• Title/Summary/Keyword: 펄스폭 변조 신호

Search Result 46, Processing Time 0.024 seconds

A Neural Network Design using Pulsewidth-Modulation (PWM) Technique (펄스폭변조 기법을 이용한 신경망회로 설계)

  • 전응련;전흥우;송성해;정금섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.1
    • /
    • pp.14-24
    • /
    • 2002
  • In this paper, a design of the pulsewidth-modulation(PWM) neural network with both retrieving and learning function is proposed. In the designed PWM neural system, the input and output signals of the neural network are represented by PWM signals. In neural network, the multiplication is one of the most commonly used operations. The multiplication and summation functions are realized by using the PWM technique and simple mixed-mode circuits. Thus, the designed neural network only occupies the small chip area. By applying some circuit design techniques to reduce the nonideal effects, the designed circuits have good linearity and large dynamic range. Moreover, the delta learning rule can easily be realized. To demonstrate the learning capability of the realized PWM neural network, the delta learning nile is realized. The circuit with one neuron, three synapses, and the associated learning circuits has been designed. The HSPICE simulation results on the two learning examples on AND function and OR function have successfully verified the function correctness and performance of the designed neural network.

Pressure Control Characteristics of a 2-Way Solenoid Valve Driven by PWM Signal (2방향 전자밸브의 PWM 신호에 의한 압력제어 특성)

  • Jeong, Heon-Sul;Kim, Hyoung-Eui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1565-1576
    • /
    • 2002
  • By way of driving a 2-way on/off solenoid hydraulic valve with a pulse width modulation (PWM) signal, control of the pressure in a certain volume is frequently used in various applications. However, the pressure built-up according to the duty ratio and carrier frequency of the PWM signal is not so well understood. In order to clarify the characteristics of 2-way valve hydraulic pressure control systems, in this paper two formula fur the mean and ripple of the load pressure were derived through theoretical analysis. And the accuracy of the derived formula were verified by comparison with the experimental test result. Generally 2-way valve systems are constructed as a bleed-off circuit, while 3-way valves are used as a control element in a meter-in circuit pressure control system. In a bleed-off circuit, the system supply pressure from a hydraulic power pack does not remain constant, but changes according to their external load. In turn, the relief valve in the hydraulic power pack reacts accordingly showing complicated dynamic behavior, which makes an analytical study difficult. In order to resolve the problem, simple but accurate empirical dynamic models fer a bleed-off system were used in the course of formula derivation. As the result, selection criteria for two major control parameters of the driving signal is established and the basic strategy to suppress the unnecessary pressure fluctuation can be provided for a hydraulic pressure control system using a 2-way on/off solenoid valve.

Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation (LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성)

  • Hwang, Lark-Hoon;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.420-428
    • /
    • 2018
  • In this paper, represented uninterruptible power supply (UPS) equipment maintaining constant output voltage, the proposes a photovoltaic system constructed with a step up boosting chopper and single phase pulse width modulation (PWM) voltage source inverter. as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic that it was so called constant voltage charge. It can be results of saving electric power, and through a normal operation of energy storage system (ESS), the system operated the LED a calling on signal changes at the airport in an efficient manner. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

A dual-loop boost-converter LED driver IC with temperature compensation (온도 보상 및 듀얼 루프를 이용한 부스트 컨버터 LED 드라이버 IC)

  • Park, Ji-Hoon;Yoon, Seong-Jin;Hwang, In-Chul
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.6
    • /
    • pp.29-36
    • /
    • 2015
  • This paper presents an LED backlight driver IC consisting of three linear current regulators and an output-voltage regulation loop with a self-adjustable reference voltage. In the proposed LED driver, the output voltage is controlled by dual feedback loops. The first loop senses and controls the output voltage, and the second loop senses the voltage drop of the linear current regulator and adjusts the reference voltage. With these feedback loops, the voltage drop of the linear current regulator is maintained at a minimum value, at which the driver efficiency is maximized. The output of the driver is a three-channel LED setup with four LEDs in each channel. The luminance is adjusted by the PWM dimming signal. The proposed driver is designed by a $0.35-{\mu}m$ 60-V high-voltage process, resulting in an experimental maximum efficiency of approximately 85%.

Intelligent silicon bead chip design for bio-application (바이오 응용을 위한 지능형 실리콘 비드 칩 설계)

  • Moon, Hyung-Geun;Chung, In-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.999-1008
    • /
    • 2012
  • Unlike the existing CMOS chip, ISB (Intelligent Silicon Bead) is new concept biochip equipped with optical communication and memory function. It uses the light for power of SoC CMOS and interface with external devices therefore it is possible to miniaturize a chip size and lower the cost. This paper introduces an input protocol and a design of the low power and the low area to transfer the power and the signal through a single optical signal applied from external reader device to bead chip at the same time. It is also verified through simulation and measurement. In addition, low-power PROM is designed for recording and storing ID of a chip and it is successful in obtaining the value of output according to the optical input. Through this study, a new type biochip development can be expected by solving high cost and a limit of miniaturizing a chip area problem of an existing RFID.

A Study on the Security of Infrastructure using fiber Optic Scattering Sensors (광섬유 산란형 센서를 이용한 사회기반시설물의 보안에 관한 연구)

  • Kwon, Il-Bum;Yoon, Dong-Jin;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.499-507
    • /
    • 2004
  • We have studied tile detection techniques, which can determine the location and the weight of an intruder into infrastructure, by using fiber-optic ROTDR (Rayleigh optical time domain reflectometry) sensor and fiber-optic BOTDA (Brillouin Optical time domain analysis) sensor, which can use an optical fiber longer than that of ROTDR sensor Fiber-optic sensing plates of ROTDR sensor, which arc buried in sand, were prepared to respond the intruder effects. The signal of ROTDR was analyzed to confirm the detection performance. The constructed ROTDR could be used up to 10km at the pulse width of 30ns. The location error was less than 2 m and the weight could be detected as 4 grades, such as 20kgf, 40kgf, 60kgf and 80kgf. Also, fiber optic BOTDA sensor was developed to be able to detect intrusion effect through an optical fiber of tells of kilometers longer than ROTDR sensor. fiber-optic BOTDA sensor was constructed with 1 laser diode and 2 electro-optic modulators. The intrusion detection experiment was peformed by the strain inducing set-up installed on an optical table to simulate all intrusion effect. In the result of this experiment, the intrusion effort was well detected as the distance resolution of 3m through the fiber length of about 4.81km during 1.5 seconds.