A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.

Topoclimatological interpretation of the daily air temperature minima at 17 locations crossing over Yangpyeong basin in 1986 spring (봄철 양평지역(楊平地域)의 지형(地形) 및 고도(高度)에 따른 일최저기온(日最低氣溫)의 분포(分布))

  • Kang, An-Seok;Yun, Jin-Il;Jung, Yeong-Sang;Tani, No Bureru
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.19 no.4
    • /
    • pp.339-344
    • /
    • 1986
  • Frost damage which can reduce yields, impair fruit quality and cause loss of trees is closely related to the occurrence of daily minimum temperature. Horizontal distribution of air temperature minima can be characterized by conditions of radiational cooling and gravitational movement of cold air, which are influenced by the regional topographic features. Observations were made on the air temperature minima over Yangpyeong area, to delineate potential effects of topography on the temperature pattern during spring season. Two routes were selected for the observation. Liquid glass minimum thermometers were installed at 17 sites through the old peach orchards which had been closed due to the frequent freeze-frost hazards during the recent years. This route was 8.5km long and the highest point was 350m above mean sea level. The other route, which was 2.5km in distance, was run with a digital resistance thermometer during the hour just before sunrise. Observations were made both on a calm-clear day (April 30, 1986) and a windy-overcast day (May 1, 1986). The temperature on April 30 was in increasing trend with elevation but this was modified at near the riverside and the downtown area. An orchard lying on a hilltop showed the temperature $1^{\circ}C$ higher than near by lowland of which elevation was about 30m lower. The minimum temperature on the overcast day was little affected by terrestrial conditions but by the atmospheric lapse condition. The peach orchards severely damaged by cold air were found in the area where the lowest minimum temperature was observed. The results may be useful for selection of the proper orchard location to be developed in an area.

  • PDF

Thallium-201 SPECT in the Evaluation of Postoperative Tumor Recurrence on the Chest Wall in Lung Cancer (폐암 수술 후 흉벽의 종양 재발 검출에 있어 Tl-201 폐 SPECT의 유용성)

  • Ryu, Young-Hoon;Kim, Hyung-Jung;Ahn, Chul-Min;Kim, Se-Kyu;Paik, Hyo-Chae;Lee, Doo-Yun;Chung, Kyung-Young;Yune, Min-Jin;Park, Sang-Jung;Moon, Sung-Wook;Kim, Sang-Jin;Lee, Jong-Doo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.542-549
    • /
    • 2002
  • Purpose : The purpose of our study was to assess the usefulness of the Tl-201 SPECT for the detection of the postoperative tumor recurrence on chest wall. Methods: 28 patients including 14 with suspected recurrence of tumor in the chest wall on postoperative chest cr scan, 10 with postoperative pleural effusion which proved benign on radiologic, cytologic and laboratory findings, and 4 with chronic tuberculous empyema as control group were included. All patients underwent SPECT 30 minutes and 4 hours after intravenous injection of 111MBq of Tl-201. Tumor uptake was visually graded by two interpreters and scored as follows : no uptake:0, similar to contralateral lung: 1, higher than contralateral lung but less than heart:2 and similar to heart:3. Results : Markedly increased (grade 3 or 2) Tl-201 uptake was noted in patients with suspected recurrence of tumor in the chest wall (13/14) whereas no (8/10) or minimal (2/10) uptake along the collapsed lung in patients with postoperative benign pleural effusion. In two patients, Tl-201 SPECT revealed additional recurrent tumor mass lesions that were barely perceptible on chest cr scan. Patients with chronic tuberculous empyema showed relatively smoothly marginated increased uptake along the chest wall 4/4), but lesser in degree (grade 1 or 2), when compared to recurrent tumor uptake. Conclusion : Tl-201 lung SPECT seems to be useful to detect postoperative tumor recurrence on chest wall and to differentiate malignant from benign pleural effusion and may provide additional information to the morphologic data obtained by CT.

Helicopter Pilot Metaphor for 3D Space Navigation and its implementation using a Joystick (3차원 공간 탐색을 위한 헬리콥터 조종사 메타포어와 그 구현)

  • Kim, Young-Kyoung;Jung, Moon-Ryul;Paik, Doowon;Kim, Dong-Hyun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.3 no.1
    • /
    • pp.57-67
    • /
    • 1997
  • The navigation of virtual space comes down to the manipulation of the virtual camera. The movement of the virtual cameras has 6 degrees of freedom. However, input devices such as mouses and joysticks are 2D. So, the movement of the camera that corresponds to the input device is 2D movement at the given moment. Therefore, the 3D movement of the camera can be implemented by means of the combination of 2D and 1D movements of the camera. Many of the virtual space navigation browser use several navigation modes to solve this problem. But, the criteria for distinguishing different modes are not clear, somed of the manipulations in each mode are repeated in other modes, and the kinesthetic correspondence of the input devices is often confusing. Hence the user has difficulty in making correct decisions when navigating the virtual space. To solve this problem, we use a single navigation metaphore in which different modes are organically integrated. In this paper we propose a helicopter pilot metaphor. Using the helicopter pilot metaphore means that the user navigates the virtual space like a pilot of a helicopter flying in space. In this paper, we distinguished six 2D movement spaces of the helicopter: (1) the movement on the horizontal plane, (2) the movement on the vertical plane,k (3) the pitch and yaw rotations about the current position, (4) the roll and pitch rotations about the current position, (5) the horizontal and vertical turning, and (6) the rotation about the target object. The six 3D movement spaces are visualized and displayed as a sequence of auxiliary windows. The user can select the desired movement space simply by jumping from one window to another. The user can select the desired movement by looking at the displaced 2D movement spaces. The movement of the camera in each movement space is controlled by the usual movements of the joystick.

  • PDF

A Pilot Study for the Remote Monitoring of IMRT Using a Head and Neck Phantom (원격 품질 보증 시스템을 사용한 세기변조 방사선치료의 예비 모니터링 결과)

  • Han, Young-Yih;Shin, Eun-Hyuk;Lim, Chun-Il;Kang, Se-Kwon;Park, Sung-Ho;Lah, Jeong-Eun;Suh, Tae-Suk;Yoon, Myong-Geun;Lee, Se-Byeong;Ju, Sang-Gyu;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.249-260
    • /
    • 2007
  • Purpose: In order to enhance the quality of IMRT as employed in Korea, we developed a remote monitoring system. The feasibility of the system was evaluated by conducting a pilot study. Materials and Methods: The remote monitoring system consisted of a head and neck phantom and a user manual. The phantom contains a target and three OARs (organs at risk) that can be detected on CT images. TLD capsules were inserted at the center of the target and at the OARs. Two film slits for GafchromicEBT film were located on the axial and saggital planes. The user manual contained an IMRT planning guide and instructions for IMRT planning and the delivery process. After the manual and phantom were sent to four institutions, IMRT was planed and delivered. Predicted doses were compared with measured doses. Dose distribution along the two straight lines that intersected at the center of the axial film was measured and compared with the profiles predicted by the plan. Results: The measurements at the target agreed with the predicted dose within a 3% deviation. Doses at the OARs that represented the thyroid glands showed larger deviations (minimum 3.3% and maximum 19.8%). The deviation at OARs that represented the spiral cord was $0.7{\sim}1.4%$. The percentage of dose distributions that showed more than a 5% of deviation on the lines was $7{\sim}27%$ and $7{\sim}14%$ along the horizontal and vertical lines, respectively. Conculsion: Remote monitoring of IMRT using the developed system was feasible. With remote monitoring, the deviation at the target is expected to be small while the deviation at the OARs can be very large. Therefore, a method that is able to investigate the cause of a large deviation needs to be developed. In addition, a more clinically relevant measure for the two-dimensional dose comparison and pass/fail criteria need to be further developed.

The Usefulness of Tc-99m MIBI SPECT in the Localization and the Assessment of Radiotherapy in Non-Small Cell Lung Cancer (비소세포 폐암의 국소화 및 방사선치료 판정에 있어 Tc-99m MIBI SPECT의 유용성)

  • Bom, Hee-Seung;Song, Ho-Chun;Kim, Ji-Yeul;Nam, Taek-Keum;Ahn, Sung-Ja;Chung, Woong-Ki;Nah, Byung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.186-191
    • /
    • 1994
  • Tc-99m MIBI, a lipophilic cation, was reported as a useful agent for localization of lung cancer. The effect of radiation therapy on the uptake of Tc-99m MIBI in lung cancer, however, was not well evaluated. The aim of the present study was to elucidate the usefulness of Tc-99m MIBI SPECT in the localization and the assessment of radiotherapy in non-small cell lung cancer. Twenty patients(19 males and 1 female, mean age 59, 16 squamous cell ca and 4 adenoca) were studied with Tc-99m MIBI SPECT before radiation therapy. Eleven patients(10 males and 1 female, mean age 59, 8 squamous cell ca and 3 adenoca) were repeated the study 1 month after the completion of radiation therapy(mean dose 6453cGy). All patients showed positive uptakes of Tc-99m MIBI in their tumors. One patient showed a hot uptake in atelectatic area. There was no difference of Tc-99m MIBI uptakes between squamous cell ca and adenoca either on planar or tomographic images. Tc-99m MIBI uptake ratios of squamous cell ca and adenoca were $1.50{\pm}0.16$ and $1.45{\pm}0.15$ on planar images, and $2.73{\pm}0.46$ and $2.54{\pm}0.37$ on tomographic images, respectively. The concordance between radiological change(chest x-ray and CT) and change of Tc-99m MIBI uptakes was 9/11 (81.8% ). In conclusion, Tc-99m MIBI SPECT was useful in the localization of tumor and the assessment of radiation therapy in non-small cell lung cancer.

  • PDF

Full mouth rehabilitation for a patient with vertical dimension loss using digital diagnostic analysis: A clinical report (수직고경이 감소된 환자의 디지털 진단 분석을 이용한 완전 구강 회복 증례)

  • Choi, Yeawon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Kim, Hyeong-Seob;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.487-496
    • /
    • 2021
  • Full mouth rehabilitation is re-organizing the occlusion of the remaining teeth and missing teeth considering the functions, esthetics, and neuromuscular harmony. With the loss of multiple teeth, the patient's occlusal plane gradually collapses and the vertical dimension can be reduced. Since reduced vertical dimension can be a potential etiology of the temporomandibular joint and masticatory muscles, prosthetic restoration with increased vertical dimension is required. This case report is about a 68 years old patient with vertical dimension loss due to worn dentition and multiple loss of teeth. In this case, the loss of vertical dimension is assessed carefully using the digital dentistry technology. Using CAD software in digital analysis step, the occlusal plane was established and evaluated using several criteria. Orienting the position of the bone and teeth using CBCT image, patient's condition was visualized in 3 dimension and treatment planning was possible virtually. The information that matches the patient's condylar position with the articulator, which is the virtual face bow, is reproduced on the actual articulator, and evaluated again. After the evaluation, provisional prosthesis was fabricated and it was confirmed that the patient adapts without any abnormality. This was implemented as a final prosthesis. As a result, the patient obtained satisfying results, utilizing the benefits of digital dentistry technology and traditional methods.

Clinical Experience of Three Dimensional Conformal Radiation Therapy for Non-Small Cell Lung Cancer (비소세포성 폐암에서 3차원 입체조형 방사선 치료 성적)

  • Choi Eun Kyung;Lee Byong Yong;Kang One Chul;Nho Young Ju;Chung Weon Kuu;Ahn Seung Do;Kim Jong Hoon;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.265-274
    • /
    • 1998
  • Purpose : This prospective study has been conducted to assess the value of three dimensional conformal radiation therapy (3DCRT) for lung cancer and to determine its potential advantage over current treatment approaches. Specific aims of this study were to 1) find the most ideal 3DCRT technique 2) establish the maximum tolerance dose that can be delivered with 3DCRT and 3) identify patients at risk for development of radiation pneumonitis. Materials and Methods : Beginning in Nov. 1994, 95 patients with inoperable non-small cell lung cancer (stage I; 4, stage II; 1, stage IIIa; 14, stage IIIb; 76) were entered onto this 3D conformal trial Areas of known disease and elective nodal areas were initially treated to 45 Gy and then using 3DCRT technique 65 to 70 Gy of total dose were delivered to the gross disease. Sixty nine patients received 65 Gy of total dose and 26 received 70 Gy Seventy eight patients (82.1$\%$) also received concurrent MVP chemotherapy. 3DCRT plans were compared with 2D plans to assess the adequacy of dose delivery to target volume, dose volume histograms for normal tissue, and normal tissue complication Probabilities (NTCP). Results : Most of plans (78/95) were composed of non-coplanar multiple (4-8) fields. Coplanar segmented conformal therapy was used in 17 pateints, choosing the proper gantry angle which minimize normal lung exposure in each segment. 3DCRT gave the full dose to nearly 100$\%$ of the gross disease target volume in all patients. The mean NTCP for ipsilateral lung with 3DCRT (range; 0.17-0.43) was 68$\%$ of the mean NTCP with 2D treatment planning (range; 0.27-0.66). DVH analysis for heart showed that irradiated volume of heart could be significantly reduced by non-coplanar 3D approach especially in the case of left lower lobe lesion. Of 95 patients evaluable for response, 75 (79$\%$), showed major response including 25 (26$\%$) with complete responses and 50 (53$\%$) with partial responses. One and two rear overall survivals of stage III patients were 62.6$\%$ and 35.2$\%$ respectively. Twenty percent (19/95) of patients had pneumonitis; Eight patients had grade 1 pneumonitis and 11 other patients had grade 2. Comparison of the average of NTCP for lung showed a significant difference between patients with and without radiation pneumonitis. Average NTCP for Patients without complication was 62$\%$ of those with complications. Conclusions : This study showed that non-coplanar multiple fields (4-8) may be one of the ideal plans for 3DCRT for lung cancer. It also suggested that 3DCRT may provide superior delivery of high dose radiation with reduced risk to normal tissue and that NTCP can be used as a guideline for the dose escalation.

  • PDF

Dispersion of Standing Stones at Noseongsan(Mt.Noseong) and Aspect of the Stone Decorated Garden(Soo-suk Jeongwon) at Chongsuk-Sa(Chongsuk Buddhist Temple) in Nonsan City (논산 노성산(魯城山)의 입석(立石) 분포와 총석사(叢石寺) 수석(樹石)의 정원적 면모)

  • Rho, Jae Hyun;Huh, Joon;Jang, Il Young
    • Korean Journal of Heritage: History & Science
    • /
    • v.43 no.1
    • /
    • pp.160-189
    • /
    • 2010
  • This study has been designed to grasp the present situation, shapes and meaning of the standing stones and rock pillars in the whole area of Noseong Mountain Fortress in Nonsan City which have never been academically reported yet. Accordingly, the research was carried out to grasp the spatial identity of Noseong Mt. and Noseong Mountain Fortress and the dispersion of standing stones scattered around inside and outside Noseong Mountain Fortress, while the shapes and structural characteristics of stones were investigated and analyzed focusing on Chongsuk Temple, which was considered to have the highest density of standing stones and greatest values for preservation as a cultural property. In consideration of the reference to the 'Top Sa' (tower temple) at the 'Bul Woo Jo' (Article about Buddhism Houses) of 'Shinjoong Dongguk Yeoji Seungram', theoretical existence of the temple according to surveying investigation, and the excavation records of roof tile pieces with the name of 'Gwan Eum Temple', it is presumed that there had been a Buddhist sanctum inside the fortress and it could be connected to the carved letters, 'Chongsuk Temple'. According the observation survey, the 6th place of standing stones among many other places inside the fortress shows that Chongsuk Temple appears to have the strong characteristics of artificially constructed space in consideration of the size of trees and stones, the composite trend of tree and stone composition, and trace of the adjacent well and strand and the construction of stairway leading to the stone gate. Along with the constellation of the Big Dipper carved on a rock at the same space, the stones, on which the letters of 'Shinseonam', 'Chilseongam' and 'Daejangam' were carved, including 'Chongsuksa', and the carved statue of Buddha, which was assumed to be Avalokitesvara Guan Yin, have offered clue which make it possible to infer that the space was a space for Chilseong and Mountain god(Folk Belief) that had originated from the combination of Buddhism, Taoism and folk religion. According to the actual measurement of standing stones at Chonsuk Temple, it was identified that there were big differences in height among 24 stones in total, ranging from 402~29cm and the averaged distance between each stone appeared to be 23.6cm. And the shape of stones appeared to be standing or flat, and various stones such as mountain-like stones and Buddha-like stones were placed in a special arrangement or assorted arrangement, but the direction of the stones had a consistency pointing to the west. And comparing to the trace of construction of ZEN Landscape Garden well known in the country, the three flat stones except for the standing and shaped stones appeared to have the shape of meditation statue, which is the typical formational factors of a ZEN Landscape Garden, on the basis of formational technique of stones. Among them, the flat stone facing the Buddhist saint statue, was formed by way of symbolization of three-mountain stone, which was assumed to be an offering stone for sacrificial food rather than carrying out ZEN Meditation. In consideration of the formation of standing stones at Chong-suk Temple, which was carried out in the composite stoning method based using the scalene triangle with ratio of 3:5:7 in order to seek the in-depth beauty based on the stone statues of three Buddhas where the three factors such as heaven, earth and humans are embodied in the elevated or flat formation, the stones at Chongsuk Temple and the space seemed to the trace of contracted garden construction that was formed with stones for a temple, so that could be used for ZEN meditation.