• Title/Summary/Keyword: 펄스조정

Search Result 89, Processing Time 0.023 seconds

Development of Voltage Regulator and Pulse Charger Using Pulse Current for Reuse of the Waste Lead Acid Battery (폐납축전지 재활용을 위한 펄스전류에 의한 전압조정기와 펄스충전기의 개발)

  • Shin, Choon-Shik;An, Young-Joo;Kim, Dong-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.65-73
    • /
    • 2007
  • In this study, the pulse charger and voltage regulator are proposed that can reuse the waste lead acid battery. The first we develop the voltage regulator that can reuse the waste lead battery. And the pulse current is applied to the terminal of the waste lead acid battery. The voltage regulator is available principle of the pulse current which can reduce the sulfate to incipient material such as Pb and PbO2. Therefore the internal resistance of the lead acid battery is decreased, the performance of the lead acid battery is improved and the durability is prolonged. The second we develop the pulse charger using the voltage regulator. The pulse charger uses the switch mode of the forward convert method. The pulse charger maintain the constant voltage in state removing the lead acid battery and when it connected the pulse charger, it is converted the charge mode of the constant current immediately. It continues the rapid charge until the full state of the lead acid battery. After that the pulse charger is converted to the charge mode of constant voltage automatically, and then it continues the normal charge. The experiment results show that the effectiveness of the voltage regulator and pulse charger such as the good performance and the prolonged durability in lead acid battery of the small and large capacity.

The Analysis of the Effect of Narrowband Interference on UWB communication system (UWB(Ultra-Wide Bandwidth) 통신 시스템에서 협대역 간섭 잡음 해석)

  • 박장우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1153-1160
    • /
    • 2003
  • In this paper, the performance of the UWB communication systems is analyzed in the presence of the Narrow Band Interference(NBI). UWB communication systems are modeled as using the Pulse Position Modulation(PPM). In this system, a Gaussian monocycle is used as the received pulses. The NBI is considered as a zero-mean random process with a constant spectral power density over its whole bandwidth. We obtain the mathematical expressions for describing the effect of the NBI on the UWB system. And it can be shown that the suppression of the effect of NBI on the UWB systems is available by adjusting the PPM related parameter.

A Study on the control of output power and pulse repetition rate in pulsed Nd:YAG laser (펄스형 Nd:YAG 레이저의 출력 에너지 및 펄스 반복률 제어에 관한 연구)

  • Park, K.R.;Kim, B.G.;Moon, D.S.;Hong, J.H.;Kim, W.Y.;Kang, U.;Kim, H.J.;Cho, J.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.74-77
    • /
    • 2000
  • A pulsed Nd:YAG laser has been used in a wide variety of fields : measuring, material processing and so on. In a material processing, it is very important to control the laser energy density. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, pulsed Nd:YAG laser system was designed and manufactured to control the laser output usefully and easily. This system adopted the sequential charge and discharge circuit is controlled by 80196 micro- processor. As a result, it is found that laser output is controlled minutely by changing laser input and pulse repetition rate, and usefully by using 80196 microprocessor.

  • PDF

Determination of Optimal Turn-off Angle for SRM Converter Using Self-Tuning Method (SRM 컨버터에서 자기동조 방식에 의한 턴오프 각의 결정)

  • 장도현;문진영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.418-425
    • /
    • 1998
  • In this paper. determination method of turn-off angle in the SRM drives is proposed to maintain the high torque at a any turn-on angle, which is realized by using selHuning control method, During the sampling time. a number of P pulses from encoder are checked by using one-chip microprocessor. and compared with pre-checked a number of pulses A After calculating difference between two data, the turn-off angle moves forward or backward direction by the self-tuning m method, As repeating such process, the optimal turn-off angle is determined and the maximum torque is maintained T Though experiments, it is observed that motor speed is almost maintained if turn-off angle is adjusted automatically by s selHuning method when turn-ηn angle is changed.

  • PDF

An ACLMS-MPC Coding Method Integrated with ACFBD-MPC and LMS-MPC at 8kbps bit rate. (8kbps 비트율을 갖는 ACFBD-MPC와 LMS-MPC를 통합한 ACLMS-MPC 부호화 방식)

  • Lee, See-woo
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • This paper present an 8kbps ACLMS-MPC(Amplitude Compensation and Least Mean Square - Multi Pulse Coding) coding method integrated with ACFBD-MPC(Amplitude Compensation Frequency Band Division - Multi Pulse Coding) and LMS-MPC(Least Mean Square - Multi Pulse Coding) used V/UV/S(Voiced / Unvoiced / Silence) switching, compensation in a multi-pulses each pitch interval and Unvoiced approximate-synthesis by using specific frequency in order to reduce distortion of synthesis waveform. In integrating several methods, it is important to adjust the bit rate of voiced and unvoiced sound source to 8kbps while reducing the distortion of the speech waveform. In adjusting the bit rate of voiced and unvoiced sound source to 8 kbps, the speech waveform can be synthesized efficiently by restoring the individual pitch intervals using multi pulse in the representative interval. I was implemented that the ACLMS-MPC method and evaluate the SNR of APC-LMS in coding condition in 8kbps. As a result, SNR of ACLMS-MPC was 15.0dB for female voice and 14.3dB for male voice respectively. Therefore, I found that ACLMS-MPC was improved by 0.3dB~1.8dB for male voice and 0.3dB~1.6dB for female voice compared to existing MPC, ACFBD-MPC and LMS-MPC. These methods are expected to be applied to a method of speech coding using sound source in a low bit rate such as a cellular phone or internet phone. In the future, I will study the evaluation of the sound quality of 6.9kbps speech coding method that simultaneously compensation the amplitude and position of multi-pulse source.

Analysis of the Monopulse Radar Tracking Errors using Orthogonally Deployed Antenna Sets for Cross-eye Jamming (십자형으로 배치된 크로스아이 재머 안테나를 이용한 모노펄스 레이다 재밍 오차 분석)

  • Lim, Joong-Soo;Chae, Gyoo-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.6
    • /
    • pp.14-18
    • /
    • 2020
  • In this paper, when two sets of cross-eye jammer antennas are installed vertically to jam a monopulse radar, the jamming effects according to the jammer's phase difference, amplitude ratio, and radar angle of engagement are analyzed. The phase difference and amplitude ratio of the cross-eye jammer can be adjusted in the jammer, but since the angle of engagement is relatively determined by the radar, it is very important to respond to changes in the angle of engagement. The orthogonally deployed jammer antennas can be considered as a good way to increase the jamming effect while minimizing the hardware configuration, and the jamming effect is analyzed while changing the angle of inclination from 0° to 360°. This jammer greatly improves the jamming effects at the angles of incidence 45°~135° and 225°~315°, compared to a single jammer. And it is expected to be useful in the design of cross-eye jammers for military aircraft and ships.

Development of High Stable Instrumentation and Analytic Techniques for Radioactive Pulses (방사선 펄스의 고안정 계측 및 분석기술 개발)

  • 길경석;송재용;한주섭;김일권;손원진
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.2
    • /
    • pp.303-308
    • /
    • 2001
  • An objection of this study is to develop a high stable measuring circuits and a analytic system for radioactive pulses. The proposed system consists of a pulse detection units for neutrons and gamma-rays a programmable high voltage supply unit and a digital signal processor. The programmable high voltage supply unit designed can generate DC voltage up to 1,500 V at 5 V input and have a series voltage regulator to maintain the output voltage constantly, resulting in less than 1.63% of voltage regulation. The pulse detection parts consists of an active integrator, a pole-zero circuit, and a 3-stage amplifier of 60 dB, and its frequency bandwidth is from 37 Hz to 300 kHzAlso, pulse height distribution in accordance with pulse counts is important data in analyzing radioactive pulses. In this study, A/D convertor (12bit, 100ms) and DSP (TMS320C31-60) are used to analyze the pulse height, and the analytic system is designed to be operated in PC-base.

  • PDF

Three-Dimensional Processing of Ultrasonic Pulse-Echo Signal (초음파 펄스에코 신호의 3차원 처리)

  • Song, Moon-Ho;Song, Sang-Rock;Cho, Jung-Ho;Sung, Je-Joong;Ahn, Hyung-Keun;Jang, Soon-Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.5
    • /
    • pp.464-474
    • /
    • 2003
  • Ultrasonic imaging of 3-D structures for nondestructive evaluation must provide readily recognizable images with enough details to clearly show various flaws that may or may not be present. Typical flaws that need to be detected are miniature cracks, for instance, in metal pipes having aged over years of operation in nuclear power plants; and these sub-millimeter cracks or flaws must be depicted in the final 3-D image for a meaningful evaluation. As a step towards improving conspicuity and thus detection of flaws, we propose a pulse-echo ultrasonic imaging technique to generate various 3-D views of the 3-D object under evaluation through strategic scanning and processing of the pulse-echo data. We employ a 2-D Wiener filter that filters the pulse-echo data along the plane orthogonal to the beam propagation so that ultrasonic beams can be sharpened. This three-dimensional processing and display coupled with 3-D manipulation capabilities by which users are able to pan and rotate the 3-D structure improve conspicuity of flaws. Providing such manipulation operations allow a clear depiction of the size and the location of various flaws in 3-D.

Design of the Acupoint Discriminator(DM96A-2) by Improvement of Meridian Point Discrimination Parameter (경혈식별 파라메터의 개선에 의한 혈위식별시스템 DM96A-2의 설계)

  • 이후학;어윤기고수복정동명
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.825-828
    • /
    • 1998
  • 경혈을 대상으로 인체를 진단하는 의료기기들은 경혈점에 미세한 직류전류를 인가하고, 이 점에서의 전기저항과 세포의 분극에 의해 반응하는 경락체계의 균형상태를 측정하여 인체를 종합적으로 진단한다. 따라서 전 과정이 정확한 경혈의 위치에서 이루어져야만 치료효과와 진단의 신뢰성이 보장된다. 그러나 대부분의 경락관련 치료기들이 정확한 혈위식별에 어려움이 있고 사용자의 전문적 숙련을 요구한다. 따라서 선행연구에서 일정한 주파수로 교호되는 자극패턴(SPAC) 방식을 사용하여 식별률을 높인 혈위식별기 DM96A-1를 개발하였다. DM96A-1은 단일전원이 양방향으로 교호되는 전류로 자극펄스를 출력하고 측정범위가 0.5∼50㎂인 전류메터와 레벨메터를 이용하여 혈위의 전류량을 표시한다. 이에 따라 방향전환 소자의 두 채널 제어신호가 교호되는 과도기에서 두 자극패턴의 중첩 도통에 의해서 누설전류가 발생하는 경우가 있으며 이를 제거하기 위하여 정밀한 조정을 필요로 하는 불편이 있었다. 따라서 이와 같은 단점들을 보완하여 신뢰성 있는 출력 파라메터를 얻을 수 있도록 마이크로프로세서 i80c196kc를 사용하여 DM96A-2를 재 설계하였으며 임상실험에 의하여 개선된 최적 파라메터의 타당성을 검증하였다.

  • PDF

A Study on the Position Detection Device for a Hybrid Type Linear Pulse Motor (HB형 LPM의 위치검출장치에 관한 기초연구)

  • 신춘식;김남호;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 1996
  • In recent years, as the electonic industry has become more advanced, the LPM(Linear Pulse Motor) has appeared in a wide range of applications because of easier control, operation by open-loop control, high positioning accuracy, and retrieval of position or velocity data by the input pulses. In this study, we deal with the development of a position detection device attached to a hybrid LPM in our laboratory. Precise position detection signals could be sensed by the synchronous rectifier method from the LPM stator scale. In addition, we can keep the amplitude constant by using an AGC(Automatic Gain Control) circuit. Experimental results show that the position data is good enough to perform the LPM position control.

  • PDF