• Title/Summary/Keyword: 평균입자

Search Result 1,278, Processing Time 0.032 seconds

Change of Calcium Carbonate Crystal Size at steady state in CMSMPR(Continuous Mixed Suspension Mixed Produce Removal) Crystallizer (연속식결정화기 정상상태에서 탄산칼슘 결정크기 변화)

  • Han, Hyun Kak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.714-719
    • /
    • 2017
  • The controlled synthesis of inorganic materials with a specific size and morphology is an important factor in the development of new materials in many fields, such as nanoparticles, medicine, electronics, semiconductors, pharmaceutical sand cosmetics. Solution crystallization is one of the most widely used separation processes in the chemical and pharmaceutical industries. Calcium carbonate has attracted a great deal of attention in industry because of its numerous applications. The mean crystal size, crystal size distribution and morphology are important factors in the continuous crystallization process. In this study, the continuous crystallization of calcium carbonate by the calcium chloride process was investigated. The mean crystal size and crystal size distribution data were obtained by a particle size analyzer. The morphological imaging of the crystalswasper formed by SEM. Under steady state operation, the mean crystal size change was small, but increasing the input concentration and mixing rate increased the crystal size. In this operation, some aragonite was found, but the main crystal phase was calcite.

Measurement of 100-nm polystyrene sphere by transmission electron microscope (투과형 전자현미경을 이용한 100nm폴리스티렌 구의 측정)

  • 박병천;정기영;송원영;오범환
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.57-57
    • /
    • 2002
  • 100 nm 이하의 입자의 크기와 모양을 정확하게 측정할 수 있는 기술개발을 위하여 투과형 전자현미경(TEM)으로 100 nm 지름의 폴리스티렌구의 평균지름을 측정하였다. 기기 표시 배율과 엣지결정불확도에 의한 크기측정오차를 최소화하기 위하여, 지름이 정확히 알려진 300 nm 입자를 내부 기준자로 쓰기 위하여 100 nm 입자와 섞었다. 100 nm 입자들의 지름은 동일한 TEM 필름상의 300 nm 입자와의 비교를 통하여 얻어졌다. 전자빔에 의한 입자축소효과의 보정을 위하여, 가속전압, 빔세기, 그리고 노출시간이 축소량에 미치는 정량적 관계를 조사하고 분석하였다. 그러한 분석과 몇가지 데이터 처리과정에 기초하여, 100 nm 폴리스티렌구의 평균지름을 95 % 신뢰수준에서 확장불확도 2 %로 결정하였다. 측정값은 동일한 쌤플에 대하여, 다른 방법을 사용하는 다른 실험실들과의 결과와도 일치하고 있다.

  • PDF

준안정 준위를 포함한 헬륨 플라즈마의 영차원 모사 연구

  • O, Seung-Ju;Bang, Jin-Yeong;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.520-520
    • /
    • 2012
  • 플라즈마 방전의 공간 평균 모사는 플라즈마 변수에 대한 정확한 값을 주지는 않지만 방전외부 조건에 따른 플라즈마 변수 변화를 통해 플라즈마 특성을 예측하는데 많은 도움을 준다. 본 연구에서는 준안정준위를 포함한 다단계 이온화 반응을 고려하여 헬륨 플라즈마의 공간 평균 모사를 진행하였다. 플라즈마에 흡수된 전력, 압력에 따른 각 입자의 생성, 소멸에 대한 입자 보존식과 전자에 대한 에너지 보존식을 통하여 플라즈마 변수를 얻었으며, 반응식을 세우기 위하여 헬륨 원자 에너지 준위 내의 특정 준위를 택하여 준위 간의 전이 반응 계수를 계산하였고 실험값과 비교하였다.

  • PDF

Ignition Temperature and Residence Time of Suspended Magnesium Particles (마그네슘 부유 분진의 입자 체류시간과 발화온도)

  • Han, Ou-Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.25-31
    • /
    • 2015
  • Effects of residence time on the MIT(Minimum Ignition Temperature) in suspended Mg particles are examined by using MIT experimental data and calculation results of terminal velocity. With increasing of the average particle diameter, we were able to identify that MIT of Mg dusts increased and the calculated residence time of particle decreased exponentially. Also, the influence on terminal velocity due to temperature increase increased slightly with increasing of average particle diameter.

Size Distribution of Metals and Ionic Species of $PM_{10}$ in Industrial Complex of Gunsan(Korea) (군산 산단의 PM10 중 금속성분과 이온성분의 크기 분포)

  • 김성천
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.405-406
    • /
    • 2003
  • 현재 우리나라 입자상물질에 대한 대기환경기준은 공기역학적 직경 10 $\mu\textrm{m}$ 이하인 PM$_{10}$ 기준이 연평균 70 $\mu\textrm{g}$/㎥ 및 일평균 150 $\mu\textrm{g}$/㎥이다. 그러나 영국의 PM$_{10}$ 기준은 24시간 평균 50 $\mu\textrm{g}$/㎥로 강화하여 입자상물질에 의한 건강피해를 줄이기 위해 노력하고 있다(EPAQS, 1995). 분진은 공기역학적 직경 2.5 $\mu\textrm{m}$를 기준으로 미세입자와 거대입자로 나누어지는 쌍극분포의 형태(Whitby et al., 1972)를 나타내며, 분진이 인체에 미치는 영향에 관한 많은 연구를 통해 10 $\mu\textrm{m}$ 이하의 입자가 호흡성 분진으로 인체에 더 유해한 영향을 미치고 있음이 밝혀졌다(Emison, 1988). (중략)

  • PDF

Velocity Measurement of Granular Flow with Block Matching (블록 매칭을 이용한 Granular Flow의 속도 측정)

  • Lee, Jin-Geol
    • The Journal of Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.5-11
    • /
    • 1997
  • The flow of granular materials is common to many industrial processes. This paper discusses a methodology which utilizes high speed digital imaging to measure velocity of dry granular solids flowing down an inclined chute under the action of gravity. Glass particles have been used as granular solids in our experiment. The proposed technique utilizes block matching for spatially averaged velocity measurements of the glass particles. The velocity measurements are refined to the subpixel resolution by the variance normalized correlation with interpolation.

  • PDF

ISO 규격에서 규정한 표준용기 기체도입 도관의 직경에 대한 고찰

  • In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.332-332
    • /
    • 2010
  • 진공펌프의 배기성능 지표들을 정량적으로 측정하기 위해서 사용하는 표준용기에 관한 규격들은 대체로 일치하는 사양들을 제시하지만 유독 기체도입 도관의 굵기에 대해서는 다양한 방식으로 규정하고 있어서 혼란스럽다. 현재 제정중인 ISO 규격에서는 도관 굵기를 용기 내경의 10분의 1로 규정하고 있는데 대형 펌프 용 표준용기에 맞춘다면 도관의 굵기가 지나치게 커질 수 있다. 과연 이렇게 굵은 도관이 정밀한 측정을 위해 꼭 필요한지 또는 오히려 방해가 되는 것은 아닌지 검토해 보기 위해 도관 굵기에 따라 도관출구를 빠져나오는 입자들과 오리피스 및 펌프 흡기구에 입사하는 입자들의 등방성에 대해 살펴보았다 계산 결과에 의하면 도관의 굵기는 오리피스 및 펌프 흡기구에 입사하는 입자들의 평균 방향 여현 값에 전혀 영향을 미치지 않는 것으로 나타났으며 반면에 도관이 오리피스나 흡기구 면에 국부적으로 그림자를 드리우거나 입자 분포와 평균 방향여현 분포를 왜곡시키지도 않았다. 즉 기체 도입 도관을 가늘게 해도 빔효과가 계속 전파되어서 측정에 악영향을 미치지 않으므로 별 문제가 안 되고, 도관이 규정되어 있는 범위 안에서 어느 정도 굵어져도 입자의 흐름을 방해한다는 증거는 없다는 뜻이다. 그렇다면 도관의 굵기를 한 값으로 못 박기보다 넓은 범위를 주어 가공 능력에 따라 사용자가 적절히 크기를 선택할 수 있도록 하는 것이 합리적이라고 판단된다.

  • PDF

Particle-Based Extended Marching Cubes with Efficient Quadratic Error Function (효율적인 2차 오차 함수를 이용한 입자 기반 Extended Marching Cubes)

  • Yu-Bin Kwon;Jong-Hyun Kim
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2024.01a
    • /
    • pp.387-390
    • /
    • 2024
  • 본 논문에서는 효율적인 2차 오차 함수를 이용하여 입자 기반에서 EMC(Extended Marching Cubes) 알고리즘을 구현할 수 있는 새로운 알고리즘을 제안한다. Smoothing 커널(Kernels)을 통해 계산한 입자 평균 위치에서 레벨셋(Level-set)을 계산해 스칼라장을 구축한다. 그리고 난 뒤 SPH(Smoothed particle hydrodynamics)기반의 커널을 통해 밀도, 입자 평균 위치를 계산한다. 스칼라장을 이용해 등가 곡면(Isosurface)을 찾고 음함수로 표현된 표면을 구성한다. SPH 커널을 공간에서 미분하면 공간상의 어느 위치에서나 기울기를 계산할 수 있고, 이를 통해 얻어진 법선벡터를 이용하여 일반적인 EMC나 DC(Dual contouring)에서 사용하는 2차 오차 함수를 효율적으로 설계한다. 결과적으로 제안하는 방법은 메쉬와 같이 연결정보다 없는 입자 기반 데이터에서도 EMC 알고리즘을 구현하여 볼륨(Volume) 손실을 줄이고, 복잡한 음함수 표면을 표현할 수 있게 한다.

  • PDF

Preparation and Characterization of Phenolic/Furfural Organic Gel Microspheres in Supercritical $CO_2$ (초임계 이산화탄소를 이용한 Phenolic/Furfural계 유기 겔 입자의 합성 및 물성)

  • 이경남;이해준;김중현
    • Polymer(Korea)
    • /
    • v.24 no.1
    • /
    • pp.8-15
    • /
    • 2000
  • Phenolic/furfural(P/F) gel microspheres were successfully produced by new supercritical $CO_2$-based process. $CO_2$-soluble poly(dimethylsiloxane) (PDMS) was used as the stabilizer in this system. Spherical morphology of the gel microspheres was confirmed by scanning electron microscopy. Particle size and particle size distribution of P/F gel microspheres can be modified by variety of the solids content and the stabilizer content. The resultant P/F gel microspheres have average particle size in the range of 1-6 ${\mu}{\textrm}{m}$. The structure of P/F gel microspheres was revealed by thermogravimetric analysis and IR analysis.

  • PDF

Design and Characterization of Ascorbyl Glucoside loaded Solid Lipid Nanoparticles to improve skin penetration (피부 투과 개선을 위한 고형지질나노입자내 Ascorbyl glucoside 봉입 설계 및 특성화)

  • Yeo, Sooho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.662-668
    • /
    • 2021
  • The aim of the present study was to design ascorbyl glucoside (AG) loaded solid lipid nanoparticles (SLNs) to improve skin penetration of AG. AG loaded SLNs were prepared using double emulsion method. The prepared AG loaded SLNs investigated particle characteristics (particle size, polydispersity index, zeta potential, loading capacity). Skin penetration study was carried out using SkinEthic RHE as one of the reconstructed human epidermis models. The mean particle size and zeta potential of SLNs were 172.65 - 347.19 nm and -22.90 - -41.20 mV, respectively. The loading capacity of AG loaded SLNs demonstrated that loading efficiency and loading amount were ranged from 44.18% to 57.77% and 12.83% to 16.15%, respectively. The results of penetration showed that all SLNs enhanced the skin penetration of AG and the amount of AG from SLNs were approximately 3.7 - 7.4 times higher than that from AG solution. Therefore, AG loaded SLN might be a promising topical drug delivery system.