• Title/Summary/Keyword: 평균유동구조

Search Result 115, Processing Time 0.025 seconds

A Study on the Effects of Fin Length on Natural Convection Heat Transfer from a Inclined Flat Plate (경사평판에서의 핀길이가 자연대류 열전달에 미치는 영향에 관한 연구)

  • 천대희
    • Fire Science and Engineering
    • /
    • v.12 no.1
    • /
    • pp.3-8
    • /
    • 1998
  • This study has been conducted experimentally on the effects of natural convection heat transfer characteristics for inclined flat plate with vertical fin in air. The effects of various fin length, flat plate inclined angle and Grashof number are mainly investigated The experimented results are as follows: The mean heat transfer coefficient increase according to the decrease of H/S in the various fin lengh. The mean heat transfer coefficient at H/S-0.5, 1.0, 1.5 for Gr=2.11$\times$103. $\theta$=00 increase by 107%, 43%, 15% than H/S=2.0. The mean heat transfer coefficient decrease with the increase of $\theta$ the inclined angles. The mean heat transfer coefficient at Gr=2.97$\times$103 is constant, at $\theta$= 00 for H/S=0.5 decrease by 33% than $\theta$=90$^{\circ}$. The mean heat transfer coefficient increase as Grashof as Grashof number increase. The mean heat transfer coefficient at Gr=2.31$\times$103, Gr=2.61$\times$103, Gr=2.97$\times$103 for H/S=1.0, $\theta$=0$^{\circ}$increase by 9%, 16%, 28% than Gr=2.11$\times$103.

  • PDF

Experimental Validation of Ornithopter Aerodynamic Model in Low Reynolds Number Regime (저 레이놀즈 수 영역에서 날갯짓 비행체 공력 모델의 실험적 검증)

  • Lee, Jun-Seong;Kim, Dae-Kwan;Han, Jae-Hung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.7
    • /
    • pp.647-654
    • /
    • 2010
  • In this study, an efficient ornithopter aerodynamic model, which is applicable to ornithopter wing design considering fluid-structure interaction or ornithopter flight dynamics and control simulation, was proposed and experimentally validated through the wind tunnel experiments. Due to the ornithopter aerodynamics governed by unsteady low Reynolds number flow, an experimental device was specially designed and developed. A part of the experimental device, 2-axis loadcell, was situated in the non-inertial frame; the dynamic calibration method was established to compensate the inertial load for pure aerodynamic load measurements. The characteristics of proposed aerodynamic model were compared with the experimental data in terms of mean and root-mean-square values of lift and drag coefficients with respect to the flow speed, flapping frequency, and fixed angle of attack.

A Study on the Influence of Turbulent Intensity on DOHC Engine Performance (DOHC 가솔린기관의 연소실 난류특성이 기관성능에 미치는 영향에 관한 연구)

  • Kim, C.S.;Choi, Y.D.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.2
    • /
    • pp.12-23
    • /
    • 1994
  • In order to investigate the effect of turbulent intensity on combustion characteristics, new flame factor model was developed. The principal study is the evaluation of interaction of swirl, tumble and unstrutural component of flow characteristics and correlation between turbulent intensity and flame factor. Computational and experimental study has been, performed such as quasi-dimensional cycle simulation, three dimensional flow analysis, engine performance test and diagnostic simulation. From these studies, it was found that flame factor was a function of engine speed and turbulent intensity.

  • PDF

Simulation of Turbidity Flow in the Andon-Imha Linked Reservoir System (안동-임하호 연결 시스템의 탁수유동 모의)

  • Park, Hyung Seok;Chung, Se Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.46-46
    • /
    • 2015
  • 강우가 지역별 계절별로 편중되어 있는 우리나라는 수자원의 안정적인 확보와 이용을 위해 다양한 형태의 댐을 건설하여 운영하고 있다. 그러나 대부분의 댐건설을 통해 형성된 저수지들은 탁수 장기화 및 녹조 발생 등의 환경, 생태적인 문제를 겪고 있으며, 그에 따른 사회적 우려로 인해 신규댐 건설을 통한 수자원확보는 더 이상 어려운 실정이다. 이러한 문제에 대응하기 위한 대안으로 기존 댐 저수지들(안동호-임하호)의 구조적 연계운영방안이 진행되고 있다. 본 연구의 목적은 2차원 CE-QUAL-W2모형을 활용하여 안동호와 임하호의 구조적 연결에 따른 탁수의 이동과 각 저수지 내에서의 유동 변화를 해석하는데 있다. 저수지 연계 시나리오는 EL. 138 m 위치에 길이 2 km, 직경 5.5 m 의 콘크리트관(마찰계수 0.05)이 안동호 좌안인 임동면 마리와 임하호 우안 망천리를 연결하는 것으로 가정하였다. 모델의 보정은 실측자료가 풍부한 2006년도 수문사상을 대상으로, 개별 저수지에 대해 수행하였고, 탁수 유동 시나리오 해석은 임하호에 심각한 탁수장기화 문제가 발생했던 2002년을 대상으로 댐 연계 탁수모의를 수행하였다. 안동호와 임하호의 댐 앞에서 모의값과 실측값을 오차를 분석한 결과 탁수예측오차는 AME 0.5~24 mg/L, RMSE 0.7~30.2mg/L의 범위로 비교적 실측값을 잘 반영한 것으로 나타났다. 임하댐의 경우 탁수층의 위치와 두께, 그리고 최고 탁도값을 적절히 재현 하였지만, 안동댐은 최고 탁도값 예측에서 다소 오차가 발생하는 것으로 나타났다. 안동호와 임하호 단독 운영시와 연계 운영시의 탁수변화 파악을 위해 초기 홍수사상이 발생한 8월 이후부터 저수지내의 TSS농도 분포를 비교하였다. 안동호의 경우 댐앞지점의 탁수분포는 수온성층구조에 영향을 받아, 단독 운영시(EL. 130 m)보다 연계운영시(EL. 140 m)에 탁수의 중심이 높은 위치에 형성되었다. 단독 운영시 10월 이후에 전도현상으로 인해 침강되지 않은 잔류 탁수층이 저수지 하부로 확산되었지만, 연계 운영시에는 재부상 되어 상층으로 확산되는 것으로 모의되었다. 또한 연계운영시 유량이동으로 인해 안동호의 탁수 댐앞 도달시간이 짧아지는 것으로 나타났다. 반면 임하호는 연계 운영시 안동댐으로 유출이 생기면서 중층에서 탁수량이 저감되는 것으로 모의되었다. 저수지 내 탁수량 분석을 위해 SS 15 mg/L 이상의 잔류 탁수량을 분석한 결과, 연계운영시 안동호의 평균 잔류탁수량 비율은 11.8% 증가, 임하호의 경우 11.7% 감소하였다. 또한, 탁수의 댐하류 방류일수도 SS 15 mg/L 기준 임하호 9일 저감, 안동호는 70일 증가하여 임하호의 탁수가 안동호의 탁수 장기화에 영향을 주는 것으로 나타났다.

  • PDF

A study on theory analysis and CFD simulation for design of high efficiency ceramic exchanger (고효율 세라믹 열교환기 설계를 위한 이론해석 및 CFD시뮬레이션에 관한 연구)

  • Park, Kyung-Seo;Choi, Chong-Gun;Nam, Jin-Hyun;Shin, Doog-Hoon;Jung, Tae-Yong;Park, Sang-Hwan;Kim, Chang-Sam
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.179-186
    • /
    • 2008
  • 현재 대부분의 산업용 열기관은 효율을 높이기 위하여 연소에 사용되는 공기를 예열하는 방법을 사용한다. 하지만, 산업용 열기관에서 평균적으로 발생되는 $1000^{\circ}C$ 이상의 배기가스는 일반 금속 열교환기에는 적합하지 않다. 이에 반해 세라믹 열교환기의 경우 고온에서 견디는 장점이 있다. 본 연구에서는 기본적인 열교환기 설계 이론을 이용하여 설계프로그램을 제작하였다. 또한 세라믹 열교환기 내 열 유체 거동을 CFD 상용코드인 FlUENT 6.2를 이용한 전산해석을 수행하여 설계결과를 비교 검증하였다. 설계 결과에서 휜의 형태 변화에 따라 열전달율과 온도구배는 무시할 수 있을 정도로 작았으나, 압력강하는 크게 변동되는 결과가 도출되었다. 제한된 모듈 크기에서 휜 간거리는 휜의 두께에 비해 약 3배 이상 클 경우가 적당하며, 판(plate)의 두께는 작을수록 압력손실이 적고, 열전달율이 상승하지만 두께가 너무 얇게 된다면 제작상의 어려움이 생긴다. 향후 연구에서는 단순한 구조에서 벗어나 off-set이나 판형구조를 고려하여 설계함으로서 열전달 면적을 넓히거나 난류유동을 발생시켜 열전달율을 높이는 연구를 진행 할 필요가 있다.

  • PDF

Flow Mechanism around Air Flow Sensor of Electronic Control Engine (전자제어 엔진의 공기유량센서 유동구조 연구)

  • 이종춘;황성만;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.486-493
    • /
    • 2000
  • Flow mechanism around air flow sensor of electronic control engine, especially Karman vortex type, was investigated experimentally. The two-dimensional flow characteristics in the intermediate wake region behind a triangular vortex-generator respectively apex forward facing, apex backward facing and vertical flat plates following after apex forward facing(i.e vortex-flowmeter) were investigated at Reynolods number of $ReH=1.4\times10^4$; H is the width of a triangular vortex-generator. The vortex shedding frequency for wide Reynolds number from $7\times10^3$ to $2.1\times10^4$ was also surveyed. The velocity component was measured by X-type hot wire anemometer at 8H downstream from the bluff body. The coherent structure of the intermediate wake behind a bluff body was obtained by conditional phase average technique. As a result, it was verified that the vertical flat plates following after apex forward triangular vortex-generator make not only more linear relation between free stream velocity and vortex shedding frequency but also more periodic vortex in the vicinity of the center of wake.

  • PDF

Investigation of a Thermal Stress for the Unit Cell of a Solid Oxide Fuel Cell (고체산화물 연료전지 단위셀의 열응력에 관한 연구)

  • Kim, Young-Jin;Park, Sang-Kyun;Roh, Gill-Tae;Kim, Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.414-420
    • /
    • 2011
  • Thermal stress analysis of a planar anode-supported SOFC considering electrochemical reactions has been performed under operating conditions where average current density varies from 0 to 2000 $A/m^2$. For the case of the 2000 $A/m^2$ operating condition, Structural stress analysis based on the temperature distributions obtained from the CFD analysis of the unit cell has also been done. From this one way Fluid-Structure Interaction(FSI) analysis, Maximum Von-Mises stress under negligible temperature gradient fields occurs when cell components are perfectly bonded. The maximum stress of the electrolyte, cathode and anode in a unit cell SOFC is 262.58MPa, 28.55MPa and 15.1MPa respectively. The maximum thermal stress is critically dependent on static friction coefficient.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF

Hydrography and Circulation in the Youngsan River Estuary in Summer, 2000 (2000년 여름 영산강 하구의 해수 특성과 순환)

  • Cho, Yang-Ki;Cho, Cheol;Sun, Youn-Jong;Park, Kyung-Yang;Park, Lae-Hwan
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.6 no.4
    • /
    • pp.218-224
    • /
    • 2001
  • Water movement in the Young San River Estuary where a sea dyke was constructed, was observed using anacoustic doppler profiler (ADP) and two TGPS buoys for 25 hours on 27-28 July 2000. Hydrographic observations were simultaneously taken using CTD to understand the characteristic of the spacial structure of temperature and salinity. A large quantity of fresh water was discharged from the sea dyke on 26 July 2000. The observation period fell on neap tide. The amplitude of the tidal elevation and the maximum velocity of the tidal current were about 4 m and 12 cm/sec respectively. The water movement at the surface layer is mainly controlled by wind, and those at the other layers are controlled by semidiurnal tide. The low salinity water less than 22 psu was observed along the northern part during the early observation period while southerly wind prevails. The less saline water moves westward and finally leaves the estuary by easterly wind early on the second day. We can divide the vertical structure into four layers by hydrography and current structure. Mean velocity structure shows that relatively less saline waters at the surface and the middle layer move seaward, and the waters at the upper and the bottom layers move landward. It is thought that the intermittent discharge of river water from the sea dyke makes vertical structure of four layers.

  • PDF