• Title/Summary/Keyword: 펌프실 면적

Search Result 9, Processing Time 0.029 seconds

Determination of Sizes of the Pump Rooms in Korean Nuclear Power Plants (한국형 원자력발전소 펌프실 면적 산정 방안)

  • Lee, Hyo-Sung;Koh, Churl-Kyun;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.36-41
    • /
    • 2013
  • For areas installed with one pump, the trend for expected sizes of pump room areas is observed once pump power and floor dimensions are provided. However, these pump rooms with auxiliary charging pumps, turbine driven auxiliary feedwater pumps, and pump rooms with a separate valve room have unique ways to determine the pump room area. No definite trends are identified for areas installed with two pumps using pump power and floor dimensions. The relationship between pump power and floor dimensions is also unable to be found.

  • PDF

Simulation & Validation of Lubricating Oil Fire in Nuclear Power Plant Pump Room (원전 펌프실 윤활유화재 분석 및 확인에 관한 연구)

  • Park, Jong-Seuk;Park, Yoon-Jeong;Lee, Chang-Joo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.241-245
    • /
    • 2010
  • 화재방호에 성능기반 개념을 도입함에 따라 화재모델링의 활용도는 점점 높아지고 있다. 본 연구의 목적은 FDS를 이용하여 원자력발전소 펌프실의 윤활유 화재 시 케이블의 손상여부를 평가하고, 확인분석을 통해 화재모델링의 적합성을 파악하는 데 있다. 화재는 펌프 주변의 누출된 윤활유에서 발생하며 화원의 면적은 $2.75m^2$이고 단위면적당 열방출율은 $1,794kW/m^2$로 가정하였다. 계산결과, 고온기체층의 온도는 $400^{\circ}C$를 상회하고 있으나 케이블 트레이의 온도는 $50^{\circ}C$ 아래로 예측되고 있어 본 화재시나리오에서 케이블의 건전성은 유지되고 있으며 밀폐된 격실에서의 대형화재는 환기지배형 화재가 된다는 것을 보여주고 있다. 또한 확인분석 결과, 화재 시나리오의 주요 변수인 열방출율, 격실크기 그리고 강제 환기 변수가 확인계산 범위 내에 있어 본 계산결과는 NUREG-1824의 확인요건을 만족하고 있다. 따라서 펌프실 윤활유 화재에 대한 모델링의 적합성을 확인하였다.

  • PDF

An Analysis of Attenuation Effect of Pressure Head Using an Air Chamber (공기실을 사용한 압력수두의 완화효과에 대한 분석)

  • Lee, Jae-Su;Yun, Yong-Nam;Kim, Jung-Hun
    • Water for future
    • /
    • v.28 no.5
    • /
    • pp.141-150
    • /
    • 1995
  • An air chamber is designed to keep the pressure from exceeding a predetermined value, or to prevent low pressures and column separation. Therefore, it can be used to protect against rapid transients in a pipe system following abrupt pump stoppage. In this research, an air chamber was applied to a hypothetical pipe system to analyze attenuation effect of pressure head for different air volumes, locations, chamber areas, coefficients of orifice loss and polytropic exponents. With an increase of air volume, the maximum pressure head at pump site is decreased and the minimum pressure head is increased. For different locations and areas of the chamber, the attenuation effects do not show much difference. Also, as the orifice loss coefficient increases, the maximum pressure head is decreased. For different polytropic exponents, isothermal process shows lower maximum pressure head than that of the adiabatic process.

  • PDF

칼로리미터의 재생 냉각유로 설계

  • 조원국
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.9-9
    • /
    • 1999
  • 액체로켓 엔진의 분사기와 연소실 설계에 사용될 재생냉각형 칼로리미터의 냉각유로를 설계하였다. 사용할 펌프의 수두는 5기압이며 이로써 끓는점 아래에서 작동할 수 있고 동시에 넓은 냉각 면적을 가지는 유로의 형상을 결정하였다. 유로에서의 압력강하와 온도분포는 전산유동해석에 의하여 구하였고 열부하는 기존의 연소 해석과 1차원해석에 의한 결과를 적용하였다. 해석결과로서 유로의 폭이 4mm에서 2.5mm까지 2단계로 줄었다가 다시 2단계로 늘어나는 냉각유로를 설계하였으며 이 때 높이는 2mm로 일정하게 유지하였다. 유량 변화에 의한 레이놀즈 수는 1.9$\times$$10^4$, 2.4$\times$$10^4$, 2.9$\times$$10^4$이며 세 경우 모두 주어진 펌프수두 이내의 압력강하를 보였으나 온도상승과 성능상의 여유를 고려하여 레이놀즈 수 2.4$\times$$10^4$인 경우를 최종 설계안으로 결정하였다.

  • PDF

Development of Numerical Model for Unsteady Flow Analysis jin Discharge Culvert of Thermal Power Plant: II. Model Application (열발전소 배수암거 부정류해석 수치모형의 개발 : II. 모형의 적용)

  • Yun, Seong-Beom;Lee, Gi-Hyeok
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.769-776
    • /
    • 1997
  • The behavior of surge induced in the discharge system of the thermal power plants by the sudden stop of cooling water pump is analyzed using the numerical model developed by Yoon and Lee (1997). Various effects, which are ignored earlier, such as discharge from internal system, air chamber and air inlet of seal well, monholes, open channel and sea are included. These effects of the surge behavior are systematically analyzed. Especially, the surge control effect and air pressure change in the air chamber associated with the area of air inlet are presented for easy application in practice.

  • PDF

SimulationX®-based Modeling for Valve-Plate Notch Design of Variable Swash-Plate Axial Piston Pump (SimulationX®를 이용한 가변 사판식 액셜 피스톤 펌프의 밸브플레이트 노치 최적화에 관한 연구)

  • Lee, San Seong;Chung, Won Jee;Lim, Dong Jae;Cha, Tae Hyung;Kim, Soo Tae;Lee, Jeong Sil;Choi, Kyung Shin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.104-112
    • /
    • 2018
  • Considering the shape of a valve plate in design is important for reducing the pulsation phenomenon, which is a negative factor in pump performance. The purpose of this study is to propose an optimized method for a valve-plate V-type notch of a piston pump by modeling and simulation. The method uses $SimulationX^{(R)}$, a commercial hydraulic analysis program, and to provide data for the designing of the notch. The opening areas are determined by performing kinematic analysis of the notch part where the opening area changes rapidly. After applying the result analysis, the main effects on maximum pressure pulsation and maximum backflow according to the notch design factors are analyzed by using the full factorial method of experimental design. The optimized solutions are derived for the notch design variables, based on the analyzed data.

Experimental Investigation of Performance for Supersonic Impulse Turbine (초음속 충동형 터빈의 성능에 대한 시험적 고찰)

  • Lee, Hang-Gi;Jeong, Eun-Hwan;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.561-565
    • /
    • 2009
  • The performance of supersonic impulse turbine was investigated experimentally. Experiment was performed with the compressed air instead of the high temperature burned gas because of the limitation of test facility and danger. As a result of the experiment with the compressed air, the performance in the real gas(burned gas) was predicted by the similarity method. The nozzle area of prototype turbine was calculated based on the real gas. So, it is difficult to satisfy the similarity conditions completely. Two similarity conditions were set and the design point for real gas was existed between two similarity conditions. And, the new turbine test model with calculated nozzle area based on the compressed air was tested. Therefore, similarity point of the new turbine test model was also existed between above two similarity points. It means that the design point for real gas was similar to the test point with the new turbine model.

  • PDF

Experiment of Discharge Supply Verification in River Experiment Center (하천실증연구센터 공급 유량 검증 실험)

  • Kim, Jong Min;Lee, Du Han;Kim, Sung Joong;Kim, Hyung Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.77-77
    • /
    • 2018
  • 한국 건설기술연구원의 하천실증연구센터는 기존에 불가능했던 준 실규모 하천실험, 생태실험, 치수분야 대형 모형실험 및 하천관련 기준수립을 위한 치수분야 수요와 하천 구조물의 품질성능평가 등을 목적으로 설립된 대규모 하천실증연구센터이다. 안동 하천실증연구센터는 총면적 $193,051m^2$의 부지에 하천의 일반적인 형상을 갖고 있는 완경사, 급경사, 만곡수로가 있으며, 수리량 측정 실험을 위한 초음파 유속계, 프로펠러 유속계, 전자식 유속계 등의 유속 측정 장비를 보유하고 있고, Total Station, Lidar, RTK-GPS 등 지형 측량에 사용할 수 있는 장비들도 보유하고 있어, 하천관련 실험을 수행하기에 충분한 여건을 보유하고 있다. 하천실증연구센터는 2013년부터 내 외부활용에서 활용할 수 있도록 지원을 수행하였으며, 총 118건의 하천 수리 및 생태분야, 지반분야 등 다양한 토목분야의 연구자들이 하천실증연구센터를 방문하여 실험을 수행하였고, 국내 기관 및 대학뿐만 아니라 미국의 Iowa 대학, Idaho 대학, USGS, 네덜란드 Deltares, 프랑스 Irstea 등 외국의 대학 및 기관에서도 방문하여 실험 및 공동연구를 수행하였다. 안동 하천실증연구센터의 활용 범위와 활용 건수가 지속적으로 증가함에 따라 자체적인 검토 및 외부의 의견에 따라 센터의 실험시설에 대한 개선이 필요한 사항이 발생하게 되었다. 하천실증연구센터의 수로는 기존의 지반위에 성토를 하여 인공적으로 건설하였기 때문에 일반적인 실내의 실험수로와는 다르게 하상에서의 침투가 발생하며, 이에 따라 하류방향으로 흐름이 진행될수록 유량의 변동이 발생하게 된다. 이에 따라 침투로 인해 발생하는 유량의 변동이 하도 유량 공급의 안정화에 미치는 영향에 대한 신뢰성 검증의 필요성이 필요하다고 판단되어 펌프에서의 유량 공급 및 하도내에서의 유량 안정화에 대한 검증 실험을 수행하고자 한다. 유량 공급에 대한 검증 실험은 크게 두 단계로 구성하였다. 첫 번째 단계는 펌프의 유량 공급에 대한 검증실험을 수행하고, 두 번째 단계에서는 동일한 조건내에서 하류의 지하수 수심, 공급수조의 수심, 하도내의 수심과 ADV 및 ADCP로 측정된 유량과의 관계를 통해 하도내의 유량이 얼마나 일정하게 공급되고, 하류방향으로 갈수록 유량 손실의 경향에 대한 실험을 계획하였으며, 전체적인 실험은 장기적으로 각 수로에 대하여 수행하는 것을 목표로 하였으며, 본 실험단계에서는 완경사 수로를 대상으로 하였다.

  • PDF

End Point Temperature of Rewarming and Afterdrop After Hypothermic Cardiopulmonary Bypass in Pediatric Patients (소아에서의 저체온 심폐바이패스후 재가온 종료온도와 후하강)

  • Kim, Won-Gon;Lee, Hae-Won;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.125-130
    • /
    • 1997
  • Separating the patient from hypothermic cardiopulmonary bypass(CPB) before achieving adequate rewarming often results in afterdrop, which can predispose to electrolyte disturbances, arrhythmia, hemodynamic alterations, and shivering-induced increase of oxygen consumption. In an attempt to find an adequate end point temperature of rewarming after hypothermic CPB, 50 pediatric cardiac surgical patients were r ndomly assigned for end point temperature of rewarming of 35.5$^{\circ}C$ (Group 1) or 37t (Group 2), rectal temperature. Thereafter the rectal temperature was measured half, one, four, eight, and 16 hour after arrival to the intensive care unit(ICU), with heart rate and blood pressure. Additionally the rectal temperature was compared with esophageal temperature during CPB, and axillary temperature luring stay in the ICU. Nonpulsatile perfusion with a roller pump was used in all patients and a membrane or bubble oxygenator was used for oxygenation. Both groups were comparable with respect to age, sex, body surface area, total bypass time, and rewarming time. There was no afterdrop in both groups, and there were no statistical differences in the rectal temperatures between two groups. There were also no statistical dilyerences with respect to the heart rate and blood pressure between two groups. At the end of rewarming the esophageal temperature was higher than the rectal temperature. The axil ary temperature measured in ICU was always lower than the rectal temperature. No shivering was noted in all patients. In conclusion, with restoration of rectal temperature above 35.5$^{\circ}C$ at the end of CPB in pediatric patients, we did not observe an afterdrop.

  • PDF