• Title/Summary/Keyword: 평균 탁도

Search Result 194, Processing Time 0.03 seconds

Fluidization and Heat Transfer Characteristics in the Fluidized Bed(II) (기일고류동층내류동화(氣一固流動層內流動化) 및 전열특성(傳熱特性)에 관한 연구(硏究)(II))

  • Park, Jong-Suen;Baek, Ko-Kil;Kim, Yeun-Young;Jeon, Sung-Taek
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.51-60
    • /
    • 1994
  • The fluidization characteristics of the furan foundry sand fluidized bed and the heat transfer characteristics on a single spiral coil tube in the bed have been investigated. In the paper, the heat transfer coefficients for a single spiral coil tube are measured in the furan foundry sand bed as a function of the ratio of heated coil tube pitch to diameter(p/Do) and the ratio of heated coil tube pitch to particle size(p/dp). The experimental results are as follows. 1) Mean heat transfer coefficients increases according to the increasing ratio of heated coil tube pitch to diameter(p/Do). 2) The Increasing rates of mean Nusselt numbers are more greater in the case of p/Do=1.58 than p/Do=4.75. 3) Mean Nusselt number can be expressed by the following equation, $Nu_{mean}=C\;Re^m\;Pr_g^{0.4}(p/dp)^n$.

  • PDF

The Vertical Changes of Zooplankton Dynamics and Community Filtration Rate in the Artificial Lake (Okjeong Lake) (인공호수(옥정호)내 동물플랑크톤 동태 및 군집 여과율의 수직적 변화)

  • La, Geung-Hwan;Lee, Hak-Young;Kim, Hyun-Woo
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.4
    • /
    • pp.392-401
    • /
    • 2008
  • The vertical changes (upper layer: 0$\sim$0.5 m, middle layer: 4$\sim$5 m and lower layer: 8$\sim$10 m) of the limnological variables, zooplankton dynamics and community filtration rate on the phytoplankton were evaluated monthly intervals from November 2004 to June 2007 at the artificiallake (Okjeong Lake). During the study, the annual mean of water temperatures were 15.2$\pm$7.8$^{\circ}C$ (upper layer), 14.5$\pm$7.4$^{\circ}C$ (middle layer) and 13.0$\pm$6.2$^{\circ}C$ (lower layer), respectively (n=30). The vertical variations of most limnological parameters (DO, pH, conductivity and turbidity) were fairly similar, except for chl.-${\alpha}$ concentration. Annual mean of chl.-${\alpha}$ concentration was highest at the upper layer (21.4 ${\mu}g$ L$^{-1}$), while annual means of concentrations were low at the middle layer and lower layer (4.3 ${\mu}g$ L$^{-1}$ and 3.5 ${\mu}g$ L$^{-1}$, respectively). Annual mean of Secchi depth was 261 cm (n=30). A total 45 species of zooplankton were identified (28 rotifers, 12 cladocerans and 5 copepods) during the study. The mean abundance of rotifers was highest (124$\pm$232 ind. L$^{-1}$, n =90) and that of cladocerans and copepods were relatively low (22$\pm$56 ind. L$^{-1}$ and 13$\pm$30 ind. L$^{-1}$) in the whole layer. Total zooplankton abundance increased from late spring to summer, and then declined and remained low throughout the winter. The annual mean of total zooplankton filtration rate for phytoplankton at the lower layer was much higher than that of both layers (upper layer: 44.4$\pm$107.8, middle layer: 95.1$\pm$436.4 and lower layer: 158.2$\pm$436.4 mL L$^{-1}$ day$^{-1}$). Among the major zooplankton community, relative community filtration rate (RCFR, %) of copepods for phytoplankton (50.2$\sim$54.8%) was much higher than that of cladocerans (27.7$\sim$36.3%) and rotifers (8$\sim$17.6%). The seasonal variation of RCFRs of major zooplankton community was observed. The RCFRs of rotifers were high in winter (44.6%, n=9), while the RCFRs of cladocerans were high in summer (58.0%, n=7). In spring and fall, the RCFRs of copepods were high in the whole layer (spring: 67.4%, n=9; fall: 74.4%, n=5).

Quality Evaluation of the Home-made Soy-Sauce Jangachi, Korean Traditional Pickle, Prepared by the Head-Families of Andong, Korea (안동지역 종가에서 전통적으로 제조된 간장 장아찌의 품질 특성)

  • Kim, Deok-Jin;Kim, Mi-Sun;Lee, Ye-Seul;Sohn, Ho-Yong
    • Microbiology and Biotechnology Letters
    • /
    • v.41 no.3
    • /
    • pp.311-319
    • /
    • 2013
  • In an effort to characterize the physicochemical properties and microbial risks associated with the soy sauce jangachi (Korean traditional pickle), 15 different home-made products, which were prepared from medicinal plants and wild edible vegetables, from head-families of Andong, Kyungsangbuk-do Province in Korea, and 6 different commercial products sold at supermarket, were investigated. The average pH of the mature soaking solutions and plants soaked in the 21 jangachi were $3.99{\pm}0.38$ and $3.51{\pm}0.41$, and the average acidity of the mature soaking solutions and soaked plants were $1.59{\pm}0.54$ and $1.65{\pm}0.76$, respectively. The average brix of the mature soaking solutions and plants soaked were $27.67{\pm}8.38$ and $25.61{\pm}6.60$, respectively. In salinity, which is a major factor in jangachi industry production, the average salinity of the mature soaking solutions and soaked plants were $7.55{\pm}3.26$ and $5.75{\pm}2.23$, respectively. In particular, the hot-peppers, eusuri, du-rup, kaet-ip, kuji-ppong, myeng-i and sancho jangachi were amongst the home-made products, and the salinity was above 8.8%, which was 2 folds-higher than that of the commercial sterilized products, and 1/3-lower than commercial non-sterilized products. The color difference and turbidity of jangachi were dependent on the plant parts used. In microbial risk assessment, the microorganisms related with food-borne disease, such as Escherichia coli, Salmonella sp, and Shigella sp., were not detected. After some time, total cell count analysis revealed that the commercial products sold at supermarkets were more vulnerable than the home-made products.

Effect of $N_2$-back-flushing Time and TMP in Lake Water Treatment Using Multichannel Ceramic Microfiltration Membranes (다채널 세라믹 정밀여과막으로 호소수 처리시 질소 역세척 시간 및 막간 압력차의 영향)

  • Park, Jin-Yong;Park, Bo-Reum
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.124-133
    • /
    • 2007
  • In this study, we treated lake water by 2 kinds of multichannel ceramic micro filtration membranes. We could investigate effects of $N_2-back-flushing$ time (BT) and transmembrane pressure (TMP), and find optimal operating conditions. The BT were changed in $10{\sim}60$ sec, TMP in $0.6{\sim}2.0$ bar at fixed filtration time (FT) 8 min, flow rate 2.0 L/min and back-flushing pressure 2.0 bar. Also, the optimal conditions were discussed in the viewpoints of resistance of membrane fouling $(R_f)$, dimensionless permeate flux $(J/J_o)$, permeate flux (J) and total permeate volume $(V_T)$. As result, optimal back-flushing conditions for HC04 ($0.4{\mu}m$ pore size) and HC10 membrane $(1.0{\mu}m)$ were BT=10 sec and BT=20 sec, respectively. Then, higher TMP should increase the driving force, and could produce more VT. Average rejection rates of pollutants were higher than 95.4% for turbidity, $12.7{\sim}20.1%\;for\;COD_{Mn},\;0.0{\sim}6.4%\;for\;NH_3-N,\;1.9{\sim}4.6%$ for T-N and $34.9{\sim}88.4%$ for T-P.

Trophic State and Water Quality in Major Lakes of the Sumjin and Youngsan River Systems (섬진강 ${\cdot}$ 영산강 수계 주요 호소의 수질 동향과 영양상태 조사)

  • Yi, Sang-Hyon;Chang, Nam-Ik;Kim, Jong-Min;Kim, Hyun-Ku;Cho, Young-Gwan;Jeong, Jin;Sin, Yong-Sik
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.3 s.117
    • /
    • pp.296-309
    • /
    • 2006
  • This study aimed to analyze water quality (temperature, secchi depth, DO, $NH_4$, $NO_3$, $PO_4$, TN, TP, chlorophyll a) and trophic state index during the period of year 2000 ${\sim}$ 2004 in Lake Juam, Lake Dongbok and Lake Youngsan. Lakes Juam and Dongbok except Lake Youngsan were stratified during warm seasons. Water turbidity estimated by secchi disk depth was the highest in Lake Youngsan compared with other lakes. DO concentrations were low in the bottom water when chlorophyll a was high in Lake Juam and Dongbok. Nutrient concentrations were higher in Lake Youngsan than other lakes whereas chlorophyll a was highest in Lake Dongbok. Lake Youngsan was the most eutrophic compared to other two lakes based on the Trophic State Idex (TP) and TSI (SD), The TSI (CHL) was high but the TSI (TP) were low in Lake Juam and Dongbok. These results suggest phytoplankton may be limited by phosphates (P) in Lake Juam and Dongbok whereas light availability in the water column may affect growth of phytoplankton in Lake Youngsan.

Water Quality Variation on the Unit Operation of Water Treatment Process When CCPP Index was Controlled for Internal Corrosion of Water Pipes (수도관 내부부식방지를 위한 CCPP 조절시 정수공정내에서의 수질변화)

  • Lee, Jae-In;Kim, Do-Hwan;Lee, Ji-Hyung;Kim, Dong-Youn;Hong, Soon-Heon;Shin, Pan-Sae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.362-368
    • /
    • 2005
  • The pH, alkalinity and calcium hardness could be adjusted by $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ addition in the water treatment process for corrosion protection of the water pipes. This research was performed to investigate the effect on the variation of water quality on the unit process by addition $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ in water treatment process. Carbon dioxide and lime were added before the coagulation basin and soda ash was added after the BAC process. pH and aklainity were increased at coagulation basin then after the water qualities had sustained similiarly to BAC process. There was no effect on turbidity and DOC removal efficiency during experimental period by addition\ $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ solution was added into clear well, the last process for optimum control of CCPP and is used mainly to control pH and alkalinity. In this research, average pH, alkalinity, and calcium hardness in treated water were 8.39, 61.4 mg/L as $CaCO_3$, 59.4 mg/L as $CaCO_3$, respectively and CCPP of treated water was higher than 29.5 mg/L to BAC process water, so adjusted water was expected to prevent internal corrosion of water pipe.

Evaluation of Suspended Solids and Eutrophication in Chungju Lake Using CE-QUAL-W2 (CE-QUAL-W2를 이용한 충주호의 부유물질 및 부영양화 모의평가)

  • Ahn, So Ra;Kim, Sang Ho;Yoon, Sung Wan;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.11
    • /
    • pp.1115-1128
    • /
    • 2013
  • The purpose of this study is to evaluate the suspended solids and eutrophication processes relationships in Chungju lake using CE-QUAL-W2, two-dimensional (2D) longitudinal/vertical hydrodynamic and water quality model. For water quality modeling, the lake segmentation was configured as 7 branches system according to their shape and tributary distribution. The model was calibrated (2010) and validated (2008) using 2 years of field data of water temperature, suspended solids (SS), total nitrogen (TN), total phosphorus (TP) and algae (Chl-a). The water temperature began to increase in depth from April and the stratification occurred at about 10 m early July heavy rain. The high SS concentration of the interflow density currents entering from the watershed was well simulated especially for July 2008 heavy rainfall event. The simulated concentration range of TN and TP was acceptable, but the errors might occur form the poor reflection for sedimentation velocity of nitrogen component and adsorption-sediment of phosphorus in model. The concentration of Chl-a was simulated well with the algal growth patterns in summer of 2010 and 2008, but the error of under estimation may come from the use of width-averaged velocity and concentration, not considering the actual to one side inclination by wind effect.

Water Column Properties and Dispersal Pattern of Suspended Particulate Matter (SPM) of Marian Cove during Austral Summer, King George Island, West Antarctica (남극 킹죠지섬 마리안 소반의 하계 수층 특성과 부유물질 분산)

  • Yoo, Kyu-Cheul;Yoon, Ho-Il;Oh, Jae-Kyung;Kim, Yea-Dong;Kang, Cheon-Yun
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.4
    • /
    • pp.266-274
    • /
    • 1999
  • Vertical CTDT measurement at one point near tidewater glacier of fjord-head in Marian Cove, a tributary embayment of Maxwell Bay, South Shetland Islands was performed for 24 hours during the austral summer (January 21-22, 1998) to present water-column properties and SPM (suspended particulate matter) dispersal pattern in subpolar glaciomarine setting. Marian Cove shows three distinct water layers: 1) cold, freshened, and highly turbid surface plume in the upper 2 m, 2) warm, saline, and relatively clean Maxwell Bay water between 15-35 m in water depth, and 3) cold and turbid mid plume between 40-65 m in water depth. The surface plume is composed of silt-sized clastie particles mixed with flocculated biogenic detritus, and appears to originate from either supraglacial discharge by meltwater streams along the coast or water fall of ice cliff. Freshened and turbid mid plume consists exclusively of silt-sized clastic particles, resulting from subglacial discharge beneath the tidewater glacier. The disappearance of the two turbid plumes during the earlier period of measurement seems to be largely due to the breakup of the plumes by upwelling caused by strong easterly wind (> 8 m $sec^{-1}$). Thus, wind coupling over tidal effects regionally plays a major role in dispersal pattern of SPM as well as water exchange in Marian Cove.

  • PDF

Transfer Function Model Forecasting of Sea Surface Temperature at Yeosu in Korean Coastal Waters (전이함수모형에 의한 여수연안 표면수온 예측)

  • Seong, Ki-Tack;Choi, Yang-Ho;Koo, Jun-Ho;Lee, Mi-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.5
    • /
    • pp.526-534
    • /
    • 2014
  • In this study, single-input transfer function model is applied to forecast monthly mean sea surface temperature(SST) in 2010 at Yeosu in Korean coastal waters. As input series, monthly mean air temperature series for ten years(2000-2009) at Yeosu in Korea is used, and Monthly mean SST at Yeosu station in Korean coastal waters is used as output series(the same period of input). To build transfer function model, first, input time series is prewhitened, and then cross-correlation functions between prewhitened input and output series are determined. The cross-correlation functions have just two significant values at time lag at 0 and 1. The lag between input and output series, the order of denominator and the order of numerator of transfer function, (b, r, s) are identified as (0, 1, 0). The selected transfer function model shows that there does not exist the lag between monthly mean air temperature and monthly mean SST, and that transfer function has a first-order autoregressive component for monthly mean SST, and that noise model was identified as $ARIMA(1,0,1)(2,0,0)_{12}$. The forecasted values by the selected transfer function model are generally $0.3-1.3^{\circ}C$ higher than actual SST in 2010 and have 6.4 % mean absolute percentage error(MAPE). The error is 2 % lower than MAPE by ARIMA model. This implies that transfer function model could be more available than ARIMA model in terms of forecasting performance of SST.

Effect of Coagulated Flocs Broken by the Pressure Pump on Removal Rate and Membrane Fouling of Pressurized MF process (가압펌프에 의해 해체된 플럭이 가압식 막여과 공정의 제거효율 및 막오염에 미치는 영향)

  • Kim, Junhyun;Moon, Baeksu;Park, Jongsu;Cho, Yoonho;Kim, Jinho
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.460-468
    • /
    • 2013
  • This study reviewed optimum dosage rate of coagulant and ability to remove dissolved organic carbon without sedimentation in conventional water purification plant. It was confirmed that floc formated by pre-treatment process was broken by impeller of booster pump. Optimum dosage rate of coagulant was 4 mg/L (as PACl 17%) for floc formation through blend, coagulation and after passing through the pump when turbidity of raw water was less than 10 NTU. And average removal rate of dissolved organic carbon was 43% at that time. Maximum removal rate of dissolved organic carbon was 48%, even though coagulation rate was increased gradually until 8 mg/L (as PACl 17%). So removal rate of dissolved organic carbon is not much improved even if dosage rage of coagulant increase. TMP of PVDF (polyvinylidene flouride) pressurized MF process without pre-treatment operated at 0.54 bar and TMP of PVDF pressurized MF process with pre-treatment operated at 0.41 bar.