• Title/Summary/Keyword: 평판 검출기

Search Result 61, Processing Time 0.03 seconds

Fabrication and Characterization of High Performance Planar Photodetectors on QW-FET Wafer (QW-FET 구조를 가진 고성능 평판형 광검출기의 제작 및 특성평가)

  • Cho, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2300-2302
    • /
    • 2005
  • Metal-Semiconductor-Metal type photodetector was fabricated with AlGaAs/InGaAs Quantum Well FET structures using simplified processing steps. The DC and RF responses were measured by 850nm wavelength injection laser. A DC responsivity in the quasisaturated regime was 0.45 A/W in CW measurements, and a bandwidth measured using a 850nm 40 ps pulsed laser was 16GHz. An electrical equivalent circuit model was extracted from measured S-parameter.

  • PDF

종계의 생산성 향상을 위한 질병.위생 관리

  • 송창선
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2003.05a
    • /
    • pp.73-82
    • /
    • 2003
  • 본 연구에서는 국내 종계의 생산성 저하요인들을 평가·분석하였으며, 국내사육 종계의 실질적인 생산성을 극대화 시킬 수 있는 방안을 제시하고자 시험을 수행하여 다음과 같은 결론을 얻었다. 1. 혈청검색에 의한 품종별 종게군 질병 모니터링을 실시 한 결과, SE, MS 등 2종의 난계대성 세균성 질병과 REV, APV, CAV, ORT, REO 등 5종의 만성소모성 질병을 유발하는 질병이 종계군의 산란기에 감염되어 이들이 단독 또는 중복감염되어 나타나는 피해가 예상되었으며, 이들의 감염을 효과적으로 예방 할 수 있는 백신의 개발 및 도입의 필요성이 대두되었다. 2. 집중관리 모니터링 대상농장에 대한 ND, IB, IBD 등 3종의 생독백신에 대한 접종효능을 평가해 본 결과 산란종계, 육용종계를 막론하고 전반적으로 니플급수기를 이용한 음수접종법 적용시 5주령 이하 계군에 2내지 3회의 음수접종을 실시하였음에도 불구하고 항체가 거의 형성되지 못하거나 매우 불균일한 면역반응이 나타나는 것으로 조사되어 국내 야외농장에 대한 분무접종 유도 등 기존의 백신접종법에 대한 시급한 개선대책 마련이 요구되었다. 3. 육성기 및 산란기 종계 질병·위생관리 프로그램 확립을 위하여 ND, IB, IBD에 대한 개선된 백신접종 프로그램을 모델계군에 적용한 후, 주령별로 생독백신 접종효능을 조사한 결과 백신접종 후 ND, IB, IBD에 대한 평균 항체가와 항체의 균일도 (%CV)가 표준 목표치 이상 상승하여 개선의 효과를 볼 수 있었다. 4. 산란기 종계 질병·위생관리 프로그램 확립을 위하여 실시된 변이형 IB에 대한 방어능 시험결과 정기적인 Mass type IB 생독백신의 분무접종은 국내 유행 호흡기형 IBV 유전형 VI에 대한 방어효과는 다소 떨어지는 것으로 조사되어 국내분리주를 이용한 IB 생독백신의 개발이 요구되었다. 5. 종계장 살모넬라 및 마이코플라즈마 조기 검출을 위하여 실시한 종계장 살모넬라 및 마이코플라즈마 환경 모니터링 실시 결과 기존의 평판응집반응이나 ELISA에 의한 혈청검색법에 비하여 검출효율이 매우 높은 것으로 조사되어 향후 국내 종게군에 대한 살모넬라 및 마이코플라즈마 조기검출과 방제연구에 큰 도움이 될 것으로 사료되었다.

  • PDF

High-Speed, High-Reliability Planar-Structure InP/InGaAs Avalanche Photodiodes for 10Gb/s Optical Receivers with Recess Etching (수광영역의 식각을 통한 단일확산 공정의 고속 평판형 InP/InGaAs 10Gb/s 광 검출기의 신뢰성)

  • Jung, Ji-Houn;Kwon, Yong-Hwan;Hyun, Kyung-Sook;Yun, Il-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1022-1025
    • /
    • 2002
  • This paper presents the reliability of planar InP/InGaAs avalanche photodiodes (APD's) with recess etching, which is very crucial for the commercial 10-Gb/s optical receiver application. A versatile design for the planar InP/InGaAs APD's and bias-temperature tests to evaluate long-term reliability at temperature from 200 to $250^{\circ}C$. The reliability is examined by accelerated life tests by monitoring dark current and breakdown voltage. The lifetime of the APD's is estimated by a degradation activation energy. Based on the test results, it is concluded that the planar InP/InGaAs APD's with recess etching shows the sufficient reliability for practical 10-Gb/s optical receivers.

  • PDF

Design and Fabrication of HgI2 Sensor for Phosphor Screen based flat panel X-ray Detector (형광체 스크린 기반 평판형 X선 검출기 적용을 위한 요오드화수은 필름 광도전체 센서 설계 및 제작)

  • Park, Ji Koon;Jung, Bong Jae;Choi, Il Hong;Noh, Si Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.189-194
    • /
    • 2014
  • In this study, from a new x-ray detector that combines a columnar CsI:Na scintillation layer with a photosensitive mercuric iodide layer was investigated. In this structure, X-rays are converted into visible light on a thick CsI:Na layer, which is then converted to electric charges in a thin $HgI_2$ bottom layer. The thin coplanar mercuric iodide films as a photosensitive converter requiring only a few tens of volts of bias, associated with a thick columnar coating of phosphor layer, were simulated and designed. The results of this research suggest that the new coplanar x-ray detector with a hybrid-type structure can resolve the following problems: high voltage from the a-Se, and low conversion efficiency from the indirect conversion method. The results of this research suggest that the new CsI:Na/$HgI_2$ x-ray detector with a double-layer type structure can resolve the following problems: high voltage from the direct conversion method, and low conversion efficiency from the indirect conversion method.

Detecting Characteristics of Ultrasonics Generated by Partial Discharge in Insulating Oil Using the Optical Fiber Mach-Zehnder Interferometer (광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성)

  • 이상훈;심승환;이광식;김달우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.50-56
    • /
    • 2003
  • It is well known that a partial-discharge(PD) in insulation oil is the source of various physical and chemical phenomena, such as heat, light, gas, chemical transformation, electric current, electromagnetic radiation and ultrasonics. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Ultrasonic-wave detection is a useful method for the diagnosis of the transformer-insulation condition. Conventionally, ulyrasonic waves are detected by Piezo-electric transducer, but we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

Dose Reduction According to Geometric Parameters of Digital Cerebral Angiography (두개부 혈관 조영검사 시 기하학적 특성에 따른 선량 감소 방안)

  • Park, Chan Woo;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.399-406
    • /
    • 2019
  • This study aims to find geometric parameters that the radiologist can change from time to time to reduce dose in angiography examinations. Depending on the geometric characteristics, the values calculated by effective dose were compared, while filming in fluoroscopy mode and Digital subtraction angiography, respectively. The study found that the lower the dose was in FPS mode, the lower the dose was reduced to 30-40%. Doses according to the X-ray angle were measured highest in AP View and lower as the angle went in the head direction. The greater the FOV, the higher the dose was 1.2-1.6 times, and the closer the distance between the X-ray tube and the table, the greater the dose was about 10%. Source-image intensifier distance (SID) get longer to 100 mm, dose of each fluoroscopy and Digital subtraction angiography increase up to 25-30%. In conclusion, various geometric characteristics in angiography examinations are parameters that can be applied by radiographers as frequently as possible, and appropriate geometric properties can be considered and applied in various situations, resulting in appropriate dose reduction.

Development of a Portable ELF Electric Field Meter (휴대용 극저주파 전장측정기 개발)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Il-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.120-126
    • /
    • 2000
  • This paper dealt with the developed portable electric field meter which consisted of planar-type sensor, analog amplifier with gain controller, A/D convertor, and display unit. The principle of the planar-type sensor for detecting time-varying electric field of extremely low frequency (ELF) bandwidth was described, and a calibration system using cylindrical guard electrodes and parallel-plate electrodes was proposed. From the calibration experiment, the frequency bandwidth and the sensitivity of the developed electric field meter was $17[Hz]{\sim}7[kHz]$, and 4.45[mV/V/m], respectively. Also it can measure the electric field strength up to 10[kV/m], and the measured result was displayed on the liquid crystal display in digit. The electric field meter can be widely applied to measure electric field strength radiated from power lines, computers, and home appliances such as hair dryer, heater, etc.

  • PDF

Development of X-ray Image Processing Technology for Nondestructive Measurement of the Coating Thickness in the Simulated TRISO-coated Fuel Particle (모의 TRISO 핵연료입자 코팅층 두께 비파괴 측정을 위한 X-선 영상처리기술 개발)

  • Kim Woong-Ki;Lee Young-Woo;Park Ji-Yeon;Ra Sung-Woong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.669-672
    • /
    • 2006
  • 고온가스냉각 원자로에서는 고온 안정성 및 핵분열생성물 차단 성능이 우수한 TRISO(tri-tsotropic) 핵연료를 사용하고 있다. TRISO 핵연료 입자는 직경이 약 1 mm인 구 형태로 입자의 중심에는 직경 $0.5{\mu}m$의 핵연료 커널(kernel)이 포함되며 커널 외곽을 코팅 층이 에워싸고 있다. 이 코팅 층은 완충(buffer) PyC(pyrolytic carbon) 층, 내부 PyC 층, SiC 층, 그리고 외부 PyC 층으로 구성되어 있다. 각 코팅 층의 두께는 수십${\sim}$${\mu}m$ 범위이며, 본 연구에서는 각 코팅 층의 두께를 비파괴적으로 측정하기 위하여 마이크로포커스 X-선 발생장치와 고해상도 X-선 평판(flat panel) 검출기로 구성된 정밀한 X-선 래디오그래피 장치를 구성하고, $UO_2$ 핵물질 대신에 $ZrO_2$를 커널로 사용한 모의 TRISO 핵연료 입자에 대한 래디오그래피 영상을 획득한 후 디지털 영상처리기술을 이용하여 코팅 층 사이의 경계선이 구분 가능하도록 영상을 개선하고 디지털 영상처리 알고리즘을 개발하여 코팅 층의 두께를 측정하였다.

  • PDF

A Performance Evaluation of Diagnostic Display System by AAPM TG18 (AAPM TG18에 의한 진단용 CRT 디스플레이 시스템의 성능 평가)

  • Kim, H.J.;Jung, H.J.;Min, D.K.;Hong, J.O.;Kim, Y.N.
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.6 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • 디지털 영상 검출기와 디스플레이 기술의 발달과 의료영상전달시스템(PACS)의 출현은 전통적 필름방식에 비하여 디지털 방식으로 방사선과 영상을 획득하고 전송, 저장하는 매우 효과적인 수단을 제공하고 있다. 2002년 8월, 연세의료원 세브란스병원은 진단 영상 판독 목적으로 18 대의 CRT(Braco View, Belgium)와 32대의 평판 LCD(Totoku Electric Co., Ltd., Japan) 디스플레이 장치를 GE full-PACS(GE 메디칼시스템코리아 : GEMSK)와 연계하여 설치 완료하였다. 본 연구에서, 기하학적 왜곡, 반사, 휘도 반응, 휘도 균일도, 분해능, 노이즈,베일링 글레어, 칼라 균일도 항목들을 AAPM TG18 보고서 9.0에 따라서 시각적 그리고 부분적으로는 정량적인 방법으로 인수검사를 실시하여 보고한다. 사용된 장비는 색도계로도 사용되는 간편한 휘도계, TG18 테스트 패던, AAPM Tg18 AT plug-in software(Barco View Ltd., Kortrijk, Belgium)이었다. 칼라 균일도를 제외한 모든 테스트 결과는 AAPM TG18에서 권고하는 기준에 일치하였으며 진단 영상 판독에 사용하기에 전적으로 수락할 수 있는 성능이었다. 결론으로, 사용된 인수검사는 단지 인수 검사 표준을 제공하는 것 뿐만 아니라 품질검사(QC)의 지침, 판독 환경의 최적화 그리고 교체 시기나 업그레이드 시기를 결정하여주는 중요한 역할을 할 수 있을 것이다.

  • PDF