• Title/Summary/Keyword: 평가시설

Search Result 4,447, Processing Time 0.042 seconds

Convergence Models of Evaluation Systems for Social Welfare Facilities (사회복지시설 평가제도의 융합모형)

  • Song, Min-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.115-122
    • /
    • 2015
  • The social welfare facilities are trusted by the government for the development of appropriate welfare services and their delivery systems. They aim to provide people with professional social welfare services and, for this purpose, they develop ways to effectively operate facilities and to deliver the services efficiently. So far, the five consecutive evaluations based on the Social Services Act have suggested the effective and systematic ways of operating social welfare facilities. Through these efforts, they established an important basis for the balanced development and further advancement of social welfare facilities. Nevertheless, people have continually pointed out problems concerning the evaluation system of social welfare facilities. Accordingly, these problems have the necessity of investigation for reformed directions by means of effective control and evaluation system for the operation of social welfare facilities. Therefore, this study aims to suggest convergence models for improving the social welfare facilities evaluation system.

Evaluation of Performance Index for Optimization of Food Waste Treatment and Recovery Facility (음식물류폐기물 자원화시설 최적화를 위한 이행지표 평가)

  • Kim, Jong-Hwan;Park, Joon-Seok;Phae, Chae-Gun
    • Clean Technology
    • /
    • v.22 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • This research was performed to evaluate the food waste recovery facility using optimization performance index. In 2014, the generated amount of food waste occupied approximately 27% in total municipal solid waste. The 97.2% of the food waste was recycled and the others were treated through landfill and incineration in the portion of 0.9% and 1.9%, respectively. In food waste recovery facilities of year 2014, the composting and feed facilities were 49.5% and 22.9%, respectively. The feed facility showed higher scores in all technological, environmental, and especially economical evaluations than those of composting facility. As results of overall optimization performance index, the feed facility has higher score of 61.5 than 52.7 of composting facility. It was demonstrated that the feed facility has the advantage, compared with the composting facility.

Policy Directions to Build on Nature-Friendly Park Facilities - Based on an Evaluation on the Nature-Friendliness of Park Facilities in National Parks - (자연친화적인 공원시설 설치를 위한 정책방향 - 국립공원 공원시설의 자연친화성 평가를 근거로 -)

  • Park, Chang-Sug;Bae, Min-Ki;Kim, Tae-Jin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.5
    • /
    • pp.1-12
    • /
    • 2009
  • The purpose of this research was to propose policy directions for the design and construction of nature-friendly park facilities (PF) in national parks. In order to do that, nature-friendliness evaluation indicators(NEIs) used in green building rating systems and related articles were reviewed. After the initial literature review was complete, NEIs for park facilities based on location, design, construction, operation, and management sectors were developed. Data was obtained through a questionnaire completed by 79 managers at 19 national parks in Korea in 2008. The answers were analyzed using descriptive statistical methods, a t-test, a multi-dimensional analysis, and a factor analysis. This research found that: 1) The results indicated that based on relative weight calculation, the location condition was evaluated as the most important; 2) The evaluation results regarding the degree of nature-friendliness of park facilities showed that location condition was ranked higher than design and construction--in addition, the evaluated values of indicators related to energy efficiency were ranked the lowest; 3) the level of nature-friendliness of shelter was given the highest level, but resting facility was the lowest level; 4) Overall, park facilities at Mt. Seorak, Mt. Odae, and Taean Coast national parks showed high levels of nature-friendliness. But park facilities at Mt. Gyeongju and Mt. Songni national parks showed low levels of nature-friendliness. The results of this research shall contribute to the establishment of tailor-made management policies, the development of detailed guidelines for increased energy efficiency and visitor satisfaction, and the preservation of ecosystems and natural resources in Korea's national parks.

Performance Evaluation for Deteriorated Masonry of Military Facilities (조적조 노후 군시설의 성능평가기준)

  • Yang, Eun-Bum;Shin, Jong-Hyun;Lee, Chan-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.167-174
    • /
    • 2003
  • Military facilities with masonry have a great portion in the whole military facilities. But lots of them have been used for more than 20 years, the degree of deterioration of the facilities are serious. Futhermore, as insufficient budget for the facilities maintenance and poor maintenance, the performance of the aged masonry facilities have continually decreased. We suggest a structural performance assessment criteria for the military facility through literature review, interview with experts and questionnaire. The major assessment factors for the structural performance include the inclining and sinking degree of the facilities, durability of materials and resisting force of the structural members.

Performance Evaluation for Deteriorated Masonry in Military Facilities (조적조 노후 군시설의 성능 평가)

  • Yang Eun-Bum;Shin kyoung-Hee;Hwang Jong-Hyun;Kim In-Ho;Kim Yong-In;Park Tae-keun;Lee Chan Shik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.434-438
    • /
    • 2001
  • Military facilities with masonry construction have a great portion in the whole military facilities. But lots of them have been used for more than 20 years, the degree of deterioration of the facilities are very serious. Futhermore, as small budget for the facilities maintenance and poor maintenance, the performance of the aged masonry facilities have continually decreased. We suggest a structural performance assesment criteria for the military facility through literature review, interview with experts and questionnaire. The assesment of structural performance includes the inclining and sinking degree of the facilities, durability of materials and resisting force of the structural members.

  • PDF

A Study on the Vulnerability Assessment of Solar Power Generation Facilities Considering Disaster Information (재해정보를 고려한 태양광발전시설의 취약성 평가에 관한 연구)

  • Heejin Pyo
    • Land and Housing Review
    • /
    • v.15 no.2
    • /
    • pp.57-71
    • /
    • 2024
  • This study aims to develop an evaluation method for solar power facilities considering disaster impacts and to analyse the vulnerabilities of existing facilities. Haenam-gun in Jeollanam-do, where the reassessment of existing facilities is urgent, was selected as the study area. To evaluate the vulnerability from a more objective perspective, principal component analysis and entropy methods were utilised. Seven vulnerability assessment indicators were selected: maximum hourly rainfall, maximum wind speed, number of typhoon occurrence days, number of rainfall days lasting more than five days, maximum daily rainfall, impermeable area ratio, and population density. Among these, maximum hourly rainfall, maximum wind speed, maximum daily rainfall, and number of rainfall days lasting more than five days were found to have the highest weights. The overlay of the derived weights showed that the southeastern regions of Haenam-eup and Bukil-myeon were classified as Grade 1 and 2, whereas the northern regions of Hwawon-myeon, Sani-myeon, and Munnae-myeon were classified as Grade 4 and 5, indicating differences in vulnerability. Of the 2,133 facilities evaluated, 91.1% were classified as Grade 3 or higher, indicating a generally favourable condition. However, there were more Grade 1 facilities than Grade 2, highlighting the need for countermeasures. This study is significant in that it evaluates solar power facilities considering urban disaster resilience and is expected to be used as a basic resource for the installation of new facilities or the management and operation of existing ones.

Case Studies of Domestic and Foreign Photovoltaic Integrated Projects (국내.외 PV 통합 프로젝트의 사례분석)

  • Yoon, Sung-Won;Kim, Hye-Seong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.6
    • /
    • pp.85-94
    • /
    • 2008
  • This paper is concerned with the domestic and foreign PV integrated projects in view of structural design. These projects are classified with public and display 6 facilities. The evaluated items are natural integration with building, engineering details and innovative new design. 6 domestic public and display facilities are frequently using isolated supporting system at roof, but show weakness in design integration. But the cases, using the PV panel in the stage of design some display facilities, are increasing. In the other hand, foreign public and display facilities are using the modul connection majorly and the structural and design integration are obtained.

  • PDF

A Study on the Improvement of Evaluation Items for Customized BF Certification in School Facilities -Focusing on the Delphi survey- (학교시설 맞춤형 BF인증을 위한 평가항목 개선방향에 관한 연구 -델파이조사를 중심으로-)

  • Maeng, Joon-Ho;Kim, Sung-Joong;Song, Byung-Joon;Kim, Jae-Young;Yun, Pyeong-Se
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.22 no.2
    • /
    • pp.1-16
    • /
    • 2023
  • This paper reports on three Delphi surveys based on draft evaluation items with the aim of deriving evaluation items prior to developing a BF certification index for school facilities in order to make the index safe and convenient. To this end, problems were formulated using content analysis and follow-up evaluation of existing BF certification indicators. Draft BF certification evaluation items for school facilities were proposed. The adequacy of each evaluation item was verified using a Delphi survey. Experts and working-level groups, such as university professors, architects, public officials, certification agencies, and organizations for disabled persons, provided feedback for all evaluation items for school facility BF, which was incorporated in the final evaluation items. As a result of the Delphi surveys, in addition to the existing 8 evaluation items, a total of 75 evaluation items were proposed as maintenance items, 12 as improvement review items, and 15 as new evaluation items.

A Study to Develop an Efficiency Analysis Model to Aids to Navigation (ANEffic) : Manned Lighthouses (항로표지시설 효용성분석 모델(ANEffic) 개발에 관한 연구 - 유인등대에 적용하여)

  • Park, Hye-Ri;Gug, Seung-Gi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.6
    • /
    • pp.647-653
    • /
    • 2016
  • There are no ex-port evaluations for the propriety and efficiency of AtoNs considering risk elements and environmental changes after the opening of a port. It is necessary to develop objective indicators and evaluation models to fill this gap. This study establishes an efficiency analysis model for Aids to Navigation (ANEffic) focusing on manned lighthouse, which include 20 function indices. After running a function assessment, an Analytic Hierarchy Process (AHP) and Likert scale are used to address port operations, national policies and expert opinions. As the result of the assessment, Yeongdo, Gageodo, Geomundo and Jukbyun Lighthouses are highly regarded in the propriety and efficiency of AtoN. And Uleungdo, Gasado, Songdaemal and Ulgi Lighthouses need to review detailed evaluations. The ANEffic developed should be utilized as basic tool to collect data for efficient management and to re-arrange the policy decisions regarding AtoNs as appropriate.

A Study on the Performance Comparison of S2 type Bridge Rails (S2급 교량용 방호울타리의 성능비교 연구 (F형 콘크리트와 철재 교량용 방호울타리를 중심으로))

  • 정봉조;주재웅;이성관;장명순
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.2
    • /
    • pp.117-124
    • /
    • 2002
  • 새로 개발한 철재 교량용 방호울타리는 기존 시설에 비해 충격흡수기능과 조망권 확보, 융설작업, 유지보수가 용이하도록 설계되었다. 본 연구는 새로 개발한 철재 교량용 방호울타리를 건설교통부의 $\ulcorner$도로안전시설 설치 및 관리지침 - 교량용 방호울타리 편. 1999$\lrcorner$ 의 설계기준에 따라 기존 고속도로에 사용하고 있는 F형 콘크리트 교량용 방호울타리와 성능비교를 통해 평가하고자 하였다. 비교평가는 S2급 교량용 방호울타리의 시험기준으로 실시하였으며 결과는 다음과 같이 나타났다. 첫째, 소형승용차를 대상으로 한 운전자의 안전도 평가에서는 두가지 시설 모두 강도성능, 충돌 후 차량 안전성능 구성 부재 비산 억제 성능 등 세 가지 기준을 만족하였으나, 가속도 기준에 있어서는 철재 교량용 방호울타리는 기준인 20g 이하인 18.2605g로 나타나 안전기준을 만족하였고, F형 콘크리트 교량용 방호울타리는 20.1791g로 나타나 기준을 약간 상회하는 것으로 나타났으나 안전기준의 범위에 있는 것으로 평가하였다. 둘째. 대형차량을 대상으로 한 방호울타리의 구조적 안정성 평가에 있어서는 F형과 철재 교량용 방호울타리 모두 평가기준에 적합한 것으로 나타났다. 새로 개발한 철재 교량용 방호울타리는 국내 최초로 모의충돌시험과 실물차량 충돌시험을 통해 개발하였다는 의의를 가지고 있으며 성능측면에서도 기존의 시설에 비해 충분히 안전하다는 것을 증명하였다. 그러나 측정시설의 미비로 충돌후의 차량의 이탈속도나 이탈각도에 대하여 만족할 만한 수준의 결과를 제시하지는 못하였다.