• Title/Summary/Keyword: 평가 기준장비

Search Result 441, Processing Time 0.028 seconds

A Study on the Characteristics of SM570TMC Plates in Compression Members (SM570TMC 강재의 압축재 특성에 관한 연구)

  • Im, Sung Woo;Kim, Yo Suk;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.357-363
    • /
    • 2005
  • There is a great need for high-strength steel especially for the high-rise steel building structure. High-strength steels, however, may have mechanical properties that are significantly different from those of the conventional steels. The application of high-strength steels to building structures should be reviewed as to whether the inelastic behavior equivalent to that of conventional steels can be attained or not. In this study, SM570TMC steel was tested to evaluate buckling strength under axial compressive force. The comparison tests for local buckling strength evaluation of box-type and H-shaped welded columns were performed with variable width-thickness ratios. As for the experimental check, the maximum strength of stub column was determined by local buckling as far as the limit of width-to-thickness ratio was satisfied with current design codes. Also, the strength of the stub column did not decrease suddenly by local buckling before maximum strength even when the ratio is not satisfied. The buckling strength of SM570TMC steel was higher than both ASD (Allowable Stress Design) and LRFD (Load and Resistance Factor Design) specifications.

Design Method to Control Wind-Induced Vibration of High-Rise Buildings Using Resizing Algorithm (재분배기법을 이용한 고층건물의 풍응답 가속도 조절 설계기법)

  • Seo, Ji-Hyun;Park, Hyo-Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.465-473
    • /
    • 2010
  • As increase of height and slenderness of buildings, serviceability design criteria such as maximum lateral drift and wind-induced vibration level play an important role in structural design of high-rise buildings. Especially, wind-induced vibration is directly related to discomfort of occupants. However, no practical algorithm or design method is available for structural designers to control the acceleration level due to wind. This paper presented a control method for wind-induced vibration of high-rise buildings using the resizing algorithm. The level of vibration due to wind is calculated by well known estimation rules of ASCE 7-02, NBCC 95, SAA83, and Solari method. Based on the fact that the level of wind-induced vibration is inversely proportional to the magnitude of natural periods of buildings, in the design method, natural periods of a high-rise building are modified by redistribution of structural weight according to the resizing algorithm. The design method is applied to wind-induced vibration control design of real 42-story residential building and evaluated the efficiency and effectiveness.

The Noise Characteristics and Appropriate Talk Distance in Dental Clinic (치과병원의 소음특성과 적절한 대화거리)

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2516-2523
    • /
    • 2013
  • Noise occurred when medical treatment in dental clinic will affect the patients. This study was measured the noise level and frequency in case of medical examination and also has evaluated the degree of indoor noise using the NR-curve, NRN and a distance to conversation between worker and patients using the PSIL. It shows that noise level was 69.3~81.5dB(A) and frequency was very high (more than 4K(Hz)) and analysis by NR-curve showed that it was exceed the noise permit level and distance to conversation was less than 1meter by PSIL. To remedy a fear of noise in patients and provide a conversational satisfaction, it's considered that choosing the low noise-vib. equipment, using the masking effect and set the room to explain. So It is possible to improve their competitiveness.

Study on the Compatibility for an Ir-192 Source Manufactured by Korea Atomic Energy Research Institute (KAERI) in GammaMed Brachytherapy Machine (한국원자력연구소에서 개발한 Ir-192 선원의 감마메드 치료기 호환성 연구)

  • Jeong, Dong-Hyeok;Lee, Kang-Kyoo;Kim, Soo-Kon;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.78-85
    • /
    • 2010
  • The compatibility with GammaMed-12i brachytherapy machine for an Ir-192 encapsulated source (IRRS20, KAERI, Korea) manufactured by Korea atomic energy research institute (KAERI) has been investigated. As a mechanical testing of compatibility, precise measurement of step movement with channels, measurement of curvature of radius for wire, and emergency return testing were performed. Periodic measurements of air kerma strength for 45 days were carried out to evaluate decay characteristics of Ir-192 radioisotope and comparison of dose distributions in phantom between KAERI and old sources previously used were performed by film dosimetry. KAERI source has a good compatibility with GammaMed12i machine as a result of mechanical testing. There are in good agreement with calculated values in activity characteristics and there were small differences in dose distributions around the source in comparison between KAERI and old source.

Fabrication of Biomimetic MEMS Acoustic Sensor and Analysis of Its Frequency Characteristics (MEMS 기반 생체모사 음향센서 제작 및 주파수 특성 분석)

  • Hur, Shin;Jung, Young-Do;Lee, Young-Hwa;Song, Won-Joon;Kim, Wan-Doo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.522-528
    • /
    • 2011
  • Artificial basilar membranes made of PVDF(polyvinylidene fluoride) are manufactured using microfabrication processes. The mechanical behavior of PVDF artificial basilar membrane was measured to evaluate its performance as a mechanical frequency analyzer using scanning LDV(laser Doppler vibrometer). The experimental setup consists of the microfabricated artificial basilar membrane, a loud speaker connected to an amplifier for generating acoustic pressure of specific spectral pattern, and a scanning LDV with controlling unit for measuring the displacement of the membrane on the incoming acoustic stimulation. The microfabricated artificial basilar membrane was attached tightly upon a package containing a chamber which can be filled with silicone oil before placed on the experimental setup stage. The experiment results showed that the microfabricated artificial basilar membrane has a property as a mechanical frequency analyzer.

Applicability Study on Deep Mixing for Urban Construction (심층혼합처리 공법의 도심지 공사 적용성 연구)

  • Kim, Young-Seok;Choo, Jin-Hyun;Cho, Yong-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.500-506
    • /
    • 2011
  • The deep mixing method, which is generally considered as a method for improving soft ground, is assessed in terms of its applicability for urban construction. Using small equipment tailored to perform deep mixing in congested urban areas, deep mixing was performed to reinforce the foundation ground of a retaining wall in a redevelopment site in Seoul. Strengths characteristics, construction vibrations and displacements induced to an adjacent old masonry wall were evaluated by laboratory tests and field monitoring. The results indicate that the strength of ground was improved appropriately whilst the vibrations and displacements induced by deep mixing were slight enough to satisfy the general requirements for construction works in urban environments. Therefore, it is concluded that deep mixing method can be a practical option for foundation methods in urban construction works where minimizing noise and vibrations is an important concern.

The Presenting Visual acuity and Satisfaction of Visual Acuity Tests on Health Checkups in Korean Adults (건강검진으로 본 한국 성인의 시력 실태 및 시력검사 만족도)

  • Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.741-749
    • /
    • 2010
  • The aim of this study was to survey the presenting visual acuity (VA) and satisfaction of VA tests in health checkups and to suggest ways in which eye care can be improved. VA data were obtained from the results of the health checkups for Korean adults in 2002-2007. Satisfaction questionnaires were administered via direct interview with 173 participants who had health checkups. The prevalence of VA 0.5-1.4 was 76.24%. Women had a higher prevalence than men below VA 0.9 and men had a higher prevalence than women above VA 1.0. The change in VA with age had a tendency to decrease after forties. Findings for satisfaction of VA tests on health checkups showed a level of neutral agreement. In order to enhance satisfaction, it is important that vision testing should provide examinees with referral criterion and follow-up VA results. It is also necessary to have comprehensive eye examination and utilize optometric instruments and professional examiners.

Dynamic Properties for Geomaterials of Railway as Determined by Large-scale Cyclic Triaxial Test (대형삼축압축시험을 이용한 철도노반재료의 동적 물성 제안)

  • Lee, Sung Jin;Hwang, Su Beom;Lee, Su Hyung;Lee, Seong Hyeok;Kim, Ki Jae
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.1
    • /
    • pp.43-51
    • /
    • 2014
  • In the earth structures of railways, large coarse granular materials are widely used as fill materials. However, experimental studies that consider the dynamic properties of these coarse granular materials have rarely been carried out in Korea due to the lack of a large scale test apparatus in this country. In this study, large scale cyclic triaxial tests were carried out for materials such as reinforced roadbed (subballast, graded crushed stone), transition zone gravel, and the upper subgrade of a railway. These specimens were prepared according to certain conditions (dry unit weight, grain size distribution, and so on) specified in the Korea railroad design standard. Based on these large triaxial test results, normalized shear modulus and damping ratio curves according to small strain level are suggested. A model and coefficients for each material are also proposed.

Development and usability evaluation of EEG measurement device for detect the driver's drowsiness (운전자의 졸음지표 감지를 위한 뇌파측정 장치 개발 및 유용성 평가)

  • Park, Mun-kyu;Lee, Chung-heon;An, Young-jun;Ji, Hoon;Lee, Dong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.947-950
    • /
    • 2015
  • In the cause of car accidents in Korea, drowsy driving has shown that it is larger fctors than drunk driving. Therefore, in order to prevent drowsy driving accidents, drowsiness detection and warning system for drivers has recently become a very important issue. Furthermore, Many researches have been published that measuring alpha wave of EEG signals is the effective way in order to be aware of drowsiness of drivers. In this study, we have developed EEG measuring device that applies a signal processing algorithm using the LabView program for detecting drowsiness. According to results of drowsiness inducement experiments for small test subjects, it was able to detect the pattern of EEG, which means drowsy state based on the changing of power spectrum, counterpart of alpha wave. After all, Comparing to the results of drowsiness pattern between commercial equipments and developed device, we could confirm acquiring similar pattern to drowsiness pattern. With this results, the driver's drowsiness prevention system expect that it will be able to contribute to lowering the death rate caused by drowsy driving accidents.

  • PDF

Measurement of Channel Impedance Characteristics for Indoor Power Line Communications (옥내 전력선 통신 채널 임피던스 특성 측정)

  • Heo Yoon-Seok;Kim Chul;Hong Bong-Hwa;Lee Dae-Young;Jun Kye-Suk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.79-86
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency $30khz\~1Mhz$ band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.