An Electromagnetic Induction Underwater Acoustic Transducer Design And Its Characteristics

電磁誘導形 水中音原의 제작과 특성 해석

  • 박윤규 (부산수산대학교 물리학과) ;
  • 하강열 (부산수산대학교 물리학과) ;
  • 장지원 (부산수산대학교 물리학과)
  • Published : 1992.06.01

Abstract

An electromagnetic induction transducer which radiates an implusive ultrasonic wave, could be useful for high power sound source in underwater acoustical survey. The aim of this study is to investigate the waveforms and the spectral characteristics of the waves produced by the transducer which was on the basis of the design criteria proposed by Eisenmenger. It was found that the sound pressure levels of the impulsive ultrasonic waves were directly proportional to the capacitance of the energy stored in the capacitor and inversely proportional to the thickness of the vibrating copper foil, while the center frequencies and the fractional bandwidths were vice versa.

電磁誘導形 音源裝置는 짧은 펄스의 음파를 수중에 放射시킬 수 있어, 높은 距離分解能이 요구되는 해저 탐사용 음원 또는 수중 음파전달 특성시험용 음원등으로 널리 이용될 수 있다. 본 연구에서는 Eisenmenger가 제안한 형태의 電磁誘導形 音源裝置를 설계 제작하여, 放射되는 음파의 파형을 관찰하고, 그 주파수 특성을 분석하였다. 제작된 음원으로부터는 약 한 주기의 짧은 충격 펄스의 초음파가 얻어졌으며, 그 음압은 진동판의 두께가 얇은 경우에 크며, 콘덴서의 용량에 비례하여 증가하였다. 발생된 초음파의 중심 주파수는 振動板의 두께가 두꺼운 경우에 높으며, 콘덴서 용량이 증가할수록 낮아지고, 대역폭도 좁아졌다.