivalent concentration and equilibrium factor in indoor showed a typical pattern that the radon concentration, equilibrium equivalent concentration and equilibrium factor increased at dawn and morning, while decreased at midday and evening. While the equilibrium factor rate deceased in the indoor environment which was well ventilated, the unattached traction of radon progeny increased. The equilibrium factor was in proportion to air pressure and humidity of indoor, whereas in Inverse proportion to temperature.

  • PDF

Study on the Improvement of Ballast Water Risk Assessment of GloBallast (GloBallast 선박평형수 위해도평가 방법의 개선방안에 관한 연구)

  • Lee, S.G.;Kang, W.S.;Kim, E.C.;Shin, K.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.4
    • /
    • pp.224-229
    • /
    • 2011
  • Recently, the management of the marine invasive alien species introduced by ballast water has come to the core as an urgent task. Because, hazardous organisms cause harmful effects on the ecosystem. Hazardous organisms also negatively affect fisheries, commercial shipping activities, and marine resources. In this regard, IMO used to operate GloBallast, Ballast Water Risk Assessment System, in order to manage the introduction of invasive species by ballast water. GloBallast is constructed to assess the relative risk due to the movement of ballast water between nations, using the volume and the number of times of ballast water discharge, the environmental similarity between ports, and the abundance of hazardous species as the main factors. According to the results of the demo-operation of GloBallast, it was found out that the environmental similarity factor had affected most highly the results of risk assessment. Therefore, in this study, the correlation between the main factors used in GloBallast risk assessment were re-examined, and some methods were suggested in order to reflect these main factors in the risk assessment more reasonable.

The short and long term radon concentration and its radioactive equilibrium factor at subway line in Seoul (서울 지하철 역사내에서의 장단기 라돈농도와 방사평형 인자의 적용)

  • 김민영;하광태;전재식;신재영;박영웅
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.79-79
    • /
    • 2001
  • 최근 서울의 각 지하철역에서의 라돈농도 측정결과가 각 일간지 및 방송에 보도되면서 서울시의회업무 보고 및 국정감사에서도 중요한 이슈의 하나로 부각되었다. 라돈에 관한 미환경청(USEPA)의 규제치(action level)는 4pCi/L이며 이때의 방사평형인자는 0.5로 되어있다. 서울시에서는 2000년도에 195개소 즉 175개역사와 20개소의 환승통로에 대한 라돈농도에 대한 장단기농도 측정과 1999년도에는 라돈자핵종을 분석하여 이를 바탕으로 라돈방사평형인자를 구한바 있다. (중략)

  • PDF

KALIMER 우라늄금속핵연료노심의 평형주기 설계인자 변경 연구

  • 김상지;김영인;김영진;박창규
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.64-69
    • /
    • 1998
  • KALMER 우라늄 금속핵연료노심의 평형주기에 대하여 주기길이, 농측도, 중식비의 관점에서 설계인자 변경에 따른 변화를 분석하였다. 유효노심높이, 반경방향 블랑캣의 batch수, 개스팽창모듈(GEM)의 적용성, 노용기내핵 연료저장(IVS)의 사용. 핵연료핀의 직경 증가 둥에 대한 설계 변경이 고려되었다. 본 연구결과를 통하여, 평탄화된 출력분포 및 핵연료의 이용도 향상을 기하면서 설계변경이 타 분야에 미치는 영향을 최소화하고 본래 KALMER의 안전성을 유지하고자 핵연료핀의 직경을 증가시킨 fat pellet 설계방안을 채택하였다

  • PDF

Analysis on Heat Loss of Hybrid Safety Injection Tank to Predict Pressure Equalizing Time (혼합형 안전주입탱크의 압력평형 예측을 위한 열손실 평가)

  • Kim, Myoung Jun;Ryu, Sung Uk;Kim, Jae Min;Park, Hyun-Sik;Yi, Sung-Jae
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.71-77
    • /
    • 2017
  • In the event of loss of coolant accident (LOCA) and station black out (SBO) in the primary system of a nuclear reactor, the coolant water should be injected to reactor coolant system (RCS) without any intervention of operators or active components. To satisfy the requirements, hybrid safety injection tank (Hybrid SIT) was suggested by Korea Atomic Energy Research Institute (KAERI). The pressure equalizing time of Hybrid SIT is an important parameter to determine the timing of coolant injection. To predict the pressure equalizing time of the Hybrid SIT, a separate effect test facility was constructed and sensitivity tests were conducted in various conditions. The main parameter determining the pressure equalizing time was obtained from separate effect test (SET) results. The wall of condensation on the inner wall of SIT and direct contact condensation on the water surface affected to the pressure equalizing time very much. In this study, the effect of each condensation phenomena on pressure equalizing time was quantitatively analyzed from results of SET and a prediction method of pressure equalizing time was proposed.

Effective Dose Equivalent due to Inhalation of Indoor Radon-222 Daughters in Korea (한국인의 라돈-222 자핵종 호흡 실효선량당량 평가)

  • Chang, Si-Young;Ha, Chung-Woo;Lee, Byoung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.1-13
    • /
    • 1991
  • Effective dose equivalents resulting from inhalation of indoor radon-222 daughters at 12 residential areas in Korea were assessed by a simple mathematical lung dosimetry model based on the measurements of long-term averaged radon concentrations at 340 dwellings. The long-term averaged indoor radon-222 concentrations and corresponding eqilibrium equivalent radon $concentration(EEC_{Rn})$ measured by passive time-integrating CR-39 radon cups are in the range of $33.82{\sim}61.42Bq/m^3(median\;:\;48.90Bq/m^3)$ and of $13.53{\sim}24.57Bq/m^3(median\;:\;19.55Bq/m^3)$, respectively. The effective dose equvalent conversion factor for the exposure to unit $EEC_{Rn}$ derived in this study was estimated $1.07{\times}10^{-5}mSv/Bq\;h\;m^{-3}$ for a reference adult and agreed well with those recommended by the ICRP and UNSCEAR. The annual average dose equivalent to the lung $(H_{LUNG})$ from inhalation exposure to measured $EEC_{Rn}$ was estimated to be 20.90 mSv and resulting effective dose $equivalent(H_E)$ was to be 1.25 mSv, which is about 50% of the natural radiation exposure of 2.40 mSv/y to the public reported by the UNSCEAR.

  • PDF

Analysis on Variation Mechanism of the Plasma Process Using OES (광진단을 통한 플라즈마 공정 상태 변동 메커니즘 분석)

  • Park, Seol-Hye;Kim, Gon-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.31-31
    • /
    • 2011
  • 식각, 증착 등의 플라즈마 활용 공정에서 공정 결과들이 예상치 못한 편차를 보이거나 시간에 따른 공정 결과의 드리프트가 발생하는 등의 문제는 공정 수율 향상 뿐 아니라 공정 결과 생산하게 되는 제품의 성능을 결정짓는다는 점에서 중요하다. 그 결과 공정의 이상이 발생 되는 것을 감지하기 위한 다양한 장치 및 알고리즘들이 등장하고 있으나, 현재 공정 상태 변화를 진단하는 것은 공정 장치에서 발생된 신호 변동을 통계적으로 처리하는 수준에 머무르거나 플라즈마 인자들의 값 자체를 진단하는 정도에 그치고 있다. 본 연구에서는, 향후 물리적 해석을 기반으로 한 공정 진단을 위한 알고리즘을 세우는 것을 목표로 하여 공정 결과에 민감하게 영향을 주는 플라즈마 내부 전자의 열평형 상태의 미세한 변동을 감지하고 이를 통하여 공정 결과에 영향을 주게 되는 장치 내 물리적, 화학적 반응들의 변동 메커니즘을 이해하고자 하였다. 외부에서 감지하기 힘들기 때문에 장치 상태에 변동이 없는 것으로 보이지만 실제로는 변동하고 있는 플라즈마의 미세한 상태 변화를 보여줄 수 있는 물리 인자로는 잦은 충돌로 인하여 빠르게 변동에 대응할 수 있는 전자들의 열평형 특성을 살펴보는 것이 적합하다고 판단하여 광신호를 통해 전자 에너지 분포함수를 진단할 수 있는 모델을 수립하였다. 이 모델의 적용 결과를 활용하면 전자들의 열평형이 주변 가스 종의 반응율 변동에 주게 되는 영향을 해석할 수 있다. 실제로 ICP-Oxide Etcher 장치에서 장치 내벽 오염물질 유입 및 공정 부산물의 장치 내 잔여로 인하여 식각율로 표현되는 공정 결과에 최대 6%의 편차가 발생하게 되는 메커니즘을 해석할 수 있었다.

  • PDF

활성탄 검출기를 이용한 실내 라돈농도 측정

  • 조찬희;신상운;손중권
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.589-593
    • /
    • 1998
  • 활성탄 검출기를 이용하여 실내 라돈농도를 측정하였다. 라돈농도 측정을 위한 활성탄 검출기의 노출기간은 4일, 5.8일, 5일이었다. 측정결과 사무실내 라돈농도는 각각 1.63 pCi/$\ell$, 1.23 pCi/$\ell$, 1.76 pCi/$\ell$였으며, 측정기간 동안 평균 1.54 pCi/$\ell$였다. 이 결과는 미국 환경보호청에서 제시한 조치준위의 최저치인 4 pCi/$\ell$ 이하였다. 같은 장소에서 WL Meter를 이용하여 라돈 딸핵종의 농도를 축정한 결과, 각각 5. 64 mWL, 4.88 mWL, 6.43 mWL이었다. 라돈과 라돈 딸핵종 농도로부터 라돈평형인자 값을 산출한 결과 각각 0.34, 0.39, 0.36으로, 이 결과는 다른 방법에 의해 타 연구자가 측정한 기존의 사무실내 라돈농도 및 라돈평형인자 산출결과와 비교적 유사했다. 따라서 활성탄 검출기를 이용한 라돈농도 측정법은 매우 유용한 방법임을 확인할 수 있었다.

  • PDF

Numerical Analysis of MHD Equilibrium in Tokamaks by Finite Element Method. (유한요소법에 의한 토카막에서 MHD평형의 수치해석)

  • 이홍식;황기웅
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.9
    • /
    • pp.733-739
    • /
    • 1989
  • Fixed boundary MHD static equilibrium for the axisymmetric toroidal plasma is analyzed numerically. The Grad-Shafranov equation is solved using finite element method. The toroidal current term is expressed by plasma pressure and toroidal field function. The numerical results are compared to the Solovev analytic equilibrium for the verification of the solution. For SNUT-79 tokamak device in Seoul National University, the flux surfaces, the toroidal current profiles, the safety factor q and average beta values are obtained when the p and g profiles are varied.