• Title/Summary/Keyword: 펄스시퀀스

Search Result 52, Processing Time 0.018 seconds

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

Scolytidae, Platypodidae, Bostrichidae and Lyctidae Intercepted from Imported Timbers at Busan Port Entry (부산항의 수입재에서 검출된 나무좀과, 긴나무좀과, 개나무좀과 및 가루나무좀과의 종류)

  • 최은정;추호렬;이동운;이상명;박종균
    • Korean journal of applied entomology
    • /
    • v.42 no.3
    • /
    • pp.173-184
    • /
    • 2003
  • Beetles belonging to the families Scolytidae, Platypodidae, Bostrichidae, and Lyctidae intercepted from imported timbers at Busan port were investigated from March 1 to November 30 in 2000. In addition, hosts imported country were examined. A total of 52 species of within 23 genera was intercepted from nineteen species of timbers or logs from fifteen countries. In Scolytidae, 35 species of 16 genera in three subfamilies were identified 12 species in Xyleborus, 6 species in Ips, 3 species in Trypodendron, 2 species in Arixyleborus, and 12 species of all different genera including Alinphagous. Scolytidae were intercepted from 16 species of timbers in 13 genera imported from 11 countries. The highest beetles were intercepted from Malaysian lauan. In Platypodidae, 9 species of one genus (Platypus) were intercepted from 6 species of timbers in 4 genera imported from 6 countries including Australia. The highest numbers were intercepted from Malysian lauan. In Bostrychidae, 5 species of 4 genera in two subfamilies were intercepted from 6 species of timbers in 4 genera imported from four countries. In Lyctidae, Trogoxylon sp., Minthea sp., and Minthea rugicollis were intercepted from 3 species of timbers in 2 genera imported from 3 countries.