• Title/Summary/Keyword: 펄스열파형

Search Result 18, Processing Time 0.024 seconds

A Study on Waveform Analysis of Input Current for Novel Boost AC-DC Converter of High Power Factor (새로운 고역률 승압형 AC-DC 컨버터의 입력전류 파형분석에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.102-108
    • /
    • 2005
  • In this paper, authors propose novel boost AC-DC converter of high power factor and analyze for waveform and harmonics component of input current. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of at input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of conventional converter of high power factor. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

An Electromagnetic Induction Underwater Acoustic Transducer Design And Its Characteristics (電磁誘導形 水中音原의 제작과 특성 해석)

  • Park, Yoon-Kyu;Ha, Kang-Iyeol;Chang, Jee-Won
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.3
    • /
    • pp.67-73
    • /
    • 1992
  • An electromagnetic induction transducer which radiates an implusive ultrasonic wave, could be useful for high power sound source in underwater acoustical survey. The aim of this study is to investigate the waveforms and the spectral characteristics of the waves produced by the transducer which was on the basis of the design criteria proposed by Eisenmenger. It was found that the sound pressure levels of the impulsive ultrasonic waves were directly proportional to the capacitance of the energy stored in the capacitor and inversely proportional to the thickness of the vibrating copper foil, while the center frequencies and the fractional bandwidths were vice versa.

  • PDF

Effect of Structural Parameters on Acoustic Field of A Curved Linear Array Transducer (굴곡형 선형 배열 탐촉자의 음장에 미치는 구조 파라메터의 영향)

  • Song Heang-Yong;Ha Kang-Lyeol;Kim Moo-Joon;Kim Dong-Hyeon;Lee Soo-Sung
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.385-388
    • /
    • 2002
  • 현재 복부용 초음파 진단장치에 가장 일반적으로 사용 되고 있는 3.5MHz의 굴곡형 선형배열(curved linear array) 탐촉자에 대하여, 탐촉자 요소의 폭과 높이, 측 방향 및 높이 방향의 곡률 반경 둥의 구조적인 파라메터 변화가 음장에 미치는 영향을 시물레이션을 통하여 체계적으로 해석하였다. 시물레이션에 있어서, 탐촉자는 128개의 요소변환자 중 32개에 의해 초음파 빔을 형성하며, 매질 중에 방사된 파형은 코사인 포락선을 갖는 3주기의 펄스인 것으로 일정하게 가정하였다. 시뮬레이션의 결과, 탐촉자의 측 방향 및 높이 방향 곡률보다는 탐촉자 요소의 폭 및 개구높이가 음장에 더 많은 영향을 미치고 있음을 알 수 있었다.

  • PDF

Design and embodiment of stable system by change of action waveform by pulsemodule special quality of pulse style$CO_2$ laser for obstetrics and gynecology (산부인과용 펄스형 $CO_2$레이저의 펄스모듈 특성과 동작파형 변화에 따른 안정된 시스템의 설계 및 구현)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • [ $CO_2$ ] laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400um laser beam in rain focus sacred ground surroundings cellular tissue without vitiation me by evaporation Poe of very small floor as is clean steam can . Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of Pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can . Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

Design of digital clock level translator with 50% duty ratio from small sinusoidal input (작은 정현파입력의 50% Duty Ratio 디지털 클럭레벨 변환기 설계)

  • Park, Mun-Yang;Lee, Jong-Ryul;Kim, Ook;Song, Won-Chul;Kim, Kyung-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.8
    • /
    • pp.2064-2071
    • /
    • 1998
  • A new digital clock level translator has been designed in order to produce a clock source of the internal logic circuits. The translator output has 50% duty ratio from small sinusoidal input such as TCXO which oscillates itself in poratable components. The circuit consists of positive and negative comparators, RS latch, charge pump, and reference vol- tage generator. It detects pulse width of the output waveform and feedbacks the control signal to the input com-parator. It detects pulse width of the output waveform and feedbacks the control signal to the input com-parator reference, producing output waveform with valid 50% duty ratio of the digital signal level. The designed level translator can be used as a sampling clock source of ADC, PLL and the colck source of the clock synthesizer. The circuit wasdesigned in a 0.8.mu.m analog CMOS technology with double metal, double poly, and BSIM3 circuit simulation model. From our experimental results, a stable operating characteristics of 50 +3% duty ratio was obtained from the sinusoidal input wave of 370 mV.

  • PDF

Doppler Profile Extraction to Air-Breathing Targets with PT-Waveform Received Signal and Target Tracking Information on a Ground Radar (지상레이다의 PT-파형 수신신호와 항공기 추적정보를 이용한 항공기 도플러 프로파일 추출)

  • Oh, Hyun-Seok;Kim, Soo-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.2
    • /
    • pp.129-138
    • /
    • 2017
  • This paper has been shown for the extraction of Doppler signature from the radar signal for an air-breathing targets tracked in the ground radar. For the extractions, a Doppler resolution is confirmed from mathematical modeling of PT(pulse train) waveform. Doppler signatures of air-breathing target are varied to radar aspect angle of engine and are determined from physical parameter of jet engine. To confirm such Doppler signatures, the radar signal reflected from the air-breathing target is obtained by our radar signal storage. After this extraction, radar aspect angle of engine has estimated from tracking information. Relative differences of Doppler signatures to radar aspect angle of engine is verified from these results and Doppler profiles for radar target identification appliance are presented.

Design of PWM-Based Photo Irradiation System for Acne Treatment (여드름 치료를 위한 PWM 기반 광 조사 시스템 설계)

  • Kim, Chang-Su;Lim, Hyun-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.207-215
    • /
    • 2012
  • As one of photo dynamic therapies, the existing LED photo irradiation method with 635 nm continuous wave has most frequently been used for acne treatment, it suffered from a low energy efficiency and generation of a large amount of heat in tissues requiring improvement measures. In this thesis, a LED photo irradiation system for acne treatment has been designed using PWM(Pulse Width Modulation) mode to enhance the energy efficiency and prevent thermal destruction in tissues. System configuration consisting largely of timer module, PWM module, and photo transfer device has been designed with the use of 1 W LED at a wavelength of 660 nm for the photo transfer device to increase skin penetration depth for treatment of acne. Frequency and wave form generated by using PWM control was verified along with confirmation of output energy of 660 nm LED and surface temperatures of tissues, followed by evaluation of stable energy outputs and stability of tissues. The results indicated that whereas power loss was high and thermal destruction in tissues was exhibited when C.W mode was used to obtain the optical energy of 1 W LED at a wavelength of 660 nm for acne treatment, realization of PWM mode allowed lowering of power consumption for LED through pulse width modulation, and no occurrence of thermal destruction in tissues, suggesting that PWM mode is safer and more effective for treatment of acne than C.W mode.

The dynamic stiffness of resilient materials for floor impact sound according to temperature change (온도변화에 따른 바닥충격음 완충재의 동탄성계수 변화)

  • Yeon, Junoh;Goo, Heemo;Lee, Sungchan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.338-342
    • /
    • 2018
  • In order to solve the floor impact sound problem in the upper and lower floors, the Ministry of Land, Transport and Maritime Affairs also notifies the physical properties of the resilient material affecting the floor impact sound level. The dynamic modulus of elasticity and the loss factor before and after heating are most related to the floor impact noise, especially for the cushioning material. Therefore, in this study, the rate of change with respect to the dynamic modulus and loss factor with temperature change was examined by increasing $10^{\circ}C$ by $10^{\circ}C$ from the temperature condition of $70^{\circ}C$ specified in the standard. The dynamic modulus of elasticity and the loss modulus were measured by using the pulse excitation method for eight kinds of samples. The calculation method was calculated by the time series analysis method using the damped vibration waveform.