• 제목/요약/키워드: 펌프동력

검색결과 158건 처리시간 0.022초

정수압방식 동력회수장치의 구동동력 절감량 해석 (An analysis on power regeneration of hydrostatic pressure exchanger)

  • 함영복;최준혁;정헌술;박상진;박중호;윤소남
    • 유공압시스템학회논문집
    • /
    • 제4권3호
    • /
    • pp.7-12
    • /
    • 2007
  • This paper presents an energy saving hydrostatic pressure exchanger for sea water desalination equipment. In a reverse osmosis(RO) system for desalinating sea water, more than 70 percent of the supplied sea water, brines which were impassable through RO membrane are bypassed, resulting in high energy losses. In this paper, a hydrostatic pressure exchanger consisting of an embedded water hydraulic piston motor and a water hydraulic piston pump was proposed and investigated in order to recover the energy of the bypassed brines. The pressurized brines are supplied to the embedded water hydraulic piston motor as power sources and the water hydraulic piston pump is driven by the output torque of the embedded water hydraulic piston motor as well as electric motor. Consequently, the energy of the bypassed brines can be recovered. To examine the electric energy saving characteristics of the hydrostatic pressure exchanger, a simulation model was constructed using commercial software and experiments were conducted. Through the results of simulation and experiment, the feasibility of the electric energy saving effect of the proposed hydrostatic pressure exchanger was investigated.

  • PDF

오신호 입력에 따른 펌프의 고장징후 조기감지 성능분석 (Performance Analysis on Early Detection of Fault Symptom of a Pump with Abnormal Signals)

  • 정재영;이병오;김형균;김대웅
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.66-72
    • /
    • 2016
  • As a method to improve the equipment reliability, early warning researches that can be detected fault symptom of an equipment at an early stage are being performed out among developed countries. In this paper, when abnormal signal is input to actual normal signal of a pump, early detection studies on pump's fault symptom were carried out with auto-associative kernel regression as an advanced pattern recognition algorithm. From analysis, correlations among power of motor driving pump, discharge flow of pump, power output of pump, and discharge pressure of pump are exited. When the abnormal signal is input to one of those normal signals, the other expected values are changed due to the influence of the abnormal signal. Therefore, the fault symptom of pump through the early-warning index is able to detect at an early stage.

배기가스 배열을 활용한 R245fa 냉매용 고온 히트펌프 건조기의 해석 및 검증 (Analysis and Verification of High Temperature Heat Pump Dryer using Waste Heat Recovery Type for R245fa Refrigerant)

  • 배경진;차동안;권오경
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.73-78
    • /
    • 2016
  • In this study, the performance characteristics of a high temperature heat pump dryer that is able to raise the air temperature up to $80^{\circ}C$ by using waste heat as heat source were investigated numerically. The main components of the heat pump dryer were modeling as a compressor, condenser, evaporator and expansion device, and R245fa was selected as refrigerant. Experiments were also conducted to validate the numerical data. As a result, when the evaporator air inlet temperature increased from $50^{\circ}C$ to $65^{\circ}C$, the numerical results of the hot air temperature at outlet and heat pump COP were about 8~11% and 5~8% higher than that of experimental ones, respectively.

수평관내 이산화탄소의 증발 압력강하 (Evaporation Pressure Drop of Carbon Dioxide in a Horizontal Tube)

  • 구학근;손창효
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.63-69
    • /
    • 2007
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

  • PDF

내부 유로 변경에 따른 전동기 일체형 유압펌프 내부의 유동특성에 관한 연구 (A Study on the Flow Characteristic for Changing of Flow Region of the Motor Inserted Oil Pump)

  • 최윤환;이태기;이연원
    • 동력기계공학회지
    • /
    • 제16권5호
    • /
    • pp.26-31
    • /
    • 2012
  • A numerical study has been carried out to investigate the heat and mass transfer of an oil pumping system with a variable shape of the housing using the CFD method. Especially, the electric motor and the pump combined together, accomplishes a research about the oil supplying system. In this study, the temperature and velocity distribution of the oil pumping system by varying the flow rate of supplying oil have been investigated. The temperature changes with each five conditions(flow rate of supply oil : 2, 4, 8, 12, and 16 liter/min) have also been studied. The numerical results show that the exhaust temperature decreases as the flow rate of the supplying oil increases. It also reveals that the temperatures change differently with the housing shape.

Low GWP 냉매를 적용한 해수열 히트펌프의 성능해석 (The Performance Analysis of Sea Water Heat Pump applied Low GWP Refrigerants)

  • 임승택;김현주;이호생
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.92-97
    • /
    • 2016
  • In this study, the seawater Heat Pump System using seawater with temperature of annual domestic conditions ($0^{\circ}C$ to $25^{\circ}C$) is designed in order to compare its performance against the Heat Pump using unused heat of seawater. As a potential replacement for current refrigerants that exacerbate global warming and ozone delpetion, a Low GWP refrigerant's performance is analyzed. The basic water to water Heat Pump system is chosen and three commercial refrigerants - R134a, R410a, R32 - are used to compare against new Low GWP refrigerant R1234ze. When seawater with temperature of $25^{\circ}C$ is used, the performance change showed maximal increase in COP, 38.3%. low GWP refrigerant R1234ze, showed great performance characteristics reach to 5.242 and Existing commercial refrigerant, R134a showed only less than 0.03 performance difference against R1234ze. The study confirms notable performance of R1234ze refrigerant through simulation as environmentally friendly refrigerant for domestic seawater Heat Pump.

응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리 (The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank)

  • 김동하;이수영;정의택
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

저소음 기어펌프용 연속접촉 헬리컬기어의 형상 설계에 관한 연구 (Theoretical Shape Analysis of Continuous Contact Helical Gear for Low Noise Pump)

  • 김갑태;신수식;지상원
    • 동력기계공학회지
    • /
    • 제22권6호
    • /
    • pp.58-66
    • /
    • 2018
  • The use of external gear pumps is an effective way to achieve adequate performance at low cost when composing hydraulic systems. The biggest drawback, on the other hand, is the accompanying noise. Gears of continuous contact shape are actively used for the pump recently. The continuous contact shape must be the helical type due to the nature of the gear pump that is driven only by the drive gear. In this paper the theoretical shape of continuous contact gear is analyzed using simple rack shape of straight lines and two circular arcs. Using such geometry, the theoretical equation will be developed by envelope curves according to the conjugate gear shape rules. After checking the validity of the theory by the shape of gear rules, the grinding shape was also developed. The 3D shapes using equation can be also drawn. It was also shown that contact ratio and radius of curvature are easily developed by the theoretical equations.

전기 유압식 동력 조향시스템용 외접형 기어펌프의 유량특성 근사식에 관한 연구 (A Study on the Approximate model of the Flow rate Characteristics in External Gear pump for EHPS)

  • 김지혜;김성관
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.548-553
    • /
    • 2013
  • Electro-Hydraulic Power Steering(EHPS) 시스템은 오일펌프에 직결된 전기모터를 통해 조향 조작력을 발생시키는 시스템이다. 이러한 스티어링 시스템 부품의 원가 및 성능을 최적화시키는 것은 매우 중요하다. 현재까지 EHPS 시스템과 같은 유압시스템의 개발은 실차 실험을 통해 문제점을 보완하여 개발하고 있기 때문에 많은 시간과 비용이 발생한다. 본 논문에서는 EHPS용 개발한 외접형 기어펌프의 토출유량측정실험을 수행하고 실험 데이터를 통하여 토출유량을 계산할 수 있는 유량 근사식을 제안하였다. 제안한 유량 근사식의 검증을 위해 실험데이터 및 AMESim 유량값과 비교하였고, 그 결과 각각의 유량특성간 오차율 5%내외로 유사성을 입증하였다.

임펠러 곡율반경(曲率半徑)이 농용양수기(農用揚水機)의 성능(性能)에 미치는 영향(影響)에 관(關)한 연구(硏究) (Effect of the Impeller-Blade Radius of Curvature on the Performance of Centrifugal Pump)

  • 최규홍;권순홍
    • Journal of Biosystems Engineering
    • /
    • 제13권2호
    • /
    • pp.18-27
    • /
    • 1988
  • 농용양수기(農用揚水機)의 효율적(效率的)인 양수작업(揚水作業)을 실시(實施)하기 위하여 최적(最適)의 임펠러설계(設計)에 필요(必要)한 수학적(數學的) 이론분석(理論分析)을 실시(實施)하여 기본모형(基本模型)을 만들고 이 기본모형(基本模型)을 기초(基礎)로 임펠러 날개곡율반경(曲率半徑)을 날개곡선(曲線)을 그리는 방법(方法)(원호곡선(圓弧曲線)과 인볼류트곡선(曲線))에 의해 변화(變化)시켜 설계제작(設計製作)하여 회전수별(回傳數別) 펌프성능(性能)을 조사(調査)하여 분석(分析)한 결과(結果)를 요약(要約)하면 다음과 같다. 1. 임펠러 날개곡율반경(曲率半徑)이 증가(增加)하여도 양수량(揚水量) 및 펌프효율(效率)에는 거의 영향(影響)을 미치지 않는 것으로 나타났다. 2. 임펠러 날개곡율반경(曲率半徑)이 증가(增加)함에 따라 실양정(實楊程) 및 소요동력(所要動力)은 증가(增加)하는 것으로 나타났다. 3. 임펠러 날개곡율반경(曲率半徑)을 구(求)할 때 인볼류트 곡선방법(曲線方法)이 원호곡선방법(圓弧曲線方法)보다 효과적(效果的)인 것으로 나타났다. 4. 이론분석(理論分析)에 의해 설계제작(設計製作)한 본(本) 임펠러가 기존(旣存)의 임펠러보다 펌프효율(效率)이 10%이상(以上) 증가(增加)한 것으로 나타났다.

  • PDF