• Title/Summary/Keyword: 평균유동장

Search Result 165, Processing Time 0.031 seconds

Effect of Nozzle Shape and Injection Pressure on Performance of Hybrid Nozzle (노즐 형상 및 분사 압력이 하이브리드 노즐 성능에 미치는 영향 연구)

  • Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.74-79
    • /
    • 2017
  • The fire extinguishing performance of hybrid nozzle systems is improved by injecting an extinguishing agent concentrically into the target site and, in this study, water mist is used as a water curtain to confine the droplets of the agent. In this study, we numerically investigated the effect of the foundation angle and injection pressure on the performance of a hybrid nozzle by evaluating the mean radius of the volume fractions of the agent and water mists. An experiment involving a water mist nozzle was carried out to validate the numerical method and then the droplet behaviors, e.g., stochastic collision, coalescence and breakup, were calculated with 2-way interaction Discrete Particle Modeling (DPM) in the steady state for the hybrid nozzle system. The mean radius of the water mists increased by about 40 %, whereas that of the agent decreased by about 21 %, when the injection pressure was increased from 30 bar to 60 bar. In addition, the mean radius of the agent increased by about 24 % as the foundation angle of the hybrid nozzle head increased from $30^{\circ}$ to $60^{\circ}$. As a result, it can be inferred that the injection angle and pressure are important factors for hybrid water mist designs.

Comparison of the Flame Height of Pool Fire according to Combustion Models in the FDS (FDS의 연소모델에 따른 풀화재의 화염높이 비교)

  • Han, Ho-Sik;Hwang, Cheol-Hong;Oh, Chang Bo;Choi, Dongwon;Lee, Sangkyu
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.42-50
    • /
    • 2018
  • The effect of sub-grid turbulence and combustion models on the mean flame height in a heptane pool fire according to the Fire Dynamics Simulator (FDS) version (5 and 6) based on Large Eddy Simulation (LES) was examined. The heat release rate for the fire simulation was provided through experiments performed under identical conditions and the predictive performance of the mean flame height according to FDS version was evaluated by a comparison with the existing correlation. As a result, the Smagorinsky and Deardorff turbulence models applied to FDS 5 and 6, respectively, had no significant effects on the mean flow field, flame shape and flame height. On the other hand, the difference in pool fire characteristics including the mean flame height was due mainly to the difference in the mixture fraction and Eddy Dissipation Concept (EDC) combustion models applied to FDS 5 and 6, respectively. Finally, compared to FDS 6, FDS 5 provided the predictive result of a significantly longer flame height and more consistent mean flame height than the existing correlation.

The Flow Control by a Horizontal Splitter Plate for a Square Prism near a Wall (벽면에 근처에 놓인 정방형주의 수평 분리판에 의한 유동 제어)

  • Ro, Ki-Deok;Lee, Sang-Jun;Lee, Gyeong-Yun;Jang, Jae-Dong;Jung, Yong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.625-631
    • /
    • 2011
  • The passive control of fluid force acting on a square prism near a plane wall was studied by attaching horizontal splitter plate on the corner of the prism. The width of the splitter plate was 10% of the square width. The experiments were performed by measuring of fluid force on the prism and by visualization of the flow field using PIV. The experimental parameters were the attaching position and the space ratios G/B between the prism and wall. The flow between the prism and wall was remarkable and Karman vortex in the wake of the prism was considerable in the space ratio over 0.4. The point of inflection of average lift coefficient and Strouhal number on the prism were represented at the space ratio G/B=0.4 for the prototype prism and G/B=0.6 for the prism having horizontal splitter plate. The drag of the prism was reduced average 4.5% with the space ratios by attaching the horizontal splitter plate at the rear and lower corner on the prism. In this case, the size of the separated region on the upside of the prism was smaller than that of prism without the splitter plate.

Examination on Numerical Simulation Using Reduced-scale Model of Theater Fire: Influences of Fire Curtain and Stage Natural Vent (공연장 화재 축소모형을 이용한 전산시뮬레이션 검토: 방화막 및 무대부 자연배출구 영향)

  • Yang, Ji Hyun;Baek, Seon A;Lee, Chi Young;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.37-47
    • /
    • 2019
  • In the present study, the influences of the fire curtain and natural vent in a theater fire were investigated through the numerical simulation of a reduced-scale model of a theater fire using the Fire Dynamics Simulator (FDS). Based on a previous experimental study using the reduced-scale model, the 1/14 reduced-scale model and its conditions were constructed according to the law of similarity with a real-scale theater. Through a series of numerical simulations, the smoke movements were visualized, and the temperatures in the stage and auditorium, mass flow rate of the outflow through natural vent, and time at which smoke started moving toward the auditorium were measured and analyzed. The general trends on the effects of the fire curtain and natural vent during the theater fire predicted by the present numerical simulation were similar to the previous experimental results. For quantitative comparison of the present numerical simulation and previous experimental results, the mean percentage errors of temperatures in the stage and auditorium, and the mass flow rate of outflow through the natural vent were calculated. The present numerical simulation results showed good agreement with previous experimental results with reasonable accuracy.

Impacts of Combined Hydrogeological and Chemical Heterogeneities on the Transport of Leachate through Landfill Sites (수리지질학적, 화학적 특성의 복합 불균질성이 매립지반 내 침출수 이동에 미치는 영향)

  • Lee, Kun-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.300-307
    • /
    • 2009
  • The transport of landfill leachate in the subsurface formations of unlined landfill sites is considered. The impacts of hydrogeological and chemical heterogeneities on the leachate transport are assessed by examining the results from a series of Monte-Carlo simulations. The landfill system simulated in this study is hypothetically represented with three levels of spatial variability for the hydrogeological and chemical parameter; (1) homogeneous hydraulic conductivity (K) and distribution coefficient ($K_d$), (2) K heterogeneity only, and (3) combined heterogeneities of K and $K_d$. To calculate the transport of leachate through negatively-correlated random hypothetical K-$K_d$ fields generated using geostatistical input parameters, a saturated flow model is linked with a contaminant transport model. Point statistic values such as mean, standard deviation, and coefficient of variation of the concentration were obtained from 100 Monte-Carlo trials. Results of point statistics show that the heterogeneities of K and $K_d$ in the landfill site prove to be an important parameter in controlling leachate concentrations. Consideration of combined K and $K_d$ heterogeneities results in enhancing the variability of contaminant transport. The variability in the leachate concentration for different realizations also increases as the distance between source and monitoring well increase.

Comparison between GOx/Kerosene and GN2O/Ethanol Reactive Spray in a Subscale Liquid Rocket Engine (축소형 액체로켓엔진에서 기체산소/케로신 및 기체아산화질소/에탄올 연소 분무의 비교)

  • Choi, Songyi;Shin, Bongchul;Lee, Keonwoong;Kim, Dohun;Koo, Jaye;Park, Dong-Kun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.61-68
    • /
    • 2015
  • Reactive sprays of two propellant combinations(GOx/kerosene and $GN_2O$/ethanol) were observed and compared with each other as a basic research of visualizing supercritical combustion. A shadowgraph imaging method was used to visualize the reactive sprays, and shadowgraph images were converted to density gradient magnitude images to analyse the structure of reactive sprays. The gas-liquid interface of GOx/kerosene spray showed rougher boundary and steeper density gradient near the injector face than the $N_2O$/ethanol at similar combustion chamber pressure. Spray core length was calculated from averaged density gradient magnitude images and it was revealed that spray core length of GOx/kerosene was shorter than that of $GN_2O$/ethanol, although momentum flux ratio of GOx/kerosene propellant combination was lower.

The Structure of Three-dimensional Turbulent Flow Fields of a Cone Type Gas Swirl Burner (콘형 가스 스월버너의 3차원 난류 유동장 구조)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.5 no.2
    • /
    • pp.22-29
    • /
    • 2001
  • This paper represents axial mean velocity, turbulent kinetic energy and swirl number based on momentum flux measured in the X-Y plane and Y-Z plane respectively of a cone type gas swirl burner by using X-probe from the hot-wire anemometer system. This experiment is carried out at flow rates 350 and $450{\ell}/min$ respectively, which are equivalent to the combustion air flow rate necessary for heat release 15,000 kcal/hr in gas furnace, in the test section of a subsonic wind tunnel. Axial mean velocities and turbulent kinetic energies show that their maximum values exist centering around narrow slits situated radially on the edge of and in the forefront of a burner until $X/R{\fallingdotseq}1.5$, but they have a peculiar shape like a starfish diffusing and developing into inward and outward of a burner by means of the mixing between flows ejected from narrow slits, an inclination baffle plate and swirl vanes respectively according to downstream regions. Moreover, they show a relatively large value in the inner region of 0.5$S_m$ obtained by integration of velocity profiles shows a characteristic that has an inflection point composing of the maximum and minimum value until X/R<3, but shows close agreement with the geometric swirl number after a distance of X/R=3.

  • PDF

The Effect of the Size of Coal Particles on Gasification Reactions (석탄입자 크기가 가스화에 미치는 영향)

  • Cho, Seok-Yeon;Seo, Kyung-Won
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.77-86
    • /
    • 1997
  • In this study, numerical computations were performed to scrutinize the effect of the size of coal particles on reactive flow fields and concentration distribution of product gases for five cases with four different particle sizes (40 $\mu\textrm{m}$, 60 $\mu\textrm{m}$, 100 $\mu\textrm{m}$, 120 $\mu\textrm{m}$, 140 $\mu\textrm{m}$) in an axisymmetric cylindrical coal gasifier in which Alaska Usibelli subbituminous coals were gasified. Predictions showed that coal particle size affected the concentration distribution of product gases. When coals of 100 $\mu\textrm{m}$ were gasified, the maximum average concentrations of major products, H$_2$and CO, were predicted at the exit of the gasifier. The average mole fractions of CO and H, were shown to be 0.62, and 0.16 (dry basis, inert free), respectively. The cold gas efficiency of 83% was also predicted for the same particle size of 100 $\mu\textrm{m}$.

  • PDF

The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves (인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향)

  • 이계한;서종천
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 1998
  • The sinus distal to the prosthetic heart valve influences the valve closure behavior and velocity field near the valve, therefore affects the hydrodynamic performance of the prosthetic heart valve. In order to study the effects of valve distal geometry on the hydrodynamic performance of the prosthetic valves, mechanical bileaflet valve(SJMV), monoleaflet polymer valve(MLPV) and trileaflet polymer valve(FTPV) are inserted in the test sections which have the straight and the sinus shape distal to the valve. Leakage volumes and systolic mean pressure drops are measured in the pulsatile mock circulation flow loop. Leakage volumes are slightly less and systolic mean pressure drops are higher in the sinus test section comparing to those in the straight test section, but the differences are statistically insignificant. Flow waveforms are analyzed in order to predict the valve closure behavior. The distal sinus does not affect the closure of the MLPV, but early valve closure of SJMV is observed in the sinus test section. This effect is more significant in FTPV, and the reverse flow peak of FTPV is reduced in the sinus test section. Therefore the sinus distal to the valve can reduce the reverse flow jet caused by sudden valve closure.

  • PDF

Three-Dimensional Natural Convection from a Single Module on the Wall of a Vertical Parallel-Plate Channel (수직평행채널의 벽면에 부착된 단일모듈로부터의 3차원 자연대류 열전달)

  • Riu, K.J.;Lee, J.H.;Kim, H.W.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.29-41
    • /
    • 1999
  • Three-dimensional natural convective heat transfer in a vertical channel with a protruding single module was investigated experimentally. The particular interest was in the removal of thermal energy from the module by convective heat transfer. Hence radiative and conductive heat losses were estimated by using thermocouples and heat flux sensor respectively. The flow fields in the channel were visualized by means of a smoke-method. Also, local temperatures were measured by thermocouples inside the channel, along the vertical wall and module surface. It is found that convective heat transfer was promoted at the lower comer of the module and was decreased at the upper comer due to a recirculation zone. A general correlation of the critical channel ratios was found as a function of Rayleigh number. For the range of $8.28{\times}10^3<Ra^*_c<3.48{\times}10^6$, a useful correlation for the mean Nusselt number was proposed as a function of modified channel Rayleigh number.

  • PDF