• 제목/요약/키워드: 평행류 응축기

검색결과 6건 처리시간 0.017초

자동차용 평행류 응축기의 열성능 모델링 (Thermodynamic Modeling of Parallel Flow Condenser for Automotive Air Conditioning System)

  • 김일겸;고재윤;박상록;임장순
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.771-779
    • /
    • 2001
  • In this study, a simulation program has been developed to predict the performance of a parallel flow condenser of an air conditioning system for an automobile. The well-known correlations for he heat transfer rates and the pressure drops are included in this model. It is fond that the numerical model can predict the heat transfer rate and the pressure drop accurately. As the condensing pressure increases of fixed air inlet temperature, the heat transfer rate increases and the pressure drop decreases. The effect of he degree of subcooling on the performance of the condenser is greater than that of the degree of super-heating because the ratio of the area occupied by he tow-phase refrigerant the total area is significantly affected by he degree of subcooling rather than the degree of superheating.

  • PDF

자동차 에어컨용 평행류 응축기의 성능평가 (Performance Evaluation of a Parallel Flow Condenser for Automotive Air Conditioners)

  • 장혁재;강병하
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.247-253
    • /
    • 2003
  • The new shape of louver-fin has been applied to a parallel flow condenser to enhance air-side heat transfer rate lot an automotive air-conditioner R- l34a is employed as a refrigerant inside the flat tube of the condenser, This problem is of particular interest in reducing the geometric size of the automotive air conditioner The effect of air flow rate on pressure drop as well as heat transfer in air side are studied in detail. Comparison of the performance is also made with that of a conventional parallel flow condenser, which is available in the market. The results obtained indicate that the total pressure drop through the pre sent condenser is not changed, while the heat transfer rate is increased by 24% at high veto city of air flow, compared with those of the conventional condenser. The parallel flow condenser with a new shape of louver-fin could be reduced in size by 20% for the equivalent condenser capacity, compared with the conventional parallel flow condenser.

R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구 (An experimental study on the performance of a window system air-conditioner using R407C and R410B)

  • 김만회;신정섭;김권진
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

핀-튜브 열교환기와 알루미늄 열교환기의 전열성능과 압력강하 특성비교 (Comparison of Heat Transfer Performance and Pressure Drop of Fin-Tube and Aluminum Heat Exchangers)

  • 장근선;이현수;김재덕
    • 한국산학기술학회논문지
    • /
    • 제10권2호
    • /
    • pp.222-229
    • /
    • 2009
  • 본 논문에서는 루버형 핀 형상을 가진 핀-튜브 열교환기와 알루미늄 평행류 열교환기의 에어컨 응축기 조건에서의 열전달 성능과 공기측 압력강하 특성을 비교하였다. 모든 실험은 ASHRAE 표준에 근거해 제작된 공기엔탈피형 칼로리미터를 사용하여 수행하였다. 관외 측 공기 속도는 0.7-1.6 m/s까지 0.3 m/s 간격으로 변화시켰으며 건구온도는 $20^{\circ}C$, 상대습도는 60%로 유지하였다. 관내 측 물의 입구온도는 $70^{\circ}C$, 유량은 10 LPM로 고정하였다. 알루미늄 열교환기의 열전달 성능은 루버 핀-튜브 열교환기보다 단위체적당, 단위질량당, 단위열전달면적당 약 17-163%정도 높게 나타나는 연구결과를 보였으며 반면에 공기측 압력강하는 핀-튜브 열교환기에 비해 약 19-81% 정도 낮게 나타났다.